Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

High-sensitivity Cryogenic Temperature Sensors using Pressurized Fiber Bragg Gratings

Cryogenic temperature sensing was studied using a pressurized fiber Bragg grating (PFBG). The PFBG was obtained by simply applying a small diametric load to a regular fiber Bragg grating (FBG), which was coated with polyimide of a thickness of 11 micrometers. The Bragg wavelength of the PFBG was measured at temperatures from 295 to 4.2 K. A pressure-induced transition occurred at 200 K during the cooling cycle. As a result the temperature sensitivity of the PFBG was found to be nonlinear but reach 24 pm/K below 200 K, more than three times the regular FBG. For the temperature change from 80 K to 10 K, the PFBG has a total Bragg wavelength shift of about 470 pm, 10 times more than the regular FBG. From room temperature to liquid helium temperature the PFBG gives a total wavelength shift of 3.78 nm, compared to the FBG of 1.51 nm. The effect of the coating thickness on the temperature sensitivity of the gratings is also discussed.

Wu, Meng-Chou↗

Modeling of HTTF test PG-26 using RELAP5-3D and SAM

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.

97 MATHEMATICS AND COMPUTING↗

Singly charged energetic helium emitted in solar flares

First direct charge state measurements of 0.41-1.05 MeV per nucleon helium accelerated at the sun reveal surprisingly large abundances of singly ionized helium, with typical He(+)/He(++) ratios between 0.04 and 0.21. This unexpected overabundance of He(+) was observed in each of the three large solar-flare particle events which occurred between 1978 August and 1979 October. The data were obtained with the Max-Planck-Institut/University of Maryland Experiment on board the ISEE-3 spacecraft. The observations suggest either strong coronal temperature inhomogeneities including cool regions of approximately 100,000 K or injection of 'cold' chromospheric/photospheric material into the flare acceleration region.

Hovestadt, D.↗

Space Infrared Telescope Facility (SIRTF) design and thermal analysis

The design and performance characteristics of an observatory are compared with those of a storage dewar. The critical design technologies required to increase cryogen dewar lifetime are discussed. In particular, outer shell temperature, vapor cooled shields, multilayer insulation performance, and tank support systems are analyzed to assess their impact on cryogen lifetime for both the observatory and the storage dewar. The cryogen lifetime and cryogen mass loss rate of the Space Infrared Telescope Facility (SIRTF) are compared with that of the Infrared Astronomy Satellite and the Cosmic Background Explorer Satellite. A 0.1 percent mass loss per day of superfluid helium dewar can be designed using current state-of-the-art dewar technology. Space-based liquid hydrogen and liquid oxygen tanks can be designed for a 5-year lifetime.

Lee, Jeffrey H.↗

Evaluation of mitigation strategies for radioactive fission gases in fluoride-salt-cooled high-temperature reactors

Here, the Fluoride-salt-cooled High-temperature Reactor (FHR) is a promising Generation IV nuclear reactor due to its improved safety design, near atmospheric working pressure, and high electric power conversion efficiency. However, control of radioactive fission gases, such as tritium, is a critical issue in FHRs due to the significantly larger production rate and potentially larger leakage rate of tritium compared to those in Light Water Reactors (LWRs). Therefore, this study proposes two mitigation strategies for tritium in FHRs: Double-Wall Heat eXchanger with a Tritium Carrier (DWHX-TC) option and Single-Wall Heat eXchanger with a Tritium Barrier (SWHX-TB) option. For the DWHX-TC option, two tube surface configurations, i.e., plain and fluted tubes, and four tritium carriers, i.e., helium, FLiBe, FLiNaK, and KF-ZrF 4 , are initially considered, among which the best tube configuration and promising tritium carrier are then selected and used for design optimization of the DWHX. For the SWHX-TB option, two cases, tritium barriers with and without cracks, are investigated in this study. In addition, the two mitigation strategies are evaluated by an in-house, one-dimensional, coupled HEat and MAss Transfer (HEMAT) code developed to predict the leakage rate of tritium in nuclear systems. Our analysis shows that (1) a double-wall configuration using fluted tubes as both the inner and outer tubes is better than other double-wall configurations investigated; (2) helium, as a tritium carrier, is superior to other candidates, including FLiBe, FLiNaK, and KF-ZrF 4 ; (3) the leakage rate of tritium (into the atmosphere) is reduced from 3400 Ci/day, taking the Advanced High-Temperature Reactor (AHTR) as a reference, to 4.0 Ci/day for an optimum design of the DWHX-TC option using helium as the tritium carrier and 1.7 Ci/day for an optimum design of the SWHX-TB option using 30-µm thick silicon carbide (SiC) as the tritium barrier (no cracks); and (4) potential cracks in tritium barriers may significantly deteriorate mass transfer performance of the SWHX-TB option. For example, a cracking rate of 0.1% leads to an increase of 694.1% in the leakage rate under the conditions investigated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cool dark sector, concordance, and a low σ 8

