Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visualization algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Visual investigation on the heat dissipation process of a heat sink by using digital holographic interferometry

We present a method for visually and quantitatively investigating the heat dissipation process of plate-fin heat sinks by using digital holographic interferometry. A series of phase change maps reflecting the temperature distribution and variation trend of the air field surrounding heat sink during the heat dissipation process are numerically reconstructed based on double-exposure holographic interferometry. According to the phase unwrapping algorithm and the derived relationship between temperature and phase change of the detection beam, the full-field temperature distributions are quantitatively obtained with a reasonably high measurement accuracy. And then the impact of heat sink's channel width on the heat dissipation performance in the case of natural convection is analyzed. In addition, a comparison between simulation and experiment results is given to verify the reliability of this method. The experiment results certify the feasibility and validity of the presented method in full-field, dynamical, and quantitative measurement of the air field temperature distribution, which provides a basis for analyzing the heat dissipation performance of plate-fin heat sinks.

42 ENGINEERING↗

SU-E-J-120: Comparing 4D CT Computed Ventilation to Lung Function Measured with Hyperpolarized Xenon-129 MRI

Purpose: To correlate ventilation parameters computed from 4D CT to ventilation, profusion, and gas exchange measured with hyperpolarized Xenon-129 MRI for a set of lung cancer patients. Methods: Hyperpolarized Xe-129 MRI lung scans were acquired for lung cancer patients, before and after radiation therapy, measuring ventilation, perfusion, and gas exchange. In the standard clinical workflow, these patients also received 4D CT scans before treatment. Ventilation was computed from 4D CT using deformable image registration (DIR). All phases of the 4D CT scan were registered using a B-spline deformable registration. Ventilation at the voxel level was then computed for each phase based on a Jacobian volume expansion metric, yielding phase sorted ventilation images. Ventilation based upon 4D CT and Xe-129 MRI were co-registered, allowing qualitative visual comparison and qualitative comparison via the Pearson correlation coefficient. Results: Analysis shows a weak correlation between hyperpolarized Xe-129 MRI and 4D CT DIR ventilation, with a Pearson correlation coefficient of 0.17 to 0.22. Further work will refine the DIR parameters to optimize the correlation. The weak correlation could be due to the limitations of 4D CT, registration algorithms, or the Xe-129 MRI imaging. Continued development will refine parameters to optimize correlation. Conclusion: Current analysis yields a minimal correlation between 4D CT DIR and Xe-129 MRI ventilation. Funding provided by the 2014 George Amorino Pilot Grant in Radiation Oncology at the University of Virginia.

60 APPLIED LIFE SCIENCES↗

The ORNL Overhead Vehicle Dataset (OOVD)

Roadways are critical to meeting the mobility and economic needs of the nation. The United States uses 28% of its energy in moving goods and people, with approximately 60% of that utilized by cars, light trucks, and motorcycles. Thus, improved transportation efficiency is vital to America’s economic progress. The increasing congestion and energy resource requirements of transportation systems for metropolitan areas require research in methods to improve and optimize control methods. Coordinating and optimizing traffic in urban areas may introduce hundreds of thousands of vehicles and traffic management systems, which can require high performance computing (HPC) resources to model and manage. This data set was created to understand the potential for machine learning, computer vision, and HPC to improve the energy efficiency aspects of traffic control by leveraging GRIDSMART traffic cameras as sensors for adaptive traffic control, with a sensitivity to the fuel consumption characteristics of the traffic in the camera’s visual field. GRIDSMART cameras—an existing, fielded commercial product—sense the presence of vehicles at intersections and replace more conventional sensors (such as inductive loops) to issue calls to traffic control. These cameras, which have horizon-to-horizon view, offer the potential for an improved view of the traffic environment which can be used to generate better control algorithms.

