Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator Control C#”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Hedgehog signaling contributes to basic fibroblast growth factor-regulated fibroblast migration

Fibroblast migration is a central process in skin wound healing, which requires the coordination of several types of growth factors. bFGF, a well-known fibroblast growth factor (FGF), is able to accelerate fibroblast migration; however, the underlying mechanism of bFGF regulation fibroblast migration remains unclear. Through the RNA-seq analysis, we had identified that the hedgehog (Hh) canonical pathway genes including Smoothened (Smo) and Gli1, were regulated by bFGF. Further analysis revealed that activation of the Hh pathway via up-regulation of Smo promoted fibroblast migration, invasion, and skin wound healing, but which significantly reduced by GANT61, a selective antagonist of Gli1/Gli2. Western blot analyses and siRNA transfection assays demonstrated that Smo acted upstream of phosphoinositide 3-kinase (PI3K)-c-Jun N-terminal kinase (JNK)-β-catenin to promote cell migration. Moreover, RNA-seq and qRT-PCR analyses revealed that Hh pathway genes including Smo and Gli1 were under control of β-catenin, suggesting that β-catenin turn feedback activates Hh signaling. Taken together, our analyses identified a new bFGF-regulating mechanism by which Hh signaling regulates human fibroblast migration, and the data presented here opens a new avenue for the wound healing therapy. - Highlights: • bFGF regulates Hedgehog (Hh) signaling in fibroblasts. • The Smo and Gli two master regulators of Hh signaling positively regulate fibroblast migration. • Smo facilitates β-catenin nuclear translocation via activation PI3K/JNK/GSK3β. • β-catenin positively regulates fibroblast cell migration and the expression of Hh signaling genes including Smo and Gli.

60 APPLIED LIFE SCIENCES↗

Process Performance of Optima XEx Single Wafer High Energy Implanter

To meet the process requirements for well formation in future CMOS memory production, high energy implanters require more robust angle, dose, and energy control while maintaining high productivity. The Optima XEx high energy implanter meets these requirements by integrating a traditional LINAC beamline with a robust single wafer handling system. To achieve beam angle control, Optima XEx can control both the horizontal and vertical beam angles to within 0.1 degrees using advanced beam angle measurement and correction. Accurate energy calibration and energy trim functions accelerate process matching by eliminating energy calibration errors. The large volume process chamber and UDC (upstream dose control) using faraday cups outside of the process chamber precisely control implant dose regardless of any chamber pressure increase due to PR (photoresist) outgassing. An optimized RF LINAC accelerator improves reliability and enables singly charged phosphorus and boron energies up to 1200 keV and 1500 keV respectively with higher beam currents. A new single wafer endstation combined with increased beam performance leads to overall increased productivity. We report on the advanced performance of Optima XEx observed during tool installation and volume production at an advanced memory fab.

43 PARTICLE ACCELERATORS↗

Performance assessment of aero-assisted orbital transfer vehicles

Aero-assisted orbital transfer vehicles are analyzed. The aerodynamic characteristics over the flight profile and three- and six-degree-of-freedom performance analyses were determined. The important results, to date, are: (1) the aerodynamic preliminary analysis system, an interactive computer program, used to predict the aerodynamics (performance, stability, and control) for these vehicles; (2) the performance capability, e.g., maximum inclination change, maximum heating rate, and maximum sensed acceleration, can be determined using continuum aerodynamics only; (3) guidance schemes can be developed that allow for errors in atmospheric density prediction, mispredicted trim angle of attack, and off-nominal atmospheric interface conditions, even for vehicles with a low lift-to-drag ratio; and (4) multiple pass trajectories can be used to reduce the maximum heating rate.

Powell, R. W.↗

Facilities for Biological Research Aboard the International Space Station

A centrifuge designed as part of an integrated biological facility for installation onboard the International Space Station is presented. The requirements for the 2.5 m diameter centrifuge, which is designed for the support of biological experiments are discussed. The scientific objectives of the facility are to: provide a means of conducting fundamental studies in which gravitational acceleration is a controllable variable; provide a 1g control; determine the threshold acceleration for physiological response, and determine the value of centrifugation as a potential countermeasure for the biomedical problems associated with space flight. The implementation of the facility is reported on, and the following aspects of the facility are described: the host resources systems supply requirements such as power and data control; the habitat holding rack; the life sciences glove box; the centrifuge; the different habitats for cell culture, aquatic studies, plant research and insect research; the egg incubator, and the laboratory support equipment.

