Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Accelerating Noisy VQE Optimization with Gaussian Processes

Hybrid variational quantum algorithms, which combine a classical optimizer with evaluations on a quantum chip, are the most promising candidates to show quantum advantage on current noisy, intermediate-scale quantum (NISQ) devices. The classical optimizer is required to perform well in the presence of noise in the objective function evaluations, or else it becomes the weakest link in the algorithm. We introduce the use of Gaussian Processes (GP) as surrogate models to reduce the impact of noise and to provide high quality seeds to escape local minima, whether real or noise-induced. We build this as a framework on top of local optimizations, for which we choose Implicit Filtering (ImFil) in this study. ImFil is a state-of-the-art, gradient-free method, which in comparative studies has been shown to outperform on noisy VQE problems. The result is a new method: "GP+ImFil". We show that when noise is present, the GP+ImFil approach finds results closer to the true global minimum in fewer evaluations than standalone ImFil, and that it works particularly well for larger dimensional problems. Using GP to seed local searches in a multi-modal landscape shows mixed results: although it is capable of improving on ImFil standalone, it does not do so consistently and would only be preferred over other, more exhaustive, multistart methods if resources are constrained.

Muller, Juliane↗

Particle Swarm Optimization of Dynamic Load Model Parameters in Large Systems

This paper considers two dynamic load models that are widely used in industry to account for induction motor behavior: CMLD and CLOD. These models must be parametrized for the specific utility system in a general way so that they can be used in planning studies and provide a conservative but realistic representation of load behavior. This study considers a measurement-based approach to tuning both models. The load modeling study compares the response of the tuned models to generic candidate models using historical events. This study considers one area-based subsystem to simplify the modeling approach and reduce the number of models required for simulations. Additionally, because dynamic load models often produce similar results for different sets of parameters, a sensitivity study was conducted to assess the parameter impacts on the voltage response. The sensitivity study covers the parameters that are tuned using event measurements. The process to estimate the parameters uses the particle-swarm optimization algorithm. Overall, the performance of the tuned model more accurately captures recovery voltage, delayed recovery, and settling voltage than its predecessor models while not being overly tuned so that it remains general for peak summer conditions.

dynamic load modeling↗

An Alternating, Current-Induced Electromagnetic Field for Membrane Fouling and Scaling Control during Desalination of Secondary Effluent from Municipal Wastewater

Membrane treatment of secondary effluent for reuse applications is a promising approach to expand water supplies and provide flexibility to water resources management. However, effective control of membrane fouling and scaling is crucial for cost-effective treatment and system resilience. This study compared the performance of antiscalants to an alternating, current-induced electromagnetic field (EMF) as an alternative pretreatment method to reverse osmosis. Compared to the no-EMF control experiments, the EMF device resulted in 13% higher water recovery and 366% lower flux decline at 60% of water recovery, along with 2–8 times lower precipitation of fouling and scaling, as evidenced by scanning electron microscope, energy dispersive X-ray spectroscopy, and chemical extraction analysis. The combination of the EMF with antiscalant was more effective for reducing membrane fouling and scaling, increasing water recoveries up to 89.3%, as compared to the EMF (67.5%) and antiscalant-only (73.6%) configurations. This is the first study to demonstrate synergistic effects of using an EMF in combination with antiscalants and could lead to lower pretreatment costs. Additional research is required to quantify the economics of this approach and to fully understand the fundamental mechanisms governing fouling and scaling control by an EMF.

42 ENGINEERING↗

Partitioning Stakeholders for the Economic Valuation of Ecosystem Services: Examples of a Mangrove System

Although the importance of ecosystem services provided by natural forests, especially mangroves, is well known, the destruction of these environments is still ubiquitous and therefore protection measures are urgently needed. The present study compares the current approach of economic valuation of ecosystem services to a proposed one, using a study case of a mangrove system as an example. We suggest that a cost-benefit analysis for economically valuing environmental services should be performed with three additional modifications consisting of (i) a categorization of local stakeholders as demanders of particular ecosystem services, (ii) acknowledgement of the government as one of these demander groups, and (iii) the inclusion of opportunity costs in the valuation. The application of this approach to the mangrove area in the east portion of Great Abaco Island, the Bahamas, reveals that not only the ecosystem services received differ between demander groups, but the monetary benefits and costs are also specific to each of these groups. We show that the economic valuation of the ecosystem should be differentiated for each category, instead of being calculated as a net ‘societal value’ as it is currently. Applying this categorization of demanders enables a better understanding of the cost and benefit structure of the protection of a natural area. The present paper aims to facilitate discussions regarding benefit and cost sharing related to the protection of natural areas.

