Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Generation of bright isolated attosecond soft X-ray pulses driven by multicycle midinfrared lasers

High harmonic generation driven by femtosecond lasers makes it possible to capture the fastest dynamics in molecules and materials. However, to date the shortest subfemtosecond (attosecond, 10-18 s) pulses have been produced only in the extreme UV region of the spectrum below 100 eV, which limits the range of materials and molecular systems that can be explored. Here we experimentally demonstrate a remarkable convergence of physics: when midinfrared lasers are used to drive high harmonic generation, the conditions for optimal bright, soft X-ray generation naturally coincide with the generation of isolated attosecond pulses. The temporal window over which phase matching occurs shrinks rapidly with increasing driving laser wavelength, to the extent that bright isolated attosecond pulses are the norm for 2-μm driving lasers. Harnessing this realization, we experimentally demonstrate the generation of isolated soft X-ray attosecond pulses at photon energies up to 180 eV for the first time, to our knowledge, with a transform limit of 35 attoseconds (as), and a predicted linear chirp of 300 as. Most surprisingly, advanced theory shows that in contrast with as pulse generation in the extreme UV, long duration, 10-cycle, driving laser pulses are required to generate isolated soft X-ray bursts efficiently, to mitigate group velocity walk-off between the laser and the X-ray fields that otherwise limit the conversion efficiency. Furthermore, our work demonstrates a clear and straightforward approach for robustly generating bright isolated attosecond pulses of electromagnetic radiation throughout the soft X-ray region of the spectrum.

74 ATOMIC AND MOLECULAR PHYSICS↗

A novel property of gold nanoparticles: Free radical generation under microwave irradiation

Purpose: Gold nanoparticles (GNPs) are known to be effective mediators in microwave hyperthermia. Interaction with an electromagnetic field, large surface to volume ratio, and size quantization of nanoparticles (NPs) can lead to increased cell killing beyond pure heating effects. The purpose of this study is to explore the possibility of free radical generation by GNPs in aqueous media when they are exposed to a microwave field. Methods: A number of samples with 500 mM 5,5-dimethyl-1-pyrroline N-oxide (DMPO) in 20 ppm GNP colloidal suspensions were scanned with an electron paramagnetic resonance (EPR)/electron spin resonance spectrometer to generate and detect free radicals. A fixed (9.68 GHz) frequency microwave from the spectrometer has served for both generation and detection of radicals. EPR spectra obtained as first derivatives of intensity with the spectrometer were double integrated to get the free radical signal intensities. Power dependence of radical intensity was studied by applying various levels of microwave power (12.5, 49.7, and 125 mW) while keeping all other scan parameters the same. Free radical signal intensities from initial and final scans, acquired at the same power levels, were compared. Results: Hydroxyl radical (OH⋅) signal was found to be generated due to the exposure of GNP–DMPO colloidal samples to a microwave field. Intensity of OH⋅ signal thus generated at 12.5 mW microwave power for 2.8 min was close to the intensity of OH⋅ signal obtained from a water–DMPO sample exposed to 1.5 Gy ionizing radiation dose. For repeated scans, higher OH⋅ intensities were observed in the final scan for higher power levels applied between the initial and the final scans. Final intensities were higher also for a shorter time interval between the initial and the final scans. Conclusions: Our results observed for the first time demonstrate that GNPs generate OH⋅ radicals in aqueous media when they are exposed to a microwave field. If OH⋅ radicals can be generated close to deoxyribonucleic acid of cells by proper localization of NPs, NP-aided microwave hyperthermia can yield cell killing via both elevated temperature and free radical generation.

60 APPLIED LIFE SCIENCES↗

GET-Solar (Generation forecasting and parameter Estimation Tool for Solar) [SWR-20-115]

GET-Solar (Generation forecasting and parameter Estimation Tool for Solar) can be used to estimate behind the meter (BTM) solar generation from limited datasets. Using distributed sets of diverse solar sites, but with close spatial proximity, and/or limited historical PV generation information can be used to generate of solar profiles. This is useful for applications where partial solar generation data is available, and on-site irradiance data is not available. GET-Solar calculates PV technical data parameters and calculates output by modeling shading and cloud cover impacts. Clear sky irradiance profiles are used to calculate base generation profiles on which the local shading and cloud cover layers are added. In order to arrive at clear sky generation data, PV mounting information like panel tilt and and angle is needed. For cases where PV mounting information is missing, panel tilt and azimuth angle can be estimated using a non-linear optimization algorithm. GET-Solar can also be used for forecasting applications where historical PV data is available to estimate local shading at various solar positions. This overall framework can be used for estimation of solar parameters, and assisting in analyzing and modeling diverse sets of DER where solar generation is also present in utility meter data. GET-Solar has been developed in Python and uses the Pyomo optimization language.

