Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

Risk-informed Graded Approach for Reliability and Performance Assessment of Machine Learning and Artificial Intelligence for Advanced Condition Monitoring Techniques

With the shift away from time-based maintenance and toward condition-based maintenance, and to reduce overall maintenance costs, there has been an upsurge in the usage and development of advanced condition monitoring (ACM) techniques for real-time monitoring of nuclear power plant (NPP) components. ACM is particularly useful in the development of digital twins, which are designed to predict the failure or degradation of plant components. Successful implementation of ACM requires an assessment to inform the development of a risk-informed approach to evaluate the use of ACM to meet Nuclear Regulatory Committee (NRC) regulations for in-service testing (IST) programs. This includes the monitoring and diagnostics of reactor components and systems in current, new, and advanced reactors. A key component in ACM is the usage of machine learning (ML) and artificial intelligence (AI) algorithms that can employ real-time data from instrumentation and sensors to detect and predict reactor component degradations. Such predictive capabilities enable early detection of component degradation so as to help plant personnel plan and execute necessary maintenance. For successful implementation of ML/AI in ACM such that regulatory requirements are met, a risk-informed graded approach is needed to assess the reliability and performance of ML/AI for ACM. The American Society for Mechanical Engineers (ASME) developed their Operations and Maintenance (O&M) Code to provide guidance on safe, reliable O&M of NPPs. The IST section of the O&M Code specifically establishes requirements for IST and examination to gauge operational readiness of components in water-cooled NPPs. This paper presents a state-of-the-art review of how reliability and risk assessment can be integrated with ACM to assess component performance by non-nuclear industries. This is followed by different methodologies and approaches for conducting performance and reliability assessments so as to meet IST requirements for NPP components.

97 - MATHEMATICS AND COMPUTING↗

Risk-informed Graded Approach for Reliability and Performance Assessment for Advanced Condition Monitoring Techniques

With the shift away from time-based maintenance and toward condition-based maintenance, and to reduce overall maintenance costs, there has been an upsurge in the usage and development of advanced condition monitoring (ACM) techniques for real-time monitoring of nuclear power plant (NPP) components. ACM is particularly useful in the development of digital twins, which are designed to predict the failure or degradation of plant components. Successful implementation of ACM requires an assessment to inform the development of a risk-informed approach to evaluate the use of ACM to meet Nuclear Regulatory Committee (NRC) regulations for in-service testing (IST) programs. This includes the monitoring and diagnostics of reactor components and systems in current, new, and advanced reactors. A key component in ACM is the usage of machine learning (ML) and artificial intelligence (AI) algorithms that can employ real-time data from instrumentation and sensors to detect and predict reactor component degradations. Such predictive capabilities enable early detection of component degradation so as to help plant personnel plan and execute necessary maintenance. For successful implementation of ML/AI in ACM such that regulatory requirements are met, a risk-informed graded approach is needed to assess the reliability and performance of ML/AI for ACM. The American Society for Mechanical Engineers (ASME) developed their Operations and Maintenance (O&M) Code to provide guidance on safe, reliable O&M of NPPs. The IST section of the O&M Code specifically establishes requirements for IST and examination to gauge operational readiness of components in water-cooled NPPs. This paper presents a state-of-the-art review of how reliability and risk assessment can be integrated with ACM to assess component performance by non-nuclear industries. This is followed by different methodologies and approaches for conducting performance and reliability assessments so as to meet IST requirements for NPP components.

99 - GENERAL AND MISCELLANEOUS↗

Database Performance Monitoring for DUNE

This report presents the research, design, and implementation of improved PostgreSQL monitoring for DUNE Rucio database services using Checkmk. The project began with a request to improve dashboard visibility for database performance metrics, including connection usage, configured connection limits, lock activity, wait behavior, storage trends, query performance, and saturation alerts. The initial implementation focused on the dune_rucio_prod database on the rucio_prod PostgreSQL instance because connection saturation and lock contention are direct reliability risks for database-backed services. Existing Checkmk PostgreSQL monitoring was investigated, and several gaps were identified. Built-in connection monitoring did not clearly separate active, idle, idle-in-transaction, total, and usage-percent metrics, while the built-in lock monitoring simplified PostgreSQL lock modes into shared and exclusive categories. To address these gaps, two DSG-specific Checkmk local checks were created: one for connection-state monitoring and one for lock-state monitoring. These checks supplement the built-in PostgreSQL checks and provide additional performance data for dashboard graphs, service states, and alerts.

