OECD MCCI Project: 2-D Core Concrete Interaction (CCI) Tests: CCI-5 Quick Look Data Report
Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence for various cooling mechanisms through separate effect tests and data for severe accident code model development, and ii) provide longer-term two-dimensional core-concrete interaction data for code assessment and improvement. At the 3rd PRG Meeting of the MCCI-2 Program, the MB approved activities required to conduct the CCI-5 test with the overall objective of increasing the test section aspect ratio (i.e., test section width/melt depth) to the greatest extent possible to more accurately mock up prototypic conditions. To this end, the project prepared two design documents [3,4] that were submitted to the PRG for review. On this basis, the design was finalized, the apparatus was assembled, and the experiment was conducted on September 25, 2008. Specifications for CCI-5 are provided. The initial corium composition and concrete types are the same as those of CCI-3, but the dimensions and design of the test section are different. In particular, CCI-3 was conducted with a test section that featured two-ablating sidewalls with an initial basemat cross-section of 50 cm x 50 cm, whereas the CCI-5 test section features one ablating concrete sidewall, an opposing MgO refractory sidewall, and a concrete basemat that is initially 50 cm x 79 cm in cross-sectional area. The input power for CCI-5 during the dry ablation phase is specified to be 145 kW, which is based on the requirement of providing an initial ‘prototypic’ heat flux of ~160 kW/m2 across all melt surfaces that are not in contact with insulating sidewall material. This is the same surface heat flux requirement used to specify the total input power for tests CCI-2 through CCI-4. The initial melt depth for CCI-5 is set at 25 cm, which is the same as that used in previous tests. Since the surface area of the CCI-5 basemat is larger than that of previous tests, the initial melt mass to achieve this depth is increased considerably to 590 kg. With these specifications, CCI-5 can be considered a repeat of CCI-3, but with the aspect ratio increased to the greatest extent possible using: i) available hardware and ii) an inert wall that provides a symmetry boundary condition on one side of the test section. The objective of this quick look data report is to provide early thermalhydraulic results from this test. To this end, a summary description of the test apparatus is provided first, followed by descriptions of the test operating procedure and key experiment results. A full length data report that includes the complete set of results of posttest examinations will be provided when that phase of the work is completed.