X-ray photoelectron spectroscopy of piperidinium ionic liquids: a comparison to the charge delocalised pyridinium analogues

In this study, nine piperidinium-based ionic liquids are analysed by X-ray photoelectron spectroscopy. The effect of alkyl substituent length and the nature of the anion on the electronic environment of the cation are investigated. The electronic environment of the hetero carbon and the cationic nitrogen is compared between two structurally similar cations, 1-octyl-1-methylpiperidinium ([C 8 C 1 Pip] + ) versus 1-octylpyridinium ([C 8 Py] + ). Due to the charge delocalisation, the hetero carbon component within [C 8 Py] + is more positively charged, which exhibits much higher binding energy; whilst the cationic nitrogen component is in the similar electronic environment. The impact of the charge delocalisation on the electronic environment of the anion is also compared between [C 8 C 1 Pip] + and [C 8 Py] + . Here, it is found that for the more basic anion, the cation can significantly affect the electronic environment of the anion; for the less basic anion, such an effect concentrates on the component bearing more negative point charges.

36 MATERIALS SCIENCE↗

Sulfur Kβ X-ray emission spectroscopy: comparison with sulfur K-edge X-ray absorption spectroscopy for speciation of organosulfur compounds

Until recently, sulfur was known as a “spectroscopically silent” element because of a paucity of convenient spectroscopic probes suitable for in situ chemical speciation. In recent years the technique of sulfur K-edge X-ray absorption spectroscopy (XAS) has been used extensively in sulfur speciation in a variety of different fields. With an initial focus on reduced forms of organic sulfur, we have explored a complementary X-ray based spectroscopy – sulfur Kβ X-ray emission spectroscopy (XES) – as a potential analytical tool for sulfur speciation in complex samples. In this work, we compare and contrast the sensitivity of sulfur Kβ XES with that of sulfur K-edge XAS, and find differing sensitivities for the two techniques. In some cases an approach involving both sulfur K-edge XAS and sulfur Kβ XES may be a powerful combination for deducing sulfur speciation in samples containing complex mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of machine learning techniques to optimize the analysis of plutonium surrogate material via a portable LIBS device

The utilization of machine learning techniques has become commonplace in the analysis of optical emission spectra. These methods are often limited to variants of principal components analysis (PCA), partial-least squares (PLS), and artificial neural networks (ANNs). A plethora of other techniques exist and are well established in the world of data science, yet are seldom investigated for their use in spectroscopic problems. In this study, machine learning techniques were used to analyze optical emission spectra of laser-induced plasma from ceria pellets doped with silicon in order to predict silicon content. Additionally, a boosted regression ensemble model was created, and its predictive accuracy was compared to that of traditional PCA, PLS, and ANN regression models. Boosted regression tree ensembles yielded fits with R-squared (R2) values as high as 0.964 and mean-squared errors of prediction (MSEPs) as low as 0.074, providing the most accurate predictive model. Neural networks performed with slightly lower R2 values and higher MSEPs compared to the ensemble methods, thus indicating susceptibility to overfitting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optoelectronic property comparison for isostructural Cu 2 BaGeSe 4 and Cu 2 BaSnS 4 solar absorbers

