Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A diamond 14 MeV neutron energy spectrometer with high energy resolution

A self-standing single-crystal chemical vapor deposited diamond was obtained using lift-off method. It was fabricated into a radiation detector and response function measurements for 14 MeV neutrons were taken at the fusion neutronics source. 1.5% of high energy resolution was obtained by using the {sup 12}C(n, α){sup 9}Be reaction at an angle of 100° with the deuteron beam line. The intrinsic energy resolution, excluding energy spreading caused by neutron scattering, slowing in the target and circuit noises was 0.79%, which was also the best resolution of the diamond detector ever reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector calibration of the Indian cosmic ray experiment (IONS) in Space-Shuttle Spacelab-13

In the Indian cosmic ray experiment (IONS) in Spacelab-3 the intention is to study nuclei up to iron in low energy cosmic rays, using CR-39 (DOP) detectors. CR-39 (DOP) was exposed to He4, C12, O16, Ne20, Si28, Ar40, Cr52 and Fe56 accelerated beams from various accelerator facilities available around the world. Different beam energies and exposure angles were used. From these exposures, the charge resolution and energy resolution for the detector in the region of interest were studied. The effect of pre-annealing and depth on the response of our detector was studied. For isotopic resolution, exposed the detector samples were exposed to Ne2O and Ne22 accelerated beams. Samples of CR-39 (DOP) exposed to different accelerated heavy ions were kept in the detector module to take into account the effect of ambient conditions on detector response during the flight.

Yadav, J. S.↗

Detection of neutrinos, antineutrinos, and neutrino-like particles

An apparatus for detecting the presence of a nuclear reactor by the detection of antineutrinos from the reactor can include a radioactive sample having a measurable nuclear activity level and a decay rate capable of changing in response to the presence of antineutrinos, and a detector associated with the radioactive sample. The detector is responsive to at least one of a particle or radiation formed by decay of the radioactive sample. A processor associated with the detector can correlate rate of decay of the radioactive sample to a flux of the antineutrinos to detect the reactor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved measurements of the hot-electron population in ignition-scale experiments on the National Ignition Facility (invited)

In laser-driven inertial confinement fusion, hot electrons can preheat the fuel and prevent fusion-pellet compression to ignition conditions. Measuring the hot-electron population is key to designing an optimized ignition platform. The hot electrons in these high-intensity, laser-driven experiments, created via laser-plasma interactions, can be inferred from the bremsstrahlung generated by hot electrons interacting with the target. At the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 43, 2841 (2004)], the filter-fluorescer x-ray (FFLEX) diagnostic–a multichannel, hard x-ray spectrometer operating in the 20–500 keV range–has been upgraded to provide fully time-resolved, absolute measurements of the bremsstrahlung spectrum with ∼300 ps resolution. Initial time-resolved data exhibited significant background and low signal-to-noise ratio, leading to a redesign of the FFLEX housing and enhanced shielding around the detector. The FFLEX x-ray sensitivity was characterized with an absolutely calibrated, energy-dispersive high-purity germanium detector using the high-energy x-ray source at NSTec Livermore Operations over a range of K-shell fluorescence energies up to 111 keV (U K{sub β}). The detectors impulse response function was measured in situ on NIF short-pulse (∼90 ps) experiments, and in off-line tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors

Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for the light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron characterization of high-Z, current-mode x-ray detectors

Fast x-ray detectors are critical tools in pulsed power and fusion applications, where detector impulse response of a nanosecond or better is often required. Semiconductor detectors can create fast, sensitive devices with extensive operational flexibility. There is typically a trade-off between detector sensitivity and speed, but higher atomic number absorbers can increase hard x-ray absorption without increasing the charge collection time, provided carriers achieve high velocity. This paper presents x-ray pulse characterization conducted at the Advanced Photon Source of x-ray absorption efficiency and temporal impulse response of current-mode semiconductor x-ray detectors composed of Si, GaAs, and CdTe.

47 OTHER INSTRUMENTATION↗

Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range 2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge distribution and response time for a modulation-doped extrinsic infrared detector

The electric charge distribution and response time of a modulation-doped extrinsic infrared detector are determined. First, it is demonstrated theoretically that the photoconductive layer is effectively depleted of ionized majority-impurity charges so that scattering is small and mobility is high for photogenerated carriers. Then, using parameters appropriate to an actual detector, the predicted response time is 10 to the -8th to about 10 to the -9th s, which is much faster than comparable conventional detectors. Thus, the modulation-doped detector design would be valuable for heterodyne applications.

Hadek, Victor↗

A measurement of the calorimeter response to single hadrons and determination of the jet energy scale uncertainty using LHC Run-1 pp-collision data with the ATLAS detector

A measurement of the calorimeter response to isolated charged hadrons in the ATLAS detector at the LHC is presented. This measurement is performed with 3.2 nb –1 of proton–proton collision data at √s = 7 TeV from 2010 and 0.1 nb –1 of data at √s = 8 TeV from 2012. A number of aspects of the calorimeter response to isolated hadrons are explored. After accounting for energy deposited by neutral particles, there is a 5% discrepancy in the modelling, using various sets of Geant4 hadronic physics models, of the calorimeter response to isolated charged hadrons in the central calorimeter region. The description of the response to anti-protons at low momenta is found to be improved with respect to previous analyses. The electromagnetic and hadronic calorimeters are also examined separately, and the detector simulation is found to describe the response in the hadronic calorimeter well. The jet energy scale uncertainty and correlations in scale between jets of different momenta and pseudorapidity are derived based on these studies. The uncertainty is 2–5% for jets with transverse momenta above 2 TeV, where this method provides the jet energy scale uncertainty for ATLAS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Baseline Response of Silicon Strip Detectors and Comparison of Cost-Effective Amplifiers

Silicon strip detectors are a proven and more affordable technology. However, they are susceptible to high radiation damage. As part of the characterization of the effects of high radiation on silicon detectors, a baseline performance of these detectors under normal, low radiation conditions needs to be established. We did this by using an optimized setup and an infrared laser to simulate particle incidents. The detectors responded to applied bias voltage as expected. We then compared the performance of both economy amplifiers and an expensive amplifier as part of the optimized setup. For all intents and purposes, the economy amplifier worked just as well as the expensive amplifier.

43 PARTICLE ACCELERATORS↗

(55)Fe X-ray Response of HgCdTe NIR Detector Arrays

Conversion gain is a fundamental parameter in detector characteristics that is used to measure many identifying detector properties, including read noise, dark current, and quantum efficiency (QE). Charge coupling effects, such as inter-pixel capacitance, attenuate photon shot noise and result in an overestimation of of conversion gain when implementing the photon transfer technique. The (55)Fe X-ray technique is a direct and simple method by which to measure the conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by a single X-ray photon. Here we present the calibrated pair production energy for 1.7 micron HgCdTe infrared detectors.

Fox, Ori↗

The 55Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

A technique involving Fe-55 X-rays provides a straightforward method to measure the response of a detector. The detector's response can lead directly to a calculation of the conversion gain (e(-) ADU(-1) ), as well as aid detector design and performance studies. We calibrate the Fe-15 X-ray energy response and pair production energy of HgCdTe using 8 HST WFC3 1.7 micron flight grade detectors. The results show that each Ka X-ray generates 2273 +/- 137 electrons, which corresponds to a pair-production energy of 2.61 +/- 0.16 eV. The uncertainties are dominated by our knowledge of the conversion gain. In future studies, we plan to eliminate this uncertainty by directly measuring conversion gain at very low light levels.

Fox, Ori↗