Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

The BiDFET Device and Its Impact on Converters

The matrix converter topology for direct ac-to-ac conversion offers elimination of the bulky and unreliable D.C. link capacitors used in the popular Voltage-Source Inverter (VSI) with a front-end rectifier. The resulting more compact and higher efficiency implementation is a desirable solution for a wide variety of applications, such as photovoltaic energy generation, motor drives, and energy storage systems. The development of matrix converters has been hampered by the lack of availability of commercial bidirectional power switches with the ability to block high voltages in the first and third quadrants, carry on state current in both quadrants with low voltage drop, exhibit large forward-biased safe-operating-area (FBSOA), and low switching power losses. Consequently, many implementations have been tried in the past using discrete devices, as listed in Table I. Two implementations utilize commonly available asymmetric blocking IGBTs, while two cases make use of SiC power MOSFETs. They generally have a large parts count (4-6 individual switches) that occupies significant space in the converter where multiple bi-directional switches are required. They also have a high on-state voltage drop that degrades efficiency. As a result, one implementation utilizes symmetric blocking IGBT to achieve a low parts count (2), but its switching losses are unacceptably high.

42 ENGINEERING↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

Designing an Intrusion Proof Adjustable Speed Drive System Controlling a Critical Process

In this paper, an intrusion proof adjustable speed drive system controlling a critical process in an industrial control system is detailed. In such a system, should the motor speed sensor signal data be compromised and/or altered via a cyber-attack, the system can potentially be unregulated, over speed and/or malfunction thereby disrupting the critical process. The proposed active detection scheme detailed in this paper introduces a private (secret) random signal termed as "watermark" into the inverter control signal that determines the PWM gating signals of the DC-AC inverter powering the motor. The watermarking signal introduced into the PWM modulation for the DC-AC inverter is shown to propagates its unique signature, which appears in all sensors signals at the inverter output such as voltage/current/speed used to control the motor. Now employing the measured data (from sensors), two statistical variance tests are conducted to identify anomalies if any in the presence of the watermarking signal. It is shown when an intrusion occurs to manipulate the sensor data to disturb and/or destabilize the process, the proposed tests immediately display a high value indicating a compromise in sensor data. It is shown that the proposed system is capable of immediate detection of a sophisticated attacks such as record/reply attack in which the actual speed sensor is disconnected and a prerecorded speed signal from the past of the same magnitude is played back to the controller. Several types of cyber-attacks such as speed reduction/increase including vibration have been tested. Extensive simulation results verify the proposed concepts. Experimental results will be discussed in the conference presentation.

Alotaibi, Faris↗

ACOPF Transmission Switching Using Open-Source MINLP Solvers

The optimal transmission switching (OTS) problem with AC physics represents a mixed integer non-linear non-convex optimization problem which can provide benefits to transmission level power system operations. In this paper we benchmark a set of open-source mixed integer non-linear programming (MINLP) solvers on the OTS problem with AC physics using the pglib set of power system test cases. Results characterizing the performance of the different solvers are reported and discussed.

ACOPF↗

Highly Reliable Multi-Port Smart Inverter Modules for PV-Based Energy Systems

Generally, large electrolytic capacitors (E-caps) are required to decouple the double-line frequency power fluctuation inherent in all single-phase dc-ac or ac-dc converters. These E-caps pose the weak link in the photovoltaic (PV) inverter because they have poor reliability as a result of short life expectancy and higher equivalent series resistance (ESR) which leads to lower system efficiency. In this paper, multiport smart dual-inverter modules are proposed for residential PV inverter systems with balanced outputs to eliminate the requirement of large decoupling capacitors, thus leading to more reliable and highly efficient inverter modules. The balanced dual outputs are controlled in phase quadrature such that the double frequency current is completely eliminated. One phase supports the standalone residential loads, and the other phase interfaces with the grid, which is synchronized to the utility grid. Also, the proposed modular configuration is scalable to accommodate higher power rating by stacking and paralleling multiple modules. Simulation results for the dual-inverter modules rated for 1 kW each are presented to validate the proposed concept. Experimental results from a controller hardware-in-the-loop (CHIL) platform also verify its feasibility.