Souza, Kenneth A.↗

Experimental Aging and Lifetime Prediction in Grid Applications for Large-Format Commercial Li-Ion Batteries

Due to the growth of electric vehicle and stationary energy storage markets, the production and use of lithium-ion batteries has grown exponentially in recent years. For many of these applications, large-format lithium-ion batteries are being utilized, as large cells have less inactive material relative to their energy capacity and require fewer electrical connections to assemble into packs. And especially for stationary energy storage systems, where energy delivered is the only revenue source, the economics of these battery systems is highly dependent on cell lifetime. However, testing of large-format lithium-ion batteries is time consuming and requires high current channels and large testing chambers, making information on the performance of commercial, large-format lithium-ion batteries hard to come by. Here, accelerated aging test data from four commercial large-format lithium-ion batteries is reported. These batteries span both NMC-Gr and LFP-Gr cell chemistries, pouch and prismatic formats, and a range of cell designs with varying power capabilities. Accelerated aging test results are analyzed to examine both cell performance, in terms of efficiency and thermal response under load, as well as cell lifetime. Cell thermal response is characterized by measuring temperature during cycle aging, which is used to calculated a normalized thermal resistance value that may help estimate both cell cooling needs or to help extrapolate aging test results to different thermal environments. Cell lifetime is evaluated qualitatively, considering simply the average calendar and cycle life across a range of conditions, as well as quantitatively, using statistical modeling and machine-learning methods to identify predictive aging models from the accelerated aging data. These predictive aging models are then used to investigate cell sensitivities to stressors, such as cycling temperature, voltage window, and C-rate, as well as to predict cell lifetime in various stationary storage applications. Results from this work show that cell lifetime and sensitivity to aging conditions varies substantially across commercial cells, necessitating testing for specific cell formats to make quantitative lifetime predictions. That being said, all commercial cells tested here are predicted to reach at least 10-year lifetimes for stationary storage applications. Based on the aging test results and modeling, some cells are expected to be relatively insensitive to temperature and use-case, making them suited for simple use cases with little or no thermal management and simple controls, while the lifetime of other cells could be extended to 20+ years if operated with thermal management and degradation-aware controls.

battery↗

Calibration of photoelastic modulator based dichrometers: maintaining constant phase across the spectrum

Photoelastic modulators can alter the polarization state of a beam of ultraviolet, visible or infrared photons by means of periodic stress-induced differences in the refractive index of a transparent material that forms the optical element of the device and is isotropic in the absence of stress. Furthermore, they have found widespread application in instruments that characterize or alter the polarization state of a beam in fields as diverse as astronomy, structural biology, materials science and ultraviolet lithography for the manufacture of nano-scale integrated circuits. Measurement of circular dichroism, the differential absorption of left- and right circularly polarized light, and of strain-induced birefringence of optical components are major applications. Instruments using synchrotron radiation and photoelastic modulators with CaF 2 optical elements have extended circular dichroism measurements down to wavelengths of about 130 nm in the vacuum ultraviolet. Maintaining a constant phase shift between two orthogonal polarization states across a spectrum requires that the amplitude of the modulated stress be changed as a function of wavelength. For commercially available photoelastic modulators, the voltage that controls the amplitude of modulation required to produce a specified phase shift, which is a surrogate for the stress modulation amplitude, has been shown to be an approximately linear function of wavelength in the spectral region where the optical element is transparent. But, extrapolations of such straight lines cross zero voltage at a non-zero wavelength, not at zero-wavelength. For modulators with calcium fluoride and fused silica optical elements, the zero-crossing wavelength is always in the spectral region where the optical element of the modulator strongly absorbs the incident radiation, and at a wavelength less than the longest-wavelength apparent resonance deduced from experimental values of the refractive index fit to the Sellmeier equation. Using a model that relates the refractive indices of a stressed optical element to the refractive index of its unstressed state, an expression for the modulator control voltage was derived that closely fits the experimental data. Our result provides a theoretical rational for the apparently linear constant-phase programming voltage, and thus provides theoretical backing for the calibration procedure frequently used for these modulators. Lastly there are other factors that can influence the calibration of a photoelastic modulator, including temperature and atmospheric pressure, are discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low cycle fatigue and creep-fatigue behavior of Ni-based alloy 230 at 850 C

Strain-controlled low cycle fatigue (LCF) and creep-fatigue testing of Ni-based alloy 230 were carried out at 850 C. The material creep-fatigue life decreased compared with its low cycle fatigue life at the same total strain range. Longer hold time at peak tensile strain further reduced the material creep-fatigue life. Based on the electron backscatter diffraction, a novel material deformation characterization method was applied, which revealed that in low cycle fatigue testing as the total strain range increased, the deformation was segregated to grain boundaries since the test temperature was higher than the material equicohesive temperature and grain boundaries became weaker regions compared with grains. Creep-fatigue tests enhanced the localized deformation, resulting in material interior intergranular cracking, and accelerated material damage. Precipitation in alloy 230 helped slip dispersion, favorable for fatigue property, but grain boundary cellular precipitates formed after material exposure to the elevated temperature had a deleterious effect on the material low cycle fatigue and creep-fatigue property.

