Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Neutron Interrogation System For Underwater Threat Detection And Identification

Wartime and terrorist activities, training and munitions testing, dumping and accidents have generated significant munitions contamination in the coastal and inland waters in the United States and abroad. Although current methods provide information about the existence of the anomaly (for instance, metal objects) in the sea bottom, they fail to identify the nature of the found objects. Field experience indicates that often in excess of 90% of objects excavated during the course of munitions clean up are found to be non-hazardous items (false alarm). The technology to detect and identify waterborne or underwater threats is also vital for protection of critical infrastructures (ports, dams, locks, refineries, and LNG/LPG). We are proposing a compact neutron interrogation system, which will be used to confirm possible threats by determining the chemical composition of the suspicious underwater object. The system consists of an electronic d-T 14-MeV neutron generator, a gamma detector to detect the gamma signal from the irradiated object and a data acquisition system. The detected signal then is analyzed to quantify the chemical elements of interest and to identify explosives or chemical warfare agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The x-ray calibration facility of the laser integration line in the 0.9-10 keV range: The high energy x-ray source and some applications

The laser integration line (LIL) located at CEA-CESTA is equipped with x-ray plasma diagnostics using different kinds of x-ray components such as filters, mirrors, crystals, detectors, and cameras. The CEA-DAM of Arpajon is currently developing x-ray calibration methods and carrying out absolute calibration of LIL x-ray photodetectors. To guarantee LIL measurements, detectors such as x-ray cameras must be regularly calibrated close to the facility. A new x-ray facility is currently available to perform these absolute x-ray calibrations. This paper presents the x-ray tube based high energy x-ray source delivering x-ray energies ranging from 0.9 to 10 keV by means of an anode barrel. The purpose of this source is mainly to calibrate LIL x-ray cameras but it can also be used to measure x-ray filter transmission of plasma diagnostics. Different x-ray absolute calibrations such as x-ray streak and framing camera yields, x-ray charge-coupled device quantum efficiencies, and x-ray filter transmissions are presented in this paper. A x-ray flat photocathode detector sensitivity calibration recently performed for a CEA Z-pinch facility is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics for the optimization of an 11 keV inverse Compton scattering x-ray source

In a scope of a collaboration between Thales Communications and Security and CEA DAM DIF, 11 keV Xrays were produced by inverse Compton scattering on the ELSA facility. In this type of experiment, X-ray observation lies in the use of accurate electron and laser beam interaction diagnostics and on fitted X-ray detectors. The low interaction probability between < 100 {mu}m width, 12 ps [rms] length electron and photon pulses requires careful optimization of pulse spatial and temporal covering. Another issue was to observe 11 keV X-rays in the ambient radioactive noise of the linear accelerator. For that, we use a very sensitive detection scheme based on radio luminescent screens.

43 PARTICLE ACCELERATORS↗

Thermographic inspection of massive structures

Nondestructive Evaluation of concrete structures is a growing concern for the nuclear industry as well as for many other industries. As critical concrete components continue to age, the ability to assess the health and suitability for continued service has become a key consideration. In some cases, repair of these structures is difficult and expensive, while replacement is prohibitively expensive or, in some cases, not feasible. Therefore, the ability to inspect these key assets is a primary concern, especially in the nuclear industry. Due to the large size of containment buildings, cooling towers, and other large concrete assets, the ability to rapidly inspect for defects of concern is very desirable. Thermographic inspection appears to have the required ability to rapidly inspect large structures to ascertain the location and size of many of the defects of concern. This ability was demonstrated by performing a thermographic inspection of a large concrete dam in 2 days.

42 ENGINEERING↗

Realizing a supercapacitor in an electrical circuit

Capacitors are commonly used in electronic resonance circuits; however, capacitors have not been used for storing large amounts of electrical energy in electrical circuits. Here, we report a superior RC circuit which serves as an electrical storage system characterized by quick charging and long-term discharging of electricity. The improved energy storage characteristics in this mixed electric circuit (R{sub 1} + R{sub 2}C{sub 1}) with small resistor R{sub 1}, large resistor R{sub 2}, and large capacitor C{sub 1} are derived from the damming effect by large R{sub 2} in simple parallel R{sub 2}C{sub 1} circuit. However, no research work has been carried out previously on the use of capacitors as electrical energy storage devices in circuits. Combined with nanotechnology, we hope that our finding will play a remarkable role in a variety of applications such as hybrid electric vehicles and backup power supplies.