To target mitigation of anti-site defect formation in Cu 2 ZnSnS 4–x Se x , a new class of chalcogenides, for which Ba or Sr (group 2) replace Zn (group 12), has recently been introduced for prospective solar absorber application. Cu 2 BaGeSe 4 (CBGSe) and Cu 2 BaSnS 4 (CBTS) are two such compounds, which share a common trigonal crystal structure (P3 1 space group) and similar quasi-direct band gap (~2 eV). While CBTS-based films have already been studied, there are no reports yet on films and solar cells based on related CBGSe. To identify key differences and similarities in the electronic properties between these two materials, electronic characteristics (e.g., carrier concentration, mobility, electron affinity, defect levels, recombination, and charge carrier kinetics) of vacuum-deposited CBGSe and CBTS films are compared using a variety of characterization methods. Hall effect measurements reveal that CBGSe films have relatively higher hole carrier concentration and lower mobility (3 × 10 15 cm –3 , 0.6 cm 2 V –1 s –1 ) compared to CBTS (5 × 10 12 cm –3 , 3.5 cm 2 V –1 s –1 ). Photoelectron spectroscopy yields low electron affinity values for both CBGSe (3.7 eV) and CBTS (3.3 eV), pointing to the necessity of pursuing low electron affinity buffer materials for both types of absorbers. At low temperatures, CBGSe films show free-exciton photoluminescence, as well as pronounced deep-level emission at ~1.4 eV, while CBTS films exhibit a strong bound-exciton signal with noticeably less intense deep-level emission than for CBGSe. Charge carrier kinetics, transport, and recombination properties of both types of films are also analyzed using optical-pump terahertz-probe spectroscopy and time-resolved microwave conductivity. The first CBGSe prototype solar cells (using chemical bath deposited CdS as a buffer layer) show a maximum of 1.5% efficiency with ~0.62 V open-circuit voltage. Furthermore, the measured properties point to possible limiting factors for CBGSe and related films for PV and optoelectronics and provide insights on possible approaches for improvement within this multinary chalcogenide family.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A critical comparison of CH∙∙∙π versus π∙∙∙π interactions in the benzene dimer: obtaining benchmarks at the CCSD(T) level and assessing the accuracy of lower scaling methods

In this study, we have established CCSD(T)/CBS (Complete Basis Set) limits for 3 stationary points on the benzene dimer potential energy surface, corresponding to the π∙∙∙π (parallel displaced or PD(C 2h ), minimum) and CH∙∙∙π (T-shaped or T(C 2v ), transition state) and tilted T-shaped (or TT(Cs), minimum) bonding scenarios considering both the structure and binding energy. The CCSD(T)/CBS binding energies are -2.65 ± 0.02 (PD), -2.74 ± 0.03 (T), and -2.83 ± 0.01 kcal mol -1 (TT). To this end, the CH∙∙∙π is ~0.2 kcal mol -1 stronger than the π∙∙∙π interaction, whereas the tilting of the CH donating benzene molecule with respect to the other benzene is worth 0.1 kcal mol -1 . As previously discussed in the literature, the MP2 level of theory does not provide a close match for either the energy or structure, yet the SCS-MP2 yields structures in excellent agreement with respect to the CCSD(T) result. It is found that the SCS-MI-MP2 also gives optimized structures very close to SCS-MP2 (within ~0.01 Å of the benchmark). Despite the closer match in structure, the spin-biased MP2 methods (SCS-, SCS-MI-, and SOS-MP2) incorrectly predict the relative stabilities of the isomers. That said, none of the spin biased MP2 methods offers a good compromise between energy and structure for the systems examined. Finally, the CCSD(T)/CBS benchmarks were used to assess the performance of 13 DFT functionals selected from different rungs of Jacob's ladder. Several functionals such as TPSS-D3, B3LYP-D3, B97-D, B97-D3, and B2PLYP-D3 provided a good description of the binding energies for both CH∙∙∙π and π∙∙∙π interactions, yielding values within 6% of the CCSD(T)/CBS benchmark values. Unlike the MP2 methods, these functionals correctly predict the relative stability of the PD(C 2h ) and T(C 2v ) dimers. Further, we find that there is no systematic improvement as Jacob's ladder is ascended (increased complexity of functional). The best functionals that result in a good compromise between structure and energy accuracy are B97-D3 and B2PLYP-D3 for both the CH∙∙∙π and π∙∙∙π interaction. Despite the impressive performance of these functionals, a challenge that remains is ensuring the transferability of these density functionals in accurately describing the interaction between dimers of larger aromatic molecules, the latter requiring high-level benchmarks for these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

One-bond 13 C– 13 C spin-coupling constants in saccharides: a comparison of experimental and calculated values by density functional theory using solid-state 13 C NMR and X-ray crystallography

