Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High precision control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Attosecond synchronization of extreme ultraviolet high harmonics from crystals

The interaction of strong near-infrared (NIR) laser pulses with wide-bandgap dielectrics produces high harmonics in the extreme ultraviolet (XUV) wavelength range. These observations have opened up the possibility of attosecond metrology in solids, which would benefit from a precise measurement of the emission times of individual harmonics with respect to the NIR laser field. In this work, we show that, when high-harmonics are detected from the input surface of a magnesium oxide crystal, a bichromatic probing of the XUV emission shows a clear synchronization largely consistent with a semiclassical model of electron–hole recollisions in bulk solids. On the other hand, the bichromatic spectrogram of harmonics originating from the exit surface of the 200 μm-thick crystal is strongly modified, indicating the influence of laser field distortions during propagation. Our tracking of sub-cycle electron and hole re-collisions at XUV energies is relevant to the development of solid-state sources of attosecond pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

EXPRES. II. Searching for Planets around Active Stars: A Case Study of HD 101501

By controlling instrumental errors to below 10 cm s{sup −1}, the EXtreme PREcision Spectrograph (EXPRES) allows for a more insightful study of photospheric velocities that can mask weak Keplerian signals. Gaussian processes (GP) have become a standard tool for modeling correlated noise in radial velocity data sets. While GPs are constrained and motivated by physical properties of the star, in some cases they are still flexible enough to absorb unresolved Keplerian signals. We apply GP regression to EXPRES radial velocity measurements of the 3.5 Gyr old chromospherically active Sun-like star, HD 101501. We obtain tight constraints on the stellar rotation period and the evolution of spot distributions using 28 seasons of ground-based photometry, as well as recent Transiting Exoplanet Survey Satellite data. Light-curve inversion was carried out on both photometry data sets to reveal the spot distribution and spot evolution timescales on the star. We find that the >5 m s{sup −1} rms radial velocity variations in HD 101501 are well modeled with a GP stellar activity model without planets, yielding a residual rms scatter of 45 cm s{sup −1}. We carry out simulations, injecting and recovering signals with the GP framework, to demonstrate that high-cadence observations are required to use GPs most efficiently to detect low-mass planets around active stars like HD 101501. Sparse sampling prevents GPs from learning the correlated noise structure and can allow it to absorb prospective Keplerian signals. We quantify the moderate to high-cadence monitoring that provides the necessary information to disentangle photospheric features using GPs and to detect planets around active stars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GPS-Based Gamma Survey for Characterizing and Decommissioning NORM Sites - 20389

Gamma survey techniques are an especially powerful decommissioning tool at naturally occurring radioactive material (NORM) sites due to both the low cost to obtain data over a large spatial scale and the abundance of gamma emitters in the uranium and thorium decay series. Gamma surveys are executed by coupling a detector - most often a sodium iodide crystal - to a global positioning system (GPS), then reporting a location and gross gamma reading coincidentally to a data logger. Systems may be carried by workers or mounted to a car, all-terrain vehicle, or unmanned aerial system (UAS). The resulting data set provides a high-resolution but low precision map of the gamma radiation field over the area surveyed. Frequently this map is also correlated to soil concentrations of NORM radionuclides (most often, Ra-226) and/or exposure rate. Gamma survey parameters such as movement speed, transect spacing, and data logging frequency define the spatial resolution of the resulting surface, and can be optimized depending on the desired survey sensitivity. This paper examines gamma survey as a tool for decommissioning NORM sites and provides an overview of current gamma survey technology designed to improve the efficiency and effectiveness of the decommissioning process. Topics to be discussed in the paper include: - An overview of gamma survey systems, and the utility of different delivery vehicles depending on desired cost, desired spatial resolution, and site topography. - The influence of physical detector characteristics on detection sensitivity and survey planning. - The tradeoff between high-resolution and large spatial extent, but inherently uncertain data, and low-resolution, low spatial extent, but highly certain data, as well as the specific utility of each of these types of data during NORM facility decommissioning. - Confounding variables that may limit the utility of gamma survey at some sites (e.g., radon gas and spatial heterogeneity / hot spots), and methods to plan for and control these conditions. Results show that the confounding variables, such as radon and data output can greatly influence the overall data quality associated with the decommissioning process. In addition, the use of real-time and aerial survey platforms provides a method for ensuring proper spatial extent of the data. When applied thoughtfully, gamma survey is a powerful tool for detecting NORM radionuclides in the environment and a cost-effective technique for identifying areas requiring remediation. However, entities performing or using gamma survey as a decommissioning tool must be aware of both its advantages and its limitations before basing remediation or regulatory action on gamma survey results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dependence of ion-cyclotron range of frequencies instabilities on species mix and fast-ion distribution: I. Stability

