At least 829 records · Page 46

Systematic Source Determination and X-Ray Radiography Detection of Nonuniformities on High-Density Carbon Ablators

Recent deuterium-tritium (D-T)–layered implosion experiments at the National Ignition Facility have achieved a burning plasma and >1-MJ neutron yield. A series of repeat experiments have shown that the degree of performance is very likely dependent on capsule quality, including the quantity of what are collectively termed “high- Z particles.” These particles are detected on a custom-built radiography system, known as the Sagometer, during the final target qualification process. The term particles is misleading, as the source of these nonuniformities in the capsule images is uncertain; the term detection will be used instead. An increased number of D-T targets have been rejected at the final stages of production due to Sagometer detections. Late detections are deleterious in terms of loss of production parts, effort, and overall operating efficiency. In response, we undertook an effort to determine the origin of these detections and to ultimately mitigate target losses caused by them. Through careful testing and analysis, we have determined neither insufficient production cleanliness nor hohlraum shedding is responsible for the detections on the capsule. Here, we determined that the detections are inherent to the capsule and have made efforts to use the Zeiss Xradia to identify them earlier in the production process. While testing revealed the Xradia is not currently sufficient for identifying such particles using radiography images, we continue to look to other forms of metrology to down select the capsules early in the process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

K2: A NEW METHOD FOR THE DETECTION OF GALAXY CLUSTERS BASED ON CANADA-FRANCE-HAWAII TELESCOPE LEGACY SURVEY MULTICOLOR IMAGES

We have developed a new method, K2, optimized for the detection of galaxy clusters in multicolor images. Based on the Red Sequence approach, K2 detects clusters using simultaneous enhancements in both colors and position. The detection significance is robustly determined through extensive Monte Carlo simulations and through comparison with available cluster catalogs based on two different optical methods, and also on X-ray data. K2 also provides quantitative estimates of the candidate clusters' richness and photometric redshifts. Initially, K2 was applied to the two color (gri) 161 deg{sup 2} images of the Canada-France-Hawaii Telescope Legacy Survey Wide (CFHTLS-W) data. Our simulations show that the false detection rate for these data, at our selected threshold, is only approx1%, and that the cluster catalogs are approx80% complete up to a redshift of z = 0.6 for Fornax-like and richer clusters and to z approx 0.3 for poorer clusters. Based on the g-, r-, and i-band photometric catalogs of the Terapix T05 release, 35 clusters/deg{sup 2} are detected, with 1-2 Fornax-like or richer clusters every 2 deg{sup 2}. Catalogs containing data for 6144 galaxy clusters have been prepared, of which 239 are rich clusters. These clusters, especially the latter, are being searched for gravitational lenses-one of our chief motivations for cluster detection in CFHTLS. The K2 method can be easily extended to use additional color information and thus improve overall cluster detection to higher redshifts. The complete set of K2 cluster catalogs, along with the supplementary catalogs for the member galaxies, are available on request from the authors.

79 ASTRONOMY AND ASTROPHYSICS↗

DETECTION, LOCALIZATION, AND CHARACTERIZATION OF GRAVITATIONAL WAVE BURSTS IN A PULSAR TIMING ARRAY

Efforts to detect gravitational waves by timing an array of pulsars have traditionally focused on stationary gravitational waves, e.g., stochastic or periodic signals. Gravitational wave bursts-signals whose duration is much shorter than the observation period-will also arise in the pulsar timing array waveband. Sources that give rise to detectable bursts include the formation or coalescence of supermassive black holes (SMBHs), the periapsis passage of compact objects in highly elliptic or unbound orbits about an SMBH, or cusps on cosmic strings. Here, we describe how pulsar timing array data may be analyzed to detect and characterize these bursts. Our analysis addresses, in a mutually consistent manner, a hierarchy of three questions. (1) What are the odds that a data set includes the signal from a gravitational wave burst? (2) Assuming the presence of a burst, what is the direction to its source? (3) Assuming the burst propagation direction, what is the burst waveform's time dependence in each of its polarization states? Applying our analysis to synthetic data sets, we find that we can detect gravitational waves even when the radiation is too weak to either localize the source or infer the waveform, and detect and localize sources even when the radiation amplitude is too weak to permit the waveform to be determined. While the context of our discussion is gravitational wave detection via pulsar timing arrays, the analysis itself is directly applicable to gravitational wave detection using either ground- or space-based detector data.

