Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FAST NEUTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

TRISO Fuel Performance: Modeling, Integration into Mainstream Design Studies, and Application to a Thorium-fueled Fusion-Fission Hybrid Blanket

This study focused on creating a new tristructural isotropic (TRISO) coated particle fuel performance model and demonstrating the integration of this model into an existing system of neutronics and heat transfer codes, creating a user-friendly option for including fuel performance analysis within system design optimization and system-level trade-off studies. The end product enables both a deeper understanding and better overall system performance of nuclear energy systems limited or greatly impacted by TRISO fuel performance. A thorium-fueled hybrid fusion-fission Laser Inertial Fusion Energy (LIFE) blanket design was used for illustrating the application of this new capability and demonstrated both the importance of integrating fuel performance calculations into mainstream design studies and the impact that this new integrated analysis had on system-level design decisions. A new TRISO fuel performance model named TRIUNE was developed and verified and validated during this work with a novel methodology established for simulating the actual lifetime of a TRISO particle during repeated passes through a pebble bed. In addition, integrated self-consistent calculations were performed for neutronics depletion analysis, heat transfer calculations, and then fuel performance modeling for a full parametric study that encompassed over 80 different design options that went through all three phases of analysis. Lastly, side studies were performed that included a comparison of thorium and depleted uranium (DU) LIFE blankets as well as some uncertainty quantification work to help guide future experimental work by assessing what material properties in TRISO fuel performance modeling are most in need of improvement. A recommended thorium-fueled hybrid LIFE engine design was identified with an initial fuel load of 20MT of thorium, 15% TRISO packing within the graphite fuel pebbles, and a 20cm neutron multiplier layer with beryllium pebbles in flibe molten salt coolant. It operated at a system power level of 2000 MW th , took about 3.5 years to reach full plateau power, and was capable of an End of Plateau burnup of 38.7 %FIMA if considering just the neutronic constraints in the system design; however, fuel performance constraints led to a maximum credible burnup of 12.1 %FIMA due to a combination of internal gas pressure and irradiation effects on the TRISO materials (especially PyC) leading to SiC pressure vessel failures. The optimal neutron spectrum for the thorium-fueled blanket options evaluated seemed to favor a hard spectrum (low but non-zero neutron multiplier thicknesses and high TRISO packing fractions) in terms of neutronic performance but the fuel performance constraints demonstrated that a significantly softer spectrum would be needed to decrease the rate of accumulation of fast neutron fluence in order to improve the maximum credible burnup the system could achieve.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of random inhomogeneities in the spatial distribution of radiation-induced defect clusters on carrier transport through the thin base of a heterojunction bipolar transistor upon neutron irradiation

We analyze the electron transport through the thin base of a GaAs heterojunction bipolar transistor with regard to fluctuations in the spatial distribution of defect clusters induced by irradiation with a fissionspectrum fast neutron flux. We theoretically demonstrate that the homogeneous filling of the working region with radiation-induced defect clusters causes minimum degradation of the dc gain of the heterojunction bipolar transistor.

36 MATERIALS SCIENCE↗

The isovector imaginary neutron potential: a key ingredient for the r-process nucleosynthesis

The isovector contribution to the imaginary component of the microscopic optical model potential is adjusted on experimental neutron strength function data. Within the Brueckner-Hartree-Fock approximation of Jeukenne-Lejeune-Mahaux, it is shown that experimental data favours a strong isovector component that can have a drastic impact on the radiative neutron capture cross section for neutron-rich nuclei. If confirmed, this result strongly inhibits the resonant capture by exotic nuclei, so that the traditional r-process picture of the fast neutron captures during the nucleosynthesis r-process needs to be revisited in depth.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring neutron spectra in radiotherapy using the nested neutron spectrometer

Purpose: Out-of-field neutron doses resulting from photonuclear interactions in the head of a linear accelerator pose an iatrogenic risk to patients and an occupational risk to personnel during radiotherapy. To quantify neutron production, in-room measurements have traditionally been carried out using Bonner sphere systems (BSS) with activation foils and TLDs. In this work, a recently developed active detector, the nested neutron spectrometer (NNS), was tested in radiotherapy bunkers. Methods: The NNS is designed for easy handling and is more practical than the traditional BSS. Operated in current-mode, the problem of pulse pileup due to high dose-rates is overcome by measuring current, similar to an ionization chamber. In a bunker housing a Varian Clinac 21EX, the performance of the NNS was evaluated in terms of reproducibility, linearity, and dose-rate effects. Using a custom maximum-likelihood expectation–maximization algorithm, measured neutron spectra at various locations inside the bunker were then compared to Monte Carlo simulations of an identical setup. In terms of dose, neutron ambient dose equivalents were calculated from the measured spectra and compared to bubble detector neutron dose equivalent measurements. Results: The NNS-measured spectra for neutrons at various locations in a treatment room were found to be consistent with expectations for both relative shape and absolute magnitude. Neutron fluence-rate decreased with distance from the source and the shape of the spectrum changed from a dominant fast neutron peak near the Linac head to a dominant thermal neutron peak in the moderating conditions of the maze. Monte Carlo data and NNS-measured spectra agreed within 30% at all locations except in the maze where the deviation was a maximum of 40%. Neutron ambient dose equivalents calculated from the authors’ measured spectra were consistent (one standard deviation) with bubble detector measurements in the treatment room. Conclusions: The NNS may be used to reliably measure the neutron spectrum of a radiotherapy beam in less than 1 h, including setup and data unfolding. This work thus represents a new, fast, and practical method for neutron spectral measurements in radiotherapy.