Creep-fatigue↗

Self-Supported Hydrous Iridium–Nickel Oxide Two-Dimensional Nanoframes for High Activity Oxygen Evolution Electrocatalysts

Oxygen evolution reaction (OER) electrocatalysts with high activity, high stability, and low costs are needed for proton-exchange membrane (PEM) electrolyzers. Based on the high cost and limited supply of iridium, approaches that result in iridium-based OER catalysts with increased catalytic activity are of significant interest. Here, we report a carbon-free, self-supported hydrous iridium-nickel oxide two-dimensional nanoframe structure synthesized by thermal treatment of iridium-decorated nickel oxide nanosheets under reducing conditions and subsequent chemical leaching in acid. The catalyst nanoarchitecture contains an interconnected network of metallic iridium-nickel alloy domains with hydrous iridium oxide and nickel oxide located in the surface region. The electrochemical oxidation step maintains the three-dimensional nanoarchitecture and results in a thin (~5 A) oxide/hydroxide surface layer. The temperature used for thermal reduction was found to strongly affect the catalyst surface structure and OER activity. Utilizing a lower thermal reduction temperature of 200 degrees C was determined to provide a higher relative surface concentration of hydroxides and nickel oxide and result in higher OER activities compared with materials treated at 300 degrees C. The 200 degrees C-treated hydrous iridium-nickel oxide electrocatalyst showed 15 times higher initial OER mass activity than commercial IrO 2 , and the activity remained 10 times higher than IrO 2 after accelerated durability testing. Density functional theory (DFT) calculations and analysis of the experimental Tafel slopes support that the second electron transfer step is the rate-limiting step for the reaction. The DFT calculations demonstrate that Ni substitution on the IrO 2 surface lowers the activation energy for adsorbed intermediates of the second electron transfer step of the OER reaction. This work establishes that noble metal-decorated metal oxide nanosheets can be transformed into high surface area, carbon-free electrocatalyst nanostructures with high catalytic activities and molecular accessibility and reveals the importance of using controlled thermal reduction temperatures to alter the surface structure and OER activity.

36 MATERIALS SCIENCE↗

Control of focusing forces and emittances in plasma-based accelerators using near-hollow plasma channels

A near-hollow plasma channel, where the plasma density in the channel is much less than the plasma density in the walls, is proposed to provide independent control over the focusing and accelerating forces in a plasma accelerator. In this geometry the low density in the channel contributes to the focusing forces, while the accelerating fields are determined by the high density in the channel walls. The channel also provides guiding for intense laser pulses used for wakefield excitation. Both electron and positron beams can be accelerated in a nearly symmetric fashion. Near-hollow plasma channels can effectively mitigate emittance growth due to Coulomb scattering for high-energy physics applications.

43 PARTICLE ACCELERATORS↗

New Improved Horizontal Electropolishing System for SRF Cavities

The best performance of niobium SRF accelerating cavities is obtained with surfaces smoothed with electropolishing chemical finishing. Jefferson Lab has recently specified, procured, installed, and commissioned a new versatile production electropolishing (EP) tool. Experience with EP research and operations at JLab as well as vendor interactions and experience guided development of the system specification. Detailed design and fabrication was awarded by contract to Semiconductor Process Equipment Corporation (SPEC). The delivered system was integrated into the JLab chemroom infrastructure and commissioned in 2020. The new EP tool provides much improved heat exchange from the circulating H₂SO₄/HF electrolyte and also the cavity via variable temperature external cooling water flow, resulting in quite uniform cavity wall temperature control and thus improved removal uniformity. With the JLab infrastructure, stabilized process temperature as low as 5 C is available. We describe the system and illustrate operational modes in this contribution.