25 ENERGY STORAGE↗

Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the “PETawatt Aquitaine Laser”

Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold Spray NDE for Porosity and Other Process Anomalies

This paper describes a technology review of non-destructive examination (NDE) methods that can be applied to cold spray coatings. Cold spray is a process for depositing metal powder at high velocity so that it bonds to the substrate metal without significant heating that would be likely to cause additional residual tensile stresses. Coatings in the range from millimeters to centimeters are possible at relatively high deposition rates. Cold spray coatings that may be used for hydroelectric components that are subject to erosion, corrosion, wear, and cavitation damage are of interest. The topic of cold spray NDE is treated generally however and may be considered applicable to virtually any cold spray application except where there are constraints of the hydroelectric component application that bear special consideration. Hydroelectric turbine components are primarily made from low carbon and austenitic stainless steels. They are typically very large components that are partially assembled on-site. Transport of these components within the hydroelectric facility and away from the hydroelectric facility is challenging due to the component’s size and weight, high cost of disassembly, and the confined space of the dam. One method for prolonging component life is application of cold spray and thermal powder metal coatings to the components most susceptible to erosion, corrosion, cracking, and mechanical wear. Process controls and visual inspections have historically been applied to cold spray application; however, quantitative NDE could detect anomalies not readily apparent from such a visual examination. Optical profilometry, Eddy current, ultrasound, and hardness tests are shown for one set of good, fair, and poor Nickle-Chrome (NiCr) on 304 stainless steel (304SS) cold spray samples to demonstrate inspection possibilities. The primary indicator of cold spray quality is the cold spray porosity that is most directly measured with witness-sample destructive examinations (DE) – mostly photo-micrographs. These DE generated porosity values are correlated with optical profilometry, eddy current, ultrasound, and hardness test NDE methods to infer the porosity and other Information of interest. These parameters of interest primarily include: • Porosity primarily caused by improper process conditions (temperature, gas velocity, spray standoff, spray angle, powder size, condition, surface cleanliness, surface oxide, etc.). • Presence/absence of the cold spray coating including possible over-sprayed voids • Coating thickness Optical profilometry measurements of surface roughness trended with porosity plus if compared with a reference measurement or reference drawing would provide information on the coating thickness. Ultrasound could provide similar surface profile information plus attenuation measurements trended with porosity. The ultrasound measurements however may be limited to geometries where the substrate back-wall is normal to the cold spray surface and not too thick. Eddy current showed a strong correlation with porosity. Eddy currents can also be sensitive to cracks and do not need fluid coupling to make measurements. Eddy currents however are not sensitive to coating thicknesses in most cases. Vickers hardness measurements also tracked well with porosity. These types of hardness measurements however are also not sensitive to coating thickness. An NDE program may include multiple measurements. Acknowledgement: This work is sponsored by Bonneville Power Administration (BPA) under their technology innovation project program. Such support does not constitute BPA endorsement of views expressed in this work.

Glass, Samuel W.↗

FreeMHD: Validation and verification of the open-source, multi-domain, multi-phase solver for electrically conductive flows

The extreme heat fluxes in the divertor region of tokamaks may require an alternative to solid plasma-facing components, for the extraction of heat and the protection of the surrounding walls. Flowing liquid metals are proposed as an alternative, but raise additional challenges that require investigation and numerical simulations. Free surface designs are desirable for plasma-facing components, but steady flow profiles and surface stability must be ensured to limit undesirable interactions with the plasma. Previous studies have mainly used steady-state, 2D, or simplified models for internal flows and have not been able to adequately model free-surface liquid metal (LM) experiments. Therefore, FreeMHD has been recently developed as an open-source magnetohydrodynamics (MHD) solver for free-surface electrically conductive flows subject to a strong external magnetic field. The FreeMHD solver computes incompressible free-surface flows with multi-region coupling for the investigation of MHD phenomena involving fluid and solid domains. The model utilizes the finite-volume OpenFOAM framework under the low magnetic Reynolds number approximation. FreeMHD is validated using analytical solutions for the velocity profiles of closed channel flows with various Hartmann numbers and wall conductance ratios. Next, experimental measurements are then used to verify FreeMHD, through a series of cases involving dam breaking, 3D magnetic fields, and free-surface LM flows. These results demonstrate that FreeMHD is a reliable tool for the design of LM systems under free surface conditions at the reactor scale. Furthermore, it is flexible, computationally inexpensive, and can be used to solve fully 3D transient MHD flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Injury and mortality of two Mekong River species exposed to turbulent shear forces

