Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

Adaptive Machine Learning for Robust Diagnostics and Control of Time-Varying Particle Accelerator Components and Beams

Machine learning (ML) is growing in popularity for various particle accelerator applications including anomaly detection such as faulty beam position monitor or RF fault identification, for non-invasive diagnostics, and for creating surrogate models. ML methods such as neural networks (NN) are useful because they can learn input-output relationships in large complex systems based on large data sets. Once they are trained, methods such as NNs give instant predictions of complex phenomenon, which makes their use as surrogate models especially appealing for speeding up large parameter space searches which otherwise require computationally expensive simulations. However, quickly time varying systems are challenging for ML-based approaches because the actual system dynamics quickly drifts away from the description provided by any fixed data set, degrading the predictive power of any ML method, and limits their applicability for real time feedback control of quickly time-varying accelerator components and beams. In contrast to ML methods, adaptive model-independent feedback algorithms are by design robust to un-modeled changes and disturbances in dynamic systems, but are usually local in nature and susceptible to local extrema. In this work, we propose that the combination of adaptive feedback and machine learning, adaptive machine learning (AML), is a way to combine the global feature learning power of ML methods such as deep neural networks with the robustness of model-independent control. We present an overview of several ML and adaptive control methods, their strengths and limitations, and an overview of AML approaches.

97 MATHEMATICS AND COMPUTING↗

TU-CD-304-09: Feasibility Study for Thermoplastic Mask Set Up Monitoring Using Force Sensing Resistor (FSR) Sensor

Purpose: To improve the setup accuracy of thermoplastic mask, we developed a new monitoring method based on force sensing technology and evaluated its feasibility. Methods: The thermoplastic mask setup monitoring system consists of a force sensing resistor sensor unit, a signal transport device, a control PC and an in-house software. The system is designed to monitor pressure variation between the mask and patient in real time. It also provides a warning to the user when there is a possibility of movement. A preliminary study was performed to evaluate the reliability of the sensor unit and developed monitoring system with a head phantom. Then, a simulation study with volunteers was conducted to evaluate the feasibility of the monitoring system. Note that the sensor unit can have multiple end-sensors and every end-sensor was confirmed to be within 2% reliability in pressure reading through a screening test. Results: To evaluate the reproducibility of the proposed monitoring system in practice, we simulated a mask setup with the head phantom. FRS sensors were attached on the face of the head phantom and pressure was monitored. For 3 repeated mask setups on the phantom, the variation of the pressure was less than 3% (only 1% larger than 2% potential uncertainty confirmed in the screening test). In the volunteer study, we intended to verify that the system could detect patient movements within the mask. Thus, volunteers were asked to turn their head or lift their chin. The system was able to detect movements effectively, confirming the clinical feasibility of the monitoring system developed. Conclusion: Through the proposed setup monitoring method, it is possible to monitor patient motion inside a mask in real time, which has never been possible with most commonly used systems using non-radiographic technology such as infrared camera system and surface imaging system. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

Measurement of Neutrino-Nucleon Neutral-Current Elastic Scattering Cross-section at SciBooNE

In this thesis, results of neutrino-nucleon neutral current (NC) elastic scattering analysis are presented. Neutrinos interact with other particles only with weak force. Measurement of cross-section for neutrino-nucleon reactions at various neutrino energy are important for the study of nucleon structure. It also provides data to be used for beam flux monitor in neutrino oscillation experiments. The cross-section for neutrino-nucleon NC elastic scattering contains the axial vector form factor G A (Q 2 ) as well as electromagnetic form factors unlike electromagnetic interaction. G A is propotional to strange part of nucleon spin (Δs) in Q 2 → 0 limit. Measurement of NC elastic cross-section with smaller Q 2 enables us to access Δs. NC elastic cross-sections of neutrino-nucleon and antineutrino-nucleon were measured earlier by E734 experiment at Brookheaven National Laboratory (BNL) in 1987. In this experiment, cross-sections were measured in Q 2 > 0.4 GeV 2 region. Result from this experiment was the only published data for NC elastic scattering cross-section published before our experiment. SciBooNE is an experiment for the measurement of neutrino-nucleon scattering cross-secitons using Booster Neutrino Beam (BNB) at FNAL. BNB has energy peak at 0.7 GeV. In this energy region, NC elastic scattering, charged current elastic scattering, charged current pion production, and neutral current pion production are the major reaction branches. SciBar, electromagnetic calorimeter, and Muon Range Detector are the detectors for SciBooNE. The SciBar consists of finely segmented scintillators and 14336 channels of PMTs. It has a capability to reconstruct particle track longer than 8 cm and separate proton from muons and pions using energy deposit information. Signal of NC elastic scattering is a single proton track. In vp → vp process, the recoil proton is detected. On the other hand, most of vn → vn is invisible because there are only neutral particles in final state, but sometimes recoil neutron is scattered by proton and recoil proton is detected. Signal of this event is also single proton track. Event selection for the single proton track events using geometrical and dE/dx information of reconstructed track is performed. After the event selection, NC elastic scattering data sample is obtained. They includes vp → vp and vn → vn is obtained. Absolute cross-section as a function of Q 2 is evaluated from this NC elastic scattering data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TRIFIC: The TRIUMF Fast Ion Counter