Abraham, Sherin Ann↗

Dynamic Retrieval Augmented Generation of Ontologies using Artificial Intelligence (DRAGON-AI)

Ontologies are fundamental components of informatics infrastructure in domains such as biomedical, environmental, and food sciences, representing consensus knowledge in an accurate and computable form. However, their construction and maintenance demand substantial resources and necessitate substantial collaboration between domain experts, curators, and ontology experts. We present Dynamic Retrieval Augmented Generation of Ontologies using AI (DRAGON-AI), an ontology generation method employing Large Language Models (LLMs) and Retrieval Augmented Generation (RAG). DRAGON-AI can generate textual and logical ontology components, drawing from existing knowledge in multiple ontologies and unstructured text sources.We assessed performance of DRAGON-AI on de novo term construction across ten diverse ontologies, making use of extensive manual evaluation of results. Our method has high precision for relationship generation, but has slightly lower precision than from logic-based reasoning. Our method is also able to generate definitions deemed acceptable by expert evaluators, but these scored worse than human-authored definitions. Notably, evaluators with the highest level of confidence in a domain were better able to discern flaws in AI-generated definitions. We also demonstrated the ability of DRAGON-AI to incorporate natural language instructions in the form of GitHub issues.These findings suggest DRAGON-AI's potential to substantially aid the manual ontology construction process. However, our results also underscore the importance of having expert curators and ontology editors drive the ontology generation process.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Recovery Act: Johnston Rhode Island Combined Cycle Electric Generating Plant Fueled by Waste Landfill Gas

The primary objective of the Project was to maximize the productive use of the substantial quantities of waste landfill gas generated and collected at the Central Landfill in Johnston, Rhode Island. An extensive analysis was conducted and it was determined that utilization of the waste gas for power generation in a combustion turbine combined cycle facility was the highest and best use. The resulting project reflected a cost effective balance of the following specific sub-objectives. 1) Meet environmental and regulatory requirements, particularly the compliance obligations imposed on the landfill to collect, process and destroy landfill gas. 2) Utilize proven and reliable technology and equipment. 3) Maximize electrical efficiency. 4) Maximize electric generating capacity, consistent with the anticipated quantities of landfill gas generated and collected at the Central Landfill. 5) Maximize equipment uptime. 6) Minimize water consumption. 7) Minimize post-combustion emissions. To achieve the Project Objective the project consisted of several components. 1) The landfill gas collection system was modified and upgraded. 2) A State-of-the Art gas clean up and compression facility was constructed. 3) A high pressure pipeline was constructed to convey cleaned landfill gas from the clean-up and compression facility to the power plant. 4) A combined cycle electric generating facility was constructed consisting of combustion turbine generator sets, heat recovery steam generators and a steam turbine. 5) The voltage of the electricity produced was increased at a newly constructed transformer/substation and the electricity was delivered to the local transmission system. The Project produced a myriad of beneficial impacts. 1) The Project created 453 FTE construction and manufacturing jobs and 25 FTE permanent jobs associated with the operation and maintenance of the plant and equipment. 2) By combining state-of-the-art gas clean up systems with post combustion emissions control systems, the Project established new national standards for best available control technology (BACT). 3) The Project will annually produce 365,292 MWh's of clean energy. 4) By destroying the methane in the landfill gas, the Project will generate CO{sub 2} equivalent reductions of 164,938 tons annually. The completed facility produces 28.3 MWnet and operates 24 hours a day, seven days a week.