Global hydropower development is one solution proposed to address the increase in energy needs. However, hydropower-related impacts on riverine ecological systems are not well understood. The Mekong River Basin (MRB) is one of the world’s largest waterways and is presently experiencing significant hydropower expansion. It is also one of the most biodiverse rivers; serving as home to many species that are blocked or hindered by the development of dams. One source of injury and mortality for downstream moving fishes is passage through the turbine environment where fishes may be exposed to several physical stressors (e.g. shear forces, rapid decompression, blade strike and turbulence). The current study sought to understand the susceptibility of blue gourami ( Trichopodus trichopterus ) and iridescent shark ( Pangasianodon hypophthalmus ) to shear forces. Fishes were exposed to an underwater jet with velocities up to 21.3 m s –1 (equating to strain rates of up to 1185 s –1 ) and were assessed for behavioural effects, injuries and mortality. Overall, it was determined that both species were susceptible to the shear forces applied in this study and the effects were more pronounced at higher strain rates. Gouramis were more susceptible than sharks. Furthermore to minimise impacts on these species, shear forces within turbines should not exceed critical limits.

60 APPLIED LIFE SCIENCES↗

Predicting hydraulic structure-induced barotrauma in Australian fish species

When fish pass downstream through river infrastructure, such as dams and weirs, barotrauma may occur due to rapid decompression. In severe cases, barotrauma may lead to mortality. Different species likely respond differently to these decompressions. Therefore, to predict barotrauma for a specific species, surrogate species may not be a valid approach, and it may be necessary to examine each species individually. For this study, Australian bass and carp gudgeon were exposed to a range of rapid decompressions using hyper/hypobaric hydro-chambers and examined for injuries and mortality. Rapid decompression data from these two fish species, in addition to previously examined Murray cod and silver perch were evaluated to determine which injuries were highly associated with and likely to predict mortality. Dose-response logistic regressions models were developed for each species to predict injury and mortality over a range of rapid decompressions. These models are valuable for estimating injury and mortality rates for fish passing though river infrastructure and can be applied to specific sites where pressure profiles have been developed. Applying these models to current and future infrastructure can provide important insight into what measures or design alterations may be necessary to reduce negative impacts of infrastructure on fish populations.

Pflugrath, Brett D.↗

It’s a catfish! Novel approaches are needed to study the effects of rapid decompression on benthic species

Barotrauma due to rapid decompression has been recorded as the most common injury among fish captured in the tailrace of hydropower dams in Brazil, with catfishes representing the majority of them. Nevertheless, studies investigating barotrauma on catfish are scarce, with the majority determining dose-response curves and thresholds of pressure changes for nektonic species as salmonids. Experiments conducted with Pimelodus pictus showed that the current hypo-hyperbaric chambers used to study barotrauma in nektonic species have limitations when applied to benthic groups. The negative buoyancy showed by the catfish prevent the definition of the acclimation pressure of the fish prior to exposure to decompression and, therefore, hinder calculation of the ratio of pressure change (RPC). RPC has been considered the main factor explaining the likelihood of barotrauma on fish. Since its calculation is restricted for benthic species, new approaches deemed to be needed to complement barotrauma studies with this group. We aimed to discuss the limitations observed for studies with benthonic species and present potential methods to overcome them. The diversification of approaches for barotrauma studies with benthonic species is critical to provide information for the development of mitigation and new turbine designs that would improve protection of this group.

Do Vale Beirao, Bernardo↗

Movement and collision of Lagrangian particles in hydro-turbine intakes: a case study

Studies of the stress/survival of migratory fish during downstream passage through operating hydro-turbines are normally conducted to determine the fish-friendliness of units. One field approach consisting of recording extreme hydraulics with autonomous sensors is largely sensitive to the conditions of sensor release and the initial trajectories at the turbine intake. This study applies a modelling strategy based on flow simulations using computational fluid dynamics and Lagrangian particle tracking to represent the travel of live fish and autonomous sensor devices through hydro-turbine intakes. For the flow field calculation, the simulations were conducted with both a time-averaging turbulence model and an eddy-resolving technique. For the particle tracking calculation, different modelling assumptions for turbulence forcing, mass formulation, buoyancy, and release condition were tested. The modelling assumptions are evaluated with respect to data sets collected using a laboratory physical model and an autonomous sensor device deployed at Ice Harbor Dam (Snake River, State of Washington, U.S.A.) at the same discharge and release point as in the present computer simulations. We found an acceptable agreement between the simulated results and observed data and discuss relevant features of Lagrangian particle movement that are critical in turbine design and in the experimental design of field studies.