The TRIUMF Fast Ion Counter (TRIFIC) is a tilted-grid gas counter detector for identifying the impurities in radioactive ion beams (RIBs). Placed at zero degrees downstream of a primary reaction target at the TRIUMF ISAC-II facility, TRIFIC provides accurate Z identification of beam species on an event-by-event basis at a rate of up to 5 × 10 5 particles per second and functions as a beam composition monitor at rates up to 5 × 10 7 particles per second. With this additional level of diagnostics, RIB experiments at TRIUMF are able to reach levels of sensitivity not previously possible. Details pertaining to the construction and instrumentation of TRIFIC as well as results from the commissioning of the detector are introduced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-C-202-03: A Tool for Automatic Calculation of Delivered Dose Variation for Off-Line Adaptive Therapy Using Cone Beam CT

Purpose: Monitoring the delivered dose is an important task for the adaptive radiotherapy (ART) and for determining time to re-plan. A software tool which enables automatic delivered dose calculation using cone-beam CT (CBCT) has been developed and tested. Methods: The tool consists of four components: a CBCT Colleting Module (CCM), a Plan Registration Moduel (PRM), a Dose Calculation Module (DCM), and an Evaluation and Action Module (EAM). The CCM is triggered periodically (e.g. every 1:00 AM) to search for newly acquired CBCTs of patients of interest and then export the DICOM files of the images and related registrations defined in ARIA followed by triggering the PRM. The PRM imports the DICOM images and registrations, links the CBCTs to the related treatment plan of the patient in the planning system (RayStation V4.5, RaySearch, Stockholm, Sweden). A pre-determined CT-to-density table is automatically generated for dose calculation. Current version of the DCM uses a rigid registration which regards the treatment isocenter of the CBCT to be the isocenter of the treatment plan. Then it starts the dose calculation automatically. The AEM evaluates the plan using pre-determined plan evaluation parameters: PTV dose-volume metrics and critical organ doses. The tool has been tested for 10 patients. Results: Automatic plans are generated and saved in the order of the treatment dates of the Adaptive Planning module of the RayStation planning system, without any manual intervention. Once the CTV dose deviates more than 3%, both email and page alerts are sent to the physician and the physicist of the patient so that one can look the case closely. Conclusion: The tool is capable to perform automatic dose tracking and to alert clinicians when an action is needed. It is clinically useful for off-line adaptive therapy to catch any gross error. Practical way of determining alarming level for OAR is under development.

60 APPLIED LIFE SCIENCES↗

An ultra-compact, high-throughput molecular beam epitaxy growth system

We present a miniaturized molecular beam epitaxy (miniMBE) system with an outer diameter of 206 mm, optimized for flexible and high-throughput operation. The three-chamber system, used here for oxide growth, consists of a sample loading chamber, a storage chamber, and a growth chamber. The growth chamber is equipped with eight identical effusion cell ports with linear shutters, one larger port for either a multi-pocket electron beam evaporator or an oxygen plasma source, an integrated cryoshroud, retractable beam-flux monitor or quartz-crystal microbalance, reflection high energy electron diffraction, substrate manipulator, main shutter, and quadrupole mass spectrometer. The system can be combined with ultrahigh vacuum (UHV) end stations on synchrotron and neutron beamlines, or equivalently with other complex surface analysis systems, including low-temperature scanning probe microscopy systems. Substrate handling is compatible with most UHV surface characterization systems, as the miniMBE can accommodate standard surface science sample holders. We introduce the design of the system, and its specific capabilities and operational parameters, and we demonstrate the epitaxial thin film growth of magnetoelectric Cr{sub 2}O{sub 3} on c-plane sapphire and ferrimagnetic Fe{sub 3}O{sub 4} on MgO (001)