09 BIOMASS FUELS↗

Electric Grid Expansion Planning with High Levels of Variable Generation

Renewables are taking a large proportion of generation capacity in U.S. power grids. As their randomness has increasing influence on power system operation, it is necessary to consider their impact on system expansion planning. To this end, this project studies the generation and transmission expansion co-optimization problem of the US Eastern Interconnection (EI) power grid with a high wind power penetration rate. In this project, the generation and transmission expansion problem for the EI system is modeled as a mixed-integer programming (MIP) problem. This study analyzed a time series creation method to capture the diversity of load and wind power across balancing regions in the EI system. The obtained time series can be easily introduced into the MIP co-optimization problem and then solved robustly through available MIP solvers. Simulation results show that the proposed time series generation method and the expansion co-optimization model and can improve the expansion result significantly after considering the diversity of wind and load across EI regions. The improved expansion plan that combines generation and transmission will aid system planners and policy makers to maximize the social welfare. This study shows that modelling load and wind variations and diversities across balancing regions will produce significantly different expansion result compared with former studies. For example, if wind is modeled in more details (by increasing the number of wind output levels) so that more wind blocks are considered in expansion planning, transmission expansion will be larger and the expansion timing will be earlier. Regarding generation expansion, more wind scenarios will slightly reduce wind generation expansion in the EI system and increase the expansion of other generation such as gas. Also, adopting detailed wind scenarios will reveal that it may be uneconomic to expand transmission networks for transmitting a large amount of wind power through a long distance in the EI system. Incorporating more details of renewables in expansion planning will inevitably increase the computational burden. Therefore, high performance computing (HPC) techniques are urgently needed for power system operation and planning optimization. As a scoping study task, this project tested some preliminary parallel computation techniques such as breaking down the simulation task into several sub-tasks based on chronology splitting or sample splitting, and then assigning these sub-tasks to different cores. Testing results show significant time reduction when a simulation task is split into several sub-tasks for parallel execution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Integrated Supercritical System for Efficient Produced Water Treatment and Power Generation