Ion cyclotron emission (ICE) driven by fast ions has the potential to be a reactor relevant diagnostic of confined and escaping fast ions; moreover, controlled experiments in magnetic fusion devices can shed light on similar magnetospheric instabilities below and above the ion cyclotron frequency f ci . Dedicated DIII-D experiments studied instabilities below f ci and at cyclotron harmonics l f ci by injecting thirteen different neutral beam populations into plasmas with different thermal compositions of H, D, and 3He at five different values of toroidal field. High-frequency magnetic loops diagnose mode properties. Each beam type is individually injected for an approximate slowing-down time (~100 ms), resulting in a database of 2529 conditions that are analyzed in frequency bands corresponding to ICE harmonics and < f ci global Alfvén eigenmodes. The sub-cyclotron modes are more unstable at low field and in plasmas with large H concentration. For D injection, first harmonic ICE at f cD is more unstable in hydrogen plasmas but, for H injection, the converse is true (ICE at f cH is more unstable in D), suggesting that thermal same-species ions damp fundamental ICE. ICE stability also depends upon the pitch-angle anisotropy gradient and upon the ‘bump-on-tail’ gradient ∂f/∂v. Although the frequency of unstable ICE in these plasmas always occurs near the central cyclotron frequency, the precise value also depends on the Alfvén speed and beam direction, consistent with the idea that instability occurs for modes that simultaneously satisfy ω ≃ 2πlf ci , the magnetosonic dispersion relation, and the Doppler-shifted resonance condition.

electromagnetic ion cyclotron instabilities↗

Exploring the relationship between deposition method, microstructure, and performance of Nb/Si-based superconducting coplanar waveguide resonators

Superconducting quantum circuits (SQC) are one of the most promising hardware platforms for quantum computing, yet their performance is currently limited by the presence of various structural defects inside the circuit's structure. Despite impressive progress in the past decade, a precise understanding of the origin of these defects from various fabrication processes and their impact on coherence is still lacking. Here, in this study, we performed a comprehensive investigation on the microstructure, superconductivity, and resonator quality factor of Nb films deposited by high-power impulse magnetron sputtering (HiPIMS) and direct current (DC) magnetron sputtering. A suite of characterization techniques, including electron microscopy with spectroscopy, secondary ion mass spectrometry, magneto-optical microscopy, and pump-probe reflectivity spectroscopy is used. We reveal that niobium (Nb) resonators fabricated using HiPIMS exhibit a smaller average grain size, thicker surface oxide with larger thickness variations (rougher surface), and a thicker amorphous Nb/Si interface layer compared to samples deposited by DC sputtering. We identified that the amorphous Nb oxides (mainly located at the Nb surface and along the grain boundaries) and Nb-Si amorphous layers (at the Nb/Si interface) are major and potential sources of two-level system (TLS), while off-stochiometric oxides and suboxides of Nb close to the surface, crystalline defects (i.e., dislocations at grain boundary, point defects introduced during deposition) are main contributors of non-TLS sources. Our findings clarify the relationship between different defects and coherence loss mechanisms, highlighting the importance of material microstructure control on performance optimization in SQC.

36 MATERIALS SCIENCE↗

Enabling Bipolar Membrane Manufacturing Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE↗

Enabling Roll-to-Roll Manufacturing of Bipolar Membranes Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE↗

Molecular Engineering of Emissive Molecular Qubits Based on Spin-Correlated Radical Pairs

Spin chemistry of photogenerated spin-correlated radical pairs (SCRPs) offers a practical approach to control chemical reactions and molecular emissions by using weak magnetic fields. This capability to harness magnetic field effects (MFEs) paves the way for developing SCRPs-based molecular qubits. Here, in this work, we introduce a new series of donor–chiral bridge–acceptor (D–χ–A) molecules that demonstrate significant MFEs on fluorescence intensity and lifetime in solution at room temperature—critical for quantum sensing. By precisely tuning the donor site through torsional locking, distance extension, and planarization, we achieved remarkable control over key quantum properties, including field-response range and line width. In the most responsive systems, emission lifetimes increased by over 200%, and the total emission intensity was modulated by up to 30%. This level of tunability shows the power of synthetic spin chemistry. The rational design principle of optically addressable SCRP-based molecular systems, presented in this work, represents a major leap toward functional synthetic molecular qubits, advancing the field of molecular quantum technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validating automated resonance evaluation with synthetic data

