Electron nanoprobe induced oxidation: A simulation of direct-write purification

Electron beam direct-write has recently taken a large step forward with the advent of methods to purify deposits. This development has opened the door for future direct-write device prototyping and editing. In one such approach, an additional beam scanning procedure removes carbonaceous impurities via oxidation from metal–carbon deposits (e.g., PtC 5 ) in the presence of H 2 O or O 2 after deposition. So far, critical aspects of the oxidation reaction remain unclear; experiments reveal clearly that electron stimulated oxidation drives the process yet it is not understood why H 2 O purifies by a bottom-up mechanism while O 2 purifies from the top-down. The simulation results presented here suggest that the chemisorption of dissolved O 2 at buried Pt nanoparticle surfaces controls purification in the top-down case while both the high relative solubility coupled with weak physisorption of H 2 O explains the bottom-up process. Crucial too is the role that the carbonaceous contaminant itself has on the dissolution and diffusion of O 2 and H 2 O. The results pave the way for simulation driven experiments where (1) the transient densification of the deposit can be accounted for in the initial deposit design stage and (2) the deposition and purification steps can be combined.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tanks 18 And 19-F Structural Flowable Grout Fill Material Evaluation And Recommendations

Cementitious grout will be used to close Tanks 18-F and 19-F. The functions of the grout are to: 1) physically stabilize the final landfill by filling the empty volume in the tanks with a non-compressible material; 2) provide a barrier for inadvertent intrusion into the tank; 3) reduce contaminant mobility by a) limiting the hydraulic conductivity of the closed tank and b) reducing contact between the residual waste and infiltrating water; and 4) providing an alkaline, chemically reducing environment in the closed tank to control speciation and solubility of selected radionuclides. The objective of this work was to identify a single (all-in-one) grout to stabilize and isolate the residual radionuclides in the tank, provide structural stability of the closed tank and serve as an inadvertent intruder barrier. This work was requested by V. A. Chander, High Level Waste (HLW) Tank Engineering, in HLW-TTR-2011-008. The complete task scope is provided in the Task Technical and QA Plan, SRNL-RP-2011-00587 Revision 0. The specific objectives of this task were to: 1) Identify new admixtures and dosages for formulating a zero bleed flowable tank fill material selected by HLW Tank Closure Project personnel based on earlier tank fill studies performed in 2007. The chemical admixtures used for adjusting the flow properties needed to be updated because the original admixture products are no longer available. Also, the sources of cement and fly ash have changed, and Portland cements currently available contain up to 5 wt. % limestone (calcium carbonate). 2) Prepare and evaluate the placement, compressive strength, and thermal properties of the selected formulation with new admixture dosages. 3) Identify opportunities for improving the mix selected by HLW Closure Project personnel and prepare and evaluate two potentially improved zero bleed flowable fill design concepts; one based on the reactor fill grout and the other based on a shrinkage compensating flowable fill mix design. 4) Prepare samples for hydraulic property measurements for comparison to the values in the F- and H- Tank Farm Performance Assessments (PAs). 5) Identify a grout mix for the Tanks 18-F and 19-F Grout Procurement Specification. Results for two flowable zero bleed structural fill concepts containing 3/8 inch gravel (70070 Series and LP#8 Series) and a sand only mix (SO Series) are provided in this report. Tank Farm Engineering and SRNL Project Management selected the 70070 mix as the base case for inclusion in Revision 0 of the Tanks 18-F and 19-F grout procurement specification and requested admixture recommendations and property confirmation for this formulation. Lower cementitious paste mixes were formulated because the 70070 mix is over designed with respect to strength and generates more heat from hydration reactions than is desirable for mass pour application. Work was also initiated on a modification of the recommended mix which included shrinkage compensation to mitigate fast pathways caused by shrinkage cracking and poor physical bonding to the tank and ancillary equipment. Testing of this option was postponed to FY12. Mix, LP#8-16 is recommended for inclusion in the specification for furnishing and delivering tank closure grout for Tanks 18-F and 19-F. A shrinkage compensating variation of this mix, LP#16C, has not been fully developed and characterized at this time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous bi-products of research activities or airborne pathogens. As a result, building ventilation is the primary defense against unseen airborne hazards. Critical laboratory facilities already demand the need for effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently available contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers on a limited budget. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in the critical laboratory environment. In this session, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories without breaking the bank. This paper describes a low-cost solution for providing a safe, healthy building environment and reducing energy use through effective, efficient ventilation.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Unforeseen Events Alter Stewardship Strategies at the Decommissioned BONUS Reactor in Puerto Rico - 19572

