Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Key Observations and Discoveries from the Vector Electric Field Investigation on the C/NOFS Satellite

Launched in 2008 and operating for 7.5 years, the Air Force Communication /Navigation Outage Forecasting System (C/NOFS) satellite included the Vector Electric Field Investigation (VEFI) designed and built at NASA’s Goddard Space Flight Center. VEFI successfully met its objectives: 1) investigate the role of ambient electric fields in initiating nighttime density depletions and turbulence; 2) determine the quasi-DC electric fields associated with abrupt density depletions, and 3) quantify the spectrum of the irregularities associated with density depletions, providing many key observations and discoveries including: -- Global (low latitude) vector DC electric fields at 16 s/sec revealing variations with local time, longitude, and season between extremely low and moderate solar activity-- Reversed zonal E x B drifts below the F-region ledge at sunset and simultaneous observations of large scale Kelvin-Helmholtz instabilities as seeds of spread-F -- Large expanses of quasi-coherent kilometer-scale vector wave observations (electric field and density) below 450 km and their discovery as a source of scintillations using the C/NOFS GPS -- Reversed zonal DC electric fields and simultaneous observations of afternoon counter electrojet-- Enhanced zonal DC electric fields at sunrise and full vector plasma flow continuity at the terminator-- Vector electric field and density irregularities extending to meter-scales within equatorial plasma depletions -- Intense electric field structure within the equatorial ionosphere at night in the absence of density depletions -- First observations of the westward equatorial electrojet in post-midnight ionosphere and possible association with downward meridional drifts-- Spaceborne Dst observations and implications for ring current asymmetries-- Vector electric and magnetic field Poynting flux within depletions and TIDs-- Measurements of ionospheric reflectance and Alfvenic waves associated with TIDs-- Observations of Alfven resonators -- ULF magnetic field structure within the nightime equatorial ionosphere-- Discovery of Schumman resonances in space and implications of ELF radiowave propagation-- Vector observations of 50-60 Hz powerline radiation without harmonics-- Ion cyclotron resonance absorption lines associated with ELF hiss and the identification of ambient ions-- Parallel electric fields associated with lower hybrid waves driven by thunderstorm lightning-related sferics-- Discovery of Z-mode radiation in the equatorial ionosphere including its associated with density depletions-- Optical lightning detector waveforms and electric field sferics observed up to altitudes of 800 km

Robert F Pfaff↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

An integrated assessment of global and regional water demands for electricity generation to 2095

Electric power plants currently account for approximately one-half of the global industrial water withdrawal. While continued expansion of the electric sector seems likely into the future, the consequent water demands are quite uncertain, and will depend on highly variable water intensities by electricity technologies, at present and in the future. Using GCAM, an integrated assessment model of energy, agriculture, and climate change, we first establish lower-bound, median, and upper-bound estimates for present-day electric sector water withdrawals and consumption by individual electric generation technologies in each of 14 geopolitical regions, and compare them with available estimates of regional industrial or electric sector water use. We then explore the evolution of global and regional electric sector water use over the next century, focusing on uncertainties related to withdrawal and consumption intensities for a variety of electric generation technologies, rates of change of power plant cooling system types, and rates of adoption of a suite of water-saving technologies. Results reveal that the water withdrawal intensity of electricity generation is likely to decrease in the near term with capital stock turnover, as wet towers replace once-through flow cooling systems and advanced electricity generation technologies replace conventional ones. An increase in consumptive use accompanies the decrease in water withdrawal rates; however, a suite of water conservation technologies currently under development could compensate for this increase in consumption. Finally, at a regional scale, water use characteristics vary significantly based on characteristics of the existing capital stock and the selection of electricity generation technologies into the future.

electric power↗

Assessing concurrent effects of climate change on hydropower supply, electricity demand, and greenhouse gas emissions in the Upper Yangtze River Basin of China