14 SOLAR ENERGY↗

Validation of Subhourly Clipping Loss Error Corrections

Under-performance of solar PV systems is an important issue that increases risks for stakeholders, including developers, investors and operators. Recently some attention has focused on underestimation of inverter clipping losses as a possible source of over-prediction where sub-hourly solar variability is high. Several models and data sets have been analyzed over the past few years, with the aim of quantifying, predicting, and correcting underestimated clipping loss errors for systems with high DC/AC ratio and solar variability. In this research, we apply a machine learning model developed at NREL to two physical PV systems, to correct for subhourly clipping losses. For each system, we compare overall AC power output for the model taken at 1-minute intervals to AC power output taken at 1-hour intervals with the addition of the subhourly clipping correction. Our findings consistently show that the addition of the clipping loss correction lead to a reduction in mean bias error of 0.8% and 1.2% for systems A and B, respectively, with no additional filtering applied. When examining high solar variability periods where clipping is more pronounced, system A and B experienced a 1.8% and 2.7% reduction in mean bias error, respectively, when the clipping correction was applied.

machine learning↗

A Reproducible Validation of Algorithms for Estimating Array Tilt and Azimuth from Photovoltaic Power Time Series

In this research, we assess the viability of four different, publicly available algorithms for estimating the azimuth and tilt parameters of solar photovoltaic systems using only the associated AC power time series data and site latitude-longitude coordinates. In this work, we curated a benchmarking data set of 44 fixed-tilt systems, comprising 275 measured AC power inverter data streams, with known azimuth and tilt parameters. Additionally, we isolated test cases in the data set with real- world issues, including shading and clipping, to determine how algorithm performance varies based on the presence of these phenomena. Using this data set for benchmarking, we evaluated the estimated vs. actual system characteristics for each algorithm, as well as the associated algorithm execution time using a standardized benchmarking process. The two highest performing algorithms were the Solar Data Tools and the PVWatts 5- based methods, which both achieved a median absolute error of approximately 5 and 1 degrees for azimuth and tilt, respectively. During run time analysis, the SDT method was approximately 5 times faster than the PVWatts 5-based method, with the median execution time for a stream varying between 6 and 8 seconds vs. a median run time of 31 seconds for the PVWatts 5-based method.

azimuth↗

Magnetic Measurements of Fermilab Rapid-Cycling Booster Gradient Magnets

Fermilab is upgrading its Booster synchrotron to increase ramp rate and intensity. This is part of the Proton Improvement Plan (PIP-II) that will allow the Main Injector to achieve proton beam power of 1.2 MW within the next few years. This upgrade includes running the 55-year-old Booster magnets at 20 Hz instead of the usual 15 Hz, and construction of some shorter and wider aperture versions of these combined-function gradient magnets. Magnetic measurements were performed to characterize the present 15 Hz AC performance, and then again with 20 Hz ramp cycle to ensure performance and compatibility in this new operating regime. A 3 m-long curved flat-coil was developed for these measurements using Printed Circuit Board (PCB) technology. The probe also has a separate 0.5 m-long body-field probe, allowing integral, body, and end fields to be measured across 100 mm of the magnet aperture. The sampling rate for these measurements during the AC cycle was 200 kHz, and field resolution was better than 0.01%. Details of the probe, measurements, and results are presented.

DiMarco, J. [Fermilab] (ORCID:0000000228400036)↗

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Circuit Modelling of the Mechanical-Motion-Rectifier for Electrical Simulation of Ocean Wave Power Take-off

As is the case with several other mechanical power takeoffs (PTOs), the mechanical-motion-rectifier (MMR) based PTO consists of components such as one-way clutches, gears, a ball screw, mechanical couplings, and a generator. Equivalent circuit models have been created in this paper to describe the dry frictions, viscous damping, and mechanical compliances in these components, so the non-ideal efficiency and nonlinear force of the PTO can be predicted in electrical simulations by integrating these sub-circuit models. The circuit model is simplified, and its parameters are categorized as dc and ac unknowns. The dc and ac tests on the PTO are performed sequentially to extract two sets of parameters through linear regression or nonlinear curve fitting. Then, the model is validated through its prediction capability over 25 test conditions on input forces, output voltages, and efficiencies, with correlation coefficients of 0.9, 0.98, and 0.981, respectively.

