Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Temporal study of wake formation behind a conducting body

The temporal evolution of the wake of a conducting body is studied experimentally in a pulsed plasma device. Three-dimensional measurements of the plasma potential, density, particle energy distribution, and ion currents are measured throughout the near- and mid-wake regions during the wake formation. It is found that the potential behind the conducting body is initially negative. This negative potential is caused by the higher mobility of the electrons, allowing them to flow into the ion free wake region. The negative potential in the wake region induces an electric field that pulls ions into the region behind the conducting body. However, the dominant factor in determining the length of the near wake is the thermal energy spread of the ions. At later times, as the sheath forms around the conducting body, ions are deflected by the potential gradient in the sheath region. This deflection, in addition to the thermal energy spread of the ions, determines the length of the near wake.

Meassick, S.↗

Remote Sensing of Earth's Surface and Atmosphere: Interdisciplinary Scientific Commission A of the COSPAR Plenary Meeting, 29th, Washington, DC, 28 Aug. - 5 Sep., 1992

This conference reviewed the recent developments in remote monitoring of surface temperatures, which will be significant in future global change studies. Various techniques to derive surface temperature from existing and future remote sensing systems such as earth observing system (EOS) are discussed. Five sessions were held: (1) The nature of the problem of remote sensing of surface temperatures; (2) Surface temperature measurements from current satellites; (3) Modeling and surface observations of various techniques to measure temperature and/or emissivity, modeling of vegetation; (4) The effects of variable spectral emissivity from the determination of surface kinetic temperature using multispectral thermal infrared measurements; and (5) Future satellite systems including EOS/ASTER, EOS/MODIS-N, and EOS/AIRS.

Kahle, A. B.↗

Application of acoustic-Doppler current profiler and expendable bathythermograph measurements to the study of the velocity structure and transport of the Gulf Stream

The degree to which Acoustic-Doppler Current Profiler (ADCP) and expendable bathythermograph (XBT) data can provide quantitative measurements of the velocity structure and transport of the Gulf Stream is addressed. An algorithm is used to generate salinity from temperature and depth using an historical Temperature/Salinity relation for the NW Atlantic. Results have been simulated using CTD data and comparing real and pseudo salinity files. Errors are typically less than 2 dynamic cm for the upper 800 m out of a total signal of 80 cm (across the Gulf Stream). When combined with ADCP data for a near-surface reference velocity, transport errors in isopycnal layers are less than about 1 Sv (10 to the 6th power cu m/s), as is the difference in total transport for the upper 800 m between real and pseudo data. The method is capable of measuring the real variability of the Gulf Stream, and when combined with altimeter data, can provide estimates of the geoid slope with oceanic errors of a few parts in 10 to the 8th power over horizontal scales of 500 km.

Joyce, T. M.↗

Time-averaged current analysis of a thunderstorm using ground-based measurements

The amount of upward current provided to the ionosphere by a thunderstorm that appeared over the Kennedy Space Center (KSC) on July 11, 1978, is reexamined using an analytic equation that describes a bipolar thunderstorm's current contribution to the global circuit in terms of its generator current, lightning currents, the altitudes of its charge centers, and the conductivity profile of the atmosphere. Ground-based measurements, which were obtained from a network of electric field mills positioned at various distances from the thunderstorm, were used to characterize the electrical activity inside the thundercloud. The location of the lightning discharges, the type of lightning, and the amount of charge neutralized during this thunderstorm were computed through a least squares inversion of the measured changes in the electric fields following each lightning discharge. These measurements provided the information necessary to implement the analytic equation, and consequently, a time-averaged estimate of this thunderstorm's current contribution to the global circuit was calculated. From these results the amount of conduction current supplied to the ionosphere by this small thunderstorm was computed to be less than 25% of the time-averaged generator current that flowed between the two vertically displaced charge centers.

