Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

Field quality of the 4.5 m-long MQXFA pre-series magnets for the HL-LHC Upgrade as observed during magnet assembly

We report that the U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is developing MQXFA magnets, a series of 4.5 m long 150 mm aperture high-field Nb 3 Sn quadrupole magnets for the HL-LHC upgrade at CERN. Five pre-series magnets, MQXFA03 through MQXFA07, have been developed. During the magnet assembly stage, we perform magnetic measurements on the coil-pack sub-assembly and magnets after loading to track the field quality for two purposes. First, it serves as a quality assurance tool to check if the magnetic field quality is on track to meet the acceptance criteria. Magnetic measurements are used to understand if magnetic shims are needed to compensate low-order field errors and to meet the field quality targets. Second, the measurements during the assembly stage can also help understand the field quality, especially the geometric field errors, for Nb 3 Sn accelerator magnets. Here we summarize the measurement results of the pre-series MQXFA magnets, including the magnetic axis and twist angle. The results will provide useful feedback for the series production of Nb 3 Sn magnets and on the optimization of field quality of accelerator magnets based on the wind-and-react Nb 3 Sn technology.

43 PARTICLE ACCELERATORS↗

Mechanical and Thermal Analysis of an HTS Superconducting Magnet for an Achromatic Gantry for Proton Therapy

The mechanical and thermal analysis of the superconducting magnets, forming an innovative fixed-field bending section for use in a proton therapy gantry, is presented here. In this work, the design concept has a large momentum acceptance, covering the full proton energy range of 70 to 220 MeV with fixed field in the superconducting magnets, and uses a simple magnet geometry based on double-pancake high temperature superconductor coils. The main planned steps for the assembly and fabrication of the magnets are discussed. The mechanical analyses of the magnet, with emphasis on the stress state of the conductor during the powering of the magnet, is here described. The thermal analysis investigating the adequacy of the copper structure surrounding the conductor to extract the heat deposited in the conductor during powering is also discussed in detail.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flux Creep in a Bi-2212 Rutherford Cable for Particle Accelerator Applications

Bi-2212 superconducting cables are being considered for use in the high field magnets needed for the next generation of particle accelerators. Magnetization in these cables and the decay of that magnetization lead to field error and field-error drift, respectively, which need to be compensated. To study this, a segment of the winding pack was extracted from a racetrack coil made from Bi-2212 Rutherford cable. Using a Hall probe measurement technique, we measured the response of the cable's magnetization and its magnetization decay to changes in the applied magnetic field. The effect of adjustments to the cycling of the magnetic field was studied, intended to simulate the preinjection cycles of an accelerator magnet. Three M vs. H loops were constructed by sweeping the magnetic field applied to the sample from 0 to 2.5 T, then to a preinjection field 'x' (where x = 0, 0.25, 0.75 T), and finally up to 1 T. The applied field was then held at 1 T for 1500 s, and the magnetization decay was measured. Finally, the decay was found to vary from 8% to 14% after 1500 s, depending on the preinjection field cycle.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Minimum Quench Energy of Nb 3 Sn Wires With High Specific Heat Tape

A major problem of state-of-the-art Nb3Snaccelerator magnets is their long training due to thermo-mechanical perturbations. Increasing the specific heat, Cp, of the Rutherford cable would reduce and/or eliminate training by limiting the coils temperature rise. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using thin composite Cu/Gd 2 O 3 and Cu/Gd 2 O 2 S tapes produced by HyperTech Research, Inc. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. Wire samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for their Minimum Quench Energy (MQE). At 90%Ic and 15 T, the average gain of MQE of the Nb 3 Sn wire soldered to the Cu/Gd 2 O 2 S 55 μm thick ribbon was 2.5, and further increased at larger transport currents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning, Performance, and Effect of the Quench Current-Boosting Device on a Dedicated Superconducting Magnet

Superconducting magnet training is one of the accelerator related issues attracting attention due to significant operational costs and time budget associated to it. It is especially worrisome that magnets based on the “next-generation” Nb 3 Sn technology are affected by long training. While various efforts are underway to better understand and resolve the problem a parallel path could also be investigated, a path bypassing the issue. Following the concept of fast induced over-current during magnet powering, FNAL has developed an upgradable capacitor-based device to discharge through a superconducting magnet at quench detection or operator chosen time. The 0.4 F/1 kV device has been tested on a 1-m-long dipole-coil in a “mirror” magnet configuration and conclusive results on magnet training elimination have been observed. Here in this paper we discuss the main characteristics of the device, compare simulated response and actual performance, elaborate on test drivers and outcomes. Next steps and perspectives for future use are debated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of CLIQ on Training of HL-LHC Quadrupole Magnets