Methyl aldohexopyranosides were 13 C-labeled at contiguous carbons, crystallized, and studied by single-crystal X-ray crystallography and solid-state 13 C nuclear magnetic resonance (NMR) spectroscopy to examine the degree to which density functional theory (DFT) can calculate one-bond 13C–13C spin-coupling constants ( 1 J CC ) in saccharides with sufficient accuracy to permit their use in MA'AT analysis, a newly-reported hybrid DFT/NMR method that provides probability distributions of molecular torsion angles in solution (Zhang et al., J. Phys. Chem. B, 2017, 121, 3042–3058; Meredith et al., J. Chem. Inf. Model., 2022, 62, 3135–3141). Experimental 1 J CC values in crystalline samples of the doubly 13 C-labeled compounds were measured by solid-state 13 C NMR and compared to those calculated from five different DFT models: (1) 1 J CC values calculated from single structures identical to those observed in crystalline samples by X-ray crystallography (all atom refinement); (2) 1 J CC values calculated from the single structures in (1) but after Hirshfeld atom refinement (HAR); (3) 1 J CC values calculated from the single structures in (1) after DFT-optimization of hydrogen atoms only; and (4 and 5) 1 J CC values calculated in rotamers of torsion angle θ 2 (C1–C2–O2–O2H) or ω(C4–C5–C6–O6) from which either specific or generalized parameterized equations were obtained and used to calculate 1 J CC values in the specific θ 2 or ω rotamers observed in crystalline samples. Good qualitative agreement was observed between calculated 1 J CC values and those measured by solid-state 13 C NMR regardless of the DFT model, but in no cases were calculated 1 J CC values quantitative, differing (over-estimated) on average by 4–5% from experimental values. These findings, and those reported recently from solution NMR studies (Tetrault et al., J. Phys. Chem. B 2022, 126, 9506–9515), indicate that improvements in DFT calculations are needed before calculated 1 J CC values can be used directly as reliable constraints in MA'AT analyses of saccharides in solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The highly exothermic hydrogen abstraction reaction H 2 Te + OH → H 2 O + TeH: comparison with analogous reactions for H 2 Se and H 2 S

The “gold standard” CCSD(T) method is adopted along with the correlation consistent basis sets up to aug-cc-pV5Z-PP to study the mechanism of the hydrogen abstraction reaction H 2 Te + OH. Here, the predicted geometries and vibrational frequencies for reactants and products are in good agreement with the available experimental results. With the ZPVE corrections, the transition state in the favorable pathway of this reaction energetically lies 1.2 kcal mol -1 below the reactants, which is lower than the analogous relative energies for the H 2 Se + OH reaction (-0.7 kcal mol -1 ), the H 2 S + OH reaction (+0.8 kcal mol -1 ) and the H 2 O + OH reaction (+9.0 kcal mol -1 ). Accordingly, the exothermic reaction energies for these related reactions are predicted to be 47.8 (H 2 Te), 37.7 (H 2 Se), 27.1 (H 2 S), and 0.0 (H 2 O) kcal mol -1 , respectively. Geometrically, the low-lying reactant complexes for H 2 Te + OH and H 2 Se + OH are two-center three-electron hemibonded structures, whereas those for H 2 S + OH and H 2 O + OH are hydrogen-bonded. With ZPVE and spin–orbit coupling corrections, the relative energies for the reactant complex, transition state, product complex, and the products for the H 2 Te + OH reaction are estimated to be -13.1, -1.0, -52.0, and -52.6 kcal mol -1 , respectively. Finally, twenty-eight DFT functionals have been tested systematically to assess their ability in describing the potential energy surface of the H 2 Te + OH reaction. The best of these functionals for the corresponding energetics are -9.9, -1.4, -46.4, and -45.4 kcal mol -1 (MPWB1K), or -13.1, -2.4, -57.1, and -54.6 kcal mol -1 (M06-2X), respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Homogeneous versus MOF-supported catalysis: a direct comparison of catalytic hydroboration with Ni tripodal P 3 E (E = Si, Ge) complexes

The MOF material NU-1000 was employed to host Ni tripodal complexes prepared from new organometallic precursors [HNi(κ 4 (E,P,P,P)-E(o-C 6 H 4 CH 2 PPh 2 ) 3 ], E = Si (Ni-1), Ge (Ni-2). The new heterogeneous catalytic materials, Ni-1@NU-1000 and Ni-2@NU-1000, show the advantages of both homogeneous and heterogeneous catalysts. Finally, they catalyze the hydroboration of aldehydes and ketones more efficiently than the homogeneous Ni-1 and Ni-2, under aerobic conditions and show recyclability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