Driscoll, Kevin T.↗

Measurements of field-aligned currents in a multiple auroral arc system

A rocket-borne experiment to study the currents associated with a system of multiple auroral arcs was conducted at Poker Flat, Alaska, at 1122 UT on Feb. 2, 1972. The magnetic field in the vicinity of the auroral system was measured with a cesium vector magnetometer. Possible configurations were inferred by constructing model current systems that reproduced the magnetic field variations measured along the flight path. The data are interpreted in terms of a model current system consisting of two eastward electrojets and one westward electrojet and three pairs of oppositely directed Birkeland sheet currents, all lying in a plane approximately parallel to the auroral arcs. Sheet thicknesses ranged from 20 to 60 km and current densities from 10 to 45 microampere/sq m; the electrojet currents ranged from 1000 to 2000 A. A possible alternate model consisted of four pairs of sheets whose thicknesses range from 10 to 40 km with current densities from 10 to 90 microampere/sq m. There was quite good agreement between the locations of the visual arcs and the upward current sheets. The overall current configuration is discussed in view of the theoretical models constructed by Atkinson and Sato and Holzer and of other observations.

Sesiano, J.↗

Trielectrode capacitive pressure transducer

A capacitive transducer and circuit especially suited for making measurements in a high-temperature environment are described. The transducer includes two capacitive electrodes and a shield electrode. As the temperature of the transducer rises, the resistance of the insulation between the capacitive electrode decreases and a resistive current attempts to interfere with the capacitive current between the capacitive electrodes. The shield electrode and the circuit coupled there reduce the resistive current in the transducer. A bridge-type circuit coupled to the transducer ignores the resistive current and measures only the capacitive current flowing between the capacitive electrodes.

Coon, G. W.↗

Sensors for ceramic components in advanced propulsion systems

This report includes: (1) a survey of the current methods for the measurement of surface temperature of ceramic materials suitable for use as hot section flowpath components in aircraft gas turbine engines; (2) analysis and selection of three sensing techniques with potential to extend surface temperature measurement capability beyond current limits; and (3) design, manufacture, and evaluation of the three selected techniques which include the following: platinum rhodium thin film thermocouple on alumina and mullite substrates; doped silicon carbide thin film thermocouple on silicon carbide, silicon nitride, and aluminum nitride substrates; and long and short wavelength radiation pyrometry on the substrates listed above plus yttria stabilized zirconia. Measurement of surface emittance of these materials at elevated temperature was included as part of this effort.

Koller, A. C.↗

High Current Hollow Cathode Plasma Plume Measurements

Plasma plume measurements are reported for a hollow cathode assembly (HCA) operated at discharge currents of 50, 70, and 100 A at xenon flow rates between 19 - 46 standard cubic centimeter per minute. The HCA was centrally mounted in the NASA-300MS Hall Thruster and was operated in the "spot" and "plume" modes with additional data taken with an applied magnetic field. Langmuir probes, retarding potential analyzers, and optical emission spectroscopy were employed to measure plasma properties near the orifice of the HCA and to assess the charge state of the near-field plasma. Electron temperatures (2-6 electron volt) and plasma potentials are consistent with probe-measured values in previous investigations. Operation with an applied-field yields higher discharge voltages, increased Xe III production, and increased signals from the 833.5 nm C I line. While operating in plume mode and with an applied field, ion energy distribution measurements yield ions with energies significantly exceeding the applied discharge voltage. These findings are correlated with high-frequency oscillations associated with each mode.

High frequency analysis↗

Laser damage tests on InSb photodiodes at 1.064 micron and 0.532 micron

InSb photodiodes were examined for performance degradation after pulsed laser illumination at 0.532 micron and 1.064 micron. Incident laser powers ranged from 6 x 10 exp-18 micron-watts to 16 micron-watts in a 50 pm diameter spot. Dark current and spectral response were both measured before and after illumination. Dark current measurements were taken with the diode blanked off and viewing only 77 K surfaces. Long term stability tests demonstrated that the blackbody did not exhibit long term drifts. Other tests showed that room temperature variations did not affect the diode signal chain or the digitization electronics used in data acquisition. Results of the experiment show that the diodes did not exhibit changes in dark current or spectral response performance as a result of the laser illumination. A typical change in diode spectral response (before/after laser exposure) was about 0.2 percent +/- 0.2 percent.