79 ASTRONOMY AND ASTROPHYSICS↗

DETECTING COLD GAS AT z = 3 WITH THE ATACAMA LARGE MILLIMETER/SUBMILLIMETER ARRAY AND THE SQUARE KILOMETER ARRAY

We forecast the abilities of the Atacama Large Millimeter/submillimeter Array (ALMA) and the Square Kilometer Array (SKA) to detect CO and H I emission lines in galaxies at redshift z = 3. A particular focus is set on Milky Way (MW) progenitors at z = 3 since their detection within 24 hr constitutes a key science goal of ALMA. The analysis relies on a semi-analytic model, which permits the construction of an MW progenitor sample by backtracking the cosmic history of all simulated present-day galaxies similar to the real MW. Results are as follows: (1) ALMA can best observe an MW at z = 3 by looking at CO(3-2) emission. The probability of detecting a random model MW at 3{sigma} in 24 hr using 75 km s{sup -1} channels is roughly 50%, and these odds can be increased by co-adding the CO(3-2) and CO(4-3) lines. These lines fall into ALMA band 3, which therefore represents the optimal choice toward MW detections at z = 3. (2) Higher CO transitions contained in the ALMA bands {>=}6 will be invisible, unless the considered MW progenitor coincidentally hosts a major starburst or an active black hole. (3) The high-frequency array of SKA, fitted with 28.8 GHz receivers, would be a powerful instrument for observing CO(1-0) at z = 3, able to detect nearly all simulated MWs in 24 hr. (4) H I detections in MWs at z = 3 using the low-frequency array of SKA will be impossible in any reasonable observing time. (5) SKA will nonetheless be a supreme H I survey instrument through its enormous instantaneous field of view (FoV). A one-year pointed H I survey with an assumed FoV of 410 deg{sup 2} would reveal at least 10{sup 5} galaxies at z = 2.95-3.05. (6) If the positions and redshifts of those galaxies are known from an optical/infrared spectroscopic survey, stacking allows the detection of H I at z = 3 in less than 24 hr.

79 ASTRONOMY AND ASTROPHYSICS↗

CORC $^{\circledR}$ cable terminations with integrated Hall arrays for quench detection

ReBCO superconducting cables have the potential to enable compact thermonuclear fusion reactors that operate at magnetic fields exceeding 20 T and allow operation at temperatures far exceeding the boiling point of liquid helium, potentially allowing for demountable magnets. Normal zone detection remains a challenge, and while novel quench detection techniques are an active area of research, few are non-invasive, provide real-time quench detection, and have been demonstrated with current ramp rates relevant for fusion reactors. To address this problem, a CORC$^{\circledR}$ cable termination is developed with integrated Hall sensors to monitor current redistribution as a proxy for quench detection. The methodology exploits the current sharing and layered topology in CORC$^{\circledR}$ cables, and allows quench detection using a localized sensor instead of co-wound voltage wires or optical fibers. Furthermore, experiments are presented where current redistribution is measured from induced quenches, and in a 0.2 meter CORC$^{\circledR}$ sample it is found that the Hall sensors detect normal zone transitions with a similar magnitude and temporal resolution as voltage measurements. To emulate the conditions of dynamic poloidal and central solenoidal fields, experiments are repeated with ramp rates up to 10 kA s -1 that demonstrate the potential to detect normal zone development over a range of experimental parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quench detection using Hall sensors in high-temperature superconducting CORC ® -based cable-in-conduit-conductors for fusion applications

Advanced magnet systems for fusion applications would greatly benefit from the use of high-temperature superconductors (HTS). These materials allow fusion magnets to operate at higher magnetic fields, allowing for more compact fusion machines, and allow for operation at elevated temperatures, enabling demountable coils that provide access for maintenance of the fusion reactor. Quench detection remains a major challenge in the protection of HTS magnets that are vulnerable to localized conductor burnout due to their low quench propagation velocities. One of the methods explored is the use of Hall sensors that are incorporated in or near the magnet terminations that can detect local field variations that occur as a result of current redistribution within the conductor to bypass a hotspot within the magnet winding. This method is potentially well suited for Cable in Conduit Conductors, such as those made from Conductor on Round Core (CORC) cables, in which sub-cables containing HTS tapes are connected to the terminations at a low resistance. Here, to demonstrate the technique, a CORC ® triplet consisting of three sub-cables, rated for 4 kA operation at 77 K, was manufactured and Hall sensors were used to measure local field variations next to the terminations due to current redistribution between the cables. The Hall response was compared to voltages that developed over the cables and terminations as a local hotspot was applied to different cables in the triplet. It was found that the Hall sensors were faster and more sensitive than voltage contact measurements and were able to reliably detect current redistribution of only a few amperes caused by a hotspot, well before the triplet exceeded its critical current. The method also allowed the detection of heater-induced hotspots during high ramp rates of 2 kA s<:sup>–1 relevant for fusion applications. Hall sensors have a distinct benefit of being less sensitive to inductive pickup of AC interference compared to voltage contact measurements that make quench detection through voltage measurements in magnets especially challenging. The method can also be used for diagnostic measurements of current redistribution caused by other sources such as inhomogeneous current injection from faulty joints, or localized conductor damage. The Hall sensors are likely capable of detecting the onset of a quench that may occur a far distance away from the sensor location, presenting a breakthrough in HTS quench detection that potentially removes one of the remaining barriers to reliable operation of large HTS magnet systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Confident detection of doubly ionized thorium in the extreme Ap star CPD-62° 2717