54 ENVIRONMENTAL SCIENCES↗

Couch height–based patient setup for abdominal radiation therapy

There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on the computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.

61 RADIATION PROTECTION AND DOSIMETRY↗

Curcumin differentially affects cell cycle and cell death in acute and chronic myeloid leukemia cells

Curcumin is a phytochemical with potent antineoplastic properties. The antitumoral effects of curcumin in cells derived from chronic or acute myeloid leukemia have been already described. However, a comparative study of the cytostatic and cytotoxic effects of curcumin on chronic and acute myeloid leukemia cells has not yet been performed. In the present study, the cellular effects of curcumin on cell lines derived from chronic or acute myeloid leukemia were examined. Dose and time-response assays were performed with curcumin on HL-60 and K562 cells. Cell viability was evaluated with trypan blue exclusion test and cell death by flow cytometry using a fluorescent molecular probe. Additionally, a cell cycle profile was analyzed, and protein markers of cell cycle progression and cell death were investigated. In the present study, the K562 cells showed a higher sensitivity to the cytostatic and cytotoxic effects of curcumin compared with HL-60. In addition, curcumin induced G1 phase arrest in HL-60 cells and G2/M phase arrest in K562 cells. Furthermore, curcumin-related cell death in HL-60 was associated with the processed forms of caspases-9 and -3 proteins, whereas in K562 cells, both the processed and the unprocessed forms were present. Accordingly, activity of these caspases was significantly higher in HL-60 cells compared with that in K562. In conclusion, curcumin elicits different cellular mechanisms in chronic or acute myeloid leukemia cells and the powerful antitumoral effect was more potent in K562 compared with HL-60 cells.

60 APPLIED LIFE SCIENCES↗

A benchmark study of electronic excitation energies, transition moments, and excited-state energy gradients on the nicotine molecule

In this work, we report a comparative study of computed excitation energies, oscillator strengths, and excited-state energy gradients of (S)-nicotine, chosen as a test case, using multireference methods, coupled cluster singles and doubles, and methods based on time-dependent density functional theory. This system was chosen because its apparent simplicity hides a complex electronic structure, as several different types of valence excitations are possible, including n-π{sup *}, π-π{sup *}, and charge-transfer states, and in order to simulate its spectrum it is necessary to describe all of them consistently well by the chosen method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation Of Four Welding Arc Processes Applied To 6061 Aluminium Alloy

At a time when greenhouse gas emissions must be reduced, the use of the aluminium alloys is expanding, in particular in the transportation industry. In order to extend the possibilities of aluminium assembly design, new Metal Inert Gas (MIG) welding processes have been conceived. They work at lower temperatures than usual arc processes (classic MIG or Tungsten Inert Gas). This study compares four arc welding processes, applied to the 6061 aluminium alloy. These four weld processes have been studied through the metallurgical analysis of the weld beads. Metallography, micro-hardness testings, X Ray radiography have been carried out on the produced weld beads. The processes are classified according to the quality of the beads like geometry of beads, size of the heat affected zone and presence of defects.

36 MATERIALS SCIENCE↗

Recurrent prostate cancer after radical prostatectomy: restaging performance of 18F-choline hybrid PET/MRI

To evaluate the diagnostic performance of a whole-body 18F-choline (FCH) hybrid PET/MRI for prostate cancer patients at biochemical relapse after radical prostatectomy (RP) compared to pelvic multiparametric MRI (mpMRI), one of the standard imaging modality for this patient population. From 2010 to 2016, 58 whole-body FCH PET/MRI studies with mpMRI acquisitions were performed in 53 prostate cancer patients relapsing after curative RP. Median PSA and PSA doubling time (PSA DT) at PET study were 1.5 ng/ml and 6.5 months, respectively. The overall positivity rate of FCH PET/MRI was 58.6% (n = 34), dropping to 44% in patients with a PSA ≤ 2 ng/ml (n = 36). Median PSA values in positive and negative PET/MRI studies were 2.2 ng/ml and 0.8 ng/ml, respectively, with no differences in PSA DT (6.5 vs. 6.6 months). A PSA value ≥ 1.5 ng/ml was a significant predictor of positivity on PET/MRI studies. Compared to PET, mpMRI identified more local relapses (17 vs. 14, p = 0.453) while PET outperformed whole-body Dixon MRI for regional (16 vs. 9, p = 0.016) and distant (12 vs. 6, p = 0.031) metastases. Compared to pelvic mpMRI, the treatment approach turned out to be influenced more frequently using whole-body FCH hybrid PET/MRI studies (58.6% vs. 38%). In prostate cancer patients with biochemical recurrence after RP, whole-body FCH PET/MRI achieved a higher detection rate of nodal/distant metastases compared to pelvic mpMRI alone, increasing the change of treatment strategy by more than 20%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardized verification of the C YCLUS fuel cycle simulator