CFD↗

MASTODON: An Open-Source Software for Seismic Analysis and Risk Assessment of Critical Infrastructure

Seismic analysis and risk assessment of safety-critical infrastructure like hospitals, nuclear power plants, dams, and facilities handling radioactive materials involve computationally intensive numerical models and coupled multiphysics scenarios. They are also performed in a strict regulatory environment that requires high software quality assurance standards, and in the case of safety-related nuclear facilities, a conformance to the American Society of Mechanical Engineers Nuclear Quality Assurance (NQA-1) standard. This paper introduces the open-source finite-element software, MASTODON (Multi-hazard Analysis of Stochastic Time-Domain Phenomena), which implements state-of-the-art seismic analysis and risk assessment tools in a quality-controlled environment. MASTODON is built on MOOSE (Multi-physics Object-Oriented Simulation Environment), which is a highly parallelizable, NQA-1 conforming, coupled multiphysics, finite-element framework developed at Idaho National Laboratory. MASTODON is capable of fault rupture and source-to-site wave propagation using the domain reduction method, nonlinear site response, and soil-structure interaction analysis, implicit and explicit time integration, automated stochastic simulations, and seismic probabilistic risk assessment. When coupled with other MOOSE applications, MASTODON can also solve strongly and weakly coupled multiphysics problems. This paper presents a summary of the capabilities of MASTODON and some demonstrative examples.

42 ENGINEERING↗

Monitoring Stock-Specific Abundance, Run Timing, and Straying of Chinook Salmon in the Columbia River Using Genetic Stock Identification (GSI)

Abstract Genetic stock identification (GSI) provides a method of characterizing stock-specific abundance, run timing, and straying as they pertain to the population demographics and behavior of both hatchery and wild fish and thus assists with fisheries management. In this study, tissues were collected and genotyped at 13 microsatellite loci from adult Chinook Salmon Oncorhynchus tshawytscha that passed Bonneville Dam during four consecutive migration years (2004–2007). GSI methods were used to estimate the proportions of stocks in a broad genetic baseline, with high-density coverage of Chinook Salmon across the eastern Pacific Rim. The estimates of abundance for interior Columbia River stocks showed widespread decline consistent with a shift to poor ocean conditions during the years when the fish in this study were at sea, but divergent stock- and age-specific patterns were also observed. For example, the upper Columbia River spring-run stock experienced a unique net gain in abundance during this period, and the interior Columbia River summer–fall-run stock experienced a delayed decline of 4-year-olds. Stocks with early run timing shifted to later migrations. However, run timing distributions did not shift unidirectionally for all stocks across years, and stock membership in three major run timing categories was maintained. Of 9,215 total adults sampled, 27 (0.3%) were out-of-basin strays and a quarter of the strays were putatively of wild origin. The general concordance of GSI results with those based on more traditional methods supports the effectiveness of GSI as a tool for fisheries management. Received May 5, 2013; accepted October 23, 2013 Published online February 10, 2014

Hess, Jon E.↗

Performance of Spring Chinook Salmon Reared in Acclimation Ponds for Two and Four Months before Release

Abstract Seasonal temperature cues may play an important role in the parr–smolt transformation of Pacific salmon Oncorhynchus spp., but salmon reared in groundwater-supplied hatcheries with seasonally stable water temperatures do not experience these cues. In this study, conducted over six release years, hatchery spring Chinook salmon O. tshawytscha that were initially reared in a groundwater-supplied hatchery were transferred to acclimation ponds supplied with surface water either in November (November transfer [NT]) or January (January transfer [JT]) for rearing at ambient water temperatures prior to release into the Umatilla River, Oregon, in early March. After stream release, we monitored out-migration travel times and survival to John Day Dam (JDD) by using passive integrated transponder tags in a subsample of each release group. Across all release groups, median travel time was slower for NT groups (51 d) than for JT groups (46 d); significant differences were observed in five of six release years. Average survival probabilities were 15% higher for NT groups than for JT groups, although this difference was not significant. We used recoveries of coded wire tags to estimate smolt-to-adult survival (SAS) and straying for NT and JT groups. Average SAS over the study was 27% higher for NT groups (0.76%) than for JT groups (0.60%), but straying was minimal for both types of release group. We found no significant linear relationship between SAS and travel time or survival to JDD. Adult returns of NT groups had a slightly older age distribution than those of JT groups. Our results suggest that for salmon juveniles reared in groundwater-supplied hatcheries, providing an overwinter period of exposure to ambient water temperatures should optimize postrelease survival. We also discuss some risks and benefits to winter rearing in acclimation ponds for managers that are considering this approach.