Reece, C. E.↗

G-cueing microcontroller (a microprocessor application in simulators)

A g cueing microcontroller is described which consists of a tandem pair of microprocessors, dedicated to the task of simulating pilot sensed cues caused by gravity effects. This task includes execution of a g cueing model which drives actuators that alter the configuration of the pilot's seat. The g cueing microcontroller receives acceleration commands from the aerodynamics model in the main computer and creates the stimuli that produce physical acceleration effects of the aircraft seat on the pilots anatomy. One of the two microprocessors is a fixed instruction processor that performs all control and interface functions. The other, a specially designed bipolar bit slice microprocessor, is a microprogrammable processor dedicated to all arithmetic operations. The two processors communicate with each other by a shared memory. The g cueing microcontroller contains its own dedicated I/O conversion modules for interface with the seat actuators and controls, and a DMA controller for interfacing with the simulation computer. Any application which can be microcoded within the available memory, the available real time and the available I/O channels, could be implemented in the same controller.

Horattas, C. G.↗

In-Flight Line-Of-Sight Pointing Performance for the GOES-16 and GOES-17 Spacecraft

The Geostationary Operational Environmental Satellite-R program (GOES-R) has launched two of the next generation geostationary weather satellites, both of which are now fully operational. GOES-16 launched in November 2016, and GOES-17 launched in March 2017. In this paper, we present the pointing and pointing stability results of the two spacecraft, with specific focus on aspects of the design related to mitigating jitter. The flight instrument suite includes 6 seismic accelerometers sampled at approximately 2 kilohertz, allowing in-flight verification of pointing stability and comparison back to simulation predictions. This paper compares the observed flight results with the simulation predictions for acceleration and shock response spectrum (SRS) for various operational scenarios and instrument observation modes. Passive isolation of both the reaction wheels and the payload deck have proved to be effective in reducing jitter responses. Active Vibration Damping (AVD) of flexible-body modes attenuates the low frequency motion of the vehicle appendages, improving the low-frequency pointing performance. Knowledge of the instrument scan mirror motion is fed forward to the reaction wheel control, reducing disturbances on the spacecraft bus. Attitude knowledge and rate data are provided to the primary Earth-observing instrument with an accuracy defined by the Integrated Rate Error (IRE) requirements. The data are used to adjust instrument scanning. As we show in this paper, the in-flight performance of the GN&C (Guidance, Navigation and Control) design provides the necessary capabilities to achieve the demanding GOES-R mission objectives while its robustness enabled the simultaneous operation of the Advanced Baseline Imager (ABI) prime and redundant cryocoolers (CCs) to resolve an in-flight cooling anomaly on GOES-17.

Line-of-Sight↗

Effects of Polymer Morphology on Solvent and Catalyst Accessibility during Polyethylene and Polystyrene Autoxidation

Efficient catalytic deconstruction of plastics requires facile solvent and catalyst access to polymer substrates to minimize mass transfer effects. Autoxidation using Co(II) acetate, Mn(II) acetate, and a radical carrier in acetic acid is a promising strategy to deconstruct mixed plastic waste, yet the role of polymer morphology in governing solvent and catalyst accessibility remains poorly understood. Here, in situ simultaneous small- and wide-angle X-ray scattering (SAXS/WAXS), complemented by X-ray fluorescence (XRF) imaging and high-pressure differential scanning calorimetry (DSC), were used to elucidate interactions between acetic acid, a Co/Mn catalyst solution, and semicrystalline polyethylene (PE) and amorphous polystyrene (PS) from room temperature to 160 °C. In PE, acetic acid and catalyst access were confined to amorphous regions and cryomilled particle interfaces at room temperature, while crystalline lamellae remained intact after soaking for up to 34 h. Increasing temperature enabled solvent uptake into PE, followed by solvent-assisted softening above 100 °C, and a modest melting-point depression that removed lamellar transport barriers upon melting. Conversely for PS, acetic acid penetrated the glassy polymer without inducing chain mobility until the glass transition was reached, above which the observed structural changes were consistent with enhanced segmental mobility which enabled bulk penetration. These results suggest that polymer morphology and thermally activated physical transitions arising from diffusion and polymer–solvent interactions can influence whether autoxidation of plastics is transport-limited or kinetically controlled, providing a framework for aligning reaction conditions with reaction outcomes.

09 BIOMASS FUELS↗

The Heidelberg Ion Therapy (HIT) Accelerator Coming into Operation

The Heidelberg Ion Therapy Facility (HIT) is the first dedicated proton and carbon therapy facility in Europe. It uses full three dimensional intensity controlled raster scanning as basic treatment technique. Commissioning of the accelerator with beam was successfully finished for three fixed beam places in April 2008. A library of 60000 combinations of beam properties (ion type, treatment place, energy, intensity, beam size) is now offered to the treatment technique teams preparing the treatment systems for the clinical use. The HIT facility also comprises a gantry with full scanning properties constituting the first carbon ion gantry worldwide. The gantry can be rotated by 360 deg., so that the beam may be aimed at the patient from arbitrary directions.

