A Deep-UV Trigger for Ground-State Ring-Opening Dynamics of 1,3-Cyclohexadiene

While the ring-opening reaction of 1,3-cyclohexadiene upon excitation to the 1B state has been extensively studied, little is known about the reaction dynamics when exciting higher-lying states. The complexity of the potential energy surfaces found in computational studies suggests that the reaction outcome may depend sensitively on the excitation wavelength and the initially prepared electronic state. We explore the photo-induced kinetics of 1,3-cyclohexadiene upon excitation at 200 nm to the 3p state by ultrafast time-resolved, gas-phase X-ray scattering using the Linac Coherent Light Source (LCLS). Analysis of the experimental scattering data, particularly with respect to the anisotropy, and comparison to ab-initio calculations reveals that the excitation leads dominantly to the 3px and 3py Rydberg electronic states, which relax to the ground state with a time constant of 208 ±11 fs. Unlike in the conventional photochemically induced conrotatory electrocyclic reaction observed at lower excitation energies, at 200 nm the majority of the molecules (76 ± 3%) relax to vibrationally hot cyclohexadiene in the ground electronic state. Furthermore, the photoexcitation activates the reaction on the ground electronic state surface. An equilibrium between the hot cyclohexadiene and 1,3,5-hexatriene is reached by a thermal reaction, giving rates for the forward and backward reaction of 174 ±13 ps and 355 ±45 ps, respectively. The scattering pattern of the final hexatriene product reveals a thermal distribution of rotamers about the carbon-carbon single bonds. The rapid decay of the initially excited state back into the ring-closed form allows us to observe a ground state chemical reaction using ultrafast X-ray scattering.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of New g-function Data for Simulating a Novel Shallow Bore Ground Heat Exchanger

Geothermal heat pump (GHP), which is also referred as ground source heat pump, is the most energy-efficient technology for space heating and cooling. However, the application of GHP is hindered by its high initial cost, of which approximately 30% is for the ground heat exchanger (GHE). In recent years, researchers have developed different types of shallow bore ground heat exchangers (SBGHE) intending to reduce the cost of drilling. The ability to predict the thermal response of an SBGHE is critical for sizing SBGHE. While g-functions have been commonly used for predicting the thermal response of conventional vertical bore ground heat exchangers (VBGHE), they cannot be directly used for predicting the performance of SBGHE because they did not account for the impacts of the seasonal variation of the soil temperature along with the depth of an SBGHE. In addition, an SBGHE has a larger thermal mass within the borehole than the VBGHE due to the larger borehole diameter of SBGHE. This study develops new g-function data pairs for a new design of SBGHE, which is named Underground Thermal Battery (UTB). Impacts of the seasonal variation of soil temperature on the thermal response of UTB were accounted for by superposing a time-dependent soil temperature onto the g-functions calculated with a numerical model that assumes constant undisturbed soil temperature. The TOUGH program was used to predict the thermal response of several configurations involving multiple UTBs. The results indicate that the proposed methodology is appropriate to generate g-functions for the UTB, and the g-function value of UTB is much lower than that of VBGHE in the time range of 15 min to 1 year due to the large thermal mass and convection heat transfer within the UTB.

Shi, Liang↗

Vertical Extraction Process Implemented at the 118-K-1 Burial Ground for Removal of Irradiated Reactor Debris from Silo Structures - 12431