The main goal of this project was to evaluate the feasibility of an integrated supercritical (SC) water desalination and power generation system for treatment of produced waters from CO 2 sequestration, oil production, and coal-bed methane recovery. This system may offer a transformative approach to generating power from coal or natural gas (NG) and purifying saline water or produced water with high total dissolved solids (TDS) in a zero-liquid discharge plant. The closed-loop steam cycle of conventional power plants was replaced with an open-loop steam cycle that heated the pretreated produced water above the SC point of water (374 °C and 221 bar) to precipitate and separate the salts dissolved in the water. After separation of the precipitated salt, the SC steam required further treatment to reduce the salt content from ~100 mg/L (ppm) to <1 ppm to make it suitable for use in turbines for power generation. A SC membrane distillation unit was used to polish the SC steam, which could be sent through a series of turbines for power generation, and the steam exiting the low-pressure turbine could be condensed by cooling water to produce pure water. Project tasks included a process simulation and a techno-economic evaluation of the integrated system; design and assembly of SC salt precipitation and membrane distillation systems; development and characterization of advanced carbon membranes for SC membrane distillation; and pretreatment, desalination, and purification of different produced water samples with salt concentrations of 30,000–200,000 ppm to a high-purity (<1 ppm) level. Process simulations were performed for 550 MW SC coal-fired or NG baseline cases and various scenarios for the proposed integrated SC system using produced water as the water source and coal or NG as the fuel source. Simulation results indicated that the net plant efficiency loss of the proposed SC cogeneration process would be in the range of <1% to ~4%, in which NG and lower TDS produced water cases would have higher efficiencies. The proposed process for coal-fired cases could provide all water needs for the power generation process and generate additional pure water for beneficial use. A techno-economic analysis was performed to estimate the cost of produced water treatment (dollars /kgal of treated water) by conventional treatment processes compared with the proposed cogeneration process. The cost estimation for the proposed cogeneration system included the cost of pretreatment, the cost of power loss to integrate the water desalination process into the power generation system, and the cost of plant modification or retrofitting. The cost of produced water treatment was calculated by assuming three different scenarios in which converting a baseline power plant to the proposed cogeneration plant would increase the cost of the boiler and feed water system by 10%, 50%, and 100%. Results indicated that the cost of produced water treatment, even with a 100% cost increase, was in the range of $8.6–11.6 dollars per kgal, which is about half of the treatment cost by conventional methods. The cost of produced water treatment by the proposed cogeneration system could be further reduced or a considerable income could be generated if the values of saltwater and freshwater products are considered. Overall, the techno-economic analysis results indicated that the proposed integrated SC system could potentially treat produced water at a cost significantly lower than the cost of produced water treatment by conventional technologies. To evaluate the feasibility of the proposed treatment system at a laboratory scale, a SC salt precipitation and membrane distillation system was designed and fabricated to treat a simulated brine or pretreated produced water by precipitating salts and further polishing the SC steam containing ~100 ppm salts to a high-purity steam. Through baseline tests with NaCl solutions, with concentrations ranging from 30,000 to 200,000 ppm, it was demonstrated that concentrated feed solutions could be treated by precipitating salt at SC conditions to a TDS level of 130 ppm. Produced water samples were collected from a potential CO 2 sequestration site, a coal-bed methane site, and an oilfield in Illinois. Representative samples were characterized for various water quality parameters, including pH; turbidity; conductivity; and concentrations of selected anions, cations, alkalinity, dissolved organic carbon, total suspended solids, TDS, and total petroleum hydrocarbons. The produced water samples were first treated by conventional pretreatment methods to remove residual oil, dissolved organic matter, and scale-forming species. Pretreatment methods included coagulation, sedimentation, filtration, activated carbon adsorption, and ion-exchange adsorption. Pretreated produced waters were treated at SC conditions in which salts were precipitated. Analysis of treated samples revealed that the concentration of Na (the main cation) in produced waters was reduced dramatically from 14,000–47,400 ppm in the feed to 21–80 ppm in treated waters. Concentrations of other main cations (Ca, Mg, Sr, K) also decreased significantly from initial values of ~1,000–22,000 ppm to ~1 ppm or less. However, a significant increase in the concentrations of Fe, Ni, Cu, and Co was observed, mainly caused by leaching of these elements from the system (vessels, filters, tubing), which is manufactured from alloys containing Fe, Ni, Cu, and Co. To polish the SC steam containing a salt content of ~100 ppm to a high-purity level of <1 ppm, a SC membrane distillation treatment using carbon membranes was employed. Different types of self-standing or supported carbon membranes were developed from graphite, graphene, carbon nanotubes, carbon nanofibers, and pyrolytic carbon. Screening tests revealed that only a limited number of developed carbon membranes were suitable for the purification of steam at SC conditions. Membranes that were either fragile and lacked mechanical strength or had large pores and showed limited salt rejection (<20%) were found to be unsuitable for the purification of SC steam. Promising carbon membranes that were successfully tested for purifying SC steam included two graphite membranes (i.e., AF-5, a porous graphite material, and FGS, a flexible graphite sheet) and a carbon nanotube membrane grown on a Hastelloy substrate and then further modified using a proprietary method (i.e., membrane C). The AF-5 membrane exhibited a stable water flux of ~50 kg/m 2 ∙h and ~40% salt rejection. The FGS membrane had a high salt rejection of 95%–98% but a lower water flux of ~15 kg/m 2 ∙h. Membrane C showed an extremely high flux of 200-800 kg/m 2 ∙h, which is one order of magnitude higher than the water flux of conventional membranes. Membrane C also exhibited 87%–93% salt rejection. Overall, a two-stage or multistage polishing treatment by these membranes could lower the salt content of the SC steam from initial values of ~100–200 ppm to the steam quality of <1 ppm or to parts per billion levels required for the power cycle.

20 FOSSIL-FUELED POWER PLANTS↗

Versatile D-T Neutron-Generation System for Fast-Neutron Research and Education

In order to stimulate new cutting-edge research and create novel educational tools at the Pennsylvania State University (PSU), the PIs of the project acquired a versatile 14-MeV D-T neutron-generation system. Relatively recent advancements at Lawrence Berkeley National Laboratory (LBNL) have led to the development of high-neutron-output D-T neutron generators. The resulting technology was subsequently licensed to Adelphi Technology, Inc. and 14-MeV D-T neutron-generation systems are currently available with neutron yields up to 10 10 n/sec. Such neutron output has been available previously; however, the existing D-T generators were traditionally million-dollar systems (an example is D711 from Thermo Scientific), thus beyond reach for many users. The Adelphi neutron generators, on the other hand, now provide access to high neutron outputs for a reasonable price. More importantly, the expected lifetime of the D-T system’s tubes is at least 2,000 hours; a factor of two better when compared to D711, with comparable generator-tube replacement cost. Adelphi Technology, the manufacturer of the dual D-T neutron generation system, delivered one 10 8 neutrons/second and one 10 10 neutrons/second D-T generator with two separate control units to PSU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 ga l-1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . ∙ For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. ∙ Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 gal -1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Increased Latent Generations on Sensitivity Calculations with SCALE [Slides]

