Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACUTE EXPOSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

827 records · Page 46

Quantile-specific heritability of plasma fibrinogen concentrations

Fibrinogen is a moderately heritable blood protein showing different genetic effects by sex, race, smoking status, pollution exposure, and disease status. These interactions may be explained in part by “quantile-dependent expressivity”, where the effect size of a genetic variant depends upon whether the phenotype (e.g. plasma fibrinogen concentration) is high or low relative to its distribution. Determine whether fibrinogen heritability (h 2 ) is quantile-specific, and whether quantile-specific h 2 could account for fibrinogen gene-environment interactions. Plasma fibrinogen concentrations from 5689 offspring-parent pairs and 1932 sibships from the Framingham Heart Study were analyzed. Quantile-specific heritability from offspring-parent (β OP , h 2 = 2β OP /(1+r spouse )) and full-sib regression slopes (β FS , h 2 = {(1+8r spouse β FS ) 0.05 –1}/(2r spouse )) were robustly estimated by quantile regression with nonparametric significance assigned from 1000 bootstrap samples. Quantile-specific h 2 (±SE) increased with increasing percentiles of the offspring’s age- and sex-adjusted fibrinogen distribution when estimated from β OP (P trend = 5.5x10 -6 ): 0.30±0.05 at the 10 th , 0.37±0.04 at the 25 th , 0.48±0.05 at the 50 th , 0.61±0.06 at the 75 th , and 0.65±0.08 at the 90 th percentile, and when estimated from β FS (P trend = 0.008): 0.28±0.04 at the 10 th , 0.31±0.04 at the 25 th , 0.36±0.03 at the 50 th , 0.41±0.05 at the 75 th , and 0.50±0.06 at the 90 th percentile. The larger genetic effect at higher average fibrinogen concentrations may contribute to fibrinogen’s greater heritability in women than men and in Blacks than Whites, and greater increase from smoking and air pollution for the FGB -455G>A A-allele. It may also explain greater fibrinogen differences between: 1) FGB -455G>A genotypes during acute phase reactions than usual conditions, 2) GTSM1 and IL-6 -572C>G genotypes in smokers than nonsmokers, 3) FGB -148C>T genotypes in untreated than treated diabetics, and LPL PvuII genotypes in macroalbuminuric than normoalbuminuric patients. Fibrinogen heritability is quantile specific, which may explain or contribute to its gene-environment interactions. The analyses do not disprove the traditional gene-environment interpretations of these examples, rather quantile-dependent expressivity provides an alternative explanation that warrants consideration.

59 BASIC BIOLOGICAL SCIENCES↗

Combined effects of space flight factors and radiation on humans

The probability that a dose of ionizing radiation kills a cell is about 10,000 times the probability that the cell will be transformed to malignancy. On the other hand, the number of cells killed required to significantly impact health is about 10,000 times the number that must be transformed to cause a late malignancy. If these two risks, cell killing and malignant transformation, are about equal, then the risk that occurs during a mission is more significant than the risk that occurs after a mission. The latent period for acute irradiation effects (cell killing) is about 2-4 weeks; the latent period for malignancy is 10-20 years. If these statements are approximately true, then the impact of cell killing on health in the low-gravity environment of space flight should be examined to establish an estimate of risk. The objective of this study is to synthesize data and conclusions from three areas of space biology and environmental health to arrive at rational risk assessment for radiations received by spacecraft crews: (1) the increased physiological demands of the space flight environment; (2) the effects of the space flight environment on physiological systems; and (3) the effects of radiation on physiological systems. One physiological system has been chosen: the immune response and its components, consisting of myeloid and lymphoid proliferative cell compartments. Best-case and worst-case scenarios are considered. In the worst case, a doubling of immune-function demand, accompanied by a halving of immune capacity, would reduce the endangering dose to a crew member to around 1 Gy.

