Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Alert”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Swift /UVOT discovery of Swift J221951−484240: a UV luminous ambiguous nuclear transient

We report the discovery of Swift J221951−484240 (hereafter: J221951), a luminous slow-evolving blue transient that was detected by the Neil Gehrels Swift Observatory Ultraviolet/Optical Telescope (Swift/UVOT) during the follow-up of gravitational wave alert S190930t, to which it is unrelated. Swift/UVOT photometry shows the UV spectral energy distribution of the transient to be well modelled by a slowly shrinking blackbody with an approximately constant temperature of T ∼ 2.5 × 10 4 K. At a redshift z = 0.5205, J221951 had a peak absolute magnitude of M u,AB = −23 mag, peak bolometric luminosity Lmax = 1.1 x 10 45 ergs -1 and a total radiated energy of E > 2.6 × 10 52 erg. The archival Wide-field Infrared Survey Explorer IR photometry shows a slow rise prior to a peak near the discovery date. Spectroscopic UV observations display broad absorption lines in N V and O VI, pointing towards an outflow at coronal temperatures. The lack of emission in the higher H α lines, N I and other neutral lines is consistent with a viewing angle close to the plane of the accretion or debris disc. The origin of J221951 cannot be determined with certainty but has properties consistent with a tidal disruption event and the turn-on of an active galactic nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of redshift- and duration-dependent clustering of gamma-ray bursts

Gamma-ray bursts (GRBs) are detectable out to very large distances and as such are potentially powerful cosmological probes. Historically, the angular distribution of GRBs provided important information about their origin and physical properties. As a general population, GRBs are distributed isotropically across the sky. However, there are published reports that once binned by duration or redshift, GRBs display significant clustering. We have studied the redshift- and duration-dependent clustering of GRBs using proximity measures and kernel density estimation. Utilizing bursts detected by Burst and Transient Source Experiment, Fermi/gamma-ray burst monitor, and Swift/Burst Alert Telescope, we found marginal evidence for clustering in very short duration GRBs lasting less than 100 ms. As a result, our analysis provides little evidence for significant redshift-dependent clustering of GRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

Demographics, sleep, and daily patterns of caffeine intake of shift workers in a nationally representative sample of the US adult population

Abstract Study Objective Caffeine is the most widely consumed stimulant in the world, and sociodemographic factors including occupation are associated with intake. Shift work, required in various occupations, is associated with poor sleep, inadequate diet, and adverse health effects. Using a large nationally representative database, demographics, sleep, and caffeine intake of US adults working various shifts were assessed. Methods The 24-hour dietary recall data from NHANES 2005–2010 (N = 8,500) were used to estimate caffeine intake from foods and beverages. Work shifts were self-reported as follows: regular day shift; evening shift; night shift; rotating shift; or other shift. Regression analyses assessed associations of shift work with caffeine intake after adjustment for sociodemographic factors. Results Approximately 74% of employed adults were day-shift workers and 26% were nonday-shift workers. Night-shift workers slept for 6.25 ± 0.09 hours per day, somewhat less than day-shift workers who only slept 6.83 ± 0.02 hours (p < .0001). Mean 24-hour weekday caffeine intake of evening-, night-, and rotating-shift workers (217 ± 23, 184 ± 19, and 206 ± 15 mg, respectively) was similar (p > .3) to day-shift workers (203 ± 5 mg). Regardless of work schedule, individuals consumed the most caffeine during morning hours. Evening- and night-shift workers reported consuming 36%–46% less caffeine during their work hours and 72%–169% more during nonwork hours than day-shift workers (p < .01). Conclusions Total daily caffeine intake of shift workers is similar to nonshift workers; most caffeine is consumed in the morning regardless of shift. Because shift workers consume less caffeine during regular work hours and more during nonwork hours than day workers, they may be using caffeine to, in part, optimize off-duty alertness.

