Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Houston”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

822 records · Page 46

Panel Session 100: An Integrated Systems-Based Monitoring Approach

This panel focused on recent advancements in monitoring and remaining challenges associated with the implementing cost-effective monitoring approaches for complex DOE sites. Monitoring presents one of the largest, long-term costs for environmental remediation and site stewardship within the DOE because contamination at complex sites will likely be present for tens to hundreds of years into the future. Integration of monitoring with predictive modeling is an approach that can reduce long-term monitoring costs as well as support the effective monitoring design and data interpretation for managing a site toward closure and long-term stewardship. Panelists with presentations: Autonomous Electrical Geophysical Monitoring of Contaminated Sites (Tim Johnson); Systems Based Long-Term Monitoring for DOE Legacy Management (David Shafer); Long-Term Systems Based Monitoring (Anderson Ward)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 26: Risk-Based Approaches to Environmental Remediation and Adaptive Site Management

This panel discussed the needs and importance of developing risk-based approaches to environmental remediation that will enable complex sites to be adaptively managed by applying cost-effective remedies that are protective of human health and the environment. The discussion emphasized risk-based approaches within decision processes and subsequent incorporation into regulatory decision documents. Remedy approaches, remediation exit strategies, and long-term monitoring plans that support risk-based end-states for difficult-to-remediate sites were discussed Panelists with presentations: Risk-Informed Approaches to Environmental Remediation and Adaptive Site Management (Vicky Freedman); ITRC Adaptive Site Management Perspective (Michael Truex); Optimization During Operations and Maintenance Phase at the Hanford Site 200-ZP-1 Groundwater Operable Unit (Emerald Laija, Kate Amrhein, Michael Truex); Adaptive Management: EPA Overview (Benjamin Simes); Decommissioning and Environmental Remediation Section Division of Nuclear Fuel Cycle and Waste Technology (Horst Monken Fernandes)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗

The NuMI Flux Prediction at ICARUS

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment seeking to probe fundamental symmetries within the structure of the Pontecorvo-Maki-Nakagawa-Sakata (PMNS) mixing matrix, and perform precision measurements its parameters including the neutrino mass ordering via the sign of $\Delta m^2_{31}$, and the charge-parity violating phase, $\delta_{CP}$. To make these measurements with high precision, DUNE will require external $\nu$-Ar scattering cross section data as a crucial input to the oscillation fit. Imaging Cosmic And Rare Underground Signals (ICARUS) is a 476 t liquid argon neutrino detector located at Fermi National Accelerator Laboratory (FNAL) where it is serving as the far detector for the Short-Baseline Neutrino (SBN) program along the Booster Neutrino Beam (BNB) axis. ICARUS additionally lies 795 m downstream and 100.1 mrad off-axis of the Neutrinos at the Main Injector (NuMI) neutrino beam. From this position, ICARUS is exposed to a large flux of NuMI (anti-)electron and (anti-)muon neutrinos, and poses a unique opportunity to provide high-statistics measurements of quasi-elastic and single pion-production cross sections for four neutrino flavors ($\nu_{\mu}$, $\nu_{e}$, $\bar{\nu}_{\mu}$, $\bar{\nu}_{e}$). This dissertation is centered around accurately characterizing the models and estimating their precision for use in making these measurements. This includes identifying major sources of uncertainty in the models such that they can be properly propagated to the cross section measurements. Specifically, this work focused on the model of the NuMI beamline and its impact on the neutrino fluxes, but also delved into the detector response model and its impact on reconstructed observables in the detector. Significant efforts were made to improve the characterization to enhance precision and thus reduce the level of propagated uncertainty. In particular, the NuMI flux was determined to be composed of 57% $\nu_{\mu}$, 38% $\bar{\nu}_{\mu}$, 3% $\nu_{e}$, and 2% $\bar{\nu}_{e}$ while the horns are operating in the positive-particle focusing configuration. The total uncertainty on the $\nu_{\mu} + \bar{\nu}_{\mu}$ ($\nu_{e} + \bar{\nu}_{e}$) flux while operating in the forward horn operating mode was determined to be 10.84% (9.04%). Compared to the on-axis flux, mesons that eventually decay to neutrinos more frequently reinteract within the NuMI structure, resulting in elevated uncertainty as these processes are not well-constrained by existing hadron interaction cross section measurements. Covariance matrices were calculated to propagate the flux uncertainty characterization to NuMI analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurement of $π^+$-Ar and $p$-Ar Total Inelastic Cross Sections in the Sub-GeV Energy Regime with ProtoDUNE-SP Data