The decommissioned Boiling Nuclear Superheater (BONUS) reactor northwest of Rincon, Puerto Rico, was developed as a prototype nuclear power plant to investigate the feasibility of the integral boiling superheating concept. Through a combined effort of the US Atomic Energy Commission (AEC) and the Puerto Rico Water Resources Authority (PRWRA), the reactor first achieved a controlled nuclear chain reaction in 1964 and remained operational until June 1968. It was the eighth nuclear reactor constructed in the world and one of only two boiling-water superheater reactors ever developed in the United States. Following its decommissioning in 1970, AEC, the predecessor to the US Department of Energy (DOE), and PRWRA, the predecessor to the Puerto Rico Electric Power Authority (PREPA), worked together post-closure to address the remaining residual contamination and safely open the facility to the public for science educational outreach. Presently, the DOE Office of Legacy Management (LM) has long-term stewardship responsibilities for the reactor entombment, which includes periodic site inspections of the entombment system and oversight of the Radiological Protection Program (RPP) implemented by PREPA. PREPA has responsibility for conducting radiological measurements in accordance with the approved RPP for the facility, recordkeeping and reporting, and facility control and maintenance. The entombment system has a design life of 140 years; DOE has an obligation to ensure long-term protectiveness at the site for the next 90 years until the contact dose of the entombment system reaches background conditions. As part of the long-term protectiveness strategy, in September 2000, the BONUS reactor facility was renamed the Dr. Modesto Iriarte Technology Museum, and then in 2007, the facility was listed under the National Register of Historical Places. The museum contains numerous displays that recount the history of the BONUS site, as well as the development of electric power and nuclear energy, and receives approximately 100 visitor requests each year. The best long-term strategies need to be flexible and are subject to change. As such, the long-term maintenance responsibilities at the BONUS reactor facility were formerly documented in the 2010 Letter of Agreement between LM and PREPA to reaffirm the joint commitment of long-term protectiveness. This commitment did not waiver despite two devastating hurricanes in 2017, Irma and Maria, and the recent bankruptcy filing by the territory of Puerto Rico. To address the financial uncertainties facing PREPA, secure LM's commitment to long-term stewardship liabilities in the future, and offer a level of care similar to that at other LM sites, LM has offered several strategic opportunities to ensure the long-term sustainability of the site. Both LM and PREPA share a common and long-term stewardship commitment at the BONUS reactor facility, which includes ensuring protectiveness of the entombed radiological waste material. Protection of human health and the environment is at the forefront of the DOE mission, and the beneficial reuse of legacy sites continues to be a goal of the agency. The collaborative ability of both organizations to transform a Cold War-era facility such as a former nuclear reactor to an educational center embodies a unique ability to present local history while educating future generations on LM's mission to protect human health and the environment across the 92 sites it manages. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sustaining On-going Risk Communication at the Riverton, Wyoming, Processing Site - 20310