The primary objective of a remediation project is the safe extraction and disposition of diverse waste forms and materials. Remediation of a solid waste burial ground containing reactor hardware and irradiated debris involves handling waste with the potential to expose workers to significantly elevated dose rates. Therefore, a major challenge confronted by any remediation project is developing work processes that facilitate compliant waste management practices while at the same time implementing controls to protect personnel. Traditional burial ground remediation is accomplished using standard excavators to remove materials from trenches and other excavation configurations often times with minimal knowledge of waste that will be encountered at a specific location. In the case of the 118-K-1 burial ground the isotopic activity postulated in historic documents to be contained in vertical cylindrical silos was sufficient to create the potential for a significant radiation hazard to project personnel. Additionally, certain reported waste forms posed an unacceptably high potential to contaminate the surrounding environment and/or workers. Based on process knowledge, waste management requirements, historic document review, and a lack of characterization data it was determined that traditional excavation techniques applied to remediation of vertical silos would expose workers to unacceptable risk. The challenging task for the 118-K-1 burial ground remediation project team then became defining an acceptable replacement technology or modification of an existing technology to complete the silo remediation. Early characterization data provided a good tool for evaluating the location of potential high exposure rate items in the silos. Quantitative characterization was a different case and proved difficult because of the large diameter of the silos and the potential for variable density of attenuating soils and waste forms in the silo. Consequently, the most relevant information supporting job planning and understanding of the conditions was the data obtained from the gross gamma meter that was inserted into each casing to provide a rough estimate of dose rates in the tubes. No added value was realized in attempting to quantify the source term and/or associate the isotopic activity with a particular actual waste form (e.g., sludge). Implementing the WRM system allowed monitoring of worker and boundary exposure rates from a distance, maintaining compliance with ALARA principles. This system also provided the project team early knowledge of items being removed that had high exposure rates associated with them, thus creating an efficient method of acknowledging an issue and arriving at a solution prior to having an upset condition. An electronic dosimeter with telemetry capability replaced the excavator mounted AMP-100 system approximately half way through remediation of the silos. Much higher connectivity efficiency was derived from this configuration. Increasing the data feed efficiency additionally led to less interruption of the remediation effort. Early in system testing process a process handicap on the excavator operator was acknowledged. A loss of depth perception resulted when maneuvering the excavator and bucket using the camera feed to an in-cab monitor. Considerable practice and mock-up testing allowed this handicap to be overcome. The most significant equipment failures involved the cable connection to the camera mounted between the clamshell bucket jaws and the video splitter in the excavator cab. Rotation of the clamshell bucket was identified as the cause of cable connection failures because of the cyclic twisting motion and continuous mechanical jarring of the connection. In-cab vibration was identified as the culprit in causing connection failures of the video splitter. While these failures were repaired, substantial production time was lost. Ultimately, the decision was made to purchase a second cable and higher quality video splitter eliminate the down time. An engineering improvement for future operations would be inserting cable pig tails at more stressed cable connection points to facilitate rapid change out of the cable should that be required. Overall, the system performed better than expected in a safe and efficient manner. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vertical Transport of Water/Contaminant Due to Intermittent Water Influx on the Ground Surface of Vadose Zone - 20088

For movement of moisture and transport of contaminants in the vertical direction, two equations, the Richards equation and the advection-dispersion equation, are solved in a vadose zone for prescribed water and contaminant influx conditions at the ground surface. Two different boundary conditions are considered, one with a single peak of sinusoidal variation and four peaks of finite duration, each of which is sinusoidal in shape. The moisture migration is solved and then the contaminant transport, which is coupled to moisture movement, is solved. In the case of a single influx on the ground surface, at first the hydraulic head and moisture content show a peak. Then above the peak and below the ground surface, the peaks tend to die out, showing a tendency to return to the initial state. The vertical profile of concentration also shows a single peak, which soon becomes stagnant because downward water migration is faster than concentration profile movement. In the case of four intermittent array of peaks, the hydraulic head and moisture content profiles tend to merge and combine together. The concentration profiles show appearance of four peaks clearly. However, although the peak value of concentration remains quite constant, the values may vary with the sorption coefficient because of repeated influx of water and contaminant through the top boundary, the ground surface. The penetration depth decreases with an increasing sorption coefficient. (authors)

54 ENVIRONMENTAL SCIENCES↗

The role of air sealing while ground source heat pump system retrofits in the U.S. single-family houses