Depending on the system, energy, and/or nuclide, altering the number of latent generations can significantly impact generated sensitivity coefficients. In general, as the number of latent generations increases, the accuracy of the generated sensitivity value compared with the DP value increases and there is a significant increase in the uncertainty with generated sensitivity values. IFP generated sensitivities appear to be more stable than those with CLUTCH. Complex systems, even with IFP and increased latent generations can still produce poor results (i.e., MPC- 32). This reiterates the importance of performing DPs to confirm sensitivities. IFP-Shift and CLUTCH can take advantage of parallel computing abilities. Work continues in this area as additional parameters and calculational methods are examined to provide analysts insights to successfully generating sensitivity coefficients for confirmatory analyses and validation efforts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar media under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): (1) CST in water at 25°C tested to 300 Mrad total dose, (2) wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (3) dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (4) CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose, and (5) CST in 5.6M Na simulant with 1% (w/w) total organic carbon as Na 3 -HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per-component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST-in-water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar media under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): (1) CST in water at 25°C tested to 300 Mrad total dose, (2) wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (3) dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (4) CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose, and (5) CST in 5.6M Na simulant with 1%(w/w) total organic carbon as Na3-HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST in water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air-coupled tsunamis generated from impacts and airbursts: Our understanding before Hunga-Tonga Hunga-Ha'apai

The effort to prevent or mitigate the effects of an impact on Earth is known as planetary defense. A significant component of planetary defense research involves risk assessment. Much of our understanding of the risk from near-Earth objects comes from the geologic record in the form of impact craters, but not all asteroid impacts are crater-forming events. Small asteroids explode before reaching the surface, generating an airburst, and most impacts into the ocean do not penetrate the water to form a crater in the sea floor. The risk from these non-crater-forming ocean impacts and airbursts is difficult to quantify and represents a significant uncertainty in our assessment of the overall threat. We are currently working to better understand impact scenarios that can generate dangerous tsunamis. One of the suggested mechanisms for the production of asteroid–generated tsunamis is by direct coupling of the pressure wave to the water, analogous to the means by which a moving weather front can generate a meteotsunami. To test this hypothesis, we ran a series of airburst simulations and provided time-resolved pressure and wind profiles to use as source functions for tsunami models. We used the CTH hydrocode to model the various airburst scenarios to compare to the results of other simulations and provide time dependent boundary conditions as input to shallow-water wave propagation codes. The strongest and most destructive meteotsunamis are generated by atmospheric pressure oscillations with amplitudes of only a few hPa1 (mbar), corresponding to changes in sea level of a few cm. The resulting wave is strongest when there is a resonance between the ocean and the atmospheric forcing. A Proudman resonance takes place when the atmospheric disturbance’s translational speed (U) equals the longwave phase speed $\sqrt{gh}$ of shallow water wave. Coupling is strongest when the Froude number (Fr=U/c) is unity. A weather front propagates much slower than the speed of sound, so meteotsunamis are most common and dangerous in shallow bodies of water such as the Mediterranean Sea or Lake Michigan. By contrast, the blast wave from an airburst or crater-forming impact propagates at a speed faster than a tsunami in the deepest ocean, and a Proudman resonance cannot be achieved even though the overpressures are orders of magnitude greater. However, blast wave profiles are N-waves in which a sharp shock wave leading to overpressure is followed by a more gradual rarefaction to a much longer-duration underpressure phase. Even though the blast outruns the water wave it is forcing, the tsunami should continue to be driven by the out-of-resonance gradient associated with the suction phase, which may depend strongly on the details of the airburst or impact scenario. The open question is whether there are any conditions under which such an airburst-driven tsunami can be dangerous enough to contribute to the overall impact risk. We have also identified other potential mechanisms for airburst-generated tsunamis: 1) reaction force at the surface from the plume ejected into space, which carries significant momentum, 2) expanding toroidal vortices at the surface, which travel more slowly than the shock wave and can generate a Proudman resonance in relatively shallow ocean (such as continental shelf), and 3) steam explosion from seawater ablation by a “Type II” (Libyan Desert Glass-type) airburst in which the hot vapor jet descends to the surface. On January 15, 2022, the Hunga-Tonga Hunga-Ha’apai volcano, located approximately 60 km north of Tongatapu, the main island of Tonga, violently erupted with a powerful explosion, culminating the period of volcanic activity that started in December of 2021. This event and resulting tsunamis provided an existence proof for the air pressure wave coupling mechanism we proposed. It also suggests that it can be stronger and more significant over much greater distances than we contemplated, leading to global tsunamis associated with impact events on land as well as in the water. Large atmospheric explosions generate global Lamb waves with larger amplitudes, longer periods, and slower speeds than the local and regional blast waves we modeled prior to that event. This paper reviews our analysis and modeling of airburst-driven tsunamis prior to the 2022 Hunga-Tonga Hunga-Ha’apai tsunami, which was the subject of two presentations at the 2023 Planetary Defense Conference and is the subject of another paper currently in preparation.