The integrity and precision of nuclear data are crucial for a broad spectrum of applications, from national security and nuclear reactor design to medical diagnostics, where the associated uncertainties can significantly impact outcomes. A substantial portion of uncertainty in nuclear data originates from the subjective biases in the evaluation process, a crucial phase in the nuclear data production pipeline. Recent advancements indicate that automation of certain routines can mitigate these biases, thereby standardizing the evaluation process and enhancing reproducibility. This research aims to provide a methodology, framework, and metrics for the validation of automated nuclear data evaluation software leveraging high-quality synthetic data that closely mimic real experimental observables. An introduced error metric provides a scale and intuitive measure of the evaluation quality by quantifying the estimate’s accuracy and performance across the specified energy range. Synthetic data provides access to experimental observables and underlying resonance parameters, enabling comparison of different evaluations. The methodology is demonstrated using Ta-181 isotope data in the resolved resonance region. The Automated Resonance Identification Subroutine (ARIS), which operates without prior resonance information, was used to test and showcase the framework’s capabilities utilizing the proposed error metrics. The results demonstrate the effectiveness of the proposed approach and framework for optimizing software parameters and testing hypotheses through “what-if” controlled experiments, such as modifying assumptions about experimental conditions or average resonance parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3D radiated power analysis of JET SPI discharges using the Emis3D forward modeling tool

Abstract Precise values for radiated energy in tokamak disruption experiments are needed to validate disruption mitigation techniques for burning plasma tokamaks like ITER and SPARC. Control room analysis of radiated power ( P rad ) on JET assumes axisymmetry, since fitting 3D radiation structures with limited bolometry coverage is an under-determined problem. In mitigated disruptions, radiation is toroidally asymmetric and 3D, due to fast-growing 3D MHD modes and localized impurity sources. To address this problem, Emis3D adopts a physics motivated forward modeling (‘guess and check’) approach, comparing experimental bolometry data to synthetic data from user-defined radiation structures. Synthetic structures are observed with the Cherab modeling framework and a best fit chosen using a reduced χ 2 statistic. 2D tomographic inversion models are tested, as well as helical flux tubes and 3D MHD simulated structures from JOREK. Two nominally identical pure neon shattered pellet injection (SPI) mitigated discharges in JET are analyzed. 2D tomographic inversions with added toroidal freedom are the best fits in the thermal quench (TQ) and current quench (CQ). In the pre-TQ, 2D reconstructions are statistically the best fits, but are likely over-optimized and do not capture the 3D radiation structure seen in fast camera images. The next-best pre-TQ fits are helical structures that extend towards the high-field side, consistent with an impurity flow under the magnetic nozzle effect also observed in JOREK simulations. Whole-disruption radiated fractions of 0.98 + 0.03 / − 0.29 and 1.01 + 0.02 / − 0.17 are found, suggesting that the stored energy may have been fully mitigated by each SPI, although mitigation efficiencies well below ITER and SPARC requirements for high energy pulses are still within the large uncertainties. Emis3D is also used to validate JOREK SPI simulations, and confirms improvements in matching experiment from changes to impurity modeling. Time-dependent toroidal peaking factors are calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recreating Fuel Cell Catalyst Degradation in Aqueous Environments for Identical-Location Scanning Transmission Electron Microscopy Studies