Lieberman, Harris R.↗

Search for multimessenger signals in NOvA coincident with LIGO/Virgo detections

Using the NOvA neutrino detectors, a broad search has been performed for any signal coincident with 28 gravitational wave events detected by the LIGO/Virgo Collaboration between September 2015 and July 2019. For all of these events, NOvA is sensitive to possible arrival of neutrinos and cosmic rays of GeV and higher energies. For five (seven) events in the NOvA Far (Near) Detector, timely public alerts from the LIGO/Virgo Collaboration allowed recording of MeV-scale events. No signal candidates were found.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weak chaos and the 'melting transition' in a confined microplasma system

We present results demonstrating the occurrence of changes in the collective dynamics of a Hamiltonian system which describes a confined microplasma characterized by long-range Coulomb interactions. In its lower energy regime, we first detect macroscopically the transition from a 'crystallinelike' to a 'liquidlike' behavior, which we call the 'melting transition'. We then proceed to study this transition using a microscopic chaos indicator called the smaller alignment index (SALI), which utilizes two deviation vectors in the tangent dynamics of the flow and is nearly constant for ordered (quasiperiodic) orbits, while it decays exponentially to zero for chaotic orbits as exp[-(lambda{sub 1}-lambda{sub 2})t], where lambda{sub 1}>lambda{sub 2}>0 are the two largest Lyapunov exponents. During the melting phase, SALI exhibits a peculiar stairlike decay to zero, reminiscent of 'sticky' orbits of Hamiltonian systems near the boundaries of resonance islands. This alerts us to the importance of the DELTAlambda=lambda{sub 1}-lambda{sub 2} variations in that regime and helps us identify the energy range over which 'melting' occurs as a multistage diffusion process through weakly chaotic layers in the phase space of the microplasma. Additional evidence supporting further the above findings is given by examining the GALI{sub k} indices, which generalize SALI (=GALI{sub 2}) to the case of k>2 deviation vectors and depend on the complete spectrum of Lyapunov exponents of the tangent flow about the reference orbit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NeuDiff Agent: a governed AI workflow for single-crystal neutron crystallography

Large-scale facilities increasingly face analysis and reporting latency as a limiting step in scientific throughput, particularly for structural studies that require iterative reduction, integration, refinement and validation. To improve the time to result and analysis efficiency, NeuDiff Agent is introduced as a governed, tool-using AI workflow for TOPAZ at the Spallation Neutron Source. NeuDiff Agent takes instrument data through reduction, integration, refinement and validation to a validated crystal structure and a publication-ready CIF. NeuDiff Agent coordinates established crystallographic tools under explicit governance by restricting actions to allowlisted tools, enforcing fail-closed verification gates at key workflow boundaries, and capturing complete provenance for inspection, auditing and controlled replay. The present benchmark is limited to structural crystallography for periodic structures; magnetic structure analysis and incommensurate or superspace refinement are outside the scope of the current workflow. Performance is assessed using a fixed prompt protocol and repeated end-to-end runs with two large language model backends, with user and machine time partitioned and intervention burden and recovery behaviors quantified under gating. In a reference-case benchmark, NeuDiff Agent reduces wall time from 435 min (manual) to 86.5 ± 4.7 to 94.4 ± 3.5 min (4.6–5.0× faster) while producing a validated CIF with no checkCIF level A or B alerts. These results establish a practical route to deploy agentic AI in facility crystallography while preserving traceability and publication-facing validation requirements.

Xiao, Zhongcan [ORNL] (ORCID:0000000220761961)↗

Kensor: Coordinated Intelligence from Co-Located Sensors

Internet of Things (IoT) is becoming more pervasive in many installations, including homes, manufacturing plants, and industrial facilities of all kinds. The data that IoT produces is a reflection of usual behavior such as daily routines and scheduled tasks, but also from unexpected behavior due to unintentional or undesirable abnormalities. Here, we focus on achieving coordinated intelligence about normal and abnormal phenomena from multiple sensors that are geographically colocated in close proximity, monitoring and controlling a set of co-located devices. Given a set of co-located sensors, we seek an intelligent approach that would automatically determine the “normal” patterns of behaviors among the correlated sensors. After normal behavior is extracted, later monitoring should detect any deviant variations over time. An example application is an entry monitoring and alert system for facilities such as nuclear reactors, where badge readers, door locks, lights, weight trackers and other co-located sensors at the entry point are collectively tracked. To address this problem, we identify the possible solution approach that can be used to solve its different variants. The implemented model is developed as a combination of rules and Markov Chain methods.