60 APPLIED LIFE SCIENCES↗

A Novel Detector for High Neutron Flux Measurements

Measuring alpha particles from a neutron induced break-up reaction with a mass spectrometer can be an excellent tool for detecting neutrons in a high neutron flux environment. Break-up reactions of {sup 6}Li and {sup 12}C can be used in the detection of slow and fast neutrons, respectively. A high neutron flux detection system that integrates the neutron energy sensitive material and helium mass spectrometer has been developed. The description of the detector configuration is given and it is soon to be tested at iThemba LABS, South Africa.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Innovative Nuclear Materials Outboard-A Project Specimen Preparation Guide

The Innovative Nuclear Materials (INM) Program was recently established by the U.S. Department of Energy (DOE) to develop advanced material technologies for use in nuclear reactors. The INM program is presently focused on researching in-core non-fueled materials for application in fast spectrum nuclear reactors. The widespread deployment of fast reactors continues to be a prominent aspiration for advanced nuclear technology developers. However, companies working to license these reactors have no choice but to rely on historic material technologies since further optimization and advancement of these materials is impeded by the lack of fast neutron irradiation test facilities. INM-OA is a non-fueled drop-in experiment which will irradiate material specimens of interest to fast reactor applications. This experiment will be irradiated at Idaho National Laboratory (INL) in the Advanced Test Reactor (ATR) outboard-A (OA) position during normal and high temperature steady state (HTSS) cycles. It will include material specimens supplied by members of the INM program and will utilize a cadmium-lined basket to filter out incident thermal neutrons, thus simulating a faster neutron energy spectrum. Material specimens will undergo post-irradiation examination including microscopy and mechanical testing. In addition to absorption reactions, fast neutrons cause microstructural damage in materials by atom displacement, which can cause exacerbated changes in physical properties and behavior. Thus, the data obtained from the INM-OA experiment will be crucial for understanding the engineering-scale behavior of reactor materials. This document is intended for the Principal Investigators providing samples for this project. Topics included are a general description of the experiment, the irradiation experiment/capsule design, sample geometries, number of samples to be provided, documentation to be provided, a brief list potentially useful characterization methods that can be leveraged at INL, and other miscellaneous requirements specific to this project. This document is intended for informational use only.

innovative nuclear materials↗

Nuclear recoil scintillation linearity of a high pressure 4 He gas detector

We investigate scintillation linearity of a commercial high pressure 4 He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Monte Carlo simulations were compared to experimental data to determine the linearity of the detector response by comparing the scaling of the energy deposits in the simulations to the detector output. In this analysis, a linear scintillation response corresponds to a consistent value for the scaling factor between simulated energy deposits and experimental data for several different scattering angles. Here we demonstrate that the detector can be used to detect fast neutron interactions down to 83 keV recoil energies and can be used to characterize low-energy neutron sources, one of its potential applications.

47 OTHER INSTRUMENTATION↗

Observation of Gamma Irradiation-Induced Suppression of Reversed Annealing in Neutron Irradiated MCZ Si Detectors

For the development of radiation-hard Si detectors for the SiD BeamCal program for the future ILC (International Linear Collider), n-type MCZ Si detectors have been irradiated first by fast neutrons to flueneces of 1.5 x 1014 and 3 x 1014 neq/cm2, and then by gamma up to 500 Mrad. The motivation of this mixed radiation project is to develop a Si detector that can utilize the gamma/electron radiation that exists in the ICL radiation environment, which also includes neutrons. By using the positive space charge (SC) created by gamma radiation in MCZ Si detectors, one can cancel the negative space charge created by neutrons, thus reducing the overall/net space charge density and therefore the full depletion voltage of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCALE/AMPX multigroup libraries for sodium-cooled fast reactor systems

