Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COST PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Thermally Insulating Transparent Barrier (THINNER) coatings on single pane windows

Conventional silica aerogel monoliths can provide remarkable thermal insulation but the presence of large pores (> 30 nm) tends to scatter visible light and render the material opaque or translucent instead of transparent. In addition, they are prone to cracking during synthesis and handling which makes them difficult to integrate in products and in particular in window solutions. This project developed two new solgel synthesis methods using silica precursors or preformed silica nanoparticles and ambient drying to produce mesoporous organo-silica monoliths. The monoliths were (i) thermally insulating, (ii) optically transparent, (iii) flexible, and (iv) hydrophobic. They feature porosity ranging from 50% to 90% with narrow pore size distribution with pore less than 20 nm resulting in excellent optical clarity (haze < 2%) and very low thermal conductivity (< 30 mW/mK). Interestingly, not only porosity but also pore size and mass fractal dimension were found to affect the thermal conductivity of the mesoporous silica. The superior transparency of the monoliths was shown to be attributed to dependent scattering among silica nanoparticles. Flexibility was achieved through trimethylchlorosilane surface modification. Furthermore, process scale-up and integration of the ambigel monoliths into window solutions using optically clear adhesives were also demonstrated in 6”x6” double-pane windows. The aerogel and the window solution were shown to be durable to accelerated aging under UV, moisture, and/or temperature gradient and thermal cycling. Overall, the window solution achieved the technical performance and the cost target of $10/sqft set for the SHIELD program. However, scaling to industry relevant scale (> 10’x10’) remains a challenge due to requirements on the drying process and fume hood size and to the propensity of large aerogel slab to crack during drying.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Difficulty and Cost of Research and Development for the Case of Distributed Aviation Systems

Assessment of the difficulty and cost of research and development relating to distributed aviation systems is considered. A problem is that the participants in development projects may assess them subjectively. Analysis of the basic methods used to assess the difficulty and cost of research and development in industry and associated fields reveals their deficiencies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Searching for the Optimal Mix of Solar and Efficiency in Zero Net Energy Buildings

Zero net energy (ZNE) buildings employ efficiency to reduce energy consumption and solar technologies to produce as much energy on site as is consumed on an annual basis. Such buildings leverage utility grids and net-metering agreements to reduce solar system costs and maintenance requirements relative to off-grid photovoltaic (PV)-powered buildings with batteries. The BEopt software was developed to efficiently identify cost-optimal building designs using detailed hour-by-hour energy simulation programs to evaluate the user-selected options. A search technique identifies optimal and near-optimal building designs (based on energy-related costs) at various levels of energy savings along the path from a reference building to a ZNE design. In this paper, we describe results based on use of the BEopt software to develop cost-optimal paths to ZNE for various climates. Comparing the different cases shows optimal building design characteristics, percent energy savings and cash flows at key points along the path, including the point at which investments shift from building improvements to purchasing PV, and PV array sizes required to achieve ZNE. From optimizations using the BEopt software for a 2,000-ft{sup 2} house in 4 climates, we conclude that, relative to a code-compliant (IECC 2006) reference house, the following are achievable: (1) minimum cost point: 22 to 38% source energy savings and 15 to 24% annual cash flow savings; (2) PV start point: 40 to 49% source energy savings at 10 to 12% annual cash flow savings; (3) break-even point: 43 to 53% source energy savings at 0% annual cash flow savings; and (4) ZNE point: 100% source energy savings with 4.5 to 8.1 kW{sub DC} PV arrays and 76 to 169% increase in cash flow.

14 SOLAR ENERGY↗

Outyear Budgeting Tool

OBTool performs the following: • Consistent method and tool to develop/estimate fiscal year (FY) 2010 and outyear budget/estimates • Maintain configuration control on resource rates and changes to outyear budget estimates, while allowing for accessibility, accountability, and tracking shared access between program managers, facility managers (FMs), project managers (PMs), cost account managers (CAMs), and project controls engineers (PCEs) • Consistency in budget estimating methodology, including scope, requirements, basis of estimates, resources, activities, escalation, and presentation of documentation in tasks and execution plans and reports • Ability to sync (i.e. export) and import data into Primavera and Cobra to the lifecycle baseline file