Despite the Universe containing primordial thorium (Th) of sufficient abundance to appear in stellar spectra, detection of Th has to date been tentative and based on just a few weak and blended lines. Here, we present convincing evidence not only for the first Th detection in a magnetic chemically peculiar Ap star but also for the first detection of Th iii in a stellar spectrum. CPD-62° 2717 was initially recognized as a highly magnetized Ap star due to resolved magnetically split lines captured in H-band spectra from the SDSS/APOGEE survey. The star was subsequently pinpointed as extraordinarily peculiar when careful inspection of the H-band line content revealed the presence of five lines of Th iii, none of which are detected in the other ∼1500 APOGEE-observed Ap stars. Follow-up with the VLT + UVES confirmed a similarly peculiar optical spectrum featuring dozens of Th iii lines, among other peculiarities. Unlike past claims of Th detection, and owing to high-resolution observations of the strong (∼8–12 kG) magnetic field of CPD-62° 2717, the detection of Th iii can in this case be supported by matches between the observed and theoretical magnetic splitting patterns. Comparison of CPD-62° 2717 to stars for which Th overabundances have been previously reported (e.g. Przybylski’s Star) indicates that only for CPD-62° 2717 is the Th detection certain. Along with the focus on Th iii, we use time series measurements of the magnetic field modulus to constrain the rotation period of CPD-62° 2717 to ∼4.8 yr, thus establishing it as a new example of a superslowly rotating Ap star.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative evaluation of an air-monitoring network using atmospheric transport modeling and frequency of detection methods

A methodology to quantify the performance of an air monitoring network in terms of frequency of detection has been developed. The methodology utilizes an atmospheric transport model to predict air concentrations of radionuclides at the samplers for a given release time and duration. Frequency of detection is defined as the fraction of “events” that result in a detection at either a single sampler or network of samplers. An “event” is defined as a release of finite duration that begins on a given day and hour of the year from a facility with the potential to emit airborne radionuclides. Another metric of interest is the network intensity, which is defined as the fraction of samplers in the network that have a positive detection for a given event. The frequency of detection methodology allows for evaluation of short-term releases that include effects of short-term variability in meteorological conditions. The methodology was tested using the U.S. Department of Energy Idaho National Laboratory (INL) Site ambient air monitoring network consisting of 37 low-volume air samplers in 31 different locations covering a 17,630 km 2 region. Releases from six major INL facilities distributed over an area of 1,435 km 2 were modeled and included three stack sources and eight ground-level sources. A Lagrangian Puff air dispersion model (CALPUFF) was used to model atmospheric transport. The model was validated using historical 125 Sb releases and measurements. Relevant one-week release quantities from each emission source were calculated based on a dose of 1.9 × 10 –4 mSv at a public receptor (0.01 mSv assuming release persists over a year). Important radionuclides considered include 241 Am, 137 Cs, 238 Pu, 239 Pu, 90 Sr, and tritium. Results show the detection frequency is over 97.5% for the entire network considering all sources and radionuclides. Network intensities ranged from 3.75% to 62.7%. Evaluation of individual samplers indicated some samplers were poorly situated and add little to the overall effectiveness of the network. As a result, using the frequency of detection methods, optimum sampler placements were simulated that could substantially improve the performance and efficiency of the network.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bayesian approach to the detection problem in gravitational wave astronomy