Non-NASA Center↗

Human Health Countermeasures - Partial-Gravity Analogs Workshop

The experimental conditions that were deemed the most interesting by the HHC Element lead scientists are those permitting studies of the long-term effects of exposure to (a) chronic rotation when supine or in head down tilt (ground-based); and (b) long-radius centrifugation (space based). It is interesting to note that chronic ground based slow rotation room studies have not been performed since the 1960's, when the USA and USSR were investigating the potential use of AG for long-duration space missions. On the other hand, the other partial gravity analogs, i.e., parabolic flight, HUT, suspension, and short-radius centrifugation, have been regularly used in the last three decades (see review in Clément et al. 2015). Based on the workshop evaluations and the scores by the HHC scientific disciplines indicated in tables 3 and 4, simulation of partial G between 0 and 1 should be prioritized as follows: Priority 1. Chronic space-based partial-G analogs: a. Chronic space-based long-radius centrifugation. The ideal scenario would be chronic long-radius centrifugation of cells, animals and humans in a translational research approach - ideally beyond low earth orbit under deep space environmental effects and at various rotations - to obtain different G-effects. In this scenario, all physiological systems could be evaluated and the relationship between physiological response and G level established. This would be the most integrative way of defining, for the first time ever, G-thresholds for each physiological system. b. Chronic space-based centrifugation of animals. Chronic centrifugation of rodents at various G levels in space would allow for determination of AG thresholds of protection for each physiological system. In this case, all physiological systems will be of interest. Intermittent centrifugation will be of secondary interest. c. Chronic space-based centrifugation of cell cultures (RWV). Bioreactor studies of cells and cell cultures of various tissues at various G levels would allow for intracellular investigations of the effects of partial-G. Priority 2. Acute, intermittent space based partial-G analogs: a. Acute, intermittent space-based short radius human centrifugation. Intermittent centrifugation of humans would allow determination of thresholds of AG for protection of astronaut health in space. Priority 3. Chronic ground-based partial-G analogs: a. Chronic centrifugation of supine or head-down tilted humans. b. Chronic head-up tilt in humans. c. Chronic head-out graded dry immersion in humans. d. Chronic partial suspension of rodents e. Chronic rotating bioreactor cell culture studies (RWV) Priority 4. Acute ground based partial-G analogs. a. Parabolic flights. Very acute and short term effects of G levels between 0 and 1 in humans for fast responding systems like cardiovascular and sensorimotor as well as for acute responses in cell cultures and animals. b. Other acute models as indicated in table 3.

Barr, Yael↗

Pulmonary toxicity of simulated lunar and Martian dusts in mice: I. Histopathology 7 and 90 days after intratracheal instillation

NASA is contemplating sending humans to Mars and to the moon for further exploration. Volcanic ashes from Arizona and Hawaii with mineral properties similar to those of lunar and Martian soils, respectively, are used to simulate lunar and Martian environments for instrument testing. Martian soil is highly oxidative; this property is not found in Earth's volcanic ashes. NASA is concerned about the health risk from potential exposure of workers in the test facilities. Fine lunar soil simulant (LSS), Martian soil simulant (MSS), titanium dioxide, or quartz in saline was intratracheally instilled into groups of 4 mice (C57BL/6J) at 0.1 mg/mouse (low dose, LD) or 1 mg/mouse (high dose, HD). Separate groups of mice were exposed to ozone (0.5 ppm for 3 h) prior to MSS instillation. Lungs were harvested for histopathological examination 7 or 90 days after the single dust treatment. The lungs of the LSS-LD groups showed no evidence of inflammation, edema, or fibrosis; clumps of particles and an increased number of macrophages were visible after 7 days but not 90 days. In the LSS-HD-7d group, the lungs showed mild to moderate alveolitis, and perivascular and peribronchiolar inflammation. The LSS-HD-90d group showed signs of mild chronic pulmonary inflammation, septal thickening, and some fibrosis. Foci of particle-laden macrophages (PLMs) were still visible. Lung lesions in the MSS-LD-7d group were similar to those observed in the LSS-HD-7d group. The MSS-LD-90d group had PLMs and scattered foci of mild fibrosis in the lungs. The MSS-HD-7d group showed large foci of PLMs, intra-alveolar debris, mild-to-moderate focal alveolitis, and perivascular and peribronchiolar inflammation. The MSS-HD-90d group showed focal chronic mild-to-moderate alveolitis and fibrosis. The findings in the O(3)-MSS-HD-90d group included widespread intra-alveolar debris, focal moderate alveolitis, and fibrosis. Lung lesions in the MSS groups were more severe with the ozone pretreatment. The effects of O(3) and MSS coexposure appeared to be more than additive. Results for the TiO(2) and quartz controls were consistent with the known pulmonary toxicity of these compounds. The overall severity of lung injury was TiO(2) < LSS < MSS < O(3) + MSS < quartz. Except for TiO(2), the increased duration of dust presence in the lung from 7 to 90 days transformed the acute inflammatory response to a chronic inflammatory lesion. This study showed that LSS and MSS are more hazardous in the lungs than nuisance dusts.

