Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geant4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Phase-Space Analysis using Tomography for the Muon g-2 Experiment at Fermilab

In the next decade the Fermilab Muon Campus will host two world class experiments dedicated to the search for signals of new physics. The Muon g-2 experiment will determine with unprecedented precision the anomalous magnetic moment of the muon. The Mu2e experiment will improve by four orders of magnitude the sensitivity on the search for the as-yet unobserved Charged Lepton Flavor Violation process of a neutrinoless conversion of a muon to an electron. Maintaining and preserving a high density of particles in phase-space is an important requirement for both experiments. This paper presents a new experimental method for mapping the transverse phase space of a particle beam based on tomographic principles. We simulate our technique using a GEANT4 based tracking code, to ascertain accuracy of the reconstruction. Then we apply the technique to a series of proof-of-principle simulation tests to study injection and transport of muon beams for the Fermilab Muon Campus.

43 PARTICLE ACCELERATORS↗

Study Of Boosted W-Jets And Higgs-Jets With the SiFCC Detector

We study the detector performance in the reconstruction of hadronically-decaying W bosons and Higgs bosons at very high energy proton colliders using a full GEANT4 simulation of the SiFCC detector. The W and Higgs bosons carry transverse momentum in the multi-TeV range, which results in collimated decay products that are reconstructed as a single jet. We present a measurement of the energy response and resolution of boosted W-jets and Higgs-jets and show the separation of two sub-jets within the boosted boson jet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Vision on the Status and Evolution of HEP Physics Software Tools

This paper represents the vision of the members of the Fermilab Scientific Computing Division's Computational Physics Department (SCD-CPD) on the status and the evolution of various HEP software tools such as the Geant4 detector simulation toolkit, the Pythia and GENIE physics generators, and the ROOT data analysis framework. The goal of this paper is to contribute ideas to the Snowmass 2013 process toward the composition of a unified document on the current status and potential evolution of the physics software tools which are essential to HEP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Spectroscopy

Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal vs. background discrimination and spectral capability, but suffer from poor sensitivity due to geometrical constraints. This weakness can be overcome if both neutron-proton scattering interactions are detected and resolved within one large contiguous active detector volume. We describe here a maximum likelihood approach to event reconstruction in a single-volume system with no optical segmentation and sensitivity to individual optical photons on the surfaces of the scintillator. We present results from a Geant4-based simulation establishing the feasibility of this single-volume neutron scatter camera concept given notional performance of existing photodetector and readout technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MUFFSgenMC: An Open Source Muon Flexible Framework for Spectral Generation for Monte Carlo Applications

A cosmic ray Muon Flexible Framework for Spectral Generation for Monte Carlo Applications (MUFFSgenMC) has been developed to support state-of-the-art cosmic ray muon detection and tomographic applications. The flexible framework allows for easy and fast creation of source terms for popular Monte Carlo applications such as GEANT4 and MCNP, which simplifies the process of simulations. The flexible framework contains a variety of analytical, numerical, and parametric models that capture the main characteristics of the muon energy and angular distributions in the range 0 to 90 and at arbitrary energies. The primary model for muon energy distribution is an implementation of the Smith and Duller phenomenological model. The predictions for muon energies in the range from 1 GeV to 1 TeV and zenith angles 0 to 90 are validated against an extensive series of experimental spectrum measurements. Finally, the open source code available on Matlab’s Mathworks File Exchange (https://www.mathworks.com/matlabcentral/fileexchange/65585-muffsgenmc) was written to allow users to easily modify and expand the code. MUFFSgenMC can facilitate the study of cosmic ray muons for nuclear nonproliferation applications and will enable the development of new muon-based detection and imaging techniques by providing an easy source term generator.

Greulich, Christopher↗

A Study of Muon Collider Background Rejection Criteria in Silicon Vertex and Tracker Detectors

The hit response of silicon vertex and tracking detectors to muon collider beam background and results of a study of hit reducing techniques are presented. The background caused by decays of the 750 GeV/c m+ and m- beams was simulated using the MARS15 program, which included the infrastructure of the beam line elements near the detector and the 10 degree nozzles that shield the detector from this background. The ILCRoot framework, along with the Geant4 program, was used to simulate the hit response of the silicon vertex and tracker detectors to the muon decay background remaining after the shielding nozzles. The background hit reducing techniques include timing, energy deposition, and hit location correlation in the double layer geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Millimeter Event Localization in Bulk Scintillator Crystals

One of the primary goals of scintillator-based gamma-ray detector development is to obtain spatial resolutions in bulk crystals at the millimeter level in all three spatial dimensions. An even more challenging goal is to disentangle multiple simultaneous energy depositions with comparable spatial resolutions. We are exploring a new technique to achieve this level of performance through the use of close-coupled, coded-aperture shadow masks placed between the crystal and a position-sensitive phototransducer. We report on simulations of such a device using Monte Carlo light transport simulations performed with GEANT4. Initial indications are promising; however, the technique will require a very high level of performance from the phototransducer.