The recent surge in interest of proton exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles increases the demand on the durability of oxygen reduction reaction electrocatalysts used in the fuel cell cathode. This prioritizes efforts aimed at understanding and subsequently controlling catalyst degradation. Identical-location scanning transmission electron microscopy (IL-STEM) is a powerful method that enables precise characterization of degradation processes in individual catalyst nanoparticles across various stages of cycling. Recreating the degradation processes that occur in PEMFC membrane electrode assemblies (MEAs) within the aqueous cell used for IL-STEM experiments is vital for generating an accurate understanding of these processes. In this work, we investigate the type and degree of catalyst degradation achieved by cycling in an aqueous cell compared to a PEMFC MEA. While significant degradation is observed in IL-STEM experiments performed on a traditional Pt catalyst using the standard accelerated stress test potential window (0.6-0.95 VRHE), degradation of a PtCo catalyst designed for heavy-duty vehicle use is very limited compared to that observed in MEAs. We therefore explore various experimental parameters such as temperature, acid type, acid concentration, ionomer content, and potential window to identify conditions that reproduce the degradation observed in MEAs. We find that by extending the cycling potential window to 0.4-1.0 V RHE in an electrolyte containing Pt ions, the degraded particle size distribution and alloy composition better match that observed in MEAs. In particular, these conditions increase the relative contribution of Ostwald ripening, which appears to play a more significant role in the degradation of larger alloy particles supported on high-surface-area carbons than coalescence. Results from this work highlight the potential for discrepancies between ex situ aqueous experiments and MEA tests. While different catalysts may require a unique modification to the AST protocol, strategies provided in this work enable future in situ and identical-location experiments that will play an important role in the development of robust catalysts for heavy-duty vehicle applications.

30 DIRECT ENERGY CONVERSION↗

Structural Mechanism of an Efficacy Photoswitch Targeting the β 2 ‐adrenergic Receptor

The field of photopharmacology develops light-responsive drugs that can modulate protein activity, enabling precise and dynamic investigations of their roles in health and disease. Adrenergic receptors are prominent targets for this approach because they are prototypical G protein-coupled receptors with high clinical relevance in bronchial and cardiovascular diseases. Here, we employed the azobenzene-based compound photoazolol-1 in combination with time-resolved serial crystallography at X-ray free-electron lasers to resolve the molecular mechanisms by which photoswitchable β-blockers modulate activity of the β 2 -adrenoceptor (β 2 AR). Time-resolved structures of the receptor bound to trans-photoazolol-1 (pre-photoconversion), a strained intermediate in the nanosecond range, and the fully photoisomerized cis-photoazolol-1 reveal how isomerization of the azobenzene moiety induces distinct conformational changes within the orthosteric ligand binding pocket. Within seconds, light-excited photoazolol-1 adopts a new binding pose, altering interactions with extracellular loop 2 and shifting the positions of transmembrane helices 5, 6, and 7. Functional assays of β 2 AR in cellular membranes show that photoazolol-1 acts as an efficacy photoswitch, changing from an inverse agonist to a neutral antagonist upon isomerization without leaving the binding pocket. In combination, these findings suggest a molecular mechanism for activity modulation via efficacy photoswitches and provide a framework for designing ligands that exploit light-driven transitions within the binding pocket to achieve spatiotemporal control of receptor function.

G protein-coupled receptors↗

Bimetallic-Derived Catalytic Structures for CO 2 -Assisted Ethane Activation

In recent years, the simultaneous upgrading of CO 2 and ethane has emerged as a promising approach for generating valuable gaseous (CO, H 2 , and ethylene) and liquid (aromatics and C 3 oxygenates) chemicals from the greenhouse gas CO 2 and large-reserved shale gas. The key challenges for controlling product selectivity lie in the selective C-H and C-C bond cleavage of ethane with the assistance of CO 2 . Bimetallic-derived catalysts likely undergo alloying or oxygen-induced segregation under reaction conditions, thus providing diverse types of interfacial sites, e.g., metal/support (M/M'O x ) interface and metal oxide/metal (M'O x /M) inverse interface, that are beneficial for selective CO 2 -assisted ethane upgrading. The alloying extent can be initially predicted by cohesive energy and atomic radius (or Wigner-Seitz radius), while the preference for segregation to form the on-top suboxide can be approximated using the work function, electronegativity, and binding strength of adsorbed oxygen. Furthermore, bimetallic-derived catalysts are typically supported on high surface area oxides. Modifying the reducibility and acidity/basicity of the oxide supports and introducing surface defects facilitate CO 2 activation and oxygen supplies for ethane activation. Using in situ synchrotron characterization and density functional theory (DFT) calculations, we found that the electronic properties of oxygen species influence the selective cleavage of C-H/C-C bonds in ethane, with electron-deficient oxygen over the metal (or alloy) surface promoting nonselective bond scission to produce syngas and electron-enriched oxygen over the metal oxide/metal interface enhancing selective C-H scission to yield ethylene. Here, we further demonstrate that the preferred structures of the catalyst surfaces, either alloy surfaces or metal oxide/metal inverse interfaces, can be controlled through the appropriate choice of metal combinations and their atomic ratios. Through a comprehensive comparison of experimental results and DFT calculations, the selectivity of C-C/C-H bond scission is correlated with the thermodynamically favorable bimetallic-derived structures (i.e., alloy surfaces or metal oxide/metal inverse interfaces) under reaction conditions over a wide range of bimetallic catalysts. These findings not only offer structural and mechanistic insights into bimetallic-derived catalysts but also provide design principles for selective catalysts for CO 2 -assisted activation of ethane and other light alkanes. This Account concludes by discussing challenges and opportunities in designing advanced bimetallic-derived catalysts, incorporating new reaction chemistries for other products, employing precise synthesis strategies for well-defined structures with optimized site densities, and leveraging time/spatial/energy-resolved in situ spectroscopy/scattering/microscopy techniques for comprehensive structural analysis. The research methodologies established here are helpful for the investigation of dynamic alloy and interfacial structures and should inspire more efforts toward the simultaneous upgrading of CO 2 and shale gas.