The analysis of data from gravitational wave detectors can be divided into three phases: search, characterization, and evaluation. The evaluation of the detection--determining whether a candidate event is astrophysical in origin or some artifact created by instrument noise--is a crucial step in the analysis. The ongoing analyses of data from ground-based detectors employ a frequentist approach to the detection problem. A detection statistic is chosen, for which background levels and detection efficiencies are estimated from Monte Carlo studies. This approach frames the detection problem in terms of an infinite collection of trials, with the actual measurement corresponding to some realization of this hypothetical set. Here we explore an alternative, Bayesian approach to the detection problem, that considers prior information and the actual data in hand. Our particular focus is on the computational techniques used to implement the Bayesian analysis. We find that the parallel tempered Markov chain Monte Carlo (PTMCMC) algorithm is able to address all three phases of the analysis in a coherent framework. The signals are found by locating the posterior modes, the model parameters are characterized by mapping out the joint posterior distribution, and finally, the model evidence is computed by thermodynamic integration. As a demonstration, we consider the detection problem of selecting between models describing the data as instrument noise, or instrument noise plus the signal from a single compact galactic binary. The evidence ratios, or Bayes factors, computed by the PTMCMC algorithm are found to be in close agreement with those computed using a reversible jump Markov chain Monte Carlo algorithm.

79 ASTRONOMY AND ASTROPHYSICS↗

Adaptive Anomaly Detection for Dynamic Clinical Event Sequences

Over the past decade, health information technology (IT) has enabled the amount of digital information stored in electronic health records (EHRs) to expand greatly. However, according to some studies, hazards in health IT can lead to changes in clinical decisions, care processes, and care outcomes, as well as other issues. Thus, the effects of health IT hazards on patient safety have been at the forefront of recent patient safety research. Nonetheless, hazard detection in health IT remains a challenge. In this paper, the authors assume that safety-related issues in health IT would exhibit anomalous characteristics in EHR data. Although all hazards will exhibit some anomalous characteristics, not all anomalies can be regarded as hazards. The authors hypothesize that errors in health IT could lead to interruptions in the sequence of clinical actions. To this end, the problem of detecting anomalous sequences in big EHR data is considered. This paper focuses on dynamic event sequences, which are a series of clinical actions in motion. The authors propose an adaptive anomaly detection approach that uses higher-order network representation to detect anomalous sequences. Furthermore, the authors propose a contiguous subsequence anomaly detection approach that identifies abnormal subsequences in the detected anomalous sequences. The proposed approaches are tested by using synthetic and real-world EHR data. The proposed methods outperform existing state of the art anomaly detection techniques. To reduce the computational complexity associated with the operational implementation of the proposed approaches, the Apache Spark environment was leveraged, and a much shorter run time together with improved performance were achieved, especially for data with more than 60,000 sequences.

Niu, Haoran↗

Signal Processing Based Method for Real-Time Anomaly Detection in High-Performance Computing

Performance anomalies can manifest as irregular execution times or abnormal execution events for many reasons, including network congestion and resource contention. Detecting such anomalies in real-time by analyzing the details of performance traces at scale is impractical due to the sheer volume of data High-Performance Computing (HPC) applications produce. In this paper, we propose formulating HPC performance anomaly detection as a signal-processing problem where anomalies can be treated as noise. We evaluate our proposed method in comparison with two other commonly used anomaly detection techniques of varying complexity based on their detection accuracy and scalability. Since real-time in-situ anomaly detection at a large scale requires lightweight methods that can handle a large volume of streaming data, we find that our proposed method provides the best trade-off. We then implement the proposed method in Chimbuko, the first online, distributed, and scalable workflow-level performance trace analysis framework. We compare our proposed signal-based anomaly detection algorithm with two other methods using a function of their accuracy, F1 score, and detection overhead. Our experiments demonstrate that our proposed approach achieves a 99% improvement for the benchmark datasets and a 93% improvement with Chimbuko traces.

99 GENERAL AND MISCELLANEOUS↗

Vehicle Tracking with Crop-based Detection

End-to-end production of vehicle tracking data from video in real-time and with high accuracy remains a challenging problem due to the computational cost of object detection on each frame. In this work we present Tracking with Crop-based Detection, a method for speeding object tracking in constrained contexts (with stable cameras and relatively-predictable object motion) such as vehicle traffic monitoring. We leverage this context to provide a strong prior for object locations, which we use to 1.) boost detection speed by detecting objects only in regions corresponding to object priors on most frames and 2.) inform the selection of the detector output for each object. We evaluate Crop-based Detection as an extension to the KIOU object tracker (Crop-KIOU) on the UA-DETRAC dataset. The proposed tracker outperforms all other reported algorithms in terms of PR-MOTA, PR-MOTP, and mostly tracked objects on the UA-DETRAC benchmark, establishing a new state-of-the-art. Relative to tracking by detection with KIOU, Crop-KIOU achieves a 26% higher frame-rate and increases accuracy. Furthermore, Tracking with Crop-based Detection can be combined with frame skipping; we show a 149% increase in framerate relative to KIOU with no decrease in accuracy using this combination of methods.