Hydropower importantly provides flexible low-carbon electricity, however, climate change will affect the hydropower system through altering hydrologic regimes while also affecting electricity demands for heating and cooling that hydropower resources serve. This study assesses the effect of climate change on hydropower and electricity demand in the Upper Yangtze River Basin (UYRB) in China on the regional net electric load and greenhouse gas (GHG) emissions. This is accomplished by using climate projections from five global climate models (GCMs) to simultaneously force (1) a physically-based hydrological model and a statistically-based hydropower model to estimate the future generating capacity of 21 large hydropower plants in the UYRB and (2) an empirical electricity demand model accounting for socioeconomic and climatic factors. Under climate change, the projected hydropower generation in the UYRB tends to increase in the 21st century but is far less than the increase in electricity demand, increasing the gap between demand and supply. Future increases in overall electricity demand are driven by GDP growth, but climate change will alter the distribution of the seasonal electricity demand. Climate warming decreases electricity demand for heating in winter and increases electricity demand for cooling in summer, but ultimately increases demand. Meanwhile, there is an increasing mismatch between electricity demand and hydropower supply associated with inter- and intra-annual variations, owing to the temporal climate change and increase in compound climate extremes (droughts and heatwaves). Finally, meeting the gap between supply and demand due to climate change is estimated to contribute 79.0–184.6 and 50.6–316.2 MMT CO 2e /yr of additional GHG emissions by the mid and end of 21st century, respectively.

13 HYDRO ENERGY↗

ESTIMATING ELECTRIC FIELDS FROM VECTOR MAGNETOGRAM SEQUENCES

Determining the electric field distribution on the Sun's photosphere is essential for quantitative studies of how energy flows from the Sun's photosphere, through the corona, and into the heliosphere. This electric field also provides valuable input for data-driven models of the solar atmosphere and the Sun-Earth system. We show how observed vector magnetogram time series can be used to estimate the photospheric electric field. Our method uses a 'poloidal-toroidal decomposition' (PTD) of the time derivative of the vector magnetic field. These solutions provide an electric field whose curl obeys all three components of Faraday's Law. The PTD solutions are not unique; the gradient of a scalar potential can be added to the PTD electric field without affecting consistency with Faraday's Law. We then present an iterative technique to determine a potential function consistent with ideal MHD evolution; but this field is also not a unique solution to Faraday's Law. Finally, we explore a variational approach that minimizes an energy functional to determine a unique electric field, a generalization of Longcope's 'Minimum Energy Fit'. The PTD technique, the iterative technique, and the variational technique are used to estimate electric fields from a pair of synthetic vector magnetograms taken from an MHD simulation; and these fields are compared with the simulation's known electric fields. The PTD and iteration techniques compare favorably to results from existing velocity inversion techniques. These three techniques are then applied to a pair of vector magnetograms of solar active region NOAA AR8210, to demonstrate the methods with real data. Careful examination of the results from all three methods indicates that evolution of the magnetic vector by itself does not provide enough information to determine the true electric field in the photosphere. Either more information from other measurements, or physical constraints other than those considered here are necessary to find the true electric field. However, we show it is possible to construct physically reasonable electric field distributions whose curl matches the evolution of all three components of B. We also show that the horizontal and vertical Poynting flux patterns derived from the three techniques are similar to one another for the cases investigated.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrical Transport Experiments at High Pressure

High-pressure electrical measurements have a long history of use in the study of materials under ultra-high pressures. In recent years, electrical transport experiments have played a key role in the study of many interesting high pressure phenomena including pressure-induced superconductivity, insulator-to-metal transitions, and quantum critical behavior. High-pressure electrical transport experiments also play an important function in geophysics and the study of the Earth's interior. Besides electrical conductivity measurements, electrical transport experiments also encompass techniques for the study of the optoelectronic and thermoelectric properties of materials under high pressures. In addition, electrical transport techniques, i.e., the ability to extend electrically conductive wires from outside instrumentation into the high pressure sample chamber have been utilized to perform other types of experiments as well, such as high-pressure magnetic susceptibility and de Haas-van Alphen Fermi surface experiments. Finally, electrical transport techniques have also been utilized for delivering significant amounts of electrical power to high pressure samples, for the purpose of performing high-pressure and -temperature experiments. Thus, not only do high-pressure electrical transport experiments provide much interesting and valuable data on the physical properties of materials extreme compression, but the underlying high-pressure electrical transport techniques can be used in a number of ways to develop additional diagnostic techniques and to advance high pressure capabilities.