Bowers, Elliot [Cabrillo Coll.]↗

Scalable High Performance Message Passing over InfiniBand for Open MPI

InfiniBand (IB) is a popular network technology for modern high-performance computing systems. MPI implementations traditionally support IB using a reliable, connection-oriented (RC) transport. However, per-process resource usage that grows linearly with the number of processes, makes this approach prohibitive for large-scale systems. IB provides an alternative in the form of a connectionless unreliable datagram transport (UD), which allows for near-constant resource usage and initialization overhead as the process count increases. This paper describes a UD-based implementation for IB in Open MPI as a scalable alternative to existing RC-based schemes. We use the software reliability capabilities of Open MPI to provide the guaranteed delivery semantics required by MPI. Results show that UD not only requires fewer resources at scale, but also allows for shorter MPI startup times. A connectionless model also improves performance for applications that tend to send small messages to many different processes.

99 GENERAL AND MISCELLANEOUS↗

Information Resources in High-Energy Physics: Surveying the Present Landscape and Charting the Future Course

Access to previous results is of paramount importance in the scientific process. Recent progress in information management focuses on building e-infrastructures for the optimization of the research workflow, through both policy-driven and user-pulled dynamics. For decades, High-Energy Physics (HEP) has pioneered innovative solutions in the field of information management and dissemination. In light of a transforming information environment, it is important to assess the current usage of information resources by researchers and HEP provides a unique test-bed for this assessment. A survey of about 10% of practitioners in the field reveals usage trends and information needs. Community-based services, such as the pioneering arXiv and SPIRES systems, largely answer the need of the scientists, with a limited but increasing fraction of younger users relying on Google. Commercial services offered by publishers or database vendors are essentially unused in the field. The survey offers an insight into the most important features that users require to optimize their research workflow. These results inform the future evolution of information management in HEP and, as these researchers are traditionally 'early adopters' of innovation in scholarly communication, can inspire developments of disciplinary repositories serving other communities.

99 GENERAL AND MISCELLANEOUS↗

Analysis of the Current Use, Benefit, and Value of the Open Science Grid

The Open Science Grid usage has ramped up more than 25% in the past twelve months due to both the increase in throughput of the core stakeholders - US LHC, LIGO and Run II - and increase in usage by nonphysics communities. It is important to understand the value collaborative projects, such as the OSG, contribute to the scientific community. This needs to be cognizant of the environment of commercial cloud offerings, the evolving and maturing middleware for grid based distributed computing, and the evolution in science and research dependence on computation. We present a first categorization of OSG value and analysis across several different aspects of the Consortium's goals and activities. And lastly, we presents some of the upcoming challenges of LHC data analysis ramp up and our ongoing contributions to the World Wide LHC Computing Grid.

99 GENERAL AND MISCELLANEOUS↗

Energy Efficient and Sustainable HPC at Pacific Northwest National Laboratory

Power consumption in US data centers has been escalating at an alarming rate. In response to Public Law 109-431, EPA reported that electricity usage by US data centers accounted for 1.5% of the total electricity used in the US in 2006. They projected that if current data center operating practices continue, electricity usage will almost double to 2.9% of the total electricity used in the US in 2011 (EPA, 2007). Consequently EPA issued a call to action to both government and industry to collaborate and set aggressive goals to reduce power consumption in data centers. In the spirit of responding to the findings and recommendations of the EPA report, the Pacific Northwest National Laboratory (PNNL) has teamed with several key organizations including: The Green Grid (TGG), ASHRAE TC9.9, IBM, 3M, and SprayCool. As part of this effort, a highly instrumented liquid-cooled cluster has been installed at PNNL. The cluster is housed in an 800 ft2 data center which resides in a mixed-use data center with a significant amount of instrumentation as well. The eventual objective of the effort is to be able to report the real-time power consumption, energy efficiency, and productivity of the liquid-cooled data center. Preliminary results from the effort at PNNL are reported in this paper. Thermal results are reported for the hottest server components, including the microprocessors and memory DIMMs. Under all conditions tested, the components have not exceeded manufacturers’ specifications. More importantly, the data show that the liquid-cooled servers can be maintained within specifications while rejecting to non-chilled facility water at 78°F (25.6°C). Furthermore, a reasonable extrapolation suggests that the specifications can still be maintained at 86°F (30°C). In an effort to address global warming, work has started on the qualification of a new 3M Fluoroketone fluid that has a Global Warming Potential (GWP) of 1. This GWP is the lowest published value of all commercially available coolants. Details are provided in the body of this paper.

54 ENVIRONMENTAL SCIENCES↗

Monitoring applications once they are in the user community

Once an application is released into the user community, obtaining prompt and high quality information on application usage, applicability and reliability can be a challenge. Most Linux and Solaris applications used at RHIC and associated accelerators have been instrumented so that application and crash information is gathered, stored