Kotevska, Olivera↗

Autonomous Rule Creation for Intrusion Detection

Many computational intelligence techniques for anomaly based network intrusion detection can be found in literature. Translating a newly discovered intrusion recognition criteria into a distributable rule can be a human intensive effort. This paper explores a multi-modal genetic algorithm solution for autonomous rule creation. This algorithm focuses on the process of creating rules once an intrusion has been identified, rather than the evolution of rules to provide a solution for intrusion detection. The algorithm was demonstrated on anomalous ICMP network packets (input) and Snort rules (output of the algorithm). Output rules were sorted according to a fitness value and any duplicates were removed. The experimental results on ten test cases demonstrated a 100 percent rule alert rate. Out of 33,804 test packets 3 produced false positives. Each test case produced a minimum of three rule variations that could be used as candidates for a production system.

97 MATHEMATICS AND COMPUTING↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaics Systems

Self-monitoring and diagnosing technology for photovoltaic (PV) systems is a method to reduce energy production losses. The proposed technology will enable existing panel-level power optimizers and inverters in a PV system to actively perturb the system, measure its response to these small-signal perturbations, and detect any changes in the small-signal impedances. Impedance measurement will be used to identify specific faults and power degradation trends in a PV panel. This information can be used to instantly alert Operations and Maintenance (O&M) personnel of the need for corrective action, thereby reducing energy production losses earlier relative to standard PV systems.

Panchal, Jeet↗

SNNPG: Using Spiking Neural Networks to Detect Attacks in the Power Grid

We explore the potential of Spiking Neural Networks (SNN) to enhance the security of power grid operations by detecting False Data Injection (FDI) attacks. These attacks manipulate PMU readings, leading to erroneous control decisions and grid disruptions. We develop a method to convert Phase Measurement Unit (PMU) data into spike trains, capturing both temporal and spatial dimensions. Using an SNN model, we conduct evaluations with simulated power grid data, showcasing accuracy in detecting FDI attacks. SNN models rapidly identify anomalies in real-time PMU data, safeguarding grid operations by alerting operators to irregular readings and preventing incorrect decisions.

artificial intelligence↗

Method for Assessment of Security-Relevant Settings in Anomaly-Based Intrusion Detection for Industrial Control Systems

Ensuring the integrity of Ethernet-based networks is a challenging and constantly evolving domain. This problem is exacerbated for those operational technology (OT) networks supporting industrial control systems (ICS) since much of that equipment was originally designed to be on a network that was isolated and generally considered free of malefactors. Increasing pressure to bridge these systems with traditional information technology (IT) networks has introduced a bevy of new threats. In response, both academia and industry have responded with security solutions tailored to ICS environments. Deploying these protection systems often involves several configuration choices. While some of these choices are clear (e.g., block/enable protocol X) others are far more subjective (e.g. alert threshold == 3.43). Further complicating the situation, while often similar to IT networks, OT networks have unique challenges and characteristics that make the task of protecting them simultaneously more difficult and straight forward.Extant solutions for quantifying the relative security of intrusion detection systems fail to effectively support the operators of said systems with understanding the impact of various configuration changes. Further, they assume that the attacks are static and not subject to manipulation or alteration in the face of defenses. In this paper, we present a threat-based method for quantifying the relative impact of various security settings for intrusion detection systems (IDSs) within ICS environments. This method provides operational staff with a clear understanding of the relative impact of their settings and assumes that the attacks levied against them are dynamic. The model is described in detail, we apply the model to a synthetic data set, and discuss the inferences that can be made and what types of decisions they could be used to support.

Gillen, Rob↗

The Recent Improvements of the SNS Extraction Kicker Power Supplies

A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.