03 NATURAL GAS↗

Molecular-Level Control over Ionic Conduction and Ionic Current Direction by Designing Macrocycle-Based Ionomers

Poor ionic conductivity of the catalyst-binding, submicrometer- thick ionomer layers in energy conversion and storage devices is a huge challenge. However, ionomers are rarely designed keeping in mind the specific issues associated with nanoconfinement. Here, we designed nature-inspired ionomers (calix-2) having hollow, macrocyclic, calix[4]arene-based repeat units with precise, sub-nanometer diameter. In ≤100 nm-thick films, the in-plane proton conductivity of calix-2 was up to 8 times higher than the current benchmark ionomer Nafion at 85% relative humidity (RH), while it was 1-2 orders of magnitude higher than Nafion at 20-25% RH. Confocal laser scanning microscopy and other synthetic techniques allowed us to demonstrate the role of macrocyclic cavities in boosting the proton conductivity. The systematic self-assembly of calix-2 chains into ellipsoids in thin films was evidenced from atomic force microscopy and grazing incidence small-angle X-ray scattering measurements. Moreover, the likelihood of alignment and stacking of macrocyclic units, the presence of one-dimensional water wires across this macrocycle stacks, and thus the formation of long-range proton conduction pathways were suggested by atomistic simulations. We not only did see an unprecedented improvement in thin-film proton conductivity but also saw an improvement in proton conductivity of bulk membranes when calix-2 was added to the Nafion matrices. Nafion-calix-2 composite membranes also took advantage of the asymmetric charge distribution across calix[4]arene repeat units collectively and exhibited voltage-gating behavior. The inclusion of molecular macrocyclic cavities into the ionomer chemical structure can thus emerge as a promising design concept for highly efficient ion-conducting and ion-permselective materials for sustainable energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gut enterotype-dependent modulation of gut microbiota and their metabolism in response to xanthohumol supplementation in healthy adults

Xanthohumol (XN), a polyphenol found in the hop plant (Humulus lupulus), has antioxidant, anti-inflammatory, prebiotic, and anti-hyperlipidemic activity. Preclinical evidence suggests the gut microbiome is essential in mediating these bioactivities; however, relatively little is known about XN’s impact on human gut microbiota in vivo. We conducted a randomized, triple-blinded, placebo-controlled clinical trial (ClinicalTrials.gov NCT03735420) to determine safety and tolerability of XN in healthy adults. Thirty healthy participants were randomized to 24 mg/day XN or placebo for 8 weeks. As secondary outcomes, quantification of bacterial metabolites and 16S rRNA gene sequencing were utilized to explore the relationships between XN supplementation, gut microbiota, and biomarkers of gut health. Although XN did not significantly change gut microbiota composition, it did re-shape individual taxa in an enterotype-dependent manner. High levels of inter-individual variation in metabolic profiles and bioavailability of XN metabolites were observed. Moreover, reductions in microbiota-derived bile acid metabolism were observed, which were enterotype-dependent. These results suggest interactions between XN and gut microbiota in healthy adults are highly inter-individualized and potentially indicate that XN elicits effects on gut health in an enterotype-dependent manner.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improved precision in As speciation analysis with HERFD-XANES at the As K -edge: the case of As speciation in mine waste