Non-programmatic↗

On the dose calculation at the cellular level and its implications for the RBE of {sup 99m}Tc and {sup 123}I

Purpose: Based on the authors’ previous findings concerning the radiotoxicity of{sup 99m}Tc, the authors compared the cellular survival under the influence of this nuclide with that following exposure to the Auger electron emitter {sup 123}I. To evaluate the relative biological effectiveness (RBE) of both radionuclides, knowledge of the absorbed dose is essential. Thus, the authors present the dose calculations and discuss the results based on different models of the radionuclide distribution. Both different target volumes and the influence of the uptake kinetics were considered. Methods: Rat thyroid PC Cl3 cells in culture were incubated with either{sup 99m}Tc or {sup 123}I or were irradiated using 200 kV x-rays in the presence or absence of perchlorate. The clonogenic cell survival was measured via colony formation. In addition, the intracellular radionuclide uptake was quantified. Single-cell dose calculations were based on Monte Carlo simulations performed using Geant4. Results: Compared with external radiation using x-rays (D{sub 37} = 2.6 Gy), the radionuclides {sup 99m}Tc (D{sub 37} = 3.5 Gy), and {sup 123}I (D{sub 37} = 3.8 Gy) were less toxic in the presence of perchlorate. In the absence of perchlorate, the amount of activity a{sub 37} that was necessary to reduce the surviving fraction (SF) to 0.37 was 22.8 times lower for {sup 99m}Tc and 12.4 times lower for {sup 123}I because of the dose increase caused by intracellular radionuclide accumulation. When the cell nucleus was considered as the target for the dose calculation, the authors found a RBE of 2.18 for {sup 99m}Tc and RBE = 3.43 for {sup 123}I. Meanwhile, regarding the dose to the entire cell, RBE = 0.75 for {sup 99m}Tc and RBE = 1.87 for {sup 123}I. The dose to the entire cell was chosen as the dose criterion because of the intracellular radionuclide accumulation, which was found to occur solely in the cytoplasm. The calculated number of intracellular decays per cell was (975 ± 109) decays/MBq for {sup 99m}Tc and (221 ± 82) decays/MBq for {sup 123}I. Conclusions: The authors’ data indicate that extra-nuclear targets to Auger electrons exist, which is obvious from our dose calculations. When considering the dose to the cell nucleus, the authors found an enhanced RBE for{sup 99m}Tc and {sup 123}I relative to acute x-ray irradiation and pure extracellular irradiation with both radionuclides. Surprisingly, the authors did not find any radionuclide accumulation in the cell nucleus, indicating that there are additional radiosensitive targets besides the DNA. In addition, the authors demonstrated the necessity of cellular dose calculations in radiobiological experiments using unsealed radionuclides and identified the relevant parameters.