We investigate a cosmological model in which a fraction of the dark matter is atomic dark matter (ADM). This ADM consists of dark versions of the electron and of the proton, interacting with each other and with dark photons just as their light sector versions do, but interacting with everything else only gravitationally. We find constraints given current cosmic microwave background (CMB) and baryon acoustic oscillation (BAO) data, with and without an H 0 prior, and with and without enforcing a big bang nucleosynthesis consistent helium abundance. We find that, at low dark photon temperature, one can have consistency with BAO and CMB data, with a fraction of dark matter that is ADM (f adm ) as large as ~0.1 . Such a large f adm leads to a suppression of density fluctuations today on scales below about 60 Mpc that may be of relevance to the σ 8 tension. Our work motivates calculation of nonlinear corrections to matter power spectrum predictions in the ADM model. Here, we forecast parameter constraints to come from future ground-based CMB surveys, and find that if ADM is indeed the cause of the σ 8 tension, the influence of the ADM, primarily on CMB lensing, will likely be detectable at high significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated Cryocooler Monitor and Control System

A system was designed to automate cryogenically cooled low-noise amplifier systems used in the NASA Deep Space Network. It automates the entire operation of the system including cool-down, warm-up, and performance monitoring. The system is based on a single-board computer with custom software and hardware to monitor and control the cryogenic operation of the system. The system provides local display and control, and can be operated remotely via a Web interface. The system controller is based on a commercial single-board computer with onboard data acquisition capability. The commercial hardware includes a microprocessor, an LCD (liquid crystal display), seven LED (light emitting diode) displays, a seven-key keypad, an Ethernet interface, 40 digital I/O (input/output) ports, 11 A/D (analog to digital) inputs, four D/A (digital to analog) outputs, and an external relay board to control the high-current devices. The temperature sensors used are commercial silicon diode devices that provide a non-linear voltage output proportional to temperature. The devices are excited with a 10-microamp bias current. The system is capable of monitoring and displaying three temperatures. The vacuum sensors are commercial thermistor devices. The output of the sensors is a non-linear voltage proportional to vacuum pressure in the 1-Torr to 1-millitorr range. Two sensors are used. One measures the vacuum pressure in the cryocooler and the other the pressure at the input to the vacuum pump. The helium pressure sensor is a commercial device that provides a linear voltage output from 1 to 5 volts, corresponding to a gas pressure from 0 to 3.5 MPa (approx. = 500 psig). Control of the vacuum process is accomplished with a commercial electrically operated solenoid valve. A commercial motor starter is used to control the input power of the compressor. The warm-up heaters are commercial power resistors sized to provide the appropriate power for the thermal mass of the particular system, and typically provide 50 watts of heat. There are four basic operating modes. "Cool " mode commands the system to cool to normal operating temperature. "Heat " mode is used to warm the device to a set temperature near room temperature. "Pump " mode is a maintenance function that allows the vacuum system to be operated alone to remove accumulated contaminants from the vacuum area. In "Off " mode, no power is applied to the system.