High-energy-resolution fluorescence-detected (HERFD) X-ray absorption near-edge spectroscopy (XANES) is a spectroscopic method that allows for increased spectral feature resolution, and greater selectivity to decrease complex matrix effects compared with conventional XANES. XANES is an ideal tool for speciation of elements in solid-phase environmental samples. Accurate speciation of As in mine waste materials is important for understanding the mobility and toxicity of As in near-surface environments. In this study, linear combination fitting (LCF) was performed on synthetic spectra generated from mixtures of eight measured reference compounds for both HERFD-XANES and transmission-detected XANES to evaluate the improvement in quantitative speciation with HERFD-XANES spectra. The reference compounds arsenolite (As 2 O 3 ), orpiment (As 2 S 3 ), getchellite (AsSbS 3 ), arsenopyrite (FeAsS), kaňkite (FeAsO 4 ·3.5H 2 O), scorodite (FeAsO 4 ·2H 2 O), sodium arsenate (Na 3 AsO 4 ), and realgar (As 4 S 4 ) were selected for their importance in mine waste systems. Statistical methods of principal component analysis and target transformation were employed to determine whether HERFD improves identification of the components in a dataset of mixtures of reference compounds. LCF was performed on HERFD- and total fluorescence yield (TFY)-XANES spectra collected from mine waste samples. Arsenopyrite, arsenolite, orpiment, and sodium arsenate were more accurately identified in the synthetic HERFD-XANES spectra compared with the transmission-XANES spectra. In mine waste samples containing arsenopyrite and either scorodite or kaňkite, LCF with HERFD-XANES measurements resulted in fits with smaller R -factors than concurrently collected TFY measurements. The improved accuracy of HERFD-XANES analysis may provide enhanced delineation of As phases controlling biogeochemical reactions in mine wastes, contaminated soils, and remediation systems.

58 GEOSCIENCES↗

Overview of Quantum Sensing Materials and Techniques for Energy Sector Applications

The energy sector has become increasingly dependent upon highly sensitive sensing devices for a wide range of applications. Variables such as temperature, pH, electromagnetic fields, ions, and pressure must be measured with high precision, often in harsh conditions (e.g. highly corrosive environments due to high temperature, pressure and humidity). These sensors are deployed in infrastructure such as transformers, pipelines, mines, nuclear power plants, and other areas to ensure safe operating conditions and uninterrupted, optimized service. Moreover, new opportunities for sensors have emerged due to the expansion of smart grids/meters, driverless vehicles, and the discovery of new oil, gas, and critical mineral deposits. The continued maturation of quantum sensing technologies offers exciting opportunities for quantum-enhanced measurements within the energy sector that may provide significant improvements in sensitivity beyond the classical limit. Here, an overview of established and emerging quantum materials for sensing applications will be provided, from trapped ions to color centers in diamond and silicon carbide. Associated quantum sensing methods for these materials will be discussed, with an emphasis on platforms that are nearing commercial viability. Specific application opportunities within the energy sector for quantum sensors will then be analyzed, including oil/gas discovery, greenhouse gas emission monitoring, pH and ion sensing, current measurement in electric vehicle batteries, and quantum-enhanced spectroscopy. Remaining barriers, such as quantum sensor platform miniaturization and ruggedization, will also be analyzed. A specific project at the National Energy Technology Laboratory involving the functionalization of qubits using metal-organic frameworks for enhanced quantum sensing will also be highlighted. Here, nitrogen vacancy centers (NV) in nanodiamonds, a commercially available qubit with long coherence times and utilizable quantum properties at room temperature, are encapsulated in a controlled way using the metal-organic framework ZIF-8. The ZIF-8 provides a well-defined, porous scaffold that can be controlled to promote the selective uptake of specific target analytes, such as gas molecules or ions. The quantum sensing performance of this composite material is either preserved or enhanced following ZIF-8 encapsulation; the optically detected magnetic resonance response of the NV nanodiamonds with and without the ZIF-8 coating are identical, while the ZIF-8 coating increases the longitudinal spin relaxation lifetime (T1) of the NV centers, an important parameter for spin relaxometry-based quantum sensing experiments. Taken together, these results demonstrate the importance of qubit functionalization as a crucial step for rationally designing high performance quantum sensors.

Crawford, Scott↗