60 APPLIED LIFE SCIENCES↗

Estimation of Optimum Stimulus Amplitude for Balance Training using Electrical Stimulation of the Vestibular System

Sensorimotor changes such as posture and gait instabilities can affect the functional performance of astronauts after gravitational transitions. Sensorimotor Adaptability (SA) training can help alleviate decrements on exposure to novel sensorimotor environments based on the concept of 'learning to learn' by exposure to varying sensory challenges during posture and locomotion tasks (Bloomberg 2015). Supra-threshold Stochastic Vestibular Stimulation (SVS) can be used to provide one of many challenges by disrupting vestibular inputs. In this scenario, the central nervous system can be trained to utilize veridical information from other sensory inputs, such as vision and somatosensory inputs, for posture and locomotion control. The minimum amplitude of SVS to simulate the effect of deterioration in vestibular inputs for preflight training or for evaluating vestibular contribution in functional tests in general, however, has not yet been identified. Few studies (MacDougall 2006; Dilda 2014) have used arbitrary but fixed maximum current amplitudes from 3 to 5 mA in the medio-lateral (ML) direction to disrupt balance function in healthy adults. Giving this high level of current amplitude to all the individuals has a risk of invoking side effects such as nausea and discomfort. The goal of this study was to determine the minimum SVS level that yields an equivalently degraded balance performance. Thirteen subjects stood on a compliant foam surface with their eyes closed and were instructed to maintain a stable upright stance. Measures of stability of the head, trunk, and whole body were quantified in the ML direction. Duration of time they could stand on the foam surface was also measured. The minimum SVS dosage was defined to be that level which significantly degraded balance performance such that any further increase in stimulation level did not lead to further balance degradation. The minimum SVS level was determined by performing linear fits on the performance variable at different stimulation levels. Results from the balance task suggest that there are inter-individual differences and the minimum SVS amplitude was found to be in the range of 1 mA to 2.5 mA across subjects. SVS resulted in an average decrement of balance task performance in the range of 62%-73% across different measured variables at the minimum SVS amplitude in comparison to the control trial (no stimulus). Training using supra-threshold SVS stimulation is one of the sensory challenges used for preflight SA training designed to improve adaptability to novel gravitational environments. Inter-individual differences in response to SVS can help customize the SA training paradigms using minimal dosage required. Another application of using SVS is to simulate acute deterioration of vestibular sensory inputs in the evaluation of tests for assessing vestibular function.

Goel, R.↗

Oxidation Behavior and Property Degradation of Nuclear Graphites

During its multidecade operation in the core of nuclear reactors, graphite components are subjected to aggressive and continuous exposure to a high field of ionizing and neutron irradiation, high temperature, and various types of present and postulated chemical attacks. High density, high crystallinity polygranular synthetic graphite is unique among other materials for its extraordinary capacity of resisting and adapting to the aggression inflicted by high temperature, high energy neutron bombardment and ionizing gamma radiation. But, as a carbonaceous material, even though of very high purity, graphite is reactive towards common oxidizing agents: oxygen, carbon dioxide, water. Safe operation of HTGRs relies, among other aspects, on engineered safeguard systems for efficient and continuous protection of graphite components against oxidation. Graphite oxidation behavior was, and continues to be, an important direction of theoretical and experimental research, engineering analyses, models and simulations, and design and safety regulations. The avalanche of publications, reports, experimental data, computer codes, and regulatory documents related to oxidation behavior of nuclear graphite is now accelerating to new levels, prompted by the increased interest for nuclear energy as a clean, carbon-free energy source. Even though public’s perception of nuclear energy advantages may still be influenced by the memories of past accidents of nuclear reactors from generations II and III, the community of informed scientists and engineers, regulators and statemen knows that generation IV of nuclear reactors is designed at very high safety standards, doubled by great advances of scientific knowledge and technological progress. One of routes of these recent advances is directed at better understanding of graphite oxidation behavior, its relationship with graphite manufacturing and microstructural properties, along with the effects of various environmental factors and process variables. Together, the recent progress in manufacturing, properties characterization, and modeling of intricated physical and chemical processes that concur to the oxidation behavior led to development of powerful simulation codes able to analyze various scenarios of normal operation and hypothetical off-normal events, and thus to clearly specify the allowable parameters envelopes for the designers, constructors, and operators of current and future modular HTGRs. This review begins with an introduction on manufacturing methods, structure, and properties of nuclear graphite, including basic requirements that this specialty graphite type must satisfy for nuclear use. It continues with a chapter on environmental effects on nuclear graphite, where emphasis is placed less on irradiation and much more on oxidation phenomena, their safety implications, and the basic traits of chronic and acute oxidation by air (oxygen) and water (humidity, steam). Particular attention is placed on the three graphite grades of interest for this document (IG-110, NBG-18, PCEA). A chapter on properties degradation induced by oxidation follows, with focus on density, dimensional, and mechanical properties changes. The next chapter is intended as a brief review of various approaches used for modeling of graphite oxidation behavior. It summarizes the progress of oxidation models, from the early attempts to complex computational approaches interfaced with specialized computer codes designed for nuclear reactor simulations. Last, a list is presented of knowledge gaps where more research is needed. A short summary concludes the review.