New multigroup cross section libraries and associated covariance files that are optimized for the analysis of sodium-cooled fast reactors were generated with the AMPX tools distributed with the SCALE code system. These new libraries account for the fast neutron flux spectrum with sufficient resolution of resonances in the higher energy range to reproduce continuous-energy reference results and to provide the basis for sensitivity and uncertainty analyses of fast spectrum systems with the SCALE code system. The performance of the new libraries was investigated in terms of the eigenvalue, the neutron flux and reaction rates in criticality calculations, and the generation of group constants. A library using 302 energy groups and a fast neutron flux spectrum as the weighting function led to very good agreement with reference continuous-energy results. As a result, the performance of the new library was demonstrated in calculations of experiments from the International Criticality Safety Benchmark Evaluation Project handbook.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron response function characterization of 4 He scintillation detectors

Time-of-flight measurements were conducted to characterize the neutron energy response of pressurized 4He fast neutron scintillation detectors for the first time, using the Van de Graaff generator at Ohio University. The time-of-flight spectra and pulse height distributions were measured. This data was used to determine the light output response function, which was found to be linear at energies below 3.5 MeV. The intrinsic efficiency of the detector as a function of incident energy was also calculated: the average efficiency up to 10 MeV was 3.1%, with a maximum efficiency of 6.6% at 1.05 MeV. Furthermore, these results will enable development of neutron spectrum unfolding algorithms for neutron spectroscopy applications with these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of energy correction coefficient for neutron albedo dosimeter. Three approaches

To accurately determine dose, albedo TLD dosimeters require application of a neutron energy correction factor (NECF). Here, in this paper, the results from three different methods were used to determine NECFs. In the first method, NECF values were calculated as a ratio of the known “conventional true” dose and the neutron dose reported by albedo dosimeter(s) irradiated on a phantom. The results from this direct method were utilized for verification of two other methods. The second method used a specially designed device called the Neutron Area Monitor (NAM) model 5. The third method of NECF determination was based on the response of a BF 3 tube under different levels of moderation. The results of this work showed that the Navy-developed Neutron Area Monitor (NAM) model 5 measures NECF values correctly when irradiated with 252 Cf (bare and D 2 O-moderated). This was an important result, because it validated the use of the NAM-5 in nuclear power and marine propulsion reactors, as their neutron energy spectrum is approximated by the field of a Cadmium-coated 30 cm diameter steel sphere of D 2 O moderated 252 Cf. In the case of a broad neutron energy spectrum the 6 Li response to the small amount of slow neutrons outweighs its response to the fast neutrons overwhelmingly responsible for the neutron dose rate. Based on the obtained results we can conclude that NAM-5 provides correct NECF determination if the fraction of slow neutrons in the neutron dose rate is more than 20%. A satisfactory correlation between the NECF determined by NAM-5 and the multi-moderated BF3 tube method was observed, but the multi-moderated BF 3 tube values were ~30% lower than those obtained by the NAM-5 at the same locations for broader neutron energy spectrum locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polymeric Materials With Additives for Durability and Radiation Shielding in Space

Polymeric materials are attractive for use in space structures because of their light weight and high strength In addition, polymers are made of elements with low atomic numbers (Z), primarily carbon (C), hydrogen (H), oxygen (0), and nitrogen (N) which provide the best shielding from galactic cosmic rays (GCR) (ref. 1). Galactic cosmic rays are composed primarily of nuclei (i.e., fully ionized atoms) plus a contribution of about 2% from electrons and positrons. There is a small but significant component of GCR particles with high charge (Z > 10) and high energy (E >100 GeV) (ref. 2). These so-called HZE particles comprise only 1 to 2% of the cosmic ray fluence but they interact with very high specific ionization and contribute 50% of the long- term dose to humans. The best shield for this radiation would be liquid hydrogen, which is not feasible. For this reason, hydrogen-containing polymers make the most effective practical shields. Moreover, neutrons are formed in the interactions of GCR particles with materials. Neutrons can only lose energy by collisions or reactions with a nucleus since they are uncharged. This is a process that is much less probable than the Coulombic interactions of charged particles. Thus, neutrons migrate far from the site of the reaction in which they were formed. This increases the probability of neutrons reaching humans or electronic equipment. Fast neutrons (> 1 MeV) can interact with silicon chips in electronic equipment resulting in the production of recoil ions which can cause single event upsets (SEU) in sensitive components (ref. 3). Neutrons lose energy most effectively by elastic collisions with light atoms, particularly hydrogen atoms. Therefore, hydrogen-containing polymers are not only effective in interacting with GCR particles; they are also effective in reducing the energy of the neutrons formed in the interactions.