Widespread commercial adoption of ground source heat pumps (GSHP) is hindered by the relatively high initial cost associated with drilling boreholes in the ground to deploy ground heat exchangers. Reducing the energy demand of buildings has the potential to reduce the required borehole length and the associated drilling costs. In single-family residential buildings, air sealing can significantly lower heating energy usage, according to recent studies and reports. Thus, air sealing in conjunction with GSHP retrofits can lower the required GSHP system's capacity and borehole length to meet the thermal demands of the buildings. In order to understand the role of combining air sealing with GSHP retrofit quantitatively, the current study employs a whole building energy simulation tool integrated with an advanced design tool for the ground heat exchanger to determine changes in required GSHP capacity, total borehole length, and building energy consumption for with- and without-air sealing in single-family houses in 3 climate zones in the United States. The study considers one representative city for each climate zone, Phoenix, AZ for a hot climate, Seattle, WA for a moderate climate, and Minneapolis, MN for a cold climate. The results from this study show that reducing air infiltration from 0.8 ACH to the minimum ventilation requirement (0.35 ACH) can reduce borehole length requirement by up to 24% in Phoenix, 32% in Seattle, and 70% in Minneapolis. A similar magnitude of reduction can be seen for GSHP capacity and total building energy usage as well.

Prem Anand Jayaprabha, Jyothis Anand↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Ground Penetrating Radar in Hydrogeophysics

To meet the needs of a growing population and to provide us with a higher quality of life, increasing pressures are being placed on our environment through the development of agriculture, industry, and infrastructures. Soil erosion, groundwater depletion, salinization, and pollution have been recognized for decades as major threats to ecosystems and human health. More recently, the progressive substitution of fossil fuels by biofuels for energy production and climate change have been recognized as potential threats to our water resources and sustained agricultural productivity. The vadose zone mediates many of the processes that govern water resources and quality, such as the partition of precipitation into infiltration and runoff , groundwater recharge, contaminant transport, plant growth, evaporation, and energy exchanges between the Earth's surface and its atmosphere. It also determines soil organic carbon sequestration and carbon-cycle feedbacks, which could substantially impact climate change. The vadose zone's inherent spatial variability and inaccessibility precludes direct observation of the important subsurface processes. In a societal context where the development of sustainable and optimal environmental management strategies has become a priority, there is a strong prerequisite for the development of noninvasive characterization and monitoring techniques of the vadose zone. In particular, hydrogeophysical approaches applied at relevant scales are required to appraise dynamic subsurface phenomena and to develop optimal sustainability, exploitation, and remediation strategies. Among existing geophysical techniques, ground penetrating radar (GPR) technology is of particular interest for providing high-resolution subsurface images and specifically addressing water-related questions. Ground penetrating radar is based on the transmission and reception of VHF-UHF (30-3000 MHz) electromagnetic waves into the ground, whose propagation is determined by the soil electromagnetic properties and their spatial distribution. As the dielectric permittivity of water overwhelms the permittivity of other soil components, the presence of water in the soil principally governs GPR wave propagation. Therefore, GPR-derived dielectric permittivity is usually used as surrogate measure for soil water content. In the areas of unsaturated zone hydrology and water resources, GPR has been used to identify soil stratigraphy, to locate water tables, to follow wetting front movement, to estimate soil water content, to assist in subsurface hydraulic parameter identification, to assess soil salinity, and to support the monitoring of contaminants. The purpose of this special section of the Vadose Zone Journal is to present recent research advances and applications of GPR in hydrogeophysics, with a particular emphasis on vadose zone investigations. This special section includes contributions presented at the European Geosciences Union General Assembly 2006 (EGU 2006, Vienna, Austria) and the 11th International Conference on Ground Penetrating Radar (GPR 2006, Columbus, OH). The studies presented here deal with a wide range of surface and borehole GPR applications, including GPR sensitivity to contaminant plumes, new methods for soil water content determination, three-dimensional imaging of the subsurface, time-lapse monitoring of hydrodynamic events and inversion techniques for soil hydraulic properties estimation, and joint interpretation of GPR and electric resistivity tomography (ERT) data.