58 GEOSCIENCES↗

A Development Path to the Efficient and Cost-Effective Bulk Storage of Electrical Energy

Efficient and cost-effective means for storing electrical energy is becoming an increasing need in our electricity-oriented society. For example, for electric utilities an emerging need is for distributed storage systems, that is, energy storage at substations, at solar or wind-power sites, or for load-leveling at the site of major consumers of their electricity. One of the important consequences of distributed storage for the utilities would be the reduction in transmission losses that would result from having a local source of load-leveling power. For applications such as these there are three criteria that must be satisfied by any new system that is developed to meet such needs. These criteria are: (1) high 'turn-around' efficiency, that is, high efficiency of both storing and recovering the stored energy in electrical form, (2) long service life (tens of years), with low maintenance requirements, and, (3) acceptably low capital cost. An additional requirement for these particular applications is that the system should have low enough standby losses to permit operation on a diurnal cycle, that is, storing the energy during a portion of a given day (say during sunlight hours) followed several hours later by its use during night-time hours. One answer to the spectrum of energy storage needs just outlined is the 'electromechanical battery'. The E-M battery, under development for several years at the Laboratory and elsewhere in the world, has the potential to solve the above energy storage problems in a manner superior to the electro-chemical battery in the important attributes of energy recovery efficiency, cycle lifetime, and amortized capital cost. An electromechanical battery is an energy storage module consisting of a high-speed rotor, fabricated from fiber composite, and having an integrally mounted generator/motor. The rotor operates at high speed, in vacuo, inside of a hermetically sealed enclosure, supported by a 'magnetic bearing', that is, a bearing that uses magnetic forces to support the rotor against gravity. Magnetic bearings are a virtual necessity for the E-M battery in order to achieve long service life, and to minimize frictional losses so that the battery does not lose its charge (run down) too rapidly. These considerations mitigate against the use of conventional mechanical bearings in the E-M battery for most applications. The Laboratory has pioneered the development of a new form of magnetic bearing to meet the special requirements of the E-M battery: the 'ambient-temperature passive magnetic bearing'. Simpler, and potentially much less expensive than the existing 'active' magnetic bearings (ones requiring electronic amplifiers and feedback circuits for their operation) development of the ambient-temperature passive magnetic bearing represents a technological breakthrough. Beyond its use in the E-M battery, the ambient-temperature magnetic bearing could have important applications in replacing conventional lubricated mechanical bearings in electrical machinery. Here the gains would be two-fold: reduced frictional losses, leading to higher motor efficiency, and, of equal importance, the elimination of the need for lubricants and for routine replacement of the bearings owing to mechanical wear. Thus an added benefit from a vigorous pursuit of our electromechanical battery concepts could be its impact on many other areas of industry where rotating machinery in need of improved bearings is involved. If perfected, passive magnetic bearings would seem to represent an almost ideal replacement for the mechanical bearings in many types of industrial electrical machinery. Returning to the issued of energy storage, the E-M battery itself has much to contribute in the area of improving the efficiency of stationary energy storage systems. For example, many electrical utilities utilize 'pumped hydro' energy storage systems as a means of improving the utilization of their 'base-load' power plants. That is, electrical energy is stored during off-peak hours for delivery at times of peak usage. These pumped hydro systems employ upper and lower reservoirs, between which water is shuttled to store and recover the energy. Of necessity, pumped hydro storage facilities are located in mountainous areas, usually far, both from the urban centers where power uses are concentrated, and from the sites of the power plants themselves, increasing the transmission line losses that subtract from the useful energy. More importantly, pumped hydro systems themselves only return from 65 to 70 percent of the electrical energy input required to pump the water from the lower reservoir to the upper one. Thus, including the extra transmission losses from distant siting of the facility, of order 40 percent of the input electrical energy is wasted in every cycle of use of the facility.

25 ENERGY STORAGE↗

More / All Electric Vertical Take-Off and Landing (VTOL) Vehicle Sensitivities to Propulsion and Power Performance

Battery power and energy density are important parameters for the emerging concepts for more / all-electric vehicles. Electric propulsion and power system performance is also important. To better understand how electric propulsion and power systems component performance influences overall vehicle design, a sensitivity assessment was performed noting changes in vehicle gross weight and energy usage. Updated versions of the Revolutionary Vertical lift Technology (RVLT) Project vertical take-off and landing (VTOL) urban air mobility (UAM) reference vehicles and missions were used. NASA electric vehicle studies are discussed which were used to help select the range of electric propulsion and power system performance parameters used in this assessment. Thermal management systems (TMS) considerations are also important; new and innovative power management and distribution systems can reduce electric system weight and losses, reducing thermal management constraints often imposed by electric systems modest maximum use temperatures. Vehicles with higher disk loadings (smaller rotors) require higher power levels per unit weight for VTOL operations, which make them more sensitive to electric system weights and efficiencies. Battery, all-electric vehicles show different sensitivities to component performance than turboelectric or hybrids systems. Battery, all-electric propulsion systems may increase vehicle weight and size, but still results in lower mission energy usage than their hydrocarbon-fueled versions. Significant vehicle weight growth to electric propulsion and power system power-to-weight reductions also occurs at different levels among the various concepts. From these results, one can more readily identify required component performance levels, potential component choices or, research and development paths.