Karnowski, Thomas P.↗

The CHRONOS mission: capability for sub-hourly synoptic observations of carbon monoxide and methane to quantify emissions and transport of air pollution

The CHRONOS space mission concept provides time-resolved abundance for emissions and transport studies of the highly variable and highly uncertain air pollutants carbon monoxide and methane, with sub-hourly revisit rate at fine (-4 km) horizontal spatial resolution across a North American domain. CHRONOS can provide complete synoptic air pollution maps ("snapshots") of the continental domain with less than 10 min of observations. This rapid mapping enables visualization of air pollution transport simultaneously across the entire continent and enables a sentinel-like capability for monitoring evolving, or unanticipated, air pollution sources in multiple locations at the same time with high temporal resolution. CHRONOS uses a compact imaging gas filter correlation radiometer for these observations, with heritage from more than 17 years of scientific data and algorithm advances by the science teams for the Measurements of Pollution in the Troposphere (MOPITT) instrument on NASA's Terra spacecraft in low Earth orbit. To achieve continental-scale sub-hourly sampling, the CHRONOS mission would be conducted from geostationary orbit, with the instrument hosted on a communications or meteorological platform. CHRONOS observations would contribute to an integrated observing system for atmospheric composition using surface, suborbital and satellite data with atmospheric chemistry models, as defined by the Committee on Earth Observing Satellites. Addressing the U.S. National Academy's 2007 decadal survey direction to characterize diurnal changes in tropospheric composition, CHRONOS observations would find direct societal applications for air quality management and forecasting to protect public health.

54 ENVIRONMENTAL SCIENCES↗

Parallel and Streaming Generation of Ghost Data for Structured Grids

Parallel simulations decompose large domains into many blocks. A fundamental requirement for subsequent parallel analysis and visualization is the presence of ghost data that supplements each block with a layer of adjacent data elements from neighboring blocks. The standard approach for generating ghost data requires all blocks to be in memory at once. This becomes impractical when there are fewer processors - and thus less aggregate memory - available for analysis than for simulation. We describe an algorithm for generating ghost data for structured grids that uses many fewer processors than previously possible. Our algorithm stores as little as one block per processor in memory and can run on as few processors as are available (possibly just one). The key idea is to slightly change the size of the original blocks by declaring parts of them to be ghost data, and by later padding adjacent blocks with this data.

99 GENERAL AND MISCELLANEOUS↗

Comparison of Machine Learning and Deep Learning for View Identification from Cardiac Magnetic Resonance Images

Background: Artificial intelligence is increasingly utilized to aid in the interpretation of cardiac magnetic resonance (CMR) studies. One of the first steps is the identification of the imaging plane depicted, which can be achieved by both deep learning (DL) and classical machine learning (ML) techniques without user input. We aimed to compare the accuracy of ML and DL for CMR view classification and to identify potential pitfalls during training and testing of the algorithms. Methods: To train our DL and ML algorithms, we first established datasets by retrospectively selecting 200 CMR cases. The models were trained using two different cohorts (passively and actively curated) and applied data augmentation to enhance training. Once trained, the models were validated on an external dataset, consisting of 20 cases acquired at another center. We then compared accuracy metrics and applied class activation mapping (CAM) to visualize DL model performance. Results: The DL and ML models trained with the passively-curated CMR cohort were 99.1% and 99.3% accurate on the validation set, respectively. However, when tested on the CMR cases with complex anatomy, both models performed poorly. After training and testing our models again on all 200 cases (active cohort), validation on the external dataset resulted in 95% and 90% accuracy, respectively. The CAM analysis depicted heat maps that demonstrated the importance of carefully curating the datasets to be used for training. Conclusions: Both DL and ML models can accurately classify CMR images, but DL outperformed ML when classifying images with complex heart anatomy.

artificial intelligence↗

SU-E-T-362: Automatic Catheter Reconstruction of Flap Applicators in HDR Surface Brachytherapy

Purpose: Catheter reconstruction is crucial for the accurate delivery of radiation dose in HDR brachytherapy. The process becomes complicated and time-consuming for large superficial clinical targets with a complex topology. A novel method for the automatic catheter reconstruction of flap applicators is proposed in this study. Methods: We have developed a program package capable of image manipulation, using C++class libraries of The-Visualization-Toolkit(VTK) software system. The workflow for automatic catheter reconstruction is: a)an anchor point is placed in 3D or in the axial view of the first slice at the tip of the first, last and middle points for the curved surface; b)similar points are placed on the last slice of the image set; c)the surface detection algorithm automatically registers the points to the images and applies the surface reconstruction filter; d)then a structured grid surface is generated through the center of the treatment catheters placed at a distance of 5mm from the patient's skin. As a result, a mesh-style plane is generated with the reconstructed catheters placed 10mm apart. To demonstrate automatic catheter reconstruction, we used CT images of patients diagnosed with cutaneous T-cell-lymphoma and imaged with Freiburg-Flap-Applicators (Nucletron™-Elekta, Netherlands). The coordinates for each catheter were generated and compared to the control points selected during the manual reconstruction for 16catheters and 368control point Results: The variation of the catheter tip positions between the automatically and manually reconstructed catheters was 0.17mm(SD=0.23mm). The position difference between the manually selected catheter control points and the corresponding points obtained automatically was 0.17mm in the x-direction (SD=0.23mm), 0.13mm in the y-direction (SD=0.22mm), and 0.14mm in the z-direction (SD=0.24mm). Conclusion: This study shows the feasibility of the automatic catheter reconstruction of flap applicators with a high level of positioning accuracy. Implementation of this technique has potential to decrease the planning time and may improve overall quality in superficial brachytherapy.