54 ENVIRONMENTAL SCIENCES↗

Kinetic and electron-electron energies for convex sums of ground state densities with degeneracies and fractional electron number

Properties of exact density functionals provide useful constraints for the development of new approximate functionals. This paper focuses on convex sums of ground-level densities. It is observed that the electronic kinetic energy of a convex sum of degenerate ground-level densities is equal to the convex sum of the kinetic energies of the individual degenerate densities. (The same type of relationship holds also for the electron-electron repulsion energy.) This extends a known property of the Levy-Valone Ensemble Constrained-Search and the Lieb Legendre-Transform refomulations of the Hohenberg-Kohn functional to the individual components of the functional. Moreover, we observe that the kinetic and electron-repulsion results also apply to densities with fractional electron number (even if there are no degeneracies), and we close with an analogous point-wise property involving the external potential. Examples where different degenerate states have different kinetic energy and electron-nuclear attraction energy are given; consequently, individual components of the ground state electronic energy can change abruptly when the molecular geometry changes. These discontinuities are predicted to be ubiquitous at conical intersections, complicating the development of universally applicable density-functional approximations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ground Source Heat Pump Screening Tool and Related Resources

This archive contains both a link to Oak Ridge National Laboratory's Ground Source Heat Pump (GSHP) Screening Tool and related resources documenting its development, technical features, and applications. The web-based screening tool is a techno-economic analysis resource designed to evaluate the feasibility, costs, and benefits of implementing GSHP systems in buildings across various U.S. climate zones. It is intended for use by building owners, HVAC system designers, and installers to support decision-making in residential and commercial applications, incorporating advanced modeling capabilities such as ground heat exchanger design. The included resources detail the tool's creation and use, covering topics such as innovative ground heat exchanger design methodologies, the development of an open library of g-functions for borehole configurations, and studies on GSHP performance and economic viability in retrofitting single-family homes.

15 GEOTHERMAL ENERGY↗

Cleanup Verification Package for the 118-B-1, 105-B Solid Waste Burial Ground

This cleanup verification package documents completion of remedial action, sampling activities, and compliance criteria for the 118-B-1, 105-B Solid Waste Burial Ground. This waste site was the primary burial ground for general wastes from the operation of the 105-B Reactor and P-10 Tritium Separation Project and also received waste from the 105-N Reactor. The burial ground received reactor hardware, process piping and tubing, fuel spacers, glassware, electrical components, tritium process wastes, soft wastes and other miscellaneous debris.

100B/C Area↗

Cleanup Verification Package for the118-F-2 Burial Ground

This cleanup verification package documents completion of remedial action, sampling activities, and compliance with cleanup criteria for the 118-F-2 Burial Ground. This burial ground, formerly called Solid Waste Burial Ground No. 1, was the original solid waste disposal site for the 100-F Area. Eight trenches contained miscellaneous solid waste from the 105-F Reactor and one trench contained solid waste from the biology facilities.

100F Area↗

Microtopographic and depth controls on active layer chemistry in Arctic polygonal ground

Polygonal ground is a signature characteristic of Arctic lowlands, and carbon release from permafrost thaw can alter feedbacks to Arctic ecosystems and climate. This study describes the first comprehensive spatial examination of active layer biogeochemistry that extends across high- and low-centered, ice wedge polygons, their features, and with depth. Water chemistry measurements of 54 analytes were made on surface and active layer pore waters collected near Barrow, Alaska, USA. Significant differences were observed between high- and low-centered polygons suggesting that polygon types may be useful for landscape-scale geochemical classification. However, differences were found for polygon features (centers and troughs) for analytes that were not significant for polygon type, suggesting that finer-scale features affect biogeochemistry differently from polygon types. Depth variations were also significant, demonstrating important multidimensional aspects of polygonal ground biogeochemistry. These results have major implications for understanding how polygonal ground ecosystems function, and how they may respond to future change.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Ground Truth Program: Simulations as Test Beds for Social Science Research Methods.