42 ENGINEERING↗

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY↗

Reduced Common-Mode Voltage PWM Scheme for Full-SiC Three-Level Uninterruptible Power Supply With Small DC-Link Capacitors

In this article, a pulsewidth modulation (PWM) scheme for three-level full-SiC uninterruptible power supplies is developed to achieve a high power density. Two key passive components are selected for size reduction of the ac-ac stage: common-mode (CM) EMI filter, and dc-link capacitors. To reduce the CM noise, a new vector combination is proposed based on synchronous switching among three-phases. The proposed combinations align CM voltage (CMV) to be a single pulse per switching period. Owing to the simple shape, CMV cancellation between a three-level rectifier and inverter can be maximally utilized. A transition between the three combinations can control the drift of neutral point voltage. An equivalent carrier-based implementation is developed. Second, a simple algorithm to compensate neutral point voltage fluctuation is proposed both for differential mode (DM) and CM output voltage. Low-order harmonics on three-phase currents and an additional high-frequency CM noise by misaligned switching instant can be eliminated. The proposed compensation can be implemented by a simple correction on carrier slopes and injected zero-sequence voltage. The proposed PWM scheme is verified with 20-kW full-SiC UPS switching at 60 kHz with 140 μF dc-link capacitors.

42 ENGINEERING↗

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

42 ENGINEERING↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

Large Scale Bilevel Optimization for N-K SCOPF Using Adversarial Robustness

Ensuring a secure dispatch against multiple simultaneous outages has long been desired to maintain grid security in the presence of severe events, such as extreme weather phenomena. Traditionally denoted as N-k security constrained optimal power flow (N-k SCOPF), this problem is intractable to solve due to its size being combinatorial in the number of simultaneous outages and due to the non-convex nature of the AC network constraints. This hinders the use of N-k SCOPF for operating realistic-scale systems. In this paper, we introduce a methodology to scalably solve an AC-feasible dispatch that improves security over k simultaneous outages. Our methodology poses N-k SCOPF as a bilevel optimization problem and solves it using an adversarial robustness approach. We develop new efficient methods to solve each level of the bilevel optimization by employing knowledge of the physics of the underlying system. This yields significant improvements in speed and convergence that enable us to address the N-k SCOPF problem at scale. We demonstrate the effectiveness of our method by conducting a comprehensive analysis of an N-3 SCOPF for a 500-bus network. Furthermore, we emphasize the ability of our physics-driven techniques to handle larger systems by successfully scaling up to 12,000 buses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Cost and Benefit of Enhancing Cybersecurity for Hybrid AC/DC Grids

As critical interfaces of AC grids and DC grids inside a hybrid AC/DC grid, the voltage-sourced-converter (VSC) has been demonstrated to be vulnerable to false data injection (FDI) cyber-attacks. As a result, the cyber-attack-induced AC grid frequency deviations and DC grid voltage deviations threaten the secure operation. Here, to enhance cybersecurity in a not only feasible but also cost-effective manner, this paper proposes a cost-benefit-based cyber-defense strategy for a hybrid AC/DC grid. First, this paper establishes a spatial-temporal dual cyber-attack evaluation model, in which the cyber-attack-induced frequency and voltage deviations are modelled in both a spatially and temporally dual manner. Then, the proposed cost-benefit-based cyber-defense strategy is modelled as a VSC commitment problem to achieve the trade-off between maximizing the cyber-defense benefits and minimizing the cyber-defense costs. The VSC commitment problem is then mathematically convexified into a mixed-integer second-order cone programming (MISOCP) problem, which could be efficiently solved in an event-triggered manner against unfolding cyber-attack events. Simulation results on a test hybrid AC/DC grid verified the feasibility and the cost-effectiveness of the proposed cyber-defense strategy.

cost-benefit analysis↗