43 PARTICLE ACCELERATORS↗

Study light scalar meson property from heavy meson decays

In the SU(3) symmetry limit, the ratio R {identical_to} (B(D{sup +{yields}}f{sub 0}l{sup +{nu}})+B(D{sup +{yields}{sigma}}l{sup +{nu}})/B(D{sup +{yields}}a{sub 0}{sup 0}l{sup +{nu}})) is equal to 1 if the scalar mesons are q-barq states, while it is 3 if these mesons are tentraquark states. This ratio provides a model-independent way to distinguish the descriptions for light scalar mesons. It also applies to the B{sup -{yields}}Sl{sup -{nu}}-bar, and B{sup 0}-bar{yields}J/{psi}({eta}{sub c})S decays. The SU(3) symmetry breaking effect is found to be under control, which will not spoil our method. The branching fractions of the D{sup +{yields}}Sl{sup +{nu}}, B{sup -{yields}}Sl{sup -{nu}}-bar and B{sup 0}-bar{yields}J/{psi}({eta}{sub c})S decays roughly have the order 10{sup -4}, 10{sup -5} and 10{sup -6}, respectively. The B factory experiments and ongoing BEPC-II experiments are able to measure these channels and accordingly to provide the detailed information of the scalar meson inner structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A CW FFAG for Proton Computed Tomography

An advantage of the cyclotron in proton therapy is the continuous (CW) beam output which reduces complexity and response time in the dosimetry requirements and beam controls. A CW accelerator requires isochronous particle orbits at all energie s through the acceleration cycle and present compact isochronous cyclotrons for proton therapy reach only 250 MeV (kinetic energy) which is required for patient treatment, but low for full Proton Computed Tomography (PCT) capability. PCT specifications ne ed 300-330 MeV in order for protons to transit the human body. Recent innovations in nonscaling FFAG design have achieved isochronous performance in a compact (~3 m radius) design at these higher energies. Preliminary isochronous designs are presented her e. Lower energy beams can be efficiently extracted for patient treatment without changes to the acceleration cycle and magnet currents.

43 PARTICLE ACCELERATORS↗

A pathway to synthesizing single-crystal Fe and FeCr films

Nuclear reactor environments provide a unique scientific and engineering challenge wherein materials must tolerate prolonged exposure to concurrent irradiation, elevated temperatures, and corrosive media. However, uncontrolled variability in material composition and structure often prohibits truly single-variable experiments that can reveal basic aspects of environmental damage. Here, Magnetron sputtering is used to provide a more controlled model system for these fundamental studies, yielding reproducible single-crystal Fe and FeCr thin films containing 8 and 18 at.% Cr. Electron microscopy is used to determine the systematic correlations between growth conditions and the resulting film microstructure and surface morphology. It is found that the substrate temperature and applied radio frequency (RF) bias can be tuned to obtain consistent homogeneous and single crystal films with a minimal amount of Ar impurities from the RF bias process. Epitaxial, single-crystal Fe films are obtained on MgO substrates at 500 °C with 10 Watt (W) RF bias deposition. However, when Cr is alloyed with Fe, higher substrate temperatures (600 °C) and applied RF biases (15 W) are required to achieve a similar epitaxial single-crystal FeCr film. Accelerated molecular dynamics simulations reveal that Cr impedes surface transport, explaining the need for higher temperature and bias during the growth of the Cr-bearing films.

36 MATERIALS SCIENCE↗

Plasma vasopressin and renin activity in women exposed to bed rest and +G/z/ acceleration

To study the effect of prolonged recumbency on plasma vasopressin and renin activity, eight women were subjected to 17 days of absolute bed rest. The tolerance to +3G vertical acceleration of the subjects was tested before and after 14 days of bed rest. From day 2 and through day 17 of bed rest, plasma arginine vasopressin (AVP) levels were reduced 33%. Plasma renin activity (PRA) increased 91% above ambulatory control values from days 10 through 15 of bed rest. When compared to precentrifuge values, exposure to vertical acceleration prior to bed rest provoked a 20-fold rise in mean plasma AVP but resulted in only a slight increase in PRA. After bed rest, acceleration increased plasma AVP 7-fold; however, the magnitude of this increase was less than the post +3G acceleration value obtained prior to bed rest. After bed rest, no significant rise was noted in PRA following +3G acceleration. This study demonstrates that prolonged bed rest leads to a significant rise in the PRA of female subjects, while exposure to positive vertical acceleration provokes a marked rise in plasma AVP.

Keil, L. C.↗