Kiefer, Richard↗

Development of new Polysiloxane Based Liquid Scintillators

In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non-toxic liquid scintillator (EJ309). The results have been related to the optical characterization of these materials, especially as regarding the fluorescence response, and the best performing material (1,1,5,5-Tetraphenyl 1,3,3,5-Tetramethyl Trisiloxane) showed a scintillation light-yield only slightly lower than EJ309, proving to be a promising candidate for the production of an efficient polysiloxane based liquid scintillator. The results as regarding the neutron-gamma pulse shape discrimination capability of the best performing materials are also reported in this work and the scintillation decay time of these materials are compared to the results of fluorescence lifetime analysis. PSD tests have been performed at CN accelerator in Legnaro National Laboratories with a 2.2 MeV pulsed neutron beam using TOF procedure and the pulses have been analyzed in order to evidence the PSD capability of every sample. The reported results pave the way to the development of a new promising class of non-toxic liquid scintillating materials for neutron detection, with good light output and interesting PSD characteristics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ITER Neutronic Challenges for Upper Port 14

The future of magnetically confined nuclear fusion facilities is extremely promising, yet there are extensive challenges that still have to be addressed. These challenges range significantly, but one of the more difficult challenges is nuclear shielding and nuclear safety. The challenge of adequately shielding neutrons is especially prevalent at ITER. Throughout the lifetime of ITER there will be large quantities of high energy (14.1- MeV) neutrons generated, with the expected neutron lifetime fluence to be around 0.3 MW.a/m{sup 2}. For such a large neutron fluence, shielding is a very important factor for the operation of ITER. Not only the shielding of the people that will be supporting the facility, but also to the components that surround the plasma. Without the many diagnostics that are planned for ITER operation, ITER would not be able to function. But with the inclusion of the diagnostics and the many apertures required, an interesting neutronics environment is created. This environment is like nothing we have seen or are currently able to create on the earth. Due to this unknown, significant time and effort is being placed on the research, design, and analysis of the ITER neutronics environment. A neutron has an interesting life after birth within the plasma on ITER. There are many different paths and reactions that can take place; so many, that trying to simplify the problem has brought significant unknowns into the analysis. Due to unique material compositions, neutron streaming paths, and neutronics requirements, the simplest of ITER neutronics calculations have to be thought out in great detail. Placing a new hole for a diagnostic creates a new streaming path; internal components must survive a high fast neutron flux, while external components face a completely different neutron energy spectrum of a high flux; material activation within human accessible areas must be maintained to an allowable level. As the complexity of the ITER device grows, so does the complexity of the neutronics challenges.

61 RADIATION PROTECTION AND DOSIMETRY↗

On observation of neutron quantum states in the Earth's gravitational field

Observation of neutron gravitational quantum states E{sub n}=mgz{sub n} in the peV energy range (z{sub 1} is about 10 {mu}m in the vertical direction) in the experiment conducted at Laue-Langevin Institute, Grenoble, with ultracold neutrons was recently reported in a series of publications. The purpose of the present work is to analyze the experiment. The experimental apparatus is designed to measure a transmission function T(z{sub a}), namely, a horizontal flux of relatively fast neutrons (k>>k{sub z} in wavelength terms) passing through a slit of variable height z{sub a} of upper absorbing wall. The quantum states in question are defined by the so-called Airy functions, which are solutions to the stationary 1D equation for a neutron 'bouncing' above the perfect mirror in a linear potential field. The Airy functions describe the quantum bouncer (QB), the concept of which is subject to theoretical study of toy 1D models of gravitationally bound particles in nonrelativistic quantum mechanics (QM). This is essentially different from the 3D nonstationary QM object, 'the running QB', investigated in the experiment. The authors assume that there is a connection between T(z{sub a}) and the probability density distribution P(z,z{sub a}) for QB states. They devised the 'phenomenological model', in which the quantum pattern should be visible in the transmission curve. We argue, however, that the measured curve T(z{sub a}) is not sensitive to QB states. Instead, it is sensitive to dynamics of neutron horizontal transport inside the absorbing slit for neutrons of energy values about 10{sup 5} times greater than eigenvalues E{sub n}. The latter are related to the neutron transverse mode k{sub z} and cannot be termed ''energies of neutron gravitational quantum states.'' We conclude that the experiment setup and real conditions are not adequate to the claimed objective, and the methodology of measured data treatment is flawed. The authors' claim that 'neutron gravitational quantum states are observed' is neither theoretically nor experimentally substantiated. Final, statistically significant results of the experiment are consistent with our physical reasoning that the experiment is not sensitive to 'neutron gravitational quantum states' (in terms of Airy mode) and does not prove even their existence in rigorous quantum-mechanical terms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