Efficient Design in a DC to DC Converter Unit

Space Flight hardware requires high power conversion efficiencies due to limited power availability and weight penalties of cooling systems. The International Space Station (ISS) Electric Power System (EPS) DC-DC Converter Unit (DDCU) power converter is no exception. This paper explores the design methods and tradeoffs that were utilized to accomplish high efficiency in the DDCU. An isolating DC to DC converter was selected for the ISS power system because of requirements for separate primary and secondary grounds and for a well-regulated secondary output voltage derived from a widely varying input voltage. A flyback-current-fed push-pull topology or improved Weinberg circuit was chosen for this converter because of its potential for high efficiency and reliability. To enhance efficiency, a non-dissipative snubber circuit for the very-low-Rds-on Field Effect Transistors (FETs) was utilized, redistributing the energy that could be wasted during the switching cycle of the power FETs. A unique, low-impedance connection system was utilized to improve contact resistance over a bolted connection. For improved consistency in performance and to lower internal wiring inductance and losses a planar bus system is employed. All of these choices contributed to the design of a 6.25 KW regulated dc to dc converter that is 95 percent efficient. The methodology used in the design of this DC to DC Converter Unit may be directly applicable to other systems that require a conservative approach to efficient power conversion and distribution.

Bruemmer, Joel E.↗

Derivation of linearized transfer functions for switching-mode regulations. Phase A: Current step-up and voltage step-up converters

Small-signal models are derived for the power stage of the voltage step-up (boost) and the current step-up (buck) converters. The modeling covers operation in both the continuous-mmf mode and the discontinuous-mmf mode. The power stage in the regulated current step-up converter on board the Dynamics Explorer Satellite is used as an example to illustrate the procedures in obtaining the small-signal functions characterizing a regulated converter.

Wong, R. C.↗

Native lattice strain induced structural earthquake in sodium layered oxide cathodes

Abstract High-voltage operation is essential for the energy and power densities of battery cathode materials, but its stabilization remains a universal challenge. To date, the degradation origin has been mostly attributed to cycling-initiated structural deformation while the effect of native crystallographic defects induced during the sophisticated synthesis process has been significantly overlooked. Here, using in situ synchrotron X-ray probes and advanced transmission electron microscopy to probe the solid-state synthesis and charge/discharge process of sodium layered oxide cathodes, we reveal that quenching-induced native lattice strain plays an overwhelming role in the catastrophic capacity degradation of sodium layered cathodes, which runs counter to conventional perception—phase transition and cathode interfacial reactions. We observe that the spontaneous relaxation of native lattice strain is responsible for the structural earthquake (e.g., dislocation, stacking faults and fragmentation) of sodium layered cathodes during cycling, which is unexpectedly not regulated by the voltage window but is strongly coupled with charge/discharge temperature and rate. Our findings resolve the controversial understanding on the degradation origin of cathode materials and highlight the importance of eliminating intrinsic crystallographic defects to guarantee superior cycling stability at high voltages.

25 ENERGY STORAGE↗

Comparison of Virtual Oscillator and Droop Control: Preprint

Virtual oscillator control and droop control are two techniques that can be used to ensure synchronization and power sharing of parallel inverters in islanded operation. VOC relies on the implementation of non-linear Van der Pol oscillator equations in the control system of the inverter, acting upon the time-domain instantaneous inverter current and terminal voltage. On the other hand, DC explicitly computes active and reactive power produced by the inverter and relies on limited bandwidth low-pass filters. Even though both methods can be engineered to produce the same steady-state characteristics, their dynamic performances are significantly different. This paper presents analytical and experimental results that aim to compare both methods. It is shown that VOC is inherently faster and enables minimizing the circulating currents. The results are verified using three 120V, 1kW inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Selected test results from the LiFeBatt iron phosphate Li-ion battery.

In this paper the performance of the LiFeBatt Li-ion cell was measured using a number of tests including capacity measurements, capacity as a function of temperature, ohmic resistance, spectral impedance, high power partial state of charge (PSOC) pulsed cycling, pulse power measurements, and an over-charge/voltage abuse test. The goal of this work was to evaluate the performance of the iron phosphate Li-ion battery technology for utility applications requiring frequent charges and discharges, such as voltage support, frequency regulation, and wind farm energy smoothing. Test results have indicated that the LiFeBatt battery technology can function up to a 10C{sub 1} discharge rate with minimal energy loss compared to the 1 h discharge rate (1C). The utility PSOC cycle test at up to the 4C{sub 1} pulse rate completed 8,394 PSOC pulsed cycles with a gradual loss in capacity of 10 to 15% depending on how the capacity loss is calculated. The majority of the capacity loss occurred during the initial 2,000 cycles, so it is projected that the LiFeBatt should PSOC cycle well beyond 8,394 cycles with less than 20% capacity loss. The DC ohmic resistance and AC spectral impedance measurements also indicate that there were only very small changes after cycling. Finally, at a 1C charge rate, the over charge/voltage abuse test resulted in the cell venting electrolyte at 110 C after 30 minutes and then open-circuiting at 120 C with no sparks, fire, or voltage across the cell.