36 MATERIALS SCIENCE↗

Measurement of the 70 Ge( d , n ) 71 As cross section from 2.1 MeV to 10 MeV

This work reports experimental 70 Ge(d,n) 71 As cross sections producing Arsenic-71 (t 1/2 = 65.3 h, 28% β + ), a potentially useful diagnostic radionuclide. Target stacks containing two nat Ge foils, a nat Ni monitor foil, and an Al degrader were irradiated with 5.5–10 MeV deuterons using an FN Tandem Van de Graaff accelerator. 71 As and 61 Cu, 56 Co, and 58 Co (from nat Ni(d,x)) were quantified in the foils by high purity germanium gamma spectrometry. Furthermore, the measured cross sections are larger than previously reported and suitable for producing preclinical quantities of diagnostic radiopharmaceuticals.

07 ISOTOPE AND RADIATION SOURCES↗

Beam Stability R&D for the APS MBA Upgrade

Beam diagnostics required for the APS Multi-bend acromat (MBA) are driven by ambitious beam stability requirements. The major AC stability challenge is to correct rms beam motion to 10% the rms beam size at the insertion device source points from0.01 to 1000 Hz. The vertical plane represents the biggest challenge forAC stability, which is required to be 400 nm rms for a 4-micron vertical beam size. In addition to AC stability, long-term drift over a period of seven days is required to be 1 micron or less. Major diagnostics R&D components include improved rf beam position processing using commercially available FPGA-based BPM processors, new X-ray beam position monitors based on hard X-ray fluorescence from copper and Compton scattering off diamond, mechanical motion sensing to detect and correct long-term vacuum chamber drift, a new feedback system featuring a tenfold increase in sampling rate, and a several-fold increase in the number of fast correctors and BPMs in the feedback algorithm. Feedback system development represents a major effort, and we are pursuing development of a novel algorithm that integrates orbit correction for both slow and fast correctors down to DC simultaneously. Finally, a new data acquisition system (DAQ) is being developed to simultaneously acquire streaming data from all diagnostics as well as the feedback processors for commissioning and fault diagnosis. Results of studies and the design effort are reported.

APS MBA Upgrade↗

Transport and Non-Invasive Position Detection of Electron Beams from Laser-Plasma Accelerators

The controlled imaging and transport of ultra-relativistic electrons from laser-plasma accelerators is of crucial importance to further use of these beams, e.g. in high peak-brightness light sources. We present our plans to realize beam transport with miniature permanent quadrupole magnets from the electron source through our THUNDER undulator. Simulation results demonstrate the importance of beam imaging by investigating the generated XUV-photon flux. In addition, first experimental findings of utilizing cavity-based monitors for non-invasive beam-position measurements in a noisy electromagnetic laser-plasma environment are discussed.

43 PARTICLE ACCELERATORS↗

SU-E-T-532: Left-Sided Breast Cancer Irradiation Using Volumatric Modulated Arc Therapy: An Evaluation of Multiple Commercial Systems