An environmental risk assessment report has been completed to provide an updated assessment regarding current site conditions for the Riverton, Wyoming, Processing site. Argonne National Laboratory conducted the assessment in collaboration with the U.S Department of Energy (DOE) Office of Legacy Management (LM) and the Northern Arapaho Natural Resources Office (NANRO). The data quality objectives process conducted confirmed that data from plants growing on the Riverton site would be useful and would address an outstanding concern. Data available from site soil, groundwater, and surface water were also used in the assessment in conjunction with the new plant data. A plant survey was then conducted in 2018 to identify the plants at the Riverton site with known traditional Native American cultural uses for sampling and analysis. Laboratory analysis was conducted on the plant samples for the contaminants of concern. Samples were collected from plants growing on the groundwater plume area of the site, and the same was done for eight other areas not affected by the groundwater plume but still within the institutional control boundary. These eight areas served as reference areas for this study. This human health and ecological assessment update provide the quantitative risk information that was qualitatively addressed in a 1995 Risk Assessment Report on plants, livestock, and surface water exposures at the Riverton site [1]. The conditions at the Riverton site are protective of human health and the environment given the results of the update, in combination with past completed remedial action and ongoing monitoring activities and IC implementation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Formation and Aggregation of Lead Phosphate Particles: Implications for Lead Immobilization in Water Supply Systems

Phosphate is commonly added to drinking water to inhibit lead release from lead service lines and lead-containing materials in premise plumbing. Phosphate addition promotes the formation of lead phosphate particles, and their aggregation behaviors may affect their transport in pipes. In this work, lead phosphate formation and aggregation were studied under varied aqueous conditions typical of water supply systems. Under high aqueous PO 4 /Pb molar ratios (>1), phosphate adsorption made the particles more negatively charged. Therefore, enhanced stability of lead phosphate particles was observed, suggesting that although addition of excess phosphate can lower the dissolved lead concentrations in tap water, it may increase concentrations of particulate lead. Adsorption of divalent cations (Ca 2+ and Mg 2+ ) onto lead phosphate particles neutralized their negative surface charges and promoted their aggregation at pH 7, indicating that phosphate addition for lead immobilization may be more efficient in harder waters. The presence of natural organic matter (NOM, ≥ 0.05 mg C/L humic acid and ≥ 0.5 mg C/L fulvic acid) retarded particle aggregation at pH 7. Consequently, removal of organic carbon during water treatment to lower the formation of disinfection-byproducts (DBPs) may have the additional benefit of minimizing the mobility of lead-containing particles. This study provided insight into fundamental mechanisms controlling lead phosphate aggregation. Such understanding is helpful to understand the observed trends of total lead in water after phosphate addition in both field and pilot-scale lead pipe studies. Also, it can help optimize lead immobilization by better controlling the water chemistry during phosphate addition.

54 ENVIRONMENTAL SCIENCES↗

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation↗

Nanocomposite Materials for Radionuclide Sequestration from Groundwater Environments

The half-lives of radionuclides range from fractions of a second to billions of years. Since no practical method of altering radioactive decay exists, and since exposure to either the energy emitted from radioactive decay or chemical properties of radionuclides poses dire health risks, radioactive materials must be segregated and controlled. The capture, treatment, and disposition of radioactive materials remain an extraordinary challenge. In here, we focus our attention on the synthesis and characterization of a unique class of nanocomposite materials that have potential for removal of radionuclide contamination. Specifically, we report a simple approach to decorate the surface of iron-based (Fe/FexOy) material with various nano-catalysts. Specifically, copper (Cu), tin (Sn), and silver (Ag) nanoparticles were prepared through two different reduction approaches, namely, citrate and cetyltrimethylammonium bromide (CTAB) methods, on the iron-based material surface. All samples were characterized by a variety of analytical tools, which included scanning electron microscopy (SEM), electron-dispersive X-ray microanalysis (EDS), and EDS mapping to elucidate materials’ morphology as well as nano-catalysts’ loading and location on the iron-based structures.

Hunyadi Murph, Simona E.↗

Metabolic engineering to improve production of 3-hydroxypropionic acid from corn-stover hydrolysate in Aspergillus species