Ziock, Klaus-Peter↗

Neutron structure via forward tagging of the $eD\to e^{\prime}NX$ reaction at the Electron-Ion Collider

I report about the status of a Jefferson Lab 2014 LDRD project exploring the physics potential of deep-inelastic scattering on polarized light ions with forward spectator nucleon tagging with the proposed Electron-Ion Collider (EIC). Such measurements offer unique capabilities for precision studies of neutron spin structure, nuclear modifications of partonic structure, and multiple scattering effects at high energies. We simulate the tagged processes on the $D$ as a function of the $Q^2$, $x_{\rm Bj}$, and the spectator momenta. We quantify the effects of the intrinsic motion of beam particles, as well as the EIC detector acceptance and resolution, on the projected observables. We present results of a model-independent extraction of the free neutron structure function $F_2^n$ through on-shell extrapolation in the spectator momentum~\cite{MSargsian}. Comparison of the bound proton structure function $F_2^p$ with the free proton result provides a crucial test of the method and allows for an unambiguous identification of nuclear binding effects. Future work will extend these studies to polarized deuterons (spin structure functions $g_1^n$ and $g_1^p$) and hard exclusive processes (GPDs), and model the final-state detection through a full GEANT4-based simulation.

Park, Kijun↗

Muon-Computed Tomography using POCA Trajectory for Imaging Spent Nuclear Fuel in Dry Storage Casks

Cosmic ray muon-computed tomography (μCT) is a new imaging modality with unique characteristics that can be particularly important for applications in nuclear proliferation detection and international treaty verification. Using cosmic ray muons for nuclear security presents several potential advantages. Among others, muons are generated naturally in the atmosphere, can penetrate high-density materials, and are freely available. No radiological sources are required and consequently there is no associated radiological dose. Recently, the feasibility of using muons for imaging spent nuclear fuel stored in shielded casks has been explored and has been proved beneficial. However, challenges in μCT imaging include low muon flux of ~10,000 muons/m2/min, the effects of multiple Coulomb scattering (MCS) blurring the image, and inefficiency in being able to use all recorded muons for imaging. In this paper, we argue that the use of muon tracing should produce tomographic muon images with improved quality – or more quickly for the same image quality – compared to the case where conventional methods are used. In our paper, we report on the development and assessment of a novel muon tracing method for μCT. The proposed method back projects the muon’s scattering angle into each pixel crossed by its PoCA trajectory then forward projects the variance of the scattering angle in each pixel to detector bins along the muon’s incident horizontal direction. Two scenarios were simulated to assess the expected detection capability of this proposed method. GEANT4 was used to model the main characteristics of 1-60 GeV muons through matter. The simulated images showed an expected improvement in resolution and a reduced the reliance on the muon momentum information compared to a more conventional muon tomography method.

Liu, Zhengzhi↗

Lanthanum Bromide Detector System for Mu2e Stopping Target Monitor

The stopping target monitor (STM) in the Mu2e experiment is used to normalize the muon decay branching ratio in the Mu2e experiment, by estimating the number of muons that have been captured on the Mu2e nuclear target. The STM measures the distinctive muonic atomic transition lines and muonic nuclear excitations produced in the Aluminum Stopping Target of Mu2e. These signals must be disentangled in the presence of high rate Bremsstrahlung and other backgrounds produced in the target. An HPGe detector with fine energy resolution, ~0.1% will be employed but has limited count rate capability, ~20kcps. Time-to-Decision, that is the time to make an estimate of the experiments observed luminosity, is inversely proportional to the signal rate squared. For this reason the STM will also use a Lanthanum Bromide(LaBr3) detector, having ~2% energy resolution but capable of ~1 Mcps counting rate. This higher rate will allow not only an orthogonal verification of the HPGe luminosity measurements, but will also yield much finer luminosity measurements as a function of time because of its significantly higher counting rate capabilities. Geant4 simulations are presented comparing the performance of different sized, LaBr3 crystals. The results highly favor the use of the commercially available right circular cylindrical, 3x3-in. detector. Modifications to the STM design are discussed in order to take full advantage of the LaBr3 high rate and fast decision making capabilities. A preliminary design will be presented for a custom read-out system needed to fulfill these requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Markov Chain Monte Carlo for Uncertainty Quantification in Quantitative Imaging Problems