Electric Propulsion Systems (Aircraft)↗

More / All Electric Vertical Take-Off and Landing (VTOL) Vehicle Sensitivities to Propulsion and Power Performance

Battery power and energy density are important parameters for the emerging concepts for more / all-electric vehicles. Electric propulsion and power system performance is also important. To better understand how electric propulsion and power systems component performance influences overall vehicle design, a sensitivity assessment was performed noting changes in vehicle gross weight and energy usage. Updated versions of the Revolutionary Vertical lift Technology (RVLT) Project vertical take-off and landing (VTOL) urban air mobility (UAM) reference vehicles and missions were used. NASA electric vehicle studies are discussed which were used to help select the range of electric propulsion and power system performance parameters used in this assessment. Thermal management systems (TMS) considerations are also important; new and innovative power management and distribution systems can reduce electric system weight and losses, reducing thermal management constraints often imposed by electric systems modest maximum use temperatures. Vehicles with higher disk loadings (smaller rotors) require higher power levels per unit weight for VTOL operations, which make them more sensitive to electric system weights and efficiencies. Battery, all-electric vehicles show different sensitivities to component performance than turboelectric or hybrids systems. Battery, all-electric propulsion systems may increase vehicle weight and size, but still results in lower mission energy usage than their hydrocarbon-fueled versions. Significant vehicle weight growth to electric propulsion and power system power-to-weight reductions also occurs at different levels among the various concepts. From these results, one can more readily identify required component performance levels, potential component choices or, research and development paths.

electric propulsion systems (aircraft) mission ana↗

A complete electrical shock hazard classification system and its application

Current electrical safety standards evolved to address the hazards of 60-Hz power that are faced primarily by electricians, linemen, and others performing facility and utility work. As a result, this leaves a substantial gap in the management of electrical hazards in Research and Development (R&D) and specialized high voltage and high power equipment. We find substantial use of direct current (dc) electrical energy, and the use of capacitors, inductors, batteries, and radiofrequency (RF) power. The electrical hazards of these forms of electricity and their systems are different than for 50/60 Hz power. This paper proposes a method of classifying all of the electrical shock hazards found in all types of R&D and utilization equipment. Examples of the variation of these hazards from NFPA 70E include (a) high voltage can be harmless, if the available current is sufficiently low, (b) low voltage can be harmful if the available current/power is high, (c) high voltage capacitor hazards are unique and include severe reflex action, affects on the heart, and tissue damage, and (d) arc flash hazard analysis for dc and capacitor systems are not provided in existing standards. This work has led to a comprehensive electrical hazard classification system that is based on various research conducted over the past 100 years, on analysis of such systems in R&D, and on decades of experience. Lastly, the new comprehensive electrical shock hazard classification system uses a combination of voltage, shock current available, fault current available, power, energy, and waveform to classify all forms of electrical hazards.

42 ENGINEERING↗

Spatially and Temporally Detailed Water and Carbon Footprints of U.S. Electricity Generation and Use

Electricity generation in the United States entails significant water usage and greenhouse gas emissions. However, accurately estimating these impacts is complex due to the intricate nature of the electric grid and the dynamic electricity mix. Existing methods to estimate the environmental consequences of electricity use often generalize across large regions, neglecting spatial and temporal variations in water usage and emissions. Consequently, electric grid dynamics, such as temporal fluctuations in renewable energy resources, are often overlooked in efforts to mitigate environmental impacts. The U.S. Department of Energy (DOE) has initiated the development of resilient energyshed management systems, requiring detailed information on the local electricity mix and its environmental impacts. This study supports DOE's goal by incorporating geographic and temporal variations in the electricity mix of the local electric grid to better understand the environmental impacts of electricity end users. We offer hourly estimates of the U.S. electricity mix, detailing fuel types, water withdrawal intensity, and water consumption intensity for each grid balancing authority through our publicly accessible tool, the Water Integrated Mapping of Power and Carbon Tracker (Water IMPACT). While our primary focus is on evaluating water intensity factors, our dataset and programming scripts for historical and real-time analysis also include evaluations of carbon dioxide (equivalence) intensity within the same modeling framework. This integrated approach offers a comprehensive understanding of the environmental footprint associated with electricity generation and use, enabling informed decision-making to effectively reduce Scope 2 water usage and emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling of the Electricity and Transportation Sectors - Part I: Sector Overviews