Fuels and chemicals derived from non-fossil sources are needed to lessen human impacts on the environment while providing a healthy and growing economy. 3-hydroxypropionic acid (3-HP) is an important chemical building block that can be used for many products. Biosynthesis of 3-HP is possible; however, low production is typically observed in those natural systems. Biosynthetic pathways have been designed to produce 3-HP from a variety of feedstocks in different microorganisms. In this study, the 3-HP β-alanine pathway consisting of aspartate decarboxylase, β-alanine-pyruvate aminotransferase, and 3-hydroxypropionate dehydrogenase from selected microorganisms were codon optimized for Aspergillus species and placed under the control of constitutive promoters. The pathway was introduced into Aspergillus pseudoterreus and subsequently into Aspergillus niger, and 3-HP production was assessed in both hosts. A. niger produced higher initial 3-HP yields and fewer co-product contaminants and was selected as a suitable host for further engineering. Proteomic and metabolomic analysis of both Aspergillus species during 3-HP production identified genetic targets for improvement of flux toward 3-HP including pyruvate carboxylase, aspartate aminotransferase, malonate semialdehyde dehydrogenase, succinate semialdehyde dehydrogenase, oxaloacetate hydrolase, and a 3-HP transporter. Overexpression of pyruvate carboxylase improved yield in shake-flasks from 0.09 to 0.12 C-mol 3-HP C-mol -1 glucose in the base strain expressing 12 copies of the β-alanine pathway. Deletion or overexpression of individual target genes in the pyruvate carboxylase overexpression strain improved yield to 0.22 C-mol 3-HP C-mol -1 glucose after deletion of the major malonate semialdehyde dehydrogenase. Further incorporation of additional β-alanine pathway genes and optimization of culture conditions (sugars, temperature, nitrogen, phosphate, trace elements) for 3-HP production from deacetylated and mechanically refined corn stover hydrolysate improved yield to 0.48 C-mol 3-HP C-mol -1 sugars and resulted in a final titer of 36.0 g/L 3-HP. The results of this study establish A. niger as a host for 3-HP production from a lignocellulosic feedstock in acidic conditions and demonstrates that 3-HP titer and yield can be improved by a broad metabolic engineering strategy involving identification and modification of genes participated in the synthesis of 3-HP and its precursors, degradation of intermediates, and transport of 3-HP across the plasma membrane.

09 BIOMASS FUELS↗

Wireless remote monitoring of critical facilities

A method, apparatus, and system are provided for monitoring environment parameters of critical facilities. A Remote Area Modular Monitoring (RAMM) apparatus is provided for monitoring environment parameters of critical facilities. The RAMM apparatus includes a battery power supply and a central processor. The RAMM apparatus includes a plurality of sensors monitoring the associated environment parameters and at least one communication module for transmitting one or more monitored environment parameters. The RAMM apparatus is powered by the battery power supply, controlled by the central processor operating a wireless sensor network (WSN) platform when the facility condition is disrupted. The RAMM apparatus includes a housing prepositioned at a strategic location, for example, where a dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance.

99 GENERAL AND MISCELLANEOUS↗

Effects of Selenium on Mercury Bioaccumulation in a Terrestrial food Chain from an Abandoned Mercury Mining Region

Few reports of the relationship exist between mercury (Hg) and selenium (Se) from locations of severe Hg contamination in terrestrial environments. Here, we report the concentrations of Hg and Se as well as Se:Hg molar ratios in biotic samples collected from a region with a long history of Hg mining. Nitrogen isotopes (δ{sup 15}N) were analyzed to confirm the trophic levels. Results showed that bird feathers at the top trophic level exhibited the highest Hg concentrations, while the lowest concentrations were found in herbivorous insects, demonstrating a significant biomagnification across the food chain. In contrast, herbivorous insects of different types (generalists vs. specialized rice pests) exhibited both the highest and the lowest concentrations of Se, indicating a lack of biomagnification. Indeed, Se was correlated positively with Hg when Se:Hg ratios were greater than one, suggesting Se:Hg molar ratios can be a controlling influence on Hg in terrestrial organisms.