Britcliffe, Michael J.↗

Radiation effects on stress evolution and dimensional stability of large fusion energy structures

Here we assess the effects of neutron irradiation on the deformation and stress evolution of large-scale fusion energy structures. This is accomplished through non-linear finite element structural analysis of the coupled thermal and mechanical fields at the Beginning-Of-Life (BOL), at 45 dpa, and at 90 dpa. Radiation effects include volumetric swelling and the influence of radiation on the mechanical properties. The system studied here is a large section of a full inboard module of an integrated structure comprising the First Wall and Blanket (FW/B) of a Dual Cooled Lithium-Lead (DCLL) energy conversion unit in the Fusion Nuclear Science Facility (FNSF). The structural material is the ferritic/martensitic steel F82H. We analyze several radiation effects phenomena that can lead to significant impact on the mechanical design and lifetime of the structure. These include volumetric swelling effects on the assembly and disassembly of modules and the impact of spatial gradients in neutron damage and helium generation on deformation, stress evolution, and plastic strain accumulation. We show that the stress state is strongly influenced by the accumulation of swelling strains, radiation hardening and softening, and by spatial gradients in displacement damage and helium gas generation. Several key regions in the FW/B structure are identified where severe plastic strains accumulate and may be potential sites for failure, especially during cyclic reactor operations. We finally show that minimum gaps between Inboard (IB) blanket sectors must be present during assembly so as to avoid excessive stress and strain in FW/B modules critical regions and raising chances of failure. A range of structural displacements are shown, from as low as 4 mm at BOL for free side walls to as high as 46 mm at 90 dpa for fully constrained side walls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Buffer Gas Experiments in Mercury (Hg+) Ion Clock

We describe the results of the frequency shifts measured from various buffer gases that might be used as a buffer gas to increase the loading efficiency and cooling of ions trapped in a small mercury ion clock. The small mass, volume and power requirement of space clock precludes the use of turbo pumps. Hence, a hermetically sealed vacuum system, incorporating a suitable getter material with a fixed amount of inert buffer gas may be a practical alternative to the groundbased system. The collision shifts of 40,507,347.996xx Hz clock transition for helium, neon and argon buffer gases were measured in the ambient earth magnetic field. In addition to the above non-getterable inert gases we also measured the frequency shifts due to getterable, molecular hydrogen and nitrogen gases which may be used as buffer gases when incorporated with a miniature ion pump. We also examined the frequency shift due to the low methane gas partial pressure in a fixed higher pressure neon buffer gas environment. Methane gas interacted with mercury ions in a peculiar way as to preserve the ion number but to relax the population difference in the two hyperfine clock states and thereby reducing the clock resonance signal. The same population relaxation was also observed for other molecular buffer gases (N H ,) but at much reduced rate.

mercury ion clock↗

The Fast Modular Reactor (FMR) - Development Plan of a New 50 MWe Gas-cooled Fast Reactor

General Atomics Electromagnetic Systems (GA-EMS) will be developing a new 50-megawatt electric (MWe) fast modular reactor (FMR), under the Department of Energy’s (DOE’s) Advanced Reactor Demonstration Program (ARDP), Advanced Reactor Concepts 2020 (ARC-20) development pathway, that provides safe, carbon free electricity, capable of incremental capacity additions. A modular design allows it to be factory-built and assembled on-site to keep the cost of capital low, while the dry-cooling facilitates siting to complement renewables in nearly any location. GA-EMS is committed to commercialization of the proposed reactor, with a demonstration by 2030, and deployment by the mid-2030s. The ultimate goal of the design is to develop flexible and dispatchable carbon-free power source for the 2035 US electricity market. The GAEMS- led team will verify that simplified characteristics (e.g., inert helium gas coolant, pellet-loaded fuel rod, installation-free of heat sink requirements, small and passive heat removal systems) of the FMR will result in a safe, maintainable, cost-effective, distributed, nuclear energygenerating station. Three key specific project objectives for the next three years include: Development of the conceptual design of the 50- MWe FMR plant, Achievement of Technology Readiness Level (TRL) 4 for key system and component technologies through in-pile tests, out-of-pile tests, and numerical experiments; and Development of robust techno-economic analysis (TEA) and pre-application licensing approach necessary for timely demonstration and eventual commercialization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FDNS code to predict wall heat fluxes or wall temperatures in rocket nozzles

This report summarizes the findings on the NASA contract NAG8-212, Task No. 3. The overall project consists of three tasks, all of which have been successfully completed. In addition, some supporting supplemental work, not required by the contract, has been performed and is documented herein. Task 1 involved the modification of the wall functions in the code FDNS to use a Reynolds Analogy-based method. Task 2 involved the verification of the code against experimentally available data. The data chosen for comparison was from an experiment involving the injection of helium from a wall jet. Results obtained in completing this task also show the sensitivity of the FDNS code to unknown conditions at the injection slot. Task 3 required computation of the flow of hot exhaust gases through the P&W 40K subscale nozzle. Computations were performed both with and without film coolant injection. The FDNS program tends to overpredict heat fluxes, but, with suitable modeling of backside cooling, may give reasonable wall temperature predictions. For film cooling in the P&W 40K calorimeter subscale nozzle, the average wall temperature is reduced from 1750 R to about 1050 R by the film cooling. The average wall heat flux is reduced by a factor of three.