“Sector coupling” is a concept that addresses potential designs for the future power industry. Traditionally, the energy sectors, i.e., electricity supply, transport, and industry, have functioned largely independently from one another. Thus, the concept of sector coupling means that the electricity sector would become the central pillar of the energy system, supplying the other sectors – transportation and industry – with energy in various ways, a scheme described by the term “Power-to-X”. This report delves into the ambitious goal set by the United States to achieve net-zero emissions by 2050, with a pivotal milestone of making half of all passenger vehicles sold in America zero-emission by 2030. Central to achieving this objective is the electrification of the transportation sector, resulting in complex interactions between this sector and the electric industry. As electric vehicles become more prevalent, a shift in the dependency on electricity for vehicle charging emerges, alongside a reduction in the electricity demand associated with maintaining the fossil fuel supply chain. Both the electricity and fossil fuel have been identified as critical infrastructure sectors, the transportation sector's historical reliance on fossil fuels, and the mature supply chain supporting them are explored. This study emphasizes the existing sectoral coupling between the electric energy and transportation sectors, extending beyond vehicle charging to essential operations at refineries, pipeline facilities, storage, and fuel extraction. Recognizing the critical dependency of fossil fuel supply chain operations on the electric sector, this research underscores the need for a comprehensive view of the evolving dynamics between the transportation and electric sectors. This study has been split into two segments, Part-I provides an overview of the existing fossil fuel supply chain architecture and the electrical sector. We provide an in-depth analysis of the grid-transportation sectoral coupling, its interactions, the vulnerabilities and essential take-aways that would help us to address them and apply towards an electrified transportation sector in the future. We engaged with stakeholders to understand their expectations in enabling an electrified transportation. We accumulate the understandings from the current fossil fuel-based system in developing a risk matrix, by identifying all the threats and vulnerabilities and how would they apply to both the current and future transportation systems in Part-II of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temperature limited heater with a conduit substantially electrically isolated from the formation

A system for heating a hydrocarbon containing formation is described. A conduit may be located in an opening in the formation. The conduit includes ferromagnetic material. An electrical conductor is positioned inside the conduit, and is electrically coupled to the conduit at or near an end portion of the conduit so that the electrical conductor and the conduit are electrically coupled in series. Electrical current flows in the electrical conductor in a substantially opposite direction to electrical current flow in the conduit during application of electrical current to the system. The flow of electrons is substantially confined to the inside of the conduit by the electromagnetic field generated from electrical current flow in the electrical conductor so that the outside surface of the conduit is at or near substantially zero potential at 25.degree. C. The conduit may generate heat and heat the formation during application of electrical current.

47 OTHER INSTRUMENTATION↗

System and method of performing a range estimation for hybrid and electric vehicles

A system is provided for performing an automated range estimation process for an electric vehicle using a processor. Included in the system is a range estimator configured to estimate an initial value of an energy required to travel a unit distance for the electric vehicle. The range estimator generates a first estimation model based on a correlation between a maximum all-electric-range and the energy required to travel a unit distance. Then, the first estimation model is adjusted based on one or more predetermined driving conditions. The maximum all-electric-range of the electric vehicle is updated based on the adjusted first estimation model. An estimated range of the electric vehicle is calculated based on the updated maximum all-electric-range of the electric vehicle and a fraction of total energy capability remaining in the electric vehicle. The estimated range of the electric vehicle is outputted and is used to control the electric vehicle.