The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb 3 Sn magnets to be used in any large particle accelerator. At development stages, many Nb 3 Sn accelerator sub-scale models showed relatively slow training and MQXFA magnets were projected to have low tens of quenches before reaching operational field. Recently it was shown that dedicated capacitor-based de-vices can affect Nb 3 Sn magnet training, and it was suggested that CLIQ, a capacitor-based device intended for quench protection, can do too. Here, the present paper investigates effects on training likely induced by CLIQ, using the base fact that only half the coils in a quadrupole experience upward current modulation at quench because of capacitor discharge. The study encompasses all MQXFA production magnets trained at BNL to date. No other high-statistics data from identical magnets (series) with CLIQ protection exist so far. Implications and opportunities stemming from data analysis are discussed and conclusions drawn.

43 PARTICLE ACCELERATORS↗

R&D Needs for a US Fusion Magnet Base Program

Significant technology maturation efforts are underway by privately funded fusion startups with the goal to demonstrate mature HTS magnet technology. To support the private sector development effort and the DOE milestone based program, a U.S. Fusion Magnet Community Workshop was held on March 14-15, 2023 in Princeton, NJ. This was the first U.S. community workshop focused on fusion magnet technologies aimed at determining the structure and technical direction for a public program designed to complement the private fusion industry landscape. Based on the wide range of different contributions, a set of general themes and fusion magnet R&D needs were identified and discussed. Feedback received to the workshop charge questions highlighted critical magnet R&D gaps such as availability of existing large cable and coil test facilities, a magnet education program that can generate a trained and essential workforce by leveraging R&D capabilities of universities, U.S. national labs, and fusion industry. Other opportunities synergistic and complementary with high energy physics, high field magnets that are open for a broad range of science drivers. The defined R&D gaps underpin the need for a mid-term and long-term public program in fusion magnet development, which reflects the purpose of the workshop in developing the rationale and consent for such a base program. A self-consistent, fusion specific U.S. fusion magnet program will complement and de-risk fusion pilot plants (FPPs) of promising magnetic configurations developed by private companies on a timeline consistent with the NASEM report on bringing fusion to the U.S. grid. We describe the magnet challenges presented and R&D needs discussed in the workshop. In conclusion, these challenges and R&D needs provide focus for the development of U.S. mid-term and long term roadmaps on enabling HTS for high field fusion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Re-Assembly and Test of a COMB Dipole Magnet With STAR Wires

Rare-Earth Barium Copper Oxide (REBCO) coated conductors are an attractive option for application in high field accelerator magnets due to their high critical field and the convenience of fabrication without heat treatment compared to some other superconductors. A small REBCO accelerator magnet was previously fabricated and tested in liquid nitrogen, demonstrating over 90% critical current retention in the coils. This paper describes the magnet re-assembly with a different support structure and its test in liquid helium at 1.8–4.5 K. The magnet quench history along with the instrumentation data is presented and discussed.

43 PARTICLE ACCELERATORS↗

Design and Analysis of Short Period 2G-HTS Undulators

Recent advancements in second-generation high-temperature superconducting (2G-HTS) materials have opened new possibilities for superconducting undulator (SCU) technology, particularly in achieving shorter periods and higher magnetic fields. Here, this paper presents the design and analysis of a short-period, as small as 10 mm, 2G-HTS undulator, focusing on magnetic performance, mechanical force minimization, and quench protection. A force-balanced coil pack design is introduced to significantly reduce mechanical stresses on the conductors, eliminating the need for heavy support structures. Rapid prototyping techniques such as3D printing is employed to refine the design for scalability and manufacturability. Correction schemes for end-field effects are developed using a combination of 2G-HTS tapes and NbTi conductors to optimize field integrals. Simulation results demonstrated that optimized magnetic performance and enhanced mechanical stability, positioning 2G-HTS undulators as promising candidates for storage ring and free-electron based light sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Large Bore Conduction Cooled Superconducting Magnet for the Princeton Axion Search