Bearman, G. H.↗

Status Update on the High Precision Isotopic Measurements on High Burnup LWR Fuel in 2020

The US Department of Energy (DOE) Office of Nuclear Energy (NE) is currently investigating the feasibility of directly disposing dual-purpose (storage and transportation) canisters (DPCs) in a spent nuclear fuel (SNF) repository. Criticality during the repository performance period (10,000 years or more) is one of the major concerns related to direct disposal of DPCs, specifically as the system undergoes degradation in the repository environment and timeframe. Oak Ridge National Laboratory (ORNL) is developing an as-loaded criticality analysis methodology using full (actinides + fission products) burnup credit that exploits the inherent criticality margin associated with actual canister-specific loading configuration. Burnup credit criticality analysis requires validation of the depletion/decay codes used to generate the burned isotopic inventory of an assembly by comparing the code-predicted inventory with experimentally determined isotopic data. Currently, isotopic measurement data for boiling water reactors (BWR) SNF are limited, and additional measurements will be highly beneficial for BWR burnup credit analysis, which is essential to demonstrate disposability of BWR DPCs. Moreover, new pressurized water reactor (PWR) samples of isotopic measurements will expand the PWR sample population and consequently will greatly improve sample statistics. In turn, this will reduce uncertainty in the computational determination of the isotopic composition of commercial SNF and eliminate additional penalties currently used for lack of data. As part of the isotopic analysis task, eight diverse, high burnup (HBU) samples from several PWR rods are being dissolved and isotopically analyzed to provide high-quality measurement data for PWR SNF to reducing the uncertainties associated with PWR isotopic depletion validation. The isotopics of interest focus on nuclides important to burnup credit, shielding, and decay heat in PWR SNF. Additionally, eight high burnup BWR fuel samples from the Limerick nuclear power plant have been identified for measurement to support reducing uncertainties associated with BWR isotopic depletion validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observing differential spin currents by resonant inelastic X-ray scattering

Controlling spin currents, that is, the flow of spin angular momentum, in small magnetic devices, is the principal objective of spin electronics, a main contender for future energy-efficient information technologies. A pure spin current has never been measured directly because the associated electric stray fields and/or shifts in the non-equilibrium spin-dependent distribution functions are too small for conventional experimental detection methods optimized for charge transport. Here we report that resonant inelastic X-ray scattering (RIXS) can bridge this gap by measuring the spin current carried by magnons—the quanta of the spin wave excitations of the magnetic order—in the presence of temperature gradients across a magnetic insulator. This is possible due to the sensitivity of the momentum- and energy-resolved RIXS intensity to minute changes in the magnon distribution under non-equilibrium conditions. Furthermore, we use the Boltzmann equation in the relaxation time approximation to extract transport parameters, such as the magnon lifetime at finite momentum, essential for the realization of magnon spintronics.

36 MATERIALS SCIENCE↗

EWTN: Quantifying Mass Transport to Enable Water Electrolyzer Architectures with Low Flow-Rate Sensitivity

To develop cost-effective and high-performing polymer electrolyte water electrolyzers (PEWEs) for gigawatt-scale applications, researchers have focused on reducing precious metal catalyst loadings and optimizing porous transport layers. However, the performance of PEWEs is also affected by system architecture. Mass transport losses are dependent on localized architecture and material interactions. In-situ measurements, such as current density distribution maps have demonstrated advantages in understanding the intricate characteristics and influence of two-phase flow within PEWEs. This study proposes the parameter of effective water transport number (EWTN) as a quantitative tool to investigate such current density distribution (CDD) measurements for PEWEs. Results show that higher flow-rates have EWTN values of 0.95 and above, indicating no mass transport limitations; while lower flow-rates with large gradients CDD have EWTN values between 0.6-0.8, indicating mass transport limited conditions. The new analysis also identified a correlation between mass transport losses due to bubble accumulation, membrane hydration, and ohmic overpotentials. To address these limitations, an unitized pin-type LGDL/flow-field design was developed, which effectively prevents local gas phase accumulation, resulting in improved mass transport characteristics. The results of this work show reduced flow-rate sensitivity with the pin-type architecture and ∼13% increased performance at 0.24 ml / min / cm 2 .

Electrochemistry↗

Improvements of a magnetic monopole detector

Modifications to our previously described detector of magnetic monopoles resulting in substantial improvements in performance have been made. The sensitivity has been increased a factor of 35 by using a sensitive magnetometer (SQUID) to measure changes in current. The modifications, new measurement techniques, and implications for past and future experiments are described.