The Differential Evolution Adaptive Metropolis (DREAM) method, a Markov chain Monte Carlo approach, is used for optimization and uncertainty analysis of a radioactive source/shield system using pixelated measured data generated by radiation imagers, where each pixel in the image contains a gamma-ray spectrum with statistical uncertainty. DREAM uses this spectral information to determine source thickness and source strength while also propagating uncertainty from the measured data to the solution. Using measurements simulated with GEANT4, successful parameter reconstruction is demonstrated on a numerical test case in a slab/shield geometry. In the presence of statistical noise of 5-9%, parameters are calculated to better than 95% with 2σ error bars that generally encompass the actual values. In a test problem with real-world measurements, source strength per energy line is calculated to within 78-97% of the actual value.

Bledsoe, Keith↗

Neutron Radiography Efforts

Presentation describes past, present, and future neutron radiography efforts from May 2019 to June 2022, to include Gemini tests, GEANT4 simulations, neutron radiography at LANSCE, and neutron imaging at the Area 11 DPF facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Cross Section Measurement In The Protodune-SP Experiment

Understanding the detector response to neutrons will be critical for performing neutrino oscillation analyses in the next-generation Deep Underground Neutrino Experiment (DUNE). The DUNE physics program is centered around measuring the neutrino flavor composition as a function of their energy both at the near and the far detector. Neutrinos in the DUNE beam will have energies ranging between 100~MeV and 10~GeV, which is significant, because individual neutrino energies will not be known beforehand and will have to be reconstructed. Neutrino interactions in DUNE will produce leptons and hadrons -- including protons, pions, and neutrons. Neutrons can transport energy away from their origin and sometimes go undetected. In addition to the primary neutrons produced by the neutrino, subsequent interactions of the charged hadrons can result in secondary neutrons. Neutrons are a source of missing energy and will bias the neutrino energy measurement. Currently, there is also a 20\% energy scale uncertainty and a 40\% uncertainty on the energy resolution for neutrons in DUNE, which must be addressed. ProtoDUNE Single-Phase (ProtoDUNE-SP) is a 770-ton prototype for the DUNE far detector and was designed to both validate the technology that will be employed in DUNE and to measure cross sections for the charged hadrons (pions, protons, and kaons) at the relevant energies for DUNE. The ProtoDUNE-SP experiment, therefore, is in a unique position to characterize the secondary neutron component for DUNE. This is achieved by searching for candidate neutron interactions in ProtoDUNE-SP events and using these to facilitate a measurement of the neutron inelastic cross section as well as an estimate of the neutron energy and number. The cross section measurement presented here is based on neutrons produced in 1~GeV, $\pi^+$ events captured in 2018 by ProtoDUNE-SP in accordance with the production and cross section models in the GEANT4 simulation toolkit, version 4.1 0.6p1. T he best-fit neutron inelastic cross section, in the kinetic energy range of 114 to 314~MeV, is $1.24_{-0.08}^{+0.10}$~(stat.~$\oplus$~syst.)~barns.

Rivera, David Orlando↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developing Low Noise, Rad-hard Detectors for Parity Violating Experiments

As parity-violating electron scattering (PVeS) experiments continue to push the frontiers of precision electro-weak asymmetry measurements, the demands on the experimental techniques and apparatus are also pushed. In particular, the need for higher resolution and radiation-hardness of the main integrating detectors has increased over the successive generations of PVeS experiments. The demand for precise measurement of GHz event rates has pushed the field toward the use of thin quartz Cerenkov light based detectors. We have been designing and testing such thin quartz detectors specifically for the upcoming experiments at Jefferson Lab, PREX-II and CREX, but this work also greatly influences the detector development for several future experiments including MOLLER at Jefferson Lab. These are all PVeS experiments that will use the new thin quartz Cerenkov detector design concept for their main asymmetry measurements (as well as for beam monitoring). The new design concept gives not only significant performance improvements compared to its predecessor from PREX-I, but also we have now thoroughly characterized its operational design and performance using a combination of test-beam data and detailed particle and optical Monte Carlo Geant4 simulations. These activities have culminated in the development and implementation of a "bench-marked" Monte Carlo package, QSIM, which constitutes a powerful design tool for present and future PVeS quartz detectors. The benchmarked simulation can replicate real photoelectron distributions (RMS and Mean) from testbeam data with ~5% precision – limited mainly by the systematic uncertainty of the PMT gain measurements.