54 ENVIRONMENTAL SCIENCES↗

Improved Cross Section Generation Capability of Griffin in FY22

The Griffin code is a Multiphysics Object-Oriented Simulation Environment (MOOSE) based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. The code includes a variety of deterministic steady-state transport solvers for fixed source, k-eigenvalue, adjoint, and subcritical multiplication as well as transient solvers for spatial dynamics with the improved quasi-static method. Griffin uses cross section data in the ISOXML format generated from external deterministic or Monte Carlo cross section generation codes. In recent years, the MC 2 -3 modules have been added to Griffin for fast reactor cross section generation, and the self-shielding application programming interface (SSAPI) was implemented in the ISOXML module for thermal reactor cross section generation. The on-the-fly slowing down method and double-heterogeneity treatment have been implemented to SSAPI and verified against particulate fuel-bearing graphite-moderated thermal reactor problems with high accuracy. This year, work has been focused on improving the cross section generation capability of ISOXML and streamlining the cross section generation procedures. In addition, the form function data were added to ISOXML in order to support the pin power reconstruction capability that was newly implemented in Griffin in this fiscal year. To facilitate the cross section generation using MC 2 -3 and SSAPI in Griffin, the cross section generation workflows have been set up for both fast and thermal spectrum reactors. The MOOSE action system tool was devised for fast spectrum problems, and the MOOSE stochastic tool was adopted to the branch calculation procedure for thermal spectrum problems. Meanwhile, to ensure the accuracy of group-constants, the thermal up-scattering kernel calculator accounting for resonance scattering was implemented in ISOXML, demonstrating the accurate computation of a Doppler-broadened scattering kernel of any Legendre order within a reasonable timescale. Other aspects of ISOXML, such as deletion solver and data, documentation, ISOXML file management, and the interface for Mixture, were improved as well.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ELM 1016706669-AA B581 GDE01 Generator Summary pg 4-5 only

The table below shows the general load breakdown for 581GDE01. Although the total connected load exceeds the generator’s 150kW nameplate capacity, the normal configured load during standby power mode is less, which was measured at 81kW, or 54%, during preventive maintenance activities on 12/12/24. The generator’s available spare capacity must account for dynamically changing loads that can increase the total power demand at any time. If the two online VFD’s are operated at full speed the actual standby mode load is estimated to increase by 38kW, which would bring the total configured load during standby power mode to 119kW, or 79%, still within 581GDE01’s acceptable capacity. Per the LLNL Site 200 Generator Consolidation Final Study 2022, “Standby Emergency Generator nameplate ratings are based upon operation with varying load averaging 70% of the nameplate for 200 hours per year. Continuous loading between 70% and 100% will reduce a generator’s expected lifetime before a major overhaul. This is never a problem with Laboratory machines because of conservative application of generators and the reliability of the normal power system combines to keeps the load and hours down”. To achieve optimal performance and prolong generator life, the recommended generator loading is between 40% and 70%, optimally at 70%, which 581GDE01 appropriately falls within.

42 ENGINEERING↗

High-power radio frequency pulse generation and extration based on wakefield excited by an intense charged particle beam in dielectric-loaded waveguides.