33 ADVANCED PROPULSION SYSTEMS↗

Enablers towards establishing and growing South Africa’s waste to electricity industry

Highlights: • Electricity supply in South Africa is highly dominated by coal. • A model is initially identified to enable South Africa’s waste to electricity industry. • The model is based on local conditions/challenges but informed by international experience. • The local model is tested based on expert experience of the local waste industry. • Abundance of coal and low cost of land filling identified as primary local barriers. • Enablers required to overcome barriers are proposed as part of revised local model. - Abstract: In South Africa the electricity generation mix is relatively un-diverse whereas globally the transformation of the sector is advancing rapidly. Coal remains the predominant fuel source and limited success has to date been achieved in the renewable energy sector. The electricity generation sector is therefore hindered from moving towards an electricity generation landscape where alternative fuel sources is utilised. This research is aimed at gaining insight into the enablers that led towards an increasing trend (observed globally) in exploiting waste as a fuel for electricity generation, and to outline the presence of obstacles that hinder separation of waste for electricity use in the South African context. Furthermore it is an attempt at informing what appropriate interventions (operational and policy) may be considered suitable for South Africa to overcome these barriers in order to enable a sustainable South African waste to electricity (WTE) Industry. Findings show that numerous barriers to a WTE exists in the South African context, however overcoming these barriers is not as simple as adopting the European model with the aim to modify the electricity generation mix and waste management landscape. Selected enablers deemed appropriate in the South African context are adapted from the European model, and are greatly influenced by the prevailing socio-economic status of South Africa. Primary enablers identified were, (i) government support is needed especially in the form of subsidisation for green energy, (ii) increase landfill costs through the implementation of a landfill tax, (iii) streamline the process for Independent Private Power Producers (IPPPs) to connect to the national grid with off-take guaranteed and the inclusion of WTE into an electricity roadmap (effectively government’s strategy). The proposed enabling interventions would help in overcoming the barriers for a South African WTE industry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing Reaction Temperature, Steam Requirements, and Coke Formation During Methane Steam Reforming Using Electric Fields: A Microkinetic Modeling and Experimental Study

In this study, we approach several common problems with the Ni-catalyzed methane steam reformation reaction (MSR) using a two-pronged approach combining density functional theory (DFT) calculations with experimental work. Specifically, we look at the deactivation of a Ni catalyst due to coke formation, its high operating temperature requirements, and the high steam-to-methane (H 2 O/CH 4 ) ratio needed for proper MSR operation. A DFT-based microkinetic model was developed in the presence and absence of electric fields and the results were compared with experimental results. The microkinetic model shows that under various electric fields, the most favorable MSR mechanism changed slightly. It also shows that the presence of a positive electric field decreases the surface coverage of carbon, increases the water coverage, accelerates the rate-limiting step of the C-H bond cleavage in methane, and increases the desorption rates of the syngas product (CO + H 2 ) during MSR. Consequently, for a given methane conversion, a positive electric field allows for significantly lower H 2 O/CH 4 ratio and operating temperatures as compared to systems without an electric field. These findings correspond well with experimental tests under a variety of operating conditions. In addition, improvement in the catalytic activity due to the presence of a positive electric field remained significant even at industrially relevant applied pressures improving the hydrogen yield greatly. Overall, we find that an applied electric field can play a significant role in improving the catalytic activity of heterogeneous reactions. Here, this information can guide the design of heterogeneous reactions in the presence of an electric field. By utilizing the electric field generated by various renewable energy sources, electric field assisted heterogeneous reactions can open up a paradigm in future energy research.

03 NATURAL GAS↗

Effect of high voltage electric field on structure and property of PEDOT:PSS film

Low electrical conductivity of PEDOT:PSS film is to some extent a limit for its wide application. To solve this problem, the high voltage electric field was used to improve the film’s electrical conductivity and its effects on the film’s structure and properties were investigated. The PEDOT:PSS film was prepared on quartz substrate with spin coating. Visible light transmittance of the prepared film was tested with UV–Visible spectroscopy and chemical structure was measured with Fourier transform Raman spectroscopy (FIRM). The surface morphology was characterized with AFM, and electrical conductivity was measured with Hall effects measurement. The results showed that with the increase of the electric field, the electrical conductivity of PEDOT:PSS film was boosted rapidly at first, and then improved slowly when the electric field was above 200 kV/m. The film’s electrical conductivity improved more than 17 times in total from 0.51 × 10{sup –3} up to 8.92 × 10{sup –3} S/m. However, the film’s visible light transmittance decreased only a little with the increase of the electric field, not more than 3%. In addition, despite little change in the chemical structure of the PEDOT:PSS film, its surface roughness increased significantly with the increase of the electric field intensity.

36 MATERIALS SCIENCE↗