36 MATERIALS SCIENCE↗

The Impact of Surficial Biochar Treatment on Acute H2S Emissions during Swine Manure Agitation before Pump-Out: Proof-of-the-Concept

Acute releases of hydrogen sulfide (H2S) are of serious concern in agriculture, especially when farmers agitate manure to empty storage pits before land application. Agitation can cause the release of dangerously high H2S concentrations, resulting in human and animal fatalities. To date, there is no proven technology to mitigate these short-term releases of toxic gas from manure. In our previous research, we have shown that biochar, a highly porous carbonaceous material, can float on manure and mitigate gaseous emissions over extended periods (days–weeks). In this research, we aim to test the hypothesis that biochar can mitigate H2S emissions over short periods (minutes–hours) during and shortly after manure agitation. The objective was to conduct proof-of-the-concept experiments simulating the treatment of agitated manure. Two biochars, highly alkaline and porous (HAP, pH 9.2) made from corn stover and red oak (RO, pH 7.5), were tested. Three scenarios (setups): Control (no biochar), 6 mm, and 12 mm thick layers of biochar were surficially-applied to the manure. Each setup experienced 3 min of manure agitation. Real-time concentrations of H2S were measured immediately before, during, and after agitation until the concentration returned to the initial state. The results were compared with those of the Control using the following three metrics: (1) the maximum (peak) flux, (2) total emission from the start of agitation until the concentration stabilized, and (3) the total emission during the 3 min of agitation. The Gompertz’s model for determination of the cumulative H2S emission kinetics was developed. Here, 12 mm HAP biochar treatment reduced the peak (1) by 42.5% (p = 0.125), reduced overall total emission (2) by 17.9% (p = 0.290), and significantly reduced the total emission during 3 min agitation (3) by 70.4%. Further, 6 mm HAP treatment reduced the peak (1) by 60.6%, and significantly reduced overall (2) and 3 min agitation’s (3) total emission by 64.4% and 66.6%, respectively. Moreover, 12 mm RO biochar treatment reduced the peak (1) by 23.6%, and significantly reduced overall (2) and 3 min total (3) emission by 39.3% and 62.4%, respectively. Finally, 6 mm RO treatment significantly reduced the peak (1) by 63%, overall total emission (2) by 84.7%, and total emission during 3 min agitation (3) by 67.4%. Biochar treatments have the potential to reduce the risk of inhalation exposure to H2S. Both 6 and 12 mm biochar treatments reduced the peak H2S concentrations below the General Industrial Peak Limit (OSHA PEL, 50 ppm). The 6 mm biochar treatments reduced the H2S concentrations below the General Industry Ceiling Limit (OSHA PEL, 20 ppm). Research scaling up to larger manure volumes and longer agitation is warranted.

Chen, Baitong (ORCID:0000000266071253)↗

Erythroid cell growth and differentiation in vitro in the simulated microgravity environment of the NASA rotating wall vessel bioreactor