17 WIND ENERGY↗

Voltage Control Devices on the IEEE 8500 Node Test Feeder

The IEEE Test Cases provide researchers with distribution system models that can be used to validate new analytic methods. The newest of these models is the 8500-node test feeder which contains multiple devices for voltage control. In addition to a substation regulator there are multiple inline regulators as well as capacitor banks. This paper will discuss the detail in which voltage control devises should be modeled when examining large distribution systems. This discussion will include issues associated with power flow analysis for a single time step as well as for time series analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Selected test results from the neosonic polymer Li-ion battery.

The performance of the Neosonic polymer Li-ion battery was measured using a number of tests including capacity, capacity as a function of temperature, ohmic resistance, spectral impedance, hybrid pulsed power test, utility partial state of charge (PSOC) pulsed cycle test, and an over-charge/voltage abuse test. The goal of this work was to evaluate the performance of the polymer Li-ion battery technology for utility applications requiring frequent charges and discharges, such as voltage support, frequency regulation, wind farm energy smoothing, and solar photovoltaic energy smoothing. Test results have indicated that the Neosonic polymer Li-ion battery technology can provide power levels up to the 10C{sub 1} discharge rate with minimal energy loss compared to the 1 h (1C) discharge rate. Two of the three cells used in the utility PSOC pulsed cycle test completed about 12,000 cycles with only a gradual loss in capacity of 10 and 13%. The third cell experienced a 40% loss in capacity at about 11,000 cycles. The DC ohmic resistance and AC spectral impedance measurements also indicate that there were increases in impedance after cycling, especially for the third cell. Cell No.3 impedance Rs increased significantly along with extensive ballooning of the foil pouch. Finally, at a 1C (10 A) charge rate, the over charge/voltage abuse test with cell confinement similar to a multi cell string resulted in the cell venting hot gases at about 45 C 45 minutes into the test. At 104 minutes into the test the cell voltage spiked to the 12 volt limit and continued out to the end of the test at 151 minutes. In summary, the Neosonic cells performed as expected with good cycle-life and safety.

17 WIND ENERGY↗

Development of Standardized Power Electronic Components, Subsystems, and Systems for Increased Modularity and Scalability

Power electronics devices hold substantial promise for making distributed energy applications more efficient and cost effective. This project is motivated towards developing and testing inverters that will allow distributed energy systems to provide ancillary services such as voltage and VAR regulation, and increased grid reliability by seamlessly transitioning between grid-tied and stand-alone operation modes. The objectives of this project are to identify system integration and optimization issues and technologies and to provide solutions through research, analysis, and testing of power electronic interfaces for distributed energy applications that are cost-competitive and have substantially faster response times than conventional technologies. In addition, the testing of power electronics interfaces will develop a technical basis for performance assessment for distributed energy systems, subsystems, and components that will finally create a foundation for standardized measurements and test procedures. The ultimate goal for this research is to advance the potential benefits of distributed energy to provide ancillary services, enhance power system reliability, and allow customer choice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AI-enabled traveling wave protection for microgrids

Grid forming inverters provide voltage and frequency regulations for microgrids; in the meantime, new challenges are introduced for microgrid protections. For instance, inverters’ control strategies can affect protection behaviors, and low short-circuit ratios and bi-directional power flows also make protection operations complex. Protection schemes based on conventional principles such as overcurrent and distance relays do not always provide reliable, sensitive, or selective operations. Here, we devise a traveling wave protection approach for microgrids using a wavelet-driven deep neural network named WaveletKernelNet (WKN). Compared with conventional methods, the presented approach provides enhanced sensitivity, higher selectivity, and better identification of various faults in microgrids. Extensive case studies validate the efficacy and excellent performance of the devised approach.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

From positive to negative magnetoresistance in graphene with increasing disorder

Artificial disorder was introduced gradually into monolayer graphene by controlling Ga{sup +} ion irradiation and the corresponding electronic transport properties regulated by gate voltage, source-drain voltage, temperature, and magnetic field were studied experimentally. An unsaturated positive magnetoresistance (MR) up to 100% at {approx}5 T was observed in as-fabricated graphene, while there is significant negative MR in disordered graphene. This phenomenon was attributed to the monocrystalline breaking and crystallite-boundary scattering in disordered graphene.

36 MATERIALS SCIENCE↗

Electron-ion collider transverse instabilities due to the crab cavity fundamental impedance

The electron-ion collider crab Cavities will present a significant transverse impedance to the beam. The low-level radio frequency system will have to reduce the crab cavity impedance to prevent transverse instabilities, while regulating the crabbing voltage and minimizing the radio frequency noise levels injected into the beam. This work presents an estimate of the crab cavity impedance in the presence of feedback and the resulting stability margins using simplified stability criteria. Generalized stability criteria are also presented in this work and are used to more accurately estimate stability margins.