Gloudemans, Derek↗

Detection and Localization of Damaged Photovoltaic Cells and Modules Using Spread Spectrum Time Domain Reflectometry

The operating efficiency of photovoltaic (PV) plants can be improved if damaged or degraded modules can be detected and identified. Currently, string-level power electronics can detect problems with modules or cabling but not locate them, which would facilitate addressing these issues. Here, we investigate the ability of spread spectrum time domain reflectometry (SSTDR) to both detect and locate/identify damaged cells and modules within a series-connected PV string. We tested the ability of SSTDR to detect and locate single-cell mini-modules and full-sized PV modules, which were intentionally damaged by impacts with a hammer (breaking the glass and damaging the silicon below) or by cutting through some or all busbars. Damage to the glass and silicon of cells was detected and located within a small string of minimodules. Busbar damage was detectable only if an open was created by cutting through all intercell busbars. Furthermore, physical impact damage to the glass and silicon of a full-sized PV module could be detected, but further development of signal processing is needed to achieve localization of such damaged modules within a string.

14 SOLAR ENERGY↗

Cycle-by-cycle Delay Estimation at Signalized Intersections by using Machine Learning and Simulated Video Detection Data

Accurate estimation of delay is crucial for efficient traffic signal operations. Estimation of delay in the real-time manner using traditional loop detectors requires advanced detectors (in addition to stop-bar detection). In cases when this detection layout is not in place, delay estimates are approximated with a lower accuracy. Video detection is one of the most frequently deployed detection systems at signalized intersections in recent years. In most cases video detection operates in the same way as traditional inductive loops. However, when coupled with computer vision algorithms, video detection systems could be used to retrieve additional information (e.g., vehicular arrivals and departures) that cannot be taken out from the conventional systems (e.g., long stop-bar loop detectors). Although present for several decades, video detection data were not frequently examined for delay estimation purposes. In this study, we proposed a novel delay estimation model which can be developed with only data from stop-bar video detectors. Relevant data were collected from a simulation model of 11 signalized intersections at downtown Chattanooga, TN and processed to create needed inputs for model development. With the use of multigene genetic programming the authors developed a delay model that outperforms accuracy of multi regression model. Furthermore, authors evaluated the developed model by comparison with the other benchmark delay models, such as HCM and approach delay model. It was found that the developed MGGP delay model outperforms benchmark models for a wide range of traffic and signal operation conditions.

Erdagi, Ismet Goksad↗

Real-time Event Detection Using Rank Signatures of Real-world PMU Data

Timely detection of power system events is a crucial task, which can facilitate the implementation of remedial actions to improve reliability, resiliency, and security of the system. Meanwhile, the widespread deployment of phasor measurement units (PMUs) makes it possible to develop data-driven event detection techniques. However, relying purely on data without incorporating domain knowledge for the event detection task in power systems poses substantial security and stability risks due to issues associated with data misinterpretation and model accuracy. In this regard, we propose a real-time event detection method using real-world PMU data by incorporating domain knowledge to adequately capture the event signatures. Specifically, we track the change in rank signatures of PMU data to accurately localize the events. To optimize the detection process, we incorporate an offline Bayesian optimization algorithm to tune the parameters by efficiently searching for the best values. The experiments using the real-world PMU dataset from a U.S. interconnection show that the proposed event detection approach can efficiently detect the events from PMU data streams with high accuracy.