54 ENVIRONMENTAL SCIENCES↗

Cadmium exposure inhibits MMP2 and MMP9 activities in the prostate and testis

Matrix metalloproteinases (MMPs) are zinc (Zn{sup 2+}) and calcium (Ca{sup 2+}) dependant endopeptidases, capable of degradation of numerous components of the extracellular matrix. Cadmium (Cd{sup 2+}) is a well known environmental contaminant which could impair the activity of MMPs. In this sense, this study was conducted to evaluate if Cd{sup 2+} intake inhibits these endopeptidases activities at the rat prostate and testicles and if it directly inhibits the activity of MMP2 and MMP9 at gelatinolytic assays when present in the incubation buffer. To investigate this hypothesis, Wistar rats (5 weeks old), were given tap water (untreated, n = 9), or 15 ppm CdCl{sub 2} diluted in drinking water, during 10 weeks (n = 9) and 20 weeks (n = 9). The animals were euthanized and their ventral prostate, dorsal prostate, and testicles were removed. These tissue samples were processed for protein extraction and subjected to gelatin zymography evaluation. Additionally, we performed an experiment of gelatin zymography in which 5 μM or 2 mM cadmium chloride (CdCl{sub 2}) was directly dissolved at the incubation buffer, using the prostatic tissue samples from untreated animals that exhibited the highest MMP2 and MMP9 activities in the previous experiment. We have found that CdCl{sub 2} intake in the drinking water led to the inhibition of 35% and 30% of MMP2 and MMP9 (p < 0.05) at the ventral prostate and testis, respectively, in Cd{sup 2+} treated animals when compared to controls. Moreover, the activities of the referred enzymes were 80% and 100% inhibited by 5 μM and 2 mM of CdCl{sub 2}, respectively, even in the presence of 10 mM of CaCl{sub 2} within the incubation buffer solution. These important findings demonstrate that environmental cadmium contamination may deregulate the natural balance in the extracellular matrix turnover, through MMPs downregulation, which could contribute to the toxic effects observed in prostatic and testicular tissue after its exposure. - Highlights: • Wistar rats were given tap water or 15 ppm CdCl{sub 2} diluted in drinking water. • Ventral prostate, dorsal prostate, and testicles were tested for MMPs activity. • CdCl{sub 2} was also directly dissolved at the incubation buffer in another experiment. • Cadmium inhibited the activity of MMP2 and MMP9 in both experiments. • Cadmium contamination may deregulate the natural balance in the ECM turnover.

60 APPLIED LIFE SCIENCES↗

Kinetics of Cd Release from Some Contaminated Calcareous Soils

Contamination of soils with heavy metals may pose long-term risk to groundwater quality leading to health implications. Bioavailability of heavy metals, like cadmium (Cd) is strongly affected by sorption and desorption processes. The release of heavy metals from contaminated soils is a major contamination risks to natural waters. The release of Cd from contaminated soils is strongly influenced by its mobility and bioavailability. In this study, the kinetics of Cd desorption from ten samples of contaminated calcareous soils, with widely varying physicochemical properties, were studied using 0.01 M EDTA extraction. The median percentage of Cd released was about 27.7% of the total extractable Cd in the soils. The release of Cd was characterized by an initial fast release rate (of labile fractions) followed by a slower release rate (of less labile fractions) and a model of two first-order reactions adequately describes the observed release of Cd from the studied soil samples. There was positive correlation between the amount of Cd released at first phase of release and Cd in exchangeable fraction, indicating that this fraction of Cd is the main fraction controlling the Cd in the kinetic experiments. There was strongly negative correlation between the amount of Cd released at first and second phases of release and residual fraction, suggesting that this fraction did not contribute in Cd release in the kinetic experiments. The results can be used to provide information for evaluation of Cd potential toxicity and ecological risk from contaminated calcareous soils.

54 ENVIRONMENTAL SCIENCES↗

Novel Platform for Digitization of Radiation Measurements, Decommissioning and Dismantling and Nuclear Waste Management - 18229