60 APPLIED LIFE SCIENCES↗

Density-Equalizing Maps for Simply Connected Open Surfaces

Here in this paper, we are concerned with the problem of creating flattening maps of simply connected open surfaces in $\mathbb{R}^3$. Using a natural principle of density diffusion in physics, we propose an effective algorithm for computing density-equalizing maps with any prescribed density distribution. By varying the initial density distribution, a large variety of flattening maps with different properties can be achieved. For instance, area-preserving parameterizations of simply connected open surfaces can be easily computed. Experimental results are presented to demonstrate the effectiveness of our proposed method. Applications to data visualization and surface remeshing are explored.

97 MATHEMATICS AND COMPUTING↗

A Unified Data-Driven Approach for Programming In Situ Analysis and Visualization Final Scientific/Technical Report

The goal of Kitware’s work has been the study of a unified data-driven approach for programming applications and in situ analysis and visualization. We have especially focused on understanding the interplay between data-centric programming model requirements at extreme-scale and the overall impact of those requirements on the design, capabilities, flexibility, and implementation details for both applications and the supporting in situ infrastructure. We have successfully demonstrated the use of pipeline abstractions within Legion and developed a number of algorithms that were integrated within the Legion simulation framework. This report focuses on describing milestones, mainly those focusing on exploring pipeline abstractions in the context of the Legion programming model.

97 MATHEMATICS AND COMPUTING↗

Grid Modernization of Cooperatives and Municipal Utilities via Breakthrough System Monitoring, Control and Optimization (CRADA Final Report)

This project aims at developing and demonstrating successful implementation of breakthrough approaches in real-time data visualization as well as real-time distributed DER control and optimization to provide ample benefits to both utilities and end users. The National Renewable Energy Laboratory (NREL), Holy Cross Energy (HCE), National Rural Electric Cooperative Association (NRECA) and Survalent are collaborating to enable Cooperative and Municipal utilities to fully leverage DERs as part of their strategies for providing safe, reliable, and affordable electric services to their customers and help meet DOE Grid modernization goal of achieving at least 10% active devices to provide grid flexibility by 2035. This project will use novel real-time control algorithms and approaches for distributed control recently developed under DOE-funded projects, using the date from the Survalent’s basic SCADA engine, GIS and AMI engines deployed at HCE combined with NRECA’s globally-used MultiSpeak(R) software interoperability specification for seamless and real-time communications between electric utility enterprise software to embrace DER as part of their strategies for providing safe, reliable and affordable electric service to their customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-driven selection and spectral classification of white dwarf stars

The next generation of spectroscopic surveys is expected to provide spectra for hundreds of thousands of white dwarf (WD) candidates in the upcoming years. Currently, spectroscopic classification of white dwarfs is mostly done by visual inspection, requiring substantial amounts of expert attention. We propose a data-driven pipeline for fast, automatic selection, and spectroscopic classification of WD candidates, trained using spectroscopically confirmed objects with available Gaia astrometry, photometry, and Sloan Digital Sky Survey (SDSS) spectra with signal-to-noise ratios ≥9. The pipeline selects WD candidates with improved accuracy and completeness over existing algorithms, classifies their primary spectroscopic type with ≥ 90 % accuracy, and spectroscopically detects main sequence companions with similar performance. We apply our pipeline to the Gaia Data Release 3 cross-matched with the SDSS Data Release 17 (DR17), identifying 424 096 high-confidence WD candidates and providing the first catalogue of automated and quantifiable classification for 36 523 WD spectra. Both the catalogue and pipeline are made available online. Such a tool will prove particularly useful for the undergoing SDSS-V survey, allowing for rapid classification of thousands of spectra at every data release.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative Monte Carlo-based holmium-166 SPECT reconstruction