43 PARTICLE ACCELERATORS↗

Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid

The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiple Grid-Forming Inverters in Black-Start: The Challenges

Black-start is a major challenge toward the successful operation of an islanded inverter-based system. In this article, the technical challenges for the black-start of multiple grid-forming inverters are reported. Specifically, this article discusses inverter synchronization, voltage and frequency regulation, and power-sharing between the grid-forming inverters. Experiment results from a multi-inverter test-bed have been provided to support the discussion. Furthermore, a grid-forming inverter controller for black-start operation is developed and presented in this article that addresses the discussed technical challenges. The performance of the developed controller in black-start operation is verified through experiment results.

Sadeque, Fahmid↗

System Identification of a DC-DC Buck Converter Based on Two-Channel Relay Method

This work presents a system identification approach based on a two-channel relay applied to a DC-DC buck converter operating in closed-loop with a PI controller to regulate its output voltage. The implemented two-relay method allows system identification while the system is running online. Moreover, the algorithm works in a closed-loop configuration while introducing a minimal perturbation in the converter's operation. The presented algorithm was used to identify the frequency response of the converter with no-prior knowledge about the system structure. Furthermore, the identified transfer function parameters has a good agreement with the mathematical model of the converter. Simulation results of the comparison between the switching model, mathematical model and the identified model are provided to validate the theoretical analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Artificial Intelligence-Driven Management of Sustainable Energy Resources: Visibility, Operation, and Control

The rapid global transition toward sustainable energy resources (SERs) is reshaping how modern power systems are observed, optimized, and controlled. While SERs have significantly advanced decarbonization, their weather dependence, variability, and inverter-dominated characteristics challenge traditional, centralized, and deterministic grid operation. At the same time, the proliferation of high-resolution data from inverters, smart meters, and sensors offers unprecedented visibility into system dynamics. Yet, it also exceeds the analytical capability of conventional model-based approaches. Artificial intelligence (AI) provides a new foundation for addressing these challenges by bridging physical laws with data-driven learning, enabling accurate state awareness, adaptive operation, and coordinated control across distributed assets. This article examines how AI transforms the management of SER-rich power systems along three critical dimensions: 1) enhancing visibility by inferring behind-the-meter (BTM) activities, assessing SER flexibility, and reconstructing system states from sparse or noisy measurements; 2) improving operation through AI-enhanced SER service provision, volt/var control (VVC), and dynamic operating envelopes (DOE) for efficiency and security; and 3) advancing control by embedding learning-based intelligence into inverter coordination, voltage and frequency regulation, and long-term dispatch. Together, these developments reveal how AI can convert the variability of SERs from an operational challenge into a source of flexibility, resilience, and intelligence, paving the way toward sustainable, adaptive, and self-optimizing power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Restoration of Grid-Forming Inverters in Pulse Load and Plug-in Events

This article presents a restoration technique using grid-forming inverters in an islanded microgrid during pulse load and plug-in events. In a microgrid powered by droop-controlled inverters, frequency is the variable that is accessible to all inverters for adjusting their power contributions. The problem is that the microgrid frequency deviates from its nominal value after a load change. The presented method enables the inverters to restore the frequency to the nominal value and regulate their bus voltage amplitudes. The frequency and voltage restorations are performed without communication while achieving the desired power-sharing between grid-forming inverters. The restoration is activated after detecting any active or reactive power changes. In this article, the dynamic model of an inverter equipped with enabled restoration paths is developed to verify the stability of the inverter controller under various conditions. The frequency and voltage restorations are examined during pulse load and plug-in events. Furthermore, this study is performed using a laboratory-scale islanded microgrid powered by two 208 V, 60 Hz, 5 kVA inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Load Diversity and Variability Modeling for Quasi-Static Time-Series Simulation on Distribution Feeders

This paper presents a data-driven load modeling methodology for distribution system quasi-static time-series (QSTS) simulation considering both diversity and variability characteristics of distribution loads. Based on our previous work in [1]-[2], a variability library and diversity library have been established based on the realistic high-resolution data collected from actual utility feeders. Given the load profile for the start-of-circuit load of a feeder, the loads on the feeder nodes can be modeled with both diversity and variability instead of being directly scaled from the substation load profile according to the distribution allocation factors. With diversified load models, the load-induced impact on the feeder operation characteristics, such as voltage ramp and regulator operations, can be better considered in QSTS simulation. The proposed modeling methodology has been tested on both the IEEE 123-bus feeder and an actual utility feeder model, and the simulation results have demonstrated the merits of deploying the proposed load modeling methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Curtailment Associated with PV System Design Considerations

Distributed photovoltaic (PV) systems equipped with advanced inverters can control real and reactive power output based on grid and atmospheric conditions. The Volt-Var control method allows inverters to regulate local grid voltages by producing or consuming reactive power. Based on their power ratings, the inverters may need to curtail real power to meet the reactive power requirements, which decreases their total energy production. To evaluate the expected curtailment associated with Volt-Var control, yearlong quasi-static time-series (QSTS) simulations were conducted on a realistic distribution feeder under a variety of PV system design considerations. Overall, this paper found that the amount of curtailed energy is low (<; 0.55%) compared to the total PV energy production in a year but is affected by several PV system design considerations.