Many nuclear fuel cycle simulators can analyze transitions from once-through to advanced nuclear fuel cycles. Verification studies compare various fuel cycle analysis tools to test agreement and identify sources of difference. A recent verification study, Feng et al. (2016) established transition scenario test case specifications and accordingly evaluated national laboratory nuclear fuel cycle simulators, DYMOND, VISION, ORION, and MARKAL. This work verifies the performance of C YCLUS , the agent-based, open-source fuel cycle simulator, using the test case specifications in Feng et. al. We report, C YCLUS demonstrates agreement with the results from the previous verification study. Minor differences reflect intentional, detailed material tracking in the C YCAMORE reactor module. These results extend the example results in Feng et al. to further enable future verification of additional nuclear fuel cycle simulation tools.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of hydrogenation on magnetic and electronic behaviour of Pr-Ni

Magnetic and electronic properties of PrNi and PrNi-H have been investigated by using first principles approach. The ground state of both the compounds is base-centered orthorhombic CrB structure. Calculations are performed using full potential linearized augmented plane wave plus local orbitals (FP-L/APW) method including spin-polarization within the frame work of density functional theory (DFT). The electronic exchange-correlation energy is described by generalized gradient approximation (GGA). The hydrogen stored in PrNi, i.e., PrNi-H has been studied to analyze the effective changes in magnetic moments and electronic structures in comparison to PrNi. A comparative study of the density of states in both the compounds has also been presented.

36 MATERIALS SCIENCE↗

A Comparison of Different NDE Signal Processing Techniques Based on Waveform Entropies Applied to Long Fiber Graphite/Epoxy Plates

This study compares different approaches for imaging the internal architecture of graphite/epoxy composites using backscattered ultrasound. Two cases are studied. In the first, near-surface defects in a thin graphite/epoxy plates are imaged. The same backscattered waveforms were used to produce peak-to-peak, logarithm of signal energy, as well as entropy images of different types. All of the entropy images exhibit better border delineation and defect contrast than the either peak-to-peak or logarithm of signal energy. The best results are obtained using the joint entropy of the backscattered waveforms with a reference function. Two different references are examined. The first is a reflection of the insonifying pulse from a stainless steel reflector. The second is an approximate optimum obtained from an iterative parametric search. The joint entropy images produced using this reference exhibit three times the contrast obtained in previous studies. These plates were later destructively analyzed to determine size and location of near-surface defects and the results found to agree with the defect location and shape as indicated by the entropy images. In the second study, images of long carbon graphite fibers (50% by weight) in polypropylene thermoplastic are obtained as a first step toward ultrasonic determination of the distributions of fiber position and orientation.

Entropy Imaging↗

Comparative Analysis and Considerations for PV Interconnection Standards in the United States and China

The main objectives of this report are to evaluate China's photovoltaic (PV) interconnection standards and the U.S. counterparts and to propose recommendations for future revisions to these standards. This report references the 2013 report Comparative Study of Standards for Grid-Connected PV System in China, the U.S. and European Countries, which compares U.S., European, and China's PV grid interconnection standards; reviews various metrics for the characterization of distribution network with PV; and suggests modifications to China's PV interconnection standards and requirements. The recommendations are accompanied by assessments of four high-penetration PV grid interconnection cases in the United States to illustrate solutions implemented to resolve issues encountered at different sites. PV penetration in China and in the United States has significantly increased during the past several years, presenting comparable challenges depending on the conditions of the grid at the point of interconnection; solutions are generally unique to each interconnected PV installation or PV plant.

14 SOLAR ENERGY↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of epitaxial lateral overgrowth of semipolar (1 1 − 2 2) GaN by using different SiO{sub 2} pattern sizes