Clarke, Lance R.↗

The effects of sampling location and turbulence on discharge estimates in short converging turbine intakes

Standards provide recommendations for best practices when installing current meters to measure fluid flow in closed conduits. A central guideline requires the velocity distribution to be regular and the flow steady. Because of the nature of the short converging intakes typical of low-head hydroturbines, these assumptions may be invalid if current meters are intended to be used to estimate discharge. Usual concerns are (1) the effects of the number of devices, (2) the sampling location and (3) the high turbulence caused by blockage from submersible traveling screens usually deployed for safe downstream fish passage. These three effects were examined in the present study by using 3D simulated flow fields in both steady-state and transient modes. In the process of describing an application at an existing hydroturbine intake at Ice Harbor Dam, the present work outlined the methods involved, which combined computational fluid dynamics, laboratory measurements in physical models of the hydroturbine, and current meter performance evaluations in experimental settings. The main conclusions in this specific application were that a steady-state flow field sufficed to determine the adequate number of meters and their location, and that both the transverse velocity and turbulence intensity had a small impact on estimate errors. However, while it may not be possible to extrapolate these findings to other field conditions and measuring devices, the study laid out a path to conduct similar assessments in other applications.

computational fluid dynamics (CFD)↗

Piezoelectric transducer design for a miniaturized injectable acoustic transmitter

Acoustic telemetry has been an important tool in the last 20 years for studying fish survival and migration behaviors during and after dam passage. This technology uses implantable acoustic transmitters as tags to three-dimensionally track the movement of fish. However, the relatively large weights and sizes of commercially available transmitters limit the populations of fish that could be studied. The surgical implantation procedures required may also injure fish and also incur a significant amount of labor. Therefore, a smaller, lighter, and injectable tag was needed, and similar or better acoustic performance and service life over that provided by existing commercial tags was desired. To develop such a small transmitter, a number of technical challenges, including design optimization of the piezoelectric transducer, needed to be overcome. The goal of our efforts to optimize the transducer focused on improving the average source level in the 180° range in which the transmitter was facing the receiving hydrophone, so as to increase the transmitter’s detection probability. This paper reports the techniques that were explored and developed to achieve this goal. We found that a novel off-center tube transducer improved the average source level of the front half of the transducer by 1.5 dB. An acoustic reflector attached to the back of the transducer also improved the source level by 3 dB when the transducer was pointed toward the receiving hydrophone, although the source level on the sides of the transducer was reduced. We found that too small a gap between the transducer and the component placed behind it resulted in distortion of the beam pattern. To overcome that issue, we connected a tuning inductor in series with the transducer to help optimize the source level. Furthermore, the findings and techniques developed in this work contributed to the successful development and implementation of a new injectable transmitter.

42 ENGINEERING↗

Simulation of hydropower at subcontinental to global scales: a state-of-the-art review

Abstract Hydroelectric power is playing a new and often expanded role in the world’s major power grids, offering low carbon generating capacity in industrializing, dam-building economies while providing reserve and flexibility to co-manage fledgling wind and solar resources in high income countries. Driven by river flows, conventional hydropower is exposed to the vagaries of weather and climate, motivating drought and climate change hydropower impact studies at large spatial scales. Here we review methods of climate-driven hydropower simulation at large spatial scales, specifically multi-basin regions to global. We identify four types of approach based on complexity of tools and richness of data applied to the problem. Since the earliest attempts to model climate-driven hydropower at continental scale almost two decades ago, the field has transitioned from one of scientific curiosity to practical application, with studies increasingly motivated by the need to inform power grid expansion planning and operation. As the hydrological and water management models used in large-scale hydropower studies become more sophisticated, new opportunities will emerge to study the impacts of changing hydropower on power system reliability and performance at large power grid scale. To grasp these opportunities, the water resources community must continue to enhance data and models for representing river flows and anthropogenic water use and management at subcontinental to global scales.

13 HYDRO ENERGY↗