Social systems are uniquely complex and difficult to study, but understanding them is vital to solving the world’s problems. The Ground Truth program developed a new way of testing the research methods that attempt to understand and leverage the Human Domain and its associated complexities. The program developed simulations of social systems as virtual world test beds. Not only were these simulations able to produce data on future states of the system under various circumstances and scenarios, but their causal ground truth was also explicitly known. Research teams studied these virtual worlds, facilitating deep validation of causal inference, prediction, and prescription methods. The Ground Truth program model provides a way to test and validate research methods to an extent previously impossible, and to study the intricacies and interactions of different components of research.

97 MATHEMATICS AND COMPUTING↗

Tuning the Ground State and Its Relationship to Zero-Field-Cooled Exchange Bias in NiMnSnAl Alloys

The crystal structure, phase transitions, and exchange bias (EB) in Al-doped Ni{sub 50}Mn{sub 36}Sn{sub 14-x}Al{sub x} Heusler alloys were investigated. With the increase of Al content, the cell volume decreases gradually, and the martensitic transformation temperature shifts to a higher temperature. Due to the positive “chemical pressure” by Al substitution, the antiferromagnetic interaction strengthens, leading to the decrease of magnetization and the ground state evolution from “reentrant” spin glass to spin glass. Zero-field-cooled EB is triggered in samples exhibiting spin-glass ground state. These results suggest a viable way to design Ni-Mn-Z-based alloys showing zero-field-cooled EB by tuning the exchange interactions and ground state via lattice modulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Axial and reflection asymmetry of the nuclear ground state

More than a decade ago we published a calculation of nuclear ground-state masses and deformations in Atomic Data and Nuclear Data Tables [P. Moeller, J.R. Nix, W.D. Myers, W.J. Swiatecki, At. Data Nucl. Data Tables 59 (1995) 185]. In this study, triaxial nuclear shapes were not considered. We have now enhanced our model and studied the influence of triaxial shape degrees of freedom on the nuclear ground-state potential-energy (mass) and ground-state shape. It turns out that a few hundred nuclei are affected to a varying degree with the largest effect, about 0.7 MeV, occurring near {sup 108}Ru. We provide here a table of the calculated effects of triaxial shape degrees of freedom. Although axial-asymmetry effects were not considered in the 1995 mass calculation, it did study the effects of reflection-asymmetric shape degrees of freedom ({epsilon}{sub 3}) on nuclear masses. However, the magnitude of the effect was not tabulated. Here, we provide such a table. In addition we calculate the effect in a much improved fashion: we search a four-dimensional deformation space ({epsilon}{sub 2}, {epsilon}{sub 3}, {epsilon}{sub 4}, and {epsilon}{sub 6}). This is now possible because the computational resources available to us today are more than 100,000 times better than at the time we calculated the mass table published in 1995.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A study of the ground-state energy of {sup 4}He with nucleon-nucleon potentials

Ground-state properties are evaluated for the finite nucleus {sup 4}He starting from realistic nucleon-nucleon interactions within the framework of the Green's function approach. For the sake of comparison, the same calculations are performed using the Brueckner-Hartree-Fock approximation. For that purpose four high-quality modern nucleon-nucleon interactions represented in momentum space are employed: the Argonne V18, CD-Bonn, Bonn A and N{sup 3}LO potentials. In these potentials, the effects of charge dependence are taken into account. Additional binding energy is obtained from the inclusion of the hole-hole scattering term within the framework of the Green function approach. It has been shown that the Green function results agree well with the results obtained by accurate methods for few-nucleon systems such as the Faddeev-Yakubovsky calculation. In this study, a comparison of the calculated ground-state energies, obtained by using the Green function approach and different nucleon-nucleon potentials, with experimental values is carried out. The results show good agreement between the calculated values and the experimental ones. - Highlights: > We present ground-state energies of the helium nucleus. > We consider four high-quality modern nucleon-nucleon potentials. > It is shown that the Green function approach gives quite good results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Arsenic cycling within the water column of a small lake receiving contaminated ground-water discharge