Karr, Gerald R.↗

Advantages of cryopumping with liquid hydrogen instead of helium refrigerators

Open loop hydrogen vaporizers and helium refrigerators are compared for operational complexity, installation and operating cost, and safety requirements. Data from two vacuum chambers using helium refrigerators are used to provide comparative data. In general, the use of hydrogen is attractive in the larger systems, even when extra safety precautions are taken. Emotional resistance to the use of hydrogen because of safety requirements is considered great. However, the experience gained in the handling of large quantities of cryogenics, particularly hydrogen and liquefied natural gases, should be considered in the design of open loop hydrogen cooling systems.

J.W. Anderson↗

Commissioning of a 20 K Helium Refrigeration System for NASA-JSC Chamber A

A new 20 K helium refrigerator installed at NASA Johnson Space Center s Space Environment Simulation Laboratory (SESL) was successfully commissioned and tested in 2012. The refrigerator is used to create a deep space environment within SESL s Chamber A to perform ground testing of the James Webb Space Telescope (JWST). The chamber previously and currently still has helium cryo-pumping panels (CPP) and liquid nitrogen shrouds used to create low earth orbit environments. Now with the new refrigerator and new helium shrouds the chamber can create a deep space environment. The process design, system analysis, specification development, and commissioning oversight were performed by the cryogenics department at Jefferson Lab, while the contracts and system installation was performed by the ESC group at JSC. Commissioning data indicate an inverse coefficient of performance better than 70 W/W for a 18 kW load at 20 K (accounting for liquid nitrogen pre-cooling power) that remains essentially constant down to one third of this load. Even at 10 percent of the maximum capacity, the performance is better than 150 W/W at 20 K. The refrigerator exceeded all design goals and demonstrated the ability to support a wide load range from 10 kW at 15 K to 100 kW at 100 K. The refrigerator is capable of operating at any load temperature from 15 K to ambient with tight temperature stability. The new shroud (36 tons of aluminum) can be cooled from room temperature to 20 K in 24 hours. This paper will outline the process design and commissioning results.

Homan, J.↗

Using Mylar-Insulated Cryopumping Panels to Improve Vacuum Level During Warm Temperature Testing at JSC's Large Thermal Vacuum Facilities

Johnson Space Center’s Space Environment Simulation Lab (SESL) has both Chamber A, the world’s largest purpose-built thermal vacuum chamber capable of creating deep space conditions, and Chamber B, the largest human rated thermal vacuum chamber. A unique design feature of these chambers is the gaseous helium cryopumping panels within the liquid nitrogen shroud. This shroud is used to bring the chamber to cryogenic temperatures while the cryopumping panels trap gasses on its surface area to create a high vacuum environment of 5*10-6 Torr. In preparation for the James Webb Space Telescope (JWST) flight test, a series of functionals required the chamber to run at higher temperatures, and therefore did not need active cooling from the liquid nitrogen shroud. During testing, cryopumping panels were used to mitigate contamination during this main shroud warm-up. One of the cryopumping panels in Chamber A was covered with several layers of aluminized mylar to thermally protect the zone from the warmed shroud. This strategy was effective and became part of operations during JWST testing. Currently, Chamber B has requests for both commercial and NASA space suit tests at both high and low temperatures to validate thermal models. High temperature tests could benefit from reduced heater demand with an insulated shroud while still sustaining the high vacuum environment provided by the cryopumping panels. This paper will quantitatively define the thermal loads on the panels used in previous Chamber A warm up sequences. Additionally, this report will perform thermal analyses to assess the feasibility of adding layers of aluminized mylar to the cryopumping panels of Chamber B.