Graphical abstract: - Highlights: • We examine comparative studies of semipolar ELO-GaN film. • Semipolar ELO-GaN film was grown by three step growth method. • The achievement of smooth surface morphology of semipolar ELO-GaN. • The crystal and optical properties was significantly improved by ELO process. - Abstract: We investigated the growth mode and the crystal properties of lateral epitaxial overgrowth (LEO) semipolar (1 1 − 2 2) GaN by using the various SiO{sub 2} pattern sizes of 6, 8, 10 and 12 μm with the window width of 4.0 μm. By using three-step growth technique, we successfully obtained the fully-coalescenced semipolar (1 1 − 2 2) LEO-GaN films regardless of the SiO{sub 2} pattern sizes. However, the coalescence thickness of LEO-GaN film was decreased with decreasing SiO{sub 2} pattern size, indicating that the coalescence of semipolar (1 1 − 2 2) GaN was easily formed by decreasing the pattern size of SiO{sub 2} mask. The full width at half maximums (FWHMs) of X-ray rocking curves (XRCs) of LEO-GaN films decreased with increasing SiO{sub 2} pattern size. In the pattern size of 4 × 10 μm, we achieved the minimum XRCs FWHM of 537 and 368 arc s with two different X-ray incident beam directions of [1 1 − 2 − 3] and [1 − 1 0 0], respectively. Moreover, the photoluminescence bandedge emission of semipolar (1 1 − 2 2) GaN was 45 times increased by LEO process. Based on these results, we concluded that the LEO pattern size of 4 × 10 μm would effectively decrease crystal defects of semipolar (1 1 − 2 2) GaN epilayer, resulting in an improvement of the optical properties.

36 MATERIALS SCIENCE↗

First principles study on electronic structure and elastic properties of LaCd and LaHg

Full -potential linearized augmented plane wave method (FP- LAPW) has been used for the comparative study of electronic structure and elastic properties of CsCl-type LaCd and LaHg intermetallic compounds using generalized gradient approximation (GGA). The density of states at the Fermi Level, N (E{sub F}), is found to be 0.06 and 3.03 states/eV for LaCd and LaHg respectively. We report elastic constants for these compounds for the first time. The ductility/brittleness of these compounds has been analyzed using Pugh rule and Cauchy’s pressure.

36 MATERIALS SCIENCE↗

SU-E-T-372: Dosimetric Comparison of Craniospinal Irradiation Using Different Tomotherapy Techniques

Purpose: TomoHDA can treat with fixed jaws, dynamic jaws, and fixed gantry using either 3DCRT or IMRT. This study compares PTV coverage, OAR sparing, and beam-on-time (BOT) among these techniques for craniospinal irradiation (CSI). Methods: This study includes ten CSI patients treated to 23.4 Gy/13 fractions with Hi-Art 3.0 unit (HT-IMRT fixed 5 cm jaw). New plans were regenerated with 5 cm jaw for TomoHDA Hi-Art 5.0 using dynamic jaw (HD-IMRT), TomoDirect-IMRT (TD-IMRT), and Helical Tomotherapy 3DCRT (HT-3DCRT using 5 cm and 2.5 cm jaws with various pitches). Studied parameters include PTV mean dose, D95 (dose covering 95% of PTV), Paddick's conformity index (CI) and homogeneity index (HI – standard deviation of PTV dose/average PTV dose), BOT, and average OAR doses. Results: PTV coverage from these techniques were comparable (p>0.05). The main differences were in OAR sparing; HDIMRT reduced more OAR doses for lenses, bladder and rectum compared to HT-IMRT. For the sparing of visceral organs: liver, lung, heart, and kidneys, the three IMRT techniques gave comparable results. HD-IMRT gave best heart sparing; HT-IMRT best kidney sparing. Liver and lung doses were best reduced by TD-IMRT. All three IMRT techniques gave comparable BOT. OARs sparing was achieved for jaw size of 2.5 cm. HI was also improved but with doubling of BOT. Increasing the pitch number from 0.2 to 0.43 produced no significant improvement in OAR sparing but CI and HI did improve. Conclusion: HT-3DCRT, HT-IMRT, HD-IMRT or TD-IMRT techniques give comparable PTV coverage but the three IMRT plans better spared OARs compared with 3DCRT plans. Dynamic jaw plan is superior to fixed jaw plan to spare more OAR doses at field edge. TD-IMRT cannot reduce BOT for CSI patient but for sparing certain OAR, TD-IMRT may be used to avoid the beam going through the structures of interest.

60 APPLIED LIFE SCIENCES↗

Determination of the amount of reacted metakaolin in calcined clay blends

This paper presents a comparative study of three methods to determine the amount of reacted metakaolin in calcined clay blends: mass balance, thermodynamic modelling, and the Partial or not Known Crystalline Structure method (PONKCS) based on Rietveld analysis of X-ray diffraction. The methods are applied to Limestone calcined clay cements (LC{sup 3}-50) in this study. Mass balance and thermodynamic modelling results show good agreement, especially at early age. PONKCS method shows globally comparable results, even if it has higher variability. The precision of PONKCS becomes poor for blends with <60% of metakaolin in calcined clay.

36 MATERIALS SCIENCE↗