Purposes: There has been growing interest in treating breast cancer using VMAT technique. Our goal is to compare the dosimetry and treatment delivery parameters for the left-sided breast cancer treatment using various VMAT platforms from commercially available planning systems. Methods: Five consecutive left-sided breast cancer patients initially treated with conventional 3D-conformal radiotherapy (3DCRT) were selected. Four VMAT plans using most popular treatment planning systems, including Eclipse (Version 11, Varian), Pinnacle (Version 9.8, Philips), Monaco (Version 2.03, Elekta) and helical Tomotherapy (V4.0, Accuray). The same structure set and same planning goals were used for all VMAT plans. The dosimetric parameters including target coverage and minimum/maximum/mean, dose-volume endpoints for the selected normal structures: the heart, ipsilateral-/contralateral lung and breast, were evaluated. Other dosimetric indices including heterogeneity index (HI) were evaluated. The treatment delivery parameters, such as monitor unit (MUs) and delivery time were also compared. Results: VMAT increases dose homogeneity to the treated volume and reduces the irradiated heart and left-lung volumes. Compared to the 3DCRT technique, all VMAT plans offer better heart and left-lung dose sparing; the mean heart doses were 4.5±1.6(Monaco), 1.2±0.4(Pinnacle), 1.3± (Eclipse) and 5.6±4.4(Tomo), the mean left-lung doses were 5.9±1.5(Monaco), 3.7±0.7(Pinnacle), 1.4± (Eclipse) and 5.2±1.6 (Tomo), while for the 3DCRT plan, the mean heart and left-Lung doses were 2.9±2.0, and 6.8±4.4 (Gy) respectively. The averaged contralateral-breast and lung mean doses were higher in VMAT plans than the 3DCRT plans but were not statistically significant. Among all the VMAT plans, the Pinnacle plans often yield the lowest right-lung/breast mean doses, and slightly better heterogeneity indices that are similar to Tomotherapy plans. Treatment delivery time of the VMAT plans (except helical Tomotherapy IMRT) is estimated to be comparable with the conventional 3DCRT. Conclusion: VMAT achieves equal or better PTV coverage and comparable OARs sparing compared to the conventional 3DCRT techniques.

60 APPLIED LIFE SCIENCES↗

A comparison of volumetric modulated arc therapy and sliding-window intensity-modulated radiotherapy in the treatment of Stage I-II nasal natural killer/T-cell lymphoma

This article is aimed to compare the dosimetric differences between volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) for Stage I-II nasal natural killer/T-cell lymphoma (NNKTL). Ten patients with Stage I-II NNKTL treated with IMRT were replanned with VMAT (2 arcs). The prescribed dose of the planning target volume (PTV) was 50 Gy in 25 fractions. The VMAT plans with the Anisotropic Analytical Algorithm (Version 8.6.15) were based on an Eclipse treatment planning system; the monitor units (MUs) and treatment time (T) were scored to measure the expected treatment efficiency. All the 10 patients under the study were subject to comparisons regarding the quality of target coverage, the efficiency of delivery, and the exposure of normal adjacent organs at risk (OARs). The study shows that VMAT was associated with a better conformal index (CI) and homogeneity index (HI) (both p < 0.05) but slightly higher dose to OARs than IMRT. The MUs with VMAT (650.80 ± 24.59) were fewer than with IMRT (1300.10 ± 57.12) (relative reduction of 49.94%, p = 0.00) when using 2-Gy dose fractions. The treatment time with VMAT (3.20 ± 0.02 minutes) was shorter than with IMRT (7.38 ± 0.18 minutes) (relative reduction of 56.64%, p = 0.00). We found that VMAT and IMRT both provide satisfactory target dosimetric coverage and OARs sparing clinically. Likely to deliver a bit higher dose to OARs, VMAT in comparison with IMRT, is still a better choice for treatment of patients with Stage I-II NNKTL, thanks to better dose distribution, fewer MUs, and shorter delivery time.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-302: Dosimetric Comparison Between Volumetric Modulated Arc Radiotherapy and Intensity-Modulated Radiotherapy for Locally Recurrent Nasopharyngeal Carcinoma

Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for locally recurrent nasopharyngeal carcinoma. Methods: CT datasets of eleven nasopharyngeal-carcinoma patients were included. Dual-arc VMAT and seven-field IMRT plans were created for each case, and were then compared in terms of conformity index (CI), homogeneity index (HI) of the planning target volume (PTV), organ-at-risk (OAR) sparing, monitor unit (MU) and delivery time. Results: The D98% (near-minimal dose) of PTV in the VMAT plans was slightly lower than that of the IMRT plans (P < 0.05), while the CI was higher than that of the IMRT plans (P < 0.05). No significant difference was found in the HI between the two plans (P > 0.05). Compared with the IMRT plans, the VMAT plans demonstrated lower Dmean (mean dose) of the bilateral temporal lobes and the whole surrounding normal tissue (P < 0.05), but slightly higher Dmean of brainstem (P < 0.05). In terms of the other OARs, no significant differences were found (P > 0.05). The MUs of the VMAT plans (672 ± 112) was significantly lower than that of the IMRT plans (917 ± 206), by 25 ± 13% (P < 0.05). The average delivery time of the VMAT plans (2.3 ± 0.1 min) was less than that of the IMRT plans (5.1 ± 0.4 min), by 54 ± 3%. Conclusion: For locally recurrent nasopharyngeal carcinoma, the VMAT technique could achieve equivalent or superior dose distribution of the target and better protect the bilateral temporal lobes, compared with the IMRT technique. Moreover, it could reduce the MU and delivery time effectively.