Power extraction using a dielectric-loaded (DL) waveguide is a way to generate high-power radio frequency (RF) waves for future particle accelerators, especially for two-beam-acceleration. In a two-beam-acceleration scheme, a low-energy, high-current particle beam is passed through a deceleration section of waveguide (decelerator), where the power from the beam is partially transferred to trailing electromagnetic waves (wakefields); then with a properly designed RF output coupler, the power generated in the decelerator is extracted to an output waveguide, where finally the power can be transmitted and used to accelerate another usually high-energy low-current beam. The decelerator, together with the RF output coupler, is called a power extractor. At Argonne Wakefield Accelerator (AWA), we designed a 7.8GHz power extractor with a circular DL waveguide and tested it with single electron bunches and bunch trains. The output RF frequency (7.8GHz) is the sixth harmonic of the operational frequency (1.3GHz) of the electron gun and the linac at AWA. In single bunch excitation, a 1.7ns RF pulse with 30MW of power was generated by a single 66nC electron bunch passing through the decelerator. In subsequent experiments, by employing different splitting-recombining optics for the photoinjector laser, electron bunch trains were generated and thus longer RF pulses could be successfully generated and extracted. In 16-bunch experiments, 10ns and 22ns RF pulses have been generated and extracted; and in 4-bunch experiments, the maximum power generated was 44MW with 40MW extracted. A 26GHz DL power extractor has also been designed to test this technique in the millimeter-wave range. A power level of 148MW is expected to be generated by a bunch train with a bunch spacing of 769ps and bunch charges of 20nC each. The arrangement for the experiment is illustrated in a diagram. Higher-order-mode (HOM) power extraction has also been explored in a dual-frequency design. By using a bunch train with a bunch spacing of 769ps and bunch charges of 50nC each, 90.4MW and 8.68MW of extracted power levels are expected to be reached at 20.8GHz and 35.1GHz, respectively. In order to improve efficiency in HOM power extraction, a novel technique has been proposed to suppress unintended modes.

43 PARTICLE ACCELERATORS↗

Mitigation of Hydrogen Gas Generation from the Reaction of Water with Uranium Metal in K Basins Sludge

Means to decrease the rate of hydrogen gas generation from the chemical reaction of uranium metal with water were identified by surveying the technical literature. The underlying chemistry and potential side reactions were explored by conducting 61 principal experiments. Several methods achieved significant hydrogen gas generation rate mitigation. Gas-generating side reactions from interactions of organics or sludge constituents with mitigating agents were observed. Further testing is recommended to develop deeper knowledge of the underlying chemistry and to advance the technology aturation level. Uranium metal reacts with water in K Basin sludge to form uranium hydride (UH3), uranium dioxide or uraninite (UO2), and diatomic hydrogen (H2). Mechanistic studies show that hydrogen radicals (H·) and UH3 serve as intermediates in the reaction of uranium metal with water to produce H2 and UO2. Because H2 is flammable, its release into the gas phase above K Basin sludge during sludge storage, processing, immobilization, shipment, and disposal is a concern to the safety of those operations. Findings from the technical literature and from experimental investigations with simple chemical systems (including uranium metal in water), in the presence of individual sludge simulant components, with complete sludge simulants, and with actual K Basin sludge are presented in this report. Based on the literature review and intermediate lab test results, sodium nitrate, sodium nitrite, Nochar Acid Bond N960, disodium hydrogen phosphate, and hexavalent uranium [U(VI)] were tested for their effects in decreasing the rate of hydrogen generation from the reaction of uranium metal with water. Nitrate and nitrite each were effective, decreasing hydrogen generation rates in actual sludge by factors of about 100 to 1000 when used at 0.5 molar (M) concentrations. Higher attenuation factors were achieved in tests with aqueous solutions alone. Nochar N960, a water sorbent, decreased hydrogen generation by no more than a factor of three while disodium phosphate increased the corrosion and hydrogen generation rates slightly. U(VI) showed some promise in attenuating hydrogen but only initial testing was completed. Uranium metal corrosion rates also were measured. Under many conditions showing high hydrogen gas attenuation, uranium metal continued to corrode at rates approaching those observed without additives. This combination of high hydrogen attenuation with relatively unabated uranium metal corrosion is significant as it provides a means to eliminate uranium metal by its corrosion in water without the accompanying hazards otherwise presented by hydrogen generation.

08 HYDROGEN↗