Princeton University (PU) is designing and building a new experiment, called the Princeton Axion Search (PXS), that aims to discover (or exclude) Quantum Chromodynamics (QCD) axions in the 0.8–2 μeV mass range that are the cosmological dark matter. Core elements of the experiment are new, and in particular new to the search for axion dark matter. An essential component of the experiment is a 5 T superconducting magnet with a total bore volume of ~500 L. The Princeton Plasma Physics Laboratory (PPPL), a Department of Energy (DOE) Laboratory managed by Princeton University, has the unique expertise and experimental facilities to design and construct such a solenoid magnet assembled with the cavity resonator for PXS. To support this, PPPL utilizes legacy ITER-Nb3Sn conductors, along with its experimental facilities and expertises to design, build and test low-cost conduction-cooled superconducting solenoid magnets to be integrated into the axion detector. This paper discusses the various coil design and integration challenges in the large bore conduction cooled magnet in support of PXS. In conclusion, the proposed instrumental methods will help optimize the path to future and more ambitious axion searches at lower masses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Suppressing Screening-Current-Induced Strain in a 72-mm-Bore REBCO Insert for a 20-T Magnet: A Numerical Study

Rare-earth barium copper oxide (REBCO) high-temperature superconducting (HTS) magnets are considered a game changer for the capability of generating magnetic fields exceeding 20 T at or above liquid helium temperature, combined with the potential for substantially reduced manufacturing and operational costs. Princeton Plasma Physics Laboratory is dedicated to developing large-bore high-field superconducting magnet systems to support forefront physics research. Here, our current project focuses on a φ72-mm cold-bore REBCO insert comprising 21 dry-wound double-pancake coils, designed to generate at least 8 T when nested within a 12-T outsert magnet. A significant challenge for high-field REBCO magnets is the time-varying-magnetic-field-induced screening currents (SC) in the REBCO conductors, which can cause localized strain and stress concentrations. This paper presents a numerical study of the SC-induced strain in the REBCO insert magnet, confirming that the SC-induced strain can be substantially suppressed by energizing the REBCO insert before the outsert magnets. We discuss and reveal the mechanism behind this reduction. By applying this strategy, we expect to unleash the potential of the REBCO insert magnet to generate up to 12 T in a 12-T background field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Design of MARCO, the New Solenoidal Detector Magnet for the ePIC Experiment at BNL

MARCO is the new superconducting solenoid for ePIC, the general-purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider at Brookhaven National Laboratory. Here, this 3.84 m long solenoid, with a bore diameter of 2.84 m, will provide a magnetic field of 2.0 T at the center with a nominal current of 4 kA at 4.5 K, for a total stored energy of 45 MJ. Its conductor is a NbTi Rutherford in Copper Channel (RICC), specially designed to stand the high mechanical loads induced by the magnetic field. Its copper stabilizer will assure the protection in case of quench. The coils are wound into six layers inside a thin external mandrel in brass, with a triple role of mechanical reinforcement, cryogenic support for the thermosiphon circuit and quench-back propagator. With a cold mass average radial thickness of just 7 cm, the magnet fulfills all the criterions of transparency for the particles directed to the hadronic calorimeter forecast around the cryostat. In this paper, the design of MARCO is presented, with a specific focus on the magnetic and quench analysis.

Calvelli, Valerio [Commissariat a l'Energie Atomiq↗

A Two-Dimensional Non-Linear Magnetic Equivalent Circuit Model to Facilitate the Preliminary Design of a Normal Conducting Quadrupole

Normal conducting quadrupoles have been used to focus charged particle beams in synchrotrons, beam transfer lines, medical linacs, etc. for a long time. Optimization techniques based on analytical expressions combined with the use of a numerical field analysis tool exist in the literature for the design of an optimal pole tip shape. However, the initial shape and dimensions of the remaining yoke (including the pole itself and yoke base that act as the return path) are usually less well defined. This article discusses a design methodology for a normal conducting quadrupole based on a two-dimensional magnetic equivalent circuit. Here, this approach considers the geometry of the entire magnet and the non-linear behavior of the yoke material, thereby eliminating the initial iterations. The design outcome of this exercise serves as a competent starting point and can then be used to refine the pole tip, pole taper, yoke size, and add other geometrical features to achieve the required field quality, gradient, coil considerations, etc. by employing a finite element analysis tool. An example design study to demonstrate the proposed methodology is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