Ghasemkhani, Amir↗

Investigation of lung nodule detectability in low-dose 320-slice computed tomography

Low-dose imaging protocols in chest CT are important in the screening and surveillance of suspicious and indeterminate lung nodules. Techniques that maintain nodule detectability yet permit dose reduction, particularly for large body habitus, were investigated. The objective of this study was to determine the extent to which radiation dose can be minimized while maintaining diagnostic performance through knowledgeable selection of reconstruction techniques. A 320-slice volumetric CT scanner (Aquilion ONE, Toshiba Medical Systems) was used to scan an anthropomorphic phantom at doses ranging from {approx}0.1 mGy up to that typical of low-dose CT (LDCT, {approx}5 mGy) and diagnostic CT ({approx}10 mGy). Radiation dose was measured via Farmer chamber and MOSFET dosimetry. The phantom presented simulated nodules of varying size and contrast within a heterogeneous background, and chest thickness was varied through addition of tissue-equivalent bolus about the chest. Detectability of a small solid lung nodule (3.2 mm diameter, -37 HU, typically the smallest nodule of clinical significance in screening and surveillance) was evaluated as a function of dose, patient size, reconstruction filter, and slice thickness by means of nine-alternative forced-choice (9AFC) observer tests to quantify nodule detectability. For a given reconstruction filter, nodule detectability decreased sharply below a threshold dose level due to increased image noise, especially for large body size. However, nodule detectability could be maintained at lower doses through knowledgeable selection of (smoother) reconstruction filters. For large body habitus, optimal filter selection reduced the dose required for nodule detection by up to a factor of {approx}3 (from {approx}3.3 mGy for sharp filters to {approx}1.0 mGy for the optimal filter). The results indicate that radiation dose can be reduced below the current low-dose (5 mGy) and ultralow-dose (1 mGy) levels with knowledgeable selection of reconstruction parameters. Image noise, not spatial resolution, was found to be the limiting factor in detection of small lung nodules. Therefore, the use of smoother reconstruction filters may permit lower-dose protocols without trade-off in diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose and detectability for a cone-beam C-arm CT system revisited

Purpose: The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to (dose){sup 1/2}. A more detailed analysis based on recent theoretical modeling of C-arm CT images is presented in this work. Methods: The signal and noise propagations in a C-arm based CT system have been formulated by other authors using cascaded systems analysis. They established a relationship between detectability and the noise equivalent quanta. Based on this model, the authors obtained a relation between x-ray dose and the diameter of the smallest disks detected. A closed form solution was established by assuming no rebinning and no resampling of data, with low additive noise and using a ramp filter. For the case when no such assumptions were made, a numerically calculated solution using previously reported imaging and reconstruction parameters was obtained. The detection probabilities for a range of dose and kVp values had been measured previously. These probabilities were normalized to a single dose of 56.6 mGy using the Rose-criteria-based relation to obtain a universal curve. Normalizations based on the new numerically calculated relationship were compared to the measured results. Results: The theoretical and numerical calculations have similar results and predict the detected diameter size to be inversely proportional to (dose){sup 1/3} and (dose){sup 1/2.8}, respectively. The normalized experimental curves and the associated universal plot using the new relation were not significantly different from those obtained using the Rose-criterion-based normalization. Conclusions: From numerical simulations, the authors found that the diameter of detected disks depends inversely on the cube root of the dose. For observer studies for disks larger than 4 mm, the cube root as well as square root relations appear to give similar results when used for normalization.

36 MATERIALS SCIENCE↗

Foreign object detection and removal to improve automated analysis of chest radiographs

Purpose: Chest radiographs commonly contain projections of foreign objects, such as buttons, brassier clips, jewellery, or pacemakers and wires. The presence of these structures can substantially affect the output of computer analysis of these images. An automated method is presented to detect, segment, and remove foreign objects from chest radiographs.Methods: Detection is performed using supervised pixel classification with a kNN classifier, resulting in a probability estimate per pixel to belong to a projected foreign object. Segmentation is performed by grouping and post-processing pixels with a probability above a certain threshold. Next, the objects are replaced by texture inpainting.Results: The method is evaluated in experiments on 257 chest radiographs. The detection at pixel level is evaluated with receiver operating characteristic analysis on pixels within the unobscured lung fields and an A{sub z} value of 0.949 is achieved. Free response operator characteristic analysis is performed at the object level, and 95.6% of objects are detected with on average 0.25 false positive detections per image. To investigate the effect of removing the detected objects through inpainting, a texture analysis system for tuberculosis detection is applied to images with and without pathology and with and without foreign object removal. Unprocessed, the texture analysis abnormality score of normal images with foreign objects is comparable to those with pathology. After removing foreign objects, the texture score of normal images with and without foreign objects is similar, while abnormal images, whether they contain foreign objects or not, achieve on average higher scores.Conclusions: The authors conclude that removal of foreign objects from chest radiographs is feasible and beneficial for automated image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