The ProtoDUNE-SP detector, a kiloton-scale prototype for the Deep Underground Neutrino Experiment (DUNE), is the largest liquid argon time projection chamber built to date. Operated at CERN from 2018 to 2020, it collected both cosmic-ray data and a beam consisting of positively-charged particles with discrete momentum settings across a range of 0.3 GeV/$c$ to 7 GeV/$c$. In this letter, we report the total inelastic cross section measurements for $π^+$-Ar and $p$-Ar interactions using selected $π^+$ and proton samples from the 1 GeV/$c$ beam data. These results provide the first measurement of the total inelastic cross sections for $π^+$-Ar in the 500-900 MeV kinetic energy range and for $p$-Ar below 450 MeV, both of which are directly relevant to the DUNE energy range. The measured cross sections are consistent with predictions and provide a dataset that was previously unavailable for argon targets. These measurements are essential for constraining neutrino-argon interaction models, which are crucial for the precision physics goals of the upcoming DUNE experiment.

Abbaslu, Saeed [IPM, Tehran] (ORCID:00000003356771↗

Measurement of the Triple-Differential Cross Section of Muon Neutrino Charged Current Interactions with Low Hadronic Activity in the NO$\nu$A Near Detector

This dissertation describes the analysis and measurement of the triple-differential cross-section of the $\nu_\mu CC$ interaction with Low Hadronic Activity (maximum kinetic energy of 250 MeV for protons and 175 MeV for pions) in the NOvA Near Detector. This cross-section is reported in bins of Muon Kinematics and available hadronic energy. The data corresponds to an accumulated $14.2\times10^{20}$ protons-on-target (POT) in the neutrino mode of the NuMI beam, with a narrow band of neutrino energies peaked at 1.8 GeV. The analysis provides a sample of neutrino–nucleus interactions with an enhanced fraction of quasi-elastic (QE) and two-particle-two-hole (2p2h) interactions and a suppression of resonant pion production (RES) and deep inelastic scattering (DIS) interactions. This enhancement of QE and 2p2h allows for quantitative comparisons with various models of these processes. We find strong disagreement between data and theory-based models in the forward muon direction, especially for the 0.2-0.4 GeV available hadronic energy region.

Lesmeister, James Ryan [Houston U.]↗

A Bayesian approach to the long-baseline neutrino oscillation sensitivity of DUNE

The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is evaluated using a Bayesian Markov Chain Monte Carlo (MCMC) approach. This analysis uses the same underlying sensitivity inputs as previous DUNE studies [Eur. Phys. J. C 80, 978 (2020)], and therefore does not present updated DUNE sensitivities, but instead explores the additional inferences accessible using a Bayesian approach. We present four-dimensional posterior probability distributions of the oscillation parameters, highlighting the breadth of correlation in the parameter space of interest, especially between $\sin^2 θ_{23}$ and $\sin^2 θ_{13}$. We exploit the flexibility of the Bayesian framework to incorporate parameter constraints post hoc and assess the impact of applying a reactor short-baseline $θ_{13}$ constraint. A significant increase in the sensitivity to the $θ_{23}$ octant is found when including the constraint. Posterior distributions of derived quantities can be easily constructed from MCMC results. This work presents the first study of DUNE's sensitivity to the Jarlskog invariant, $J$, a quantity that provides a parametrisation-independent measure of charge-parity violation in the leptonic sector.

Abbaslu, Saeed [IPM, Tehran] (ORCID:00000003356771↗