Prolonged exposure of humans and experimental animals to the altered gravitational conditions of space flight has adverse effects on the lymphoid and erythroid hematopoietic systems. Although some information is available regarding the cellular and molecular changes in lymphocytes exposed to microgravity, little is known about the erythroid cellular changes that may underlie the reduction in erythropoiesis and resultant anemia. We now report a reduction in erythroid growth and a profound inhibition of erythropoietin (Epo)-induced differentiation in a ground-based simulated microgravity model system. Rauscher murine erythroleukemia cells were grown either in tissue culture vessels at 1 x g or in the simulated microgravity environment of the NASA-designed rotating wall vessel (RWV) bioreactor. Logarithmic growth was observed under both conditions; however, the doubling time in simulated microgravity was only one-half of that seen at 1 x g. No difference in apoptosis was detected. Induction with Epo at the initiation of the culture resulted in differentiation of approximately 25% of the cells at 1 x g, consistent with our previous observations. In contrast, induction with Epo at the initiation of simulated microgravity resulted in only one-half of this degree of differentiation. Significantly, the growth of cells in simulated microgravity for 24 h prior to Epo induction inhibited the differentiation almost completely. The results suggest that the NASA RWV bioreactor may serve as a suitable ground-based microgravity simulator to model the cellular and molecular changes in erythroid cells observed in true microgravity.

NASA Discipline Cell Biology↗

Pulmonary Toxicity of Simulated Lunar and Martian Dusts Intratracheally Instilled into Mice

The National Aeronautics and Space Administration (NASA) is contemplating sending humans to Mars and to the Moon for further exploration. Equipment designated for these extraterrestrial bases will require testing in simulated Martian or lunar environments. The properties of Hawaiian and San Francisco Mountain volcanic ashes make them suitable to be used in these test environments as Martian and lunar dust simulants, respectively. The present toxicity study was conducted to address NASA's concern about the health risk of dust exposures in the test facilities. In addition, the results obtained on these simulants can be used to design a toxicity study of actual moon dust and Martian dust, which will probably be available in a few years. Respirable portions of lunar soil simulant (LSS) and Martian soil simulant (MSS) were separated from their respective raw materials. These soil simulants, together- with fine titanium dioxide (negative control for fibrogenesis in mice), and crystalline silica (positive control) were each intratracheally instilled in saline to groups of 4 male mice (C57BL/6J, 2-3 months old) at 0.1 mg/mouse (LD) or lmg/mouse (HD). The lungs were harvested 7 or 90 days after the single dust treatment for histopathological examination. Lungs of the LSS-LD groups on either the 7- or 90-day study showed no evidence of inflammation, edema, or fibrosis. Clumps of particles and an increased number of macrophages, visible in the lungs examined after 7 days, were absent after 90 days. The LSS-HD-7d group showed mild to moderate alveolitis with neutrophilic and lymphocytic infiltration, and mild perivascular and peribronchiolar inflammation. The LSS-HD-90d group showed signs of chronic inflammation: septal thickening, mild perivascular and peribronchiolar inflammation, mild alveolitis and some fibrosis. Foci of particle-laden macrophages (PLMs) were still visible. Lungs of the MSS-LD-7d group revealed mild focal intraalveolar inflammation with neutrophilic and lymphocytic infiltration, and mild perivascular and peribronchiolar inflammation. The MSS-LD-90d group showed PLMs and scattered foci of mild fibrosis. The MSS-HD-7d group showed large foci of PLMs, intraalveolar debris, mild to moderate focal alveolitis, and mild to moderate perivascular and peribronchiolar inflammation. The MSS-HD-90d group showed focal chronic mild to moderate alveolitis and fibrosis. To mimic the oxidative and reactive properties of Martian surface dust in the test animals, groups of 4 mice were exposed to ozone (0.5 ppm for 3 hours) prior to instillation of the MSS. Lung lesions in the MSS groups were more severe with the ozone pretreatment. The O3-MSS-HD-90d group had wide spread intraalveolar debris, focal moderate alveolitis and fibrosis. The results for the titanium dioxide and quartz controls were consistent with the known pulmonary toxicity of these compounds. The overall severity of toxic injury to the lungs was TiO2<LSS<MSS<MSS+O3<quartz. In general, the toxic responses increased with the increase of dust burden in the lung. Except for TiO2, the increased duration of dust presence in the lung from 7 to 90 days transformed the acute inflammatory response to a chronic inflammatory lesion.