Tan, Yugang↗

Predicting Power Outage During Extreme Weather with EAGLE-I and NWS Datasets

Extreme weather events, such as hurricanes, severe thunderstorms, and floods can significantly disrupt power grid systems, leading to electrical outages that result in inconvenience, economic losses, and life-threatening situations. There is a growing need for a robust and precise predictive model to forecast power outages, which will help prioritize emergency response before, during, and after extreme weather events. In this paper, we introduce machine-learning models that predict power outage risk at the state level during and after extreme weather events. We jointly utilized two publicly available datasets: the U.S. historical power outage data collected by the Environment for Analysis of Geo-Located Energy Information (EAGLE-I™) system, and the National Weather Service historical weather alert data sets. We highlight our initial result and discuss future work aimed at enhancing the model's robustness and accuracy for real-world applications.

Lee, Sangkeun (Matt)↗

Bio-Inspired Cyber Security for Smart Grid Deployments

mart grid technologies are transforming the electric power grid into a grid with bi-directional flows of both power and information. Operating millions of new smart meters and smart appliances will significantly impact electric distribution systems resulting in greater efficiency. However, the scale of the grid and the new types of information transmitted will potentially introduce several security risks that cannot be addressed by traditional, centralized security techniques. We propose a new bio-inspired cyber security approach. Social insects, such as ants and bees, have developed complex-adaptive systems that emerge from the collective application of simple, light-weight behaviors. The Digital Ants framework is a bio-inspired framework that uses mobile light-weight agents. Sensors within the framework use digital pheromones to communicate with each other and to alert each other of possible cyber security issues. All communication and coordination is both localized and decentralized thereby allowing the framework to scale across the large numbers of devices that will exist in the smart grid. Furthermore, the sensors are light-weight and therefore suitable for implementation on devices with limited computational resources. This paper will provide a brief overview of the Digital Ants framework and then present results from test bed-based demonstrations that show that Digital Ants can identify a cyber attack scenario against smart meter deployments.

McKinnon, Archibald D.↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

The CommonGround Visual Paradigm for Biosurveillance

Biosurveillance is a critical area in the intelligence community for real-time detection of disease outbreaks. Identifying epidemics enables analysts to detect and monitor disease outbreaks that might be spread from natural causes or from possible biological warfare attacks. Containing these events and disseminating alerts requires the ability to rapidly find, classify and track harmful biological signatures. In this paper, we describe a novel visual paradigm to conduct biosurveillance using an Infectious Disease Weather Map. Our system provides a visual common ground in which users can view, explore and discover emerging concepts and correlations such as symptoms, syndromes, pathogens, and geographic locations.

Livnat, Yarden↗

Computationally Efficient Neural Network Intrusion Security Awareness

An enhanced version of an algorithm to provide anomaly based intrusion detection alerts for cyber security state awareness is detailed. A unique aspect is the training of an error back-propagation neural network with intrusion detection rule features to provide a recognition basis. Network packet details are subsequently provided to the trained network to produce a classification. This leverages rule knowledge sets to produce classifications for anomaly based systems. Several test cases executed on ICMP protocol revealed a 60% identification rate of true positives. This rate matched the previous work, but 70% less memory was used and the run time was reduced to less than 1 second from 37 seconds.

97 MATHEMATICS AND COMPUTING↗

Security Evaluation of Two Intrusion Detection Systems in Smart Grid SCADA Environment

The increased complexity and interconnectivity of SCADA infrastructure in the power system have exposed it to the multitude of vulnerabilities. There is a growing emphasis towards developing an efficient intrusion detection system (IDS) to strengthen the security of the SCADA control system. This is a research-in-progress paper which presents the application of two anomaly-based intrusion detection systems (AIDS) in detecting the stealthy cyber-attack on the SCADA control system. We have applied the IDS tools Snort and Bro, in designing the IDS and later, compared their performances in terms of detection rate and latency in the alert packets with a motive of selecting better IDS for the SCADA security. Specifically, the timing-based rule is applied to identify the malicious packets based on the high temporal frequency in the network traffic. For the case study, we have implemented the SCADA based protection scheme which performs an autonomous protection to mitigate the system disturbances. We first implemented the stealthy cyber-attack which compromised the SCADA controller followed by data integrity attack on the system generator. Next, we perform the impact analysis during the attack followed by performance evaluation of IDS tools. Our experimental results show that the IDS tools are efficient in detecting cyber-attacks within an acceptable time frame for different sizes of network packets.

24 POWER TRANSMISSION AND DISTRIBUTION↗