Cryogenics↗

Stationary Testing of a Pulse Tube Cryocooler Designed to Rotate at 6800 RPM with the Superconducting Rotor of an Electric Machine

Electrified aircraft are being developed to increase the efficiency and reduce the cost of operating subsonic transport aircraft. Achieving a substantial impact necessitates focusing on single- and twin-aisle aircraft which use propulsion systems with >20 MW ratings. For these aircraft, multi-MW superconducting electric machines are being developed due to their high specific power and high efficiency. Most of these electric machines employ superconductors on their rotor, thereby requiring cryogenic cooling of the rotating system. An attractive solution is to conductively cool the rotor using a cryocooler that rotates with the rotor. NASA has been developing a 50 K pulse tube cryocooler for its High Efficiency Megawatt Motor (HEMM) that can operate while rotating at up to 6,800 rpm. The first non-rotating tests of the fully assembled HEMM cryocooler have been completed, and initial testing has yielded a no-load temperature of 112 K. A small helium leak into the vacuum system has been identified as the major bottleneck to performance, and based on measurements with the motor turned off there is an observed vacuum-side heat leak of approximately 30 W at 115 K. Immediate next steps for testing are to locate and mitigate the apparent helium leaks into the vacuum chamber. Thus far, compressor performance and the apparent heat lift after correcting for the heat leak are on par with expectations.

Electrified Aircraft Propulsion↗

Design of a Continuous Pellet Fueling System for Wendelstein 7-X

A continuous pellet fueling system (CPFS) is currently being designed at the Oak Ridge National Laboratory (ORNL) for the long pulse operation of the Wendelstein 7-X (W7-X) stellarator. The purpose of the CPFS is to provide deep continuous fueling for feedback-controlled high-density operation and mitigation of predicted hollow density profiles. As described here, the system will provide the capability to inject cylindrical pellets of solid hydrogen or deuterium into the plasma core, with flexibility to vary the pellet size, velocity, and injection frequency. Pellets are nominally of 3 mm in diameter and have a length between 1 and 4 mm. The heart of the CPFS is a vertically oriented, twin-screw extruder, cooled by three Gifford-McMahon cryocoolers in parallel, designed to form a continuous filament of hydrogen or deuterium. The filament width, which determines the pellet length, can be adjusted by means of a variable nozzle driven by a linear actuator at the base of the extruder. Coupled to the nozzle is a solenoid-operated gas gun and cutter assembly. A pneumatic propellant valve pulses a burst of ~60 bar helium to accelerate the cut pellet into W7-X. Three gaps in the guide tubes provide pumping locations to remove the helium propellant before it reaches the plasma. The maximum velocity of the pellet is limited by its ability to survive navigating the guide tube trajectory intact. A microwave cavity located within the guide tube provides the capability to measure the pellet size and velocity. The mechanical and thermal designs of the W7-X extruder, adjustable nozzle, and gun and cutter assembly design are described. A guide tube design and experimental pellet survivability test results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design and analysis of orbital cryogenic liquid storage and supply systems

A wide variety of orbital cryogenic liquid storage and supply systems are defined in NASA and DOD long-range plans. These systems include small cooling applications, large chemical and electrical orbit transfer vehicles and supply tankers. All have the common requirements of low-g fluid management to accomplish gas-free liquid expulsion and efficient thermal control to manage heat leak and tank pressure. A preliminary design study was performed to evaluate tanks ranging from 0.6 to 37.4 cu m (22 to 1320 cu ft). Liquids of interest were hydrogen, oxygen, methane, argon and helium. Conceptual designs were generated for each tank system and fluid dynamic, thermal and structural analyses were performed for Shuttle compatible operations. Design trades considered the paradox of conservative support structure and minimum thermal input. Orbital performance and weight data were developed, and a technology evaluation was completed.

Eberhardt, R. N.↗

Low gravity thermal stratification of liquid helium on SHOOT

Estimates of the extent and impact of thermal stratification are presented as well as predictions of the behavior of the HeI/HeII boundary. Although thermal stratification of cryogens can be problematic and lead to their inefficient use in low gravity, for SHOOT the occurrence is beneficial both during ground hold and in orbit and presents no hazards. On the ground the parasitic heat load is both reduced and more efficiently removed. In orbit the pumpdown proceeds at a much more rapid rate, allowing orbital operations to begin earlier. The thermal conductivity of the aluminum tank and the normal liquid plus cooling at the liquid/vapor interface as the vapor bubble grows are sufficient to prevent undesirably high vapor pressures in the tank.

Shirron, P. J.↗