60 APPLIED LIFE SCIENCES↗

A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer

The primary objective of this study was to compare dosimetric variables as well as treatment times of multiple static fields (MSFs), conformal arcs (CAs), and volumetric modulated arc therapy (VMAT) techniques for the treatment of early stage lung cancer using stereotactic body radiotherapy (SBRT). Treatments of 23 patients previously treated with MSF of 48 Gy to 95% of the planning target volume (PTV) in 4 fractions were replanned using CA and VMAT techniques. Dosimetric parameters of the Radiation Therapy Oncology Group (RTOG) 0915 trial were evaluated, along with the van't Riet conformation number (CN), monitor units (MUs), and actual and calculated treatment times. Paired t-tests for noninferiority were used to compare the 3 techniques. CA had significant dosimetric improvements over MSF for the ratio of the prescription isodose volume to PTV (R{sub 100%}, p < 0.0001), the maximum dose 2 cm away from the PTV (D{sub 2} {sub cm}, p = 0.005), and van't Riet CN (p < 0.0001). CA was not statistically inferior to MSF for the 50% prescription isodose volume to PTV (R{sub 50%}, p = 0.05). VMAT was significantly better than CA for R{sub 100%} (p < 0.0001), R{sub 50%} (p < 0.0001), D{sub 2} {sub cm} (p = 0.006), and CN (p < 0.0001). CA plans had significantly shorter treatment times than those of VMAT (p < 0.0001). Both CA and VMAT planning showed significant dosimetric improvements and shorter treatment times over those of MSF. VMAT showed the most favorable dosimetry of all 3 techniques; however, the dosimetric effect of tumor motion was not evaluated. CA plans were significantly faster to treat, and minimize the interplay of tumor motion and dynamic multileaf collimator (MLC) motion effects. Given these results, CA has become the treatment technique of choice at our facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-505: Inter-Comparison of Clinical Plans Created On Truebeam with Trilogy and Clinac

Purpose The purpose of this study is to investigate the dosimetric differences in clinical treatment plans when machine parameters are switched from Varian Truebeam to older Varian models and vice-versa. This is used to determine the clinically-safe limits to directly transfer patients from Truebeam to Trilogy or Clinac. Methods Thirty-two patients with cancer of different treatment sites such as lung, head-and-neck, prostate and breast were studied. The clinically approved IMRT, VMAT or 3D conformal treatment plans were delivered either on Truebeam or Clinac/Trilogy. Keeping the monitor units, fraction size and other machine parameters the same, the plans were recomputed on a different Varian linear accelerator (e.g., Truebeam plans were recomputed on Trilogy and vice-versa). The plans comparison was done using the target D98 and normal organ D2, D10, D20, D30, D50 and D70 dose metrics. Results The perfraction dose-difference in the PTV-D98 for all 32 patients varied from 0.01 to −0.06 Gy with median being −0.04 Gy. For a 2Gy/fraction treatment course, this would be maximum PTV-D98 dose-difference of 6 cGy/fraction or 30 cGy/5fractions. For organs-at-risks the maximum per-fraction dosedifference in D2, D5, D10, D20, D30, D50 and D70 between Truebeam and Trilogy/Clinac plans varied from 0.06 to −0.07 Gy with median being with — 0.02 Gy. The 3D-CRT plans had relatively lower dose-difference in comparison to IMRT and VMAT plans. The dose computed on Truebeam was systematically lower than the dose computed on Trilogy/ Clinac. Conclusions for conventional fractionation schedules, assuming the maximum uncertainty of <2%, it is clinically safe to switch the treatment machine for 5 fractions. For hypo-fractionated treatments with higher dose per-fraction, plans may need to be revisited before switching the linear accelerator from Truebeam to Clinac/Trilogy or vice-versa.