Eberhard, P. H.↗

ATMOS: Long term atmospheric measurements for mission to planet Earth

A long-term, space-based measurement program, together with continued balloon and aircraft-borne investigations, is essential to monitor the predicted effects in the atmosphere, to determine to what extent the concentration measurements agree with current models of stratospheric chemistry, and to determine the condition of the ozone layer. The Atmospheric Trace Molecule Spectroscopy (ATMOS) Experiment is currently making comprehensive, global measurements of Earth's atmosphere as part of the Atmospheric Laboratory for Applications and Science (ATLAS) program on the Space Shuttle. Part of NASA's Mission to Planet Earth, ATLAS is a continuing series of missions to study Earth and the Sun and provide a more fundamental understanding of the solar influences on Earth's atmosphere. The ATMOS program, instruments, and science results are presented.

Source record↗

Ultrasound as a Noninvasive Method to Assess Changes of Intracranial Volume and Pressure During Simulated Microgravity

Headaches are commonly experienced by astronauts in microgravity and by subjects undergoing head-down tilt (simulated microgravity on Earth). Exposure to microgravity probably elevates blood pressure and flow in the head which may increase intracranial volume (ICV) and pressure (ICP) and in turn cause headache. Due to the slightly compliant nature of the cranial vault and the encasement of brain and its vasculature within this vault, any increase of ICV will increase ICP and slightly distend the cranium. Previous studies document perivascular edema and increased ICP in rhesus monkeys during head-down tilt. Elevated ICP has also been reported in humans during head-down tilt. ICP measurements in healthy humans are rare because of the invasiveness of currently-available measurement techniques. Therefore, we proposed a noninvasive ultrasound technique to assess changes of ICV and JCP. The ultrasound principle is based on compliance of the cranial vault. A 450 kHz ultrasound stimulus is transmitted through the cranium by a transducer every 7.5-10 msec. The ultrasound wave enters the brain tissue, reflects off the opposite side of the cranium and is received by the same transducer. The detected wave is compared for phase quadrature (90 deg.to transmitted wave). Because the electronic circuitry of the device maintains a 90 deg. phase (phi), any alterations in the detected wave caused by an increase of ICV and ICP will be reflected as a change in the wave frequency. Phase shift is directly proportional to path length of the wave, DELTA x, which is expressed as DELTA x = phi lambda/2 pi where lambda is wavelength. Elevated ICV and ICP expand the cranial vault and increase path length of the wave (a measure of intracranial distance). Increased path length equals reduced frequency of the detected wave. Reduced frequency is then related to elevated ICP. This technique has potential uses for ICP studies of astronauts in space and head trauma patients on Earth.

Murthy, G.↗

Combined Infrared Stereo and Laser Ranging Cloud Measurements from Shuttle Mission STS-85

Multi-angle remote sensing provides a wealth of information for earth and climate monitoring. And, as technology advances so do the options for developing instrumentation versatile enough to meet the demands associated with these types of measurements. In the current work, the multiangle measurement capability of the Infrared Spectral Imaging Radiometer is demonstrated. This instrument flew as part of mission STS-85 of the space shuttle Columbia in 1997 and was the first earth-observing radiometer to incorporate an uncooled microbolometer array detector as its image sensor. Specifically, a method for computing cloud-top height from the multi-spectral stereo measurements acquired during this flight has been developed and the results demonstrate that a vertical precision of 10.6 km was achieved. Further, the accuracy of these measurements is confirmed by comparison with coincident direct laser ranging measurements from the Shuttle Laser Altimeter. Mission STS-85 was the first space flight to combine laser ranging and thermal IR camera systems for cloud remote sensing.

Lancaster, Redgie S.↗

Rapid Polymer Sequencer

Method and system for rapid and accurate determination of each of a sequence of unknown polymer components, such as nucleic acid components. A self-assembling monolayer of a selected substance is optionally provided on an interior surface of a pipette tip, and the interior surface is immersed in a selected liquid. A selected electrical field is impressed in a longitudinal or transverse direction at the tip, a polymer sequence is passed through the tip, and a change in an electrical current signal is measured as each polymer component passes through the tip. Each measured change in electrical current signals is compared with a database of reference signals, with each reference signal identified with a polymer component, to identify the unknown polymer component. The tip preferably has a pore inner diameter of no more than about 40 nm and is prepared by heating and pulling a very small section of a glass tubing.

Stolc, Viktor↗