An innovative Platform for a seamless digitization of the information produced during the characterization of radioactive waste, contaminated objects, and in general radioprotection measurements has ben developed by CAEN SyS. The Platform is based on a spectroscopic handheld instrument integrating RFID technology, barcode reader, camera, voice recorder, and geo-localization, a selection of radiation tolerant RFID tags tested above 300 Gy integrated dose, ruggedized portable RFID readers and a secure database framework capable to collect data also from external sources such as gamma scanners and imaging systems. The Platform allows for real-time measurement of dose rate, radiation spectroscopy, tagging, tracking and inventorying of items. All data produced by the Platform are securely stored into the non-volatile memory of the RFID tags and in the database for both onsite and remote access to the information by operators. This paper presents the current development of the Platform and shows the advantages of such approach to achieve an easy yet reliable waste traceability, waste bagging optimization, and a structured methodology for radiation measurements, meeting an excellent quality control as increasingly required by Safety Authorities. Applications here envisaged and explored are dismantling and decontamination operations, radioprotection measurements and patrols, nuclear material management, safeguards and verification inspections. More in general, the Platform can address the needs of all plants, research laboratories and facilities that are looking to improve their Safety Standards, decrease operational costs, have a precise knowledge of the contaminated environment and objects as well as optimization for personnel dose minimization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of a gas–liquid plasma reactor for water treatment applications: Design guidelines and electrical circuit considerations

To provide insights into the design, optimization, and scale up of plasma reactors for water treatment, the influences of discharge energy, grounded electrode size and position, and number of high voltage (HV) discharge points on the production of reactive species and the degradation of 1,4-dioxane and perfluorooctanoic acid in a gas–liquid electrical discharge plasma reactor were assessed. Discharge energy and plasma area largely control the treatment effectiveness. Increasing the number of discharge points lowers the voltage in the reactor and consequently the production rates of reactive species. Finally, bench-scale findings apply directly to large volume systems, resulting in the highest contaminant removal rates using a single HV electrode and a grounded electrode spanning the entirety of the treatment zone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Safety of Sealed Radioactive Sources

Sealed radioactive sources are used in a wide variety of occupational settings and under differing regulatory/licensing structures. The definition of a sealed radioactive source varies between US regulatory authorities and standard-setting organizations. Potential problems with sealed sources cover a range of risks and impacts. The loss of control of high activity sealed sources can result in very high or even fatal doses to members of the public who come in contact with them. Sources that are not adequately sealed, and that fail, can cause spread of contamination and potential intake of radioactive material. There is also the possibility that sealed sources may be (or threatened to be) used for terrorist purposes and disruptive opportunities. Until fairly recently, generally-licensed sealed sources and devices received little, if any, regulatory oversight, and were often forgotten, lost or unaccounted for. Nonetheless, generally licensed devices can contain fairly significant quantities of radioactive material and there is some potential for exposure if a device is treated in a way that it was never designed. Industrial radiographers use and handle high activity and/or high-dose rate sealed sources in the field with a high degree of independence and minimal regulatory oversight. Failure to follow operational procedures and properly handle radiography sources can and has resulted in serious injuries and death. Industrial radiographers have experienced a disproportionately large fraction of incidents that result in unintended exposure to radiation. Sources do not have to contain significant quantities of radioactive material to cause problems in the event of their failure. A loss of integrity can cause the spread of contamination and potential exposure to workers and members of the public. The NCRP has previously provided recommendations on select aspects of sealed source programs. Future efforts to provide recommendations for sealed source programs are discussed.

radioactive material↗

A Vector Sensor-Based Acoustic Characterization System for Marine Renewable Energy

NoiseSpotter is a passive acoustic monitoring system that characterizes, classifies, and geo-locates anthropogenic and natural sounds in near real time. It was developed with the primary goal of supporting the evaluation of potential acoustic effects of offshore renewable energy projects. The system consists of a compact array of three acoustic vector sensors, which measures acoustic pressure and the three-dimensional particle velocity vector associated with the propagation of an acoustic wave, thereby inherently providing bearing information to an underwater source of sound. By utilizing an array of three vector sensors, the application of beamforming techniques can provide sound source localization, allowing for characterization of the acoustic signature of specific underwater acoustic sources. Here, performance characteristics of the system are presented, using data from controlled acoustic transmissions in a quiet environment and ambient noise measurements in an energetic tidal channel in the presence of non-acoustic flow noise. Data quality is demonstrated by the ability to reduce non-acoustic flow noise contamination, while system utility is shown by the ability to characterize and localize sources of sound in the underwater environment.

16 TIDAL AND WAVE POWER↗