Purpose: Quantitative imaging of the radionuclide distribution is of increasing interest for microsphere radioembolization (RE) of liver malignancies, to aid treatment planning and dosimetry. For this purpose, holmium-166 ({sup 166}Ho) microspheres have been developed, which can be visualized with a gamma camera. The objective of this work is to develop and evaluate a new reconstruction method for quantitative {sup 166}Ho SPECT, including Monte Carlo-based modeling of photon contributions from the full energy spectrum.Methods: A fast Monte Carlo (MC) simulator was developed for simulation of {sup 166}Ho projection images and incorporated in a statistical reconstruction algorithm (SPECT-fMC). Photon scatter and attenuation for all photons sampled from the full {sup 166}Ho energy spectrum were modeled during reconstruction by Monte Carlo simulations. The energy- and distance-dependent collimator-detector response was modeled using precalculated convolution kernels. Phantom experiments were performed to quantitatively evaluate image contrast, image noise, count errors, and activity recovery coefficients (ARCs) of SPECT-fMC in comparison with those of an energy window-based method for correction of down-scattered high-energy photons (SPECT-DSW) and a previously presented hybrid method that combines MC simulation of photopeak scatter with energy window-based estimation of down-scattered high-energy contributions (SPECT-ppMC+DSW). Additionally, the impact of SPECT-fMC on whole-body recovered activities (A{sup est}) and estimated radiation absorbed doses was evaluated using clinical SPECT data of six {sup 166}Ho RE patients.Results: At the same noise level, SPECT-fMC images showed substantially higher contrast than SPECT-DSW and SPECT-ppMC+DSW in spheres ≥17 mm in diameter. The count error was reduced from 29% (SPECT-DSW) and 25% (SPECT-ppMC+DSW) to 12% (SPECT-fMC). ARCs in five spherical volumes of 1.96–106.21 ml were improved from 32%–63% (SPECT-DSW) and 50%–80% (SPECT-ppMC+DSW) to 76%–103% (SPECT-fMC). Furthermore, SPECT-fMC recovered whole-body activities were most accurate (A{sup est}= 1.06 × A − 5.90 MBq, R{sup 2}= 0.97) and SPECT-fMC tumor absorbed doses were significantly higher than with SPECT-DSW (p = 0.031) and SPECT-ppMC+DSW (p = 0.031).Conclusions: The quantitative accuracy of {sup 166}Ho SPECT is improved by Monte Carlo-based modeling of the image degrading factors. Consequently, the proposed reconstruction method enables accurate estimation of the radiation absorbed dose in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Compilation and Validation of the Spectroscopic Redshift Catalogs for the DESI-COSMOS and DESI-XMM-LSS Fields

Over several dedicated programs that include targets beyond the main cosmological samples, the Dark Energy Spectroscopic Instrument collected spectra for 304,970 unique objects in two fields centered on the COSMOS and XMM-LSS fields. In this work, we develop spectroscopic redshift robustness criteria for those spectra, validate these criteria using visual inspection, and provide two custom value-added catalogs with our redshift characterizations. With these criteria, we reliably classify 212,935 galaxies below z < 1.6, 9713 quasars, and 35,222 stars. The resulting catalogs achieve a redshift purity exceeding 99.4% across all galaxy samples. As a critical element in characterizing the selection function, we provide the description of 70 different algorithms that were used to select these targets from imaging data. To facilitate joint imaging/spectroscopic analyses, we provide row-matched photometry from the Dark Energy Camera, Hyper-Suprime Cam, and public COSMOS2020 photometric catalogs. Finally, we demonstrate example applications of these large catalogs to photometric redshift estimation, cluster finding, and completeness studies.