Carlos Castillo, Jerel Nelson↗

ACCELERATED THERMAL AGING OF HARVESTED HYPALON JACKET FOR REMAINING USEFUL LIFE DETERMINATION AND DIAGNOSIS

For nuclear power plants (NPPs) that are considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated as consistent with 80 years. These values were slightly below previous measurements and could either be attributed to in-service degradation or variations in material properties from a given manufacturer. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

Glass III, Samuel W.↗

Rooftop Unit Replacement: adidas RTU Planned Replacement Program

This case study describes adidas’ successful implementation of a planned RTU replacement program designed to standardize equipment features and reduce costs, enabling the company to streamline acquisitions and ensure each location had the required equipment.

rooftop unit, RTU, replacement, retail, HVAC, air ↗

Silicon Materials and Devices

To contribute to the U.S. Department of Energy's involvement with the U.S. photovoltaic (PV) industry's efforts to meet very competitive PV efficiency, cost, and reliability goals, NREL's Silicon PV program focuses on next-generation, high-efficiency silicon (Si) PV.

14 SOLAR ENERGY↗

Electrical Substation Configuration Effect on Substation Reliability

It is crucial that the U.S. electrical grid be reliable, due to its critical role in the economy and our national defense/security. Many common tasks and industrial operations rely on proper electrical power distribution. In designing new bus systems or evaluating existing ones, the type of configuration employed affects the level of risk, reliability, maintenance, and cost involved. The present work utilizes Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) to perform a probabilistic risk assessment (PRA)-based sensitivity study on substation reliability in regard to different bus configurations. This study examines single bus, main and transfer, breaker and a half, double bus/double breaker, and ring bus configurations applied to busses with different numbers of lines. The case variances, methods, and rankings presented herein can help guide bus configurations for electrical grid design/analysis in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Income Energy Affordability Data (LEAD) Tool

The Low-income Energy Affordability Data (LEAD) tool was created to provide data, such as energy burden, to stakeholders to make data driven decisions. The LEAD Tool provides a starting point for local governments, NGOs, companies, etc. to find areas with higher energy burden and cost to inform decisions about funding distribution and program qualifications. This presentation was given to energy efficiency and conservation block grant program applicants to explain how this tool can help them develop their energy efficiency and conservation strategy.

ENERGY PLANNING, POLICY, AND ECONOMY↗

The credit impact of climate change

The energy industry is bracing for a carbon-constrained world, but the ways governments choose to control carbon around the globe may have vastly different impacts on company bottom lines. The article concludes that, ultimately, any system will be effective only when it makes emissions costly. Policymakers will have to sort out several issues, primarily those pertaining to cap and trade versus a carbon tax; allocations versus auctions of credits; acceptance of global offsets, and economy-wide versus sectoral approaches. The author believes the US eventually will adopt an approach that will attempt to avoid the spectacle of coal power plants making surplus profits from emissions allowance, as has happened in Europe, while also minimizing costs to the most affected units at the program onset. In theory, this should provide these units time to deploy the most optimal abatement measures. 1 ref., 3 figs.

20 FOSSIL-FUELED POWER PLANTS↗

Accelerated thermal aging of harvested hypalon jacket for remaining useful life determination and diagnosis - 210

For nuclear power plants (NPPs) considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80 deg. C and 120 deg. C was carried out on a multi-conductor control rod cable that had been inservice for over 30 years and was made by Boston Insulated Wire with Hypalon{sup TM} cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45 deg. C, was estimated to be 80 years. These values were slightly below previous measurements on similar BIW Hypalon cable jacket and could either be attributed to inservice degradation or variations in material properties from process variations. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sabathani Community Center Solar + Battery Resilience Hub

To meet south Minneapolis, Minnesota's clean energy goals, the community exploring opportunities to transition Sabathani Community Center into a resilience hub to provide critical community services during power outages, including shelter and warmth or cooling, continued food distribution services, and more. The National Renewable Energy Laboratory, through the U.S. Department of Energy's Communities LEAP (Local Energy Action Program) pilot, worked with Sabathani to quantify the costs and benefits of installing stand-alone solar photovoltaics (PV) and PV paired with battery systems to reduce energy costs, avoid emissions, and improve resilience.

battery energy storage system↗

Minneapolis American Indian Center Solar + Battery Resilience Hub

To meet south Minneapolis, Minnesota's clean energy goals, the community exploring opportunities to transition Minneapolis American Indian Center (MAIC) into a resilience hub to provide critical community services during power outages, including shelter and warmth or cooling, continued food distribution services, and more. The National Renewable Energy Laboratory, through the U.S. Department of Energy's Communities LEAP (Local Energy Action Program) pilot, worked with MAIC to quantify the costs and benefits of installing stand-alone solar photovoltaics (PV) and PV paired with battery systems to reduce energy costs, avoid emissions, and improve resilience.