The fate of arsenic discharged from contaminated ground water to a small, shallow lake at a hazardous waste site was examined to understand the role of iron (hydr)oxide precipitation-dissolution processes within the water column. Field and laboratory observations indicate that arsenic solubility was controlled, in part, by the extent of ferrous iron oxidation-precipitation and arsenic sorption occurring near the lake chemocline. Laboratory experiments were conducted using site-derived water to assess the impact of these coupled processes on the removal of dissolved arsenic from the water column. The measured concentration of organic carbon from epilimnetic and hypolimnetic water sampled from the lake was approximately 1.3 mM and 17.0 mM, respectively. Experiments conducted with these samples along with synthetic controls containing no organic carbon demonstrated that observed rates of formation and crystallinity of the precipitated iron (hydr)oxide were dependent on the concentration of organic carbon in the lake water. Increasing dissolved organic matter concentration did not significantly interfere with ferrous iron oxidation, but inhibited iron (hydr)oxide precipitation and subsequent sorption of arsenic. For experiments using water sampled from the lake hypolimnion there was a strong relationship between the fraction of precipitated iron and the fraction of sorbed arsenic. Laboratory- and field-derived iron (hydr)oxide precipitates were characterized to evaluate mineralogy and arsenic distribution. In-situ suspended solids and precipitates formed in laboratory experiments using hypolimnetic water were identified as poorly crystalline 2-line ferrihydrite. These solids were readily dissolved in the presence of dithionite indicating that elevated dissolved iron and arsenic observed in the hypolimnion resulted, in part, from in-situ reductive dissolution of settling 2-line ferrihydrite near the sediment-water interface. These observations support the contention that the levels of dissolved arsenic observed in the shallow lake can be attributed to ground-water discharge and internal recycling of arsenic within the water column. The efficiency of the process resulting in iron (hydr)oxide precipitation and arsenic sorption limits the downgradient export of arsenic derived from ground-water discharge.

54 ENVIRONMENTAL SCIENCES↗

A Method for Assessing Ground-Truth Accuracy of the 5DCT Technique

Purpose: To develop a technique that assesses the accuracy of the breathing phase-specific volume image generation process by patient-specific breathing motion model using the original free-breathing computed tomographic (CT) scans as ground truths. Methods: Sixteen lung cancer patients underwent a previously published protocol in which 25 free-breathing fast helical CT scans were acquired with a simultaneous breathing surrogate. A patient-specific motion model was constructed based on the tissue displacements determined by a state-of-the-art deformable image registration. The first image was arbitrarily selected as the reference image. The motion model was used, along with the free-breathing phase information of the original 25 image datasets, to generate a set of deformation vector fields that mapped the reference image to the 24 nonreference images. The high-pitch helically acquired original scans served as ground truths because they captured the instantaneous tissue positions during free breathing. Image similarity between the simulated and the original scans was assessed using deformable registration that evaluated the pointwise discordance throughout the lungs. Results: Qualitative comparisons using image overlays showed excellent agreement between the simulated images and the original images. Even large 2-cm diaphragm displacements were very well modeled, as was sliding motion across the lung–chest wall boundary. The mean error across the patient cohort was 1.15 ± 0.37 mm, and the mean 95th percentile error was 2.47 ± 0.78 mm. Conclusion: The proposed ground truth–based technique provided voxel-by-voxel accuracy analysis that could identify organ-specific or tumor-specific motion modeling errors for treatment planning. Despite a large variety of breathing patterns and lung deformations during the free-breathing scanning session, the 5-dimensionl CT technique was able to accurately reproduce the original helical CT scans, suggesting its applicability to a wide range of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