60 APPLIED LIFE SCIENCES↗

SU-E-J-196: Implementation of An In-House Visual Feedback System for Motion Management During Radiation Therapy

Purpose: To describe an in-house video goggle feedback system for motion management during simulation and treatment of radiation therapy patients. Methods: This video goggle system works by splitting and amplifying the video output signal directly from the Varian Real-Time Position Management (RPM) workstation or TrueBeam imaging workstation into two signals using a Distribution Amplifier. The first signal S[1] gets reconnected back to the monitor. The second signal S[2] gets connected to the input of a Video Scaler. The S[2] signal can be scaled, cropped and panned in real time to display only the relevant information to the patient. The output signal from the Video Scaler gets connected to an HDMI Extender Transmitter via a DVI-D to HDMI converter cable. The S[2] signal can be transported from the HDMI Extender Transmitter to the HDMI Extender Receiver located inside the treatment room via a Cat5e/6 cable. Inside the treatment room, the HDMI Extender Receiver is permanently mounted on the wall near the conduit where the Cat5e/6 cable is located. An HDMI cable is used to connect from the output of the HDMI Receiver to the video goggles. Results: This video goggle feedback system is currently being used at two institutions. At one institution, the system was just recently implemented for simulation and treatments on two breath-hold gated patients with 8+ total fractions over a two month period. At the other institution, the system was used to treat 100+ breath-hold gated patients on three Varian TrueBeam linacs and has been operational for twelve months. The average time to prepare the video goggle system for treatment is less than 1 minute. Conclusion: The video goggle system provides an efficient and reliable method to set up a video feedback signal for radiotherapy patients with motion management.

60 APPLIED LIFE SCIENCES↗

Pilot tone as a key to improving the spatial resolution of eBPMs

At Elettra, the Italian synchrotron light source, an internal project has been started to develop an electron beam position monitor capable of achieving sub-micron resolution with a self-compensation feature. In order to fulfil these requirements, a novel RF front end has been designed. A high isolation coupler combines the input signals with a known pilot tone which is generated by the readout system. This allows the parameters of the four channels to be continuously calibrated, by compensating the different responses of each channel. A similar technique is already known, but for the first time experimental results have shown the improvement in resolution due to this method. The RF chain was coupled with a 4-channel digitizer based on 160 MHz, 16 bits ADCs and an Altera Stratix FPGA. At first, no additional processing was done in the FPGA, collecting only the raw data from the ADCs; the position was calculated through the FFT of each signal. A simulation was also performed to verify the analytic relation between spatial resolution and signal-to-noise ratio; this was very useful to better understand the behaviour of the system with different sources of noise (aperture jitter, thermal noise, etc.). The experimental data were compared with the simulation, showing indeed a perfect agreement with the latter and confirming the capability of the system to reach sub-micrometric accuracy. Therefore, the use of the pilot tone greatly improves the quality of the system, correcting the drifts and increasing the spatial resolution by a factor of 4 in a time window of 24 hours.

43 PARTICLE ACCELERATORS↗

SU-E-T-178: Clinical Feasibility of Multi-Leaf Collimator Based Dynamic Wedge

Purpose: A multi-leaf collimator (MLC) based dynamic wedge (MDW), which provide similar dose profile of physical wedge (PW) along x-jaw direction while significant monitor unit (MU) reduction, was developed and investigated for clinical use. Methods: A novel technique was used to create the wedge profile using MLC. A modification was applied to the DICOM-RT format file of the plan made with the PW to replace PW with MDW. The Varian enhanced dynamic wedge profile was used to produce MLC sequence, while the MU of the wedged field was recalculated using PW factor and fluence map. The profiles for all possible MDWs to substitute PWs were verified in 6/15 MV x-ray irradiations. New plans with MDWs were compared with the original plans in 5 rectal, 5 RT breast and 5 liver cases. Results: The wedge profile of the MDW fields were well matched with those of PWs inside the fields while less scatter than PW out of the fields. For plan comparisons of the clinical cases no significant dose discrepancy was observed between MDW plan and PW’s with the dose volume histograms. The maximum and mean doses in PTVs are agreed within 1.0%. The Result of OARs of MDW plans are slightly improved in the maximum doses (3.22 ∼ 150.4 cGy) and the mean doses (17.18 ∼ 85.52 cGy) on average for all cases while the prescribed doses are 45 Gy for rectal cases, 40 or 45 Gy for liver cases and 50 Gy for breast cases. The MUs of the fields which replace PW with MDW are reduced to 68% of those of PW. Conclusion: We developed a novel dynamic wedge technique with MLC that shows clinical advantage compared to PW.

60 APPLIED LIFE SCIENCES↗