Lam, Chiu-Wing↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Large Solar-Rejection Filter

NASA utilized Image Intensified Video Cameras for ATV data acquisition from a jet flying at 12.8 km. Afterwards the video was digitized and then analyzed with a modified commercial software package, Image Systems Trackeye. Astrometric results were limited by saturation, plate scale, and imposed linear plate solution based on field reference stars. Time-dependent fragment angular trajectories, velocities, accelerations, and luminosities were derived in each video segment. It was evident that individual fragments behave differently. Photometric accuracy was insufficient to confidently assess correlations between luminosity and fragment spatial behavior (velocity, deceleration). Use of high resolution digital video cameras in future should remedy this shortcoming. A scenically accurate description of matter interpreted as a substance made up of corpuscular constituents was established during the course of the 19th century. In this description, atoms--the building blocks of the matter--form molecules. The properties of the molecules were described by chemistry or thermodynamics depending on what characteristics of the matter were investigated. In both theories, the molecules can dissociate to atoms when the kinetic energies of the atoms exceed the strength of the chemical bonds. The number of atoms is always preserved in a closed system. This is not true, however, when the matter takes up much higher energies at relativistic scales. New particles can be produced at the expense of the kinetic energy. The number of particles is no longer preserved. There are other conserved quantities, however, these quantities, the charge, baryon number, lepton number, are associated with particles that are considered elementary today. The properties and behavior of these elementary particles is the subject of Particle Physics or High Energy Physics. Practice Page: A crewmember touching a positively charged surface was thought to be galvanically isolated from the vehicle ground analogous to a bird on a high voltage power wire. Recent analysis confirms that positive floating potentials, ionospheric currents to the EVA suit, can be hazardous. The analysis is wrong in that the ionospheric plasma itself can close the circuit. Parametric analysis of very low voltage exposures (2 to 15 volts) could cause pain and/or involuntary muscle tetani or spinal cord shock. NASA worked with the Naval Health Research Center Detachment Directed Energy Bioeffects Laboratory to examine the affects electrical hazards could have on extravehicular activity using two models. The results of the two computational models were combined to predict areas of the body in which neurons of different diameters would be excited. They predicted that physiologically active current could be conducted across the crew member causing catastrophic hazards. Future work to analyze additional current paths was proposed. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is 3 times solar, and sulfur is 20 times solar. The FUSE spectrum of BB Dor, observed in a high state, is modeled with an accretion disk with a very low inclination (possibly lower than 10 degrees). Assuming an average WD mass of 0.8 solar mass leads to a distance of the order of approximately 650pc, consistent with the extremely low galactic reddening in its direction, and a mass accretion rate of 10 (exp -9) solar mass a year. The spectrum presents some broad and deep silicon and sulfur absorption lines, indicating that these elements are over-abundant: silicon is times solar, and sulfur is 20 times solar. From its previously observed optical emission lines, P831-57 (WD 0334 6400 or Ret 1 in A Catalog and Atlas of Cataclysmic Variables: Living Edition) has been suspected to contain an accretion disk associated with a companion star in orbit around a subdwarf star with a temperature T is greater than 21,000K. P831-57 has therefore been classified as a nova-like. However, our present observations show it to be a DA + dMe binary. The analysis of its Far Ultraviolet Spectroscopic Explorer (FUSE) spectrum (continuum and lines) reveal an average mass white dwarf (Log(g) approximately equals 7.8 plus or minus 0.1)with a temperature T approximately equals 37,000 plus or minus 500K, an extremely low projected rotational velocity, and a distance of about 115 plus or minus 5pc. The photosphere contains C, N, Si, and S (at about 1% of solar abundances). The dMe star is seen as a flux excess in near-infrared photometry and appears to show occasional flaring of about one magnitude as seen in the Harvard plates. There is no evidence of periodic variability in the spectroscopic or photometric data. We find no evidence of a an accretion disk, instead we find evidence of wind accretion as the stellar carbon abundance (N(C)/N(H) = 2.5 x 10 (exp -6) is about ten times larger than predicted by radiative levitation for such a gravity and temperature. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. The symptoms and threats from acute mountain sickness (AMS) are discussed. The underlying assumptions concerning spacecraft atmosphere mean there is a potential risk to astronauts. The baseline worst case scenario is about 25% based on direct ascent to 8.0 psia with 32% O2. The practical mitigation approach is a staged depressurization scheme. Due to the uncertainty about potential AMS risk the flight surgeon should prepare, focused research should proceed, and current analytical efforts should continue. This slide presentation reviews the threat astronauts face from acute mountain sickness (AMS). The incidence of AMS is highly variable and the risk to astronauts is unclear. However, the potential risk is higher than current EAAs suggest and precautions should be implemented. Due to the uncertain nature of the risk flight surgeons should prepare, and focused research should proceed. Quasiparticle tunneling can be understood at low temperatures using a non-equilibrium kinetic theory. Low-temperature tunneling can be suppressed using existing techniques: island-lead gap engineering, lead cooling with SIN junctions, and quasiparticle traps. The slide presentation reviews the science goals and mission planning for the proposed Jupiter System Observer (JSO). The spacecraft would accommodate 9 instruments making the instrument payload more capable than any previously flown to Jupiter. The would-be mission includes study programs for Jupiter's satellites, interior, magnetosphere and atmosphere. The power needs and solutions for the space exploration and lunar mobility program are discussed. Long term missions in space and on the lunar surface require high energy batteries. Rechargeable batteries for mobility systems and portable utility pallet are needed for successful exploration missions. Nanomaterial usage increases the energy density of the cells apart from increasing the power density. This slide presentation reviews the power requirements for the space exploration and the lunar surface mobility programs. It includes information about the specifications for high energy batteries and the power requirements for lunar rovers,