Ratajczak, J. [Univ. of Utah, Salt Lake City, UT (↗

A dual-view digital tomosynthesis imaging technique for improved chest imaging

Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images. Results: Both the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there. Conclusions: The authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

60 APPLIED LIFE SCIENCES↗

NMR_DIFFSIM v. 1.0

The software generates and analyzes nuclear magnetic resonance spin diffusion simulations for the purpose of measuring domain sizes or spin diffusion constants in a heterogenous sample. Its primary capabilities are: 1. It solves the spin magnetization diffusion equation to simulate the results of a spin diffusion experiment using any structural input geometry, including structure models generated by molecular dynamics or other computational or experimental methods. 2. It compares the results of simulations on an input structure to experimental data, providing a data fitting algorithm to extract physical information from the experimental data via the simulation. 3. It can provide statistical measures to compare correlations between structural models, to determine domain clustering and connectedness, and to provide goodness-of-fit measures including chord length distributions, chi-squared values, Pearson coefficients and pair correlation functions. 4. It provides output reports, data files, and movies to visualize simulation results.

Sorte, Eric↗

BD-CATS-IO

Modern cosmology and plasma physics codes are now capable of simulating trillions of particles on petascale systems. Each timestep output from such simulations is on the order of 10s of TBs. Summarizing and visualizing raw particle data is challenging, and scientists often focus on density structures, whether in the real 3D space, or a high-dimensional phase space. In this work, code was developed for reading 10s of terabytes of data and for writing the resultant cluster IDs for each particle. This code will be part of a highly scalable version of the clustering algorithm DBSCAN, and apply it to the largest datasets produced by state-of-the-art codes. The overall function of BD-CATS (Big Data Clustering at Trillion Particles Scale) is to perform end-to-end analysis: loading the data, dynamic partitioning, computing kdtrees, performing clustering analysis, and storing the results. BD-CATS-IO provides the functionality of loading the data and storing the results.

Byna, Surendra↗

An apparatus for generation and quantitative measurement of homogeneous isotropic turbulence in He ii

The superfluid phase of helium-4, known as He ii, exhibits extremely small kinematic viscosity and may be a useful tool for economically producing and studying high Reynolds number turbulent flow. Such applications are not currently possible because a comprehensive understanding of the complex two-fluid behavior of He ii is lacking. This situation could be remedied by a systematic investigation of simple, well controlled turbulence that can be directly compared with theoretical models. To this end, we have developed a new apparatus that combines flow visualization with second sound attenuation to study turbulence in the wake of a mesh grid towed through a He ii filled channel. One of three mesh grids (mesh number M = 3, 3.75, or 5 mm) can be pulled at speeds between 0.1 and 60 cm/s through a cast acrylic flow channel which has a 16 mm × 16 mm cross section and measures 330 mm long. The motion of solidified deuterium tracer particles, with diameter of the order 1 μm, in the resulting flow is captured by a high speed camera, and a particle tracking velocimetry algorithm resolves the Lagrangian particle trajectories through the turbulent flow field. A pair of oscillating superleak second sound transducers installed in the channel allows complementary measurement of vortex line density in the superfluid throughout the turbulent decay process. Here, success in early experiments demonstrates the effectiveness of both probes, and preliminary analysis of the data shows that both measurements strongly correlate with each other. Further investigations will provide comprehensive information that can be used to address open questions about turbulence in He ii and move toward the application of this fluid to high Reynolds number fluid research

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PDB-IHM: A System for Deposition, Curation, Validation, and Dissemination of Integrative Structures

Structures of many large biomolecular assemblies are now being determined using integrative approaches. In these approaches, information derived from multiple experimental and computational methods is combined to compute three-dimensional structures of multi-protein complexes and other macromolecular machines. A standalone prototype data resource for integrative structures called PDB-Dev was built, based on recommendations of the Integrative and Hybrid Methods (IHM) Task Force of the Worldwide Protein Data Bank (wwPDB). This effort included developing data standards and software tools for collecting, curating, validating, visualizing, archiving, and disseminating integrative structures that span diverse spatiotemporal scales and conformational states. Mechanisms have been created to validate integrative structures based on the experimental data underpinning them. Building upon this foundational framework, PDB-Dev has been further expanded to handle large dynamic macromolecular systems and integrative structures that combine, for example, experimental restraints with atomic coordinates computed by machine learning algorithms. Data standards and supporting tools have also been extended to capture information about biomolecular dynamics, such as conformational transitions and related kinetic data derived from biophysical methods. Recently, PDB-Dev was unified with the PDB archive and rebranded as PDB-IHM (pdb-ihm.org), further promoting FAIR (Findable, Accessible, Interoperable, and Reusable) principles of data stewardship for integrative structural biology.

IHMCIF↗