BESS↗

Accelerated Thermal Aging of Harvested Hypalon Jacket for Remaining Useful Life Determination and Diagnosis

For nuclear power plants (NPPs) considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon™ cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated to be 80 years. These values were slightly below previous measurements on similar BIW Hypalon cable jacket and could either be attributed to in-service degradation or variations in material properties from process variations. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

cable aging, cable insulation, Hypalon, second lic↗

Distributed Energy Resources On-Site Optimization for Commercial Buildings with Electric and Thermal Storage Technologies

The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic as well as environmental attractiveness of on-site generation (e.g., PV, fuel cells, reciprocating engines or microturbines operating with or without CHP) and contribute to enhanced demand response. In order to examine the impact of storage technologies on demand response and carbon emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that has the minimization of annual energy costs as its objective function. By implementing this approach in the General Algebraic Modeling System (GAMS), the problem is solved for a given test year at representative customer sites, such as schools and nursing homes, to obtain not only the level of technology investment, but also the optimal hourly operating schedules. This paper focuses on analysis of storage technologies in DER optimization on a building level, with example applications for commercial buildings. Preliminary analysis indicates that storage technologies respond effectively to time-varying electricity prices, i.e., by charging batteries during periods of low electricity prices and discharging them during peak hours. The results also indicate that storage technologies significantly alter the residual load profile, which can contribute to lower carbon emissions depending on the test site, its load profile, and its adopted DER technologies.

25 ENERGY STORAGE↗

Pathway and Resource Overview (Presentation)

This presentation provides information about hydrogen pathway analysis, which is analysis of the total levelized cost (including return on investment). Well-to-wheels (WTW) energy use, and WTW emissions for hydrogen production, delivery, and distribution pathways.

08 HYDROGEN↗

Characterizing the Response of Commercial and Industrial Facilities to Dynamic Pricing Signals from the Utility

We describe a method to generate statistical models of electricity demand from Commercial and Industrial (C&I) facilities including their response to dynamic pricing signals. Models are built with historical electricity demand data. A facility model is the sum of a baseline demand model and a residual demand model; the latter quantifies deviations from the baseline model due to dynamic pricing signals from the utility. Three regression-based baseline computation methods were developed and analyzed. All methods performed similarly. To understand the diversity of facility responses to dynamic pricing signals, we have characterized the response of 44 C&I facilities participating in a Demand Response (DR) program using dynamic pricing in California (Pacific Gas and Electric's Critical Peak Pricing Program). In most cases, facilities shed load during DR events but there is significant heterogeneity in facility responses. Modeling facility response to dynamic price signals is beneficial to the Independent System Operator for scheduling supply to meet demand, to the utility for improving dynamic pricing programs, and to the customer for minimizing energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerogel Derived Nanostructured Thermoelectric Materials

America’s dependence on foreign sources for fuel represents a economic and security threat for the country. These non renewable resources are depleting, and the effects of pollutants from fuels such as oil are reaching a problematic that affects the global community. Solar concentration power (SCP) production systems offer the opportunity to harness one of the United States’ most under utilized natural resources; sunlight. While commercialization of this technology is increasing, in order to become a significant source of electricity production in the United States the costs of deploying and operating SCP plants must be further reduced. Parabolic Trough SCP technologies are close to meeting energy production cost levels that would raise interest in the technology and help accelerate its adoption as a method to produce a significant portion of the Country’s electric power needs. During this program, Aspen Aerogels will develop a transparent aerogel insulation that can replace the costly vacuum insulation systems that are currently used in parabolic trough designs. During the Phase I program, Aspen Aerogels will optimize the optical and thermal properties of aerogel to meet the needs of this application. These properties will be tested, and the results will be used to model the performance of a parabolic trough HCE system which uses this novel material in place of vacuum. During the Phase II program, Aspen Aerogels will scale up this technology. Together with industry partners, Aspen Aerogels will build and test a prototype Heat Collection Element that is insulated with the novel transparent aerogel material. This new device will find use in parabolic trough SCP applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