Roberts, William↗

Syracuse University Test Report On Uptake Factor Resulting From A Dropped Storage Container

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO{sub 3}) was selected in this study to represent relatively heavy powders (7.16 g/cm3 specific gravity for WO{sub 3}). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in{sup 3} (842.7 cm{sup 3}) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft{sup 3} (24.1 m{sup 3}). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can at a height of 8 feet from the bottom of the can to the impacting surface. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours and every 20 seconds thereafter. A test procedure was developed and a total of nine drop tests were performed. In most cases (seven tests), the can tipped over after dropping. The can in Test 1 stayed upright. The can in Test 7 showed a special behavior: after the rebound, it turned upside down and stayed upright. Major findings are summarized below: The amount of spilled powder varied from 0.12 g to 252.35 g and the non-recovered powder varied from 0.11 g to 1.18 g. The corresponding percentage of the spilled powder ranged from 0.01% to 13%;The peak value of particle number concentration after the dropping of the can occurred at approximately 0.9 μm particle size per measured data of individual channels. The peak value of particle mass concentration occurred in the range of 4.3 - 10 μm particle size per grouped data calculated from the measured data with the exception of Test 4 where a different batch powder with unexpectedly different bulk density and particle size distribution; After the dropping of the can, the total airborne mass concentrations ranged from 0.03 to 0.35 mg/m{sup 3}, while the total airborne number concentrations ranged from 2 to 125 #/cm{sup 3} except for Test 4. The number concentration in Test 4 was 1 or 2 orders of magnitude less than those of other tests because the powder was from a different batch. However, its mass concentration was comparable to that in Test 7 because relatively more big airborne particles were detected in Test 4. In general, tests with lid (Test 5, 6, 7 and 8) had smaller concentrations than tests without lid (Test 0, 1, 2, and 3). The influence of lid was not as prominent as the powder (Test 4). However, this needs more tests for verification; The ratio of airborne mass to non-recovered mass ranged from 0.1% to 2%. This means that it is challenging to use this method to check the mass balance, while the uptake factor and associated inhalation exposure can be readily assesse; The calculated cumulative uptake mass within first 10 minutes after the dropping of the can for each test was within the range of 0.002 mg to 0.035 mg. Assuming a breathing rate of 1.2 m{sup 3}/h, the uptake factor during the first 10 minutes was calculated to be between 10{sup -9} and 2×10{sup -8} in reference to the amount loaded; or between 10{sup -8} and 6×10{sup -5} in reference to the amount spilled. The experimental results of this study will be useful for standardizing the test method and provide data for estimating the exposure and associated risk to building occupants in the case of an accidental dropping of heavy powder containers.

42 ENGINEERING↗