Villarreal, Carlos Bula Villarreal↗

Simulation of Isotopic Concentrations and Gamma Spectra from Dynamic Fission Sources

A tool was developed to rapidly generate synthetic gamma-ray spectra to evaluate safeguards material control and accounting methods for liquid-fueled molten salt reactors. Molten salt reactor operations pose unique challenges to nuclear safeguards methods and protocols compared to deployed reactors designs (e.g., light water reactors). This research evaluates the use of gamma-ray spectroscopy to monitor fission product isotopic flow through a reactor model to understand expected operations and investigate changes to the spectra with material diversion scenarios. The large design space of molten salt reactors (e.g., liquid-fueled, liquid-cooled, online separations) could potentially lead to many measurement points within the reactor system. The developed analytical tool generates and evaluates synthetic gamma-ray spectra from dynamic reactor simulations by extracting isotopic inventory to generate source terms. An implementation in the Gamma Detector Response and Analysis Software (GADRAS) Application Program Interface (API) uses the source terms, a model of the reactor component, a detector response function, and measurement plan to quickly generate and analyze spectra. Prospective measurements are then evaluated in the more accurate but slower Geant4 simulations. Utilization of the developed modeling tool and analysis of the subsequent spectra enables optimization of collimation, shielding requirements, and expected count rates that are used to determine key measurement points in the modeled reactor design.

O'Brien, Sean↗

Using Cosmic Ray Muons to Assess Geological Characteristics in the Subsurface

Cosmic rays are energetic nuclei and elementary particles that originate from stars and intergalactic events. The interaction of these particles with the upper atmosphere produces a wide range of secondary particles that reach the surface of the earth, of which muons are the most prominent. With enough energy, muons can travel up to a few kilometers beneath the surface of the earth before being stopped completely. The terrestrial muon flux profile and associated zenith angle can be utilized to determine geological characteristics of a location (e.g., rock overburden and density) without having to use conventional methods such as boreholes. This work uses a low-power plastic scintillator-based muon detection system as a prototype for this non-destructive geological assay methodology. Four custom designed 102 cm x 51 cm x 5 cm plastic scintillation panels are used to realize two orthogonal detection planes. Optical photons from each scintillation panel are read using OnSemi J-Series 4x4 silicon photomultiplier (SiPM) arrays in conjunction with preamplifiers. Simultaneous triggers between detectors from two planes indicate a coincidence event which is recorded using the QuarkNet data acquisition system (DAQ) from Fermi National Accelerator Laboratory. A custom detector holder was designed to securely mount the detection system and rotate the panels along the zenith to collect data at variable angles. In order to quantify the systematic uncertainties associated with the detector, such as energy depositions and angular resolution of the detector design, a Monte Carlo (MC) simulation using Geant4 is being developed. Cosmic ray flux prediction will be included in the project by adding the CORSIKA MC code to the simulation toolchain. Simulated and experimental data will drive the development and validation of a reconstruction algorithm that, upon completion, is expected to predict average overburden and rock density. Extended detector exposure to muons can be used as a means to understand changes in the surrounding environment like rock porosity. On the experimental front, muons will initially be measured at the surface, establishing the baseline flux. This is followed by recording the muon flux at variable depths and zenith angles, where the data will be used by the reconstruction algorithm to predict the overburden. The result will be benchmarked against geological surveys. The measured flux data will also be used to benchmark independent and established models. Successful proof-of-concept demonstration of this technology can open doors for long term non-invasive geological monitoring. The detector design, experimental methodology, and the benchmarking efforts are detailed in this work.

Gadey, Harish Reddy↗

Mott Polarimeter Upgrade at Jefferson Lab

A Mott polarimeter with a design optimized for 5.5 MeV/c has been in routine use at the CEBAF accelerator for well over a decade, providing polarization measurements approaching 1\% accuracy. Measurements with different target elements (Au, Ag, Cu) over decades of target thicknesses (100 -- 10,000 angstroms), and beam energies between 2 and 8 MeV allow us to determine the effective analyzing power with a high degree of certainty. Recent and planned improvements in our polarimeter configuration, detectors and data acquisition system, coupled with a low 31 MHz repetition rate beam allow us to distinguish and suppress electrons that do not originate from the target foil. This work coupled with a significant effort to produce a detailed GEANT4 model of the polarimeter is part of an effort to determine systematic uncertainties at the level of the theoretically calculated analyzing power. We describe our activities and a series of planned measurements that will allow us to demonstrate and possibly improve the precision and accuracy of polarization measurements at JLab, as required for future parity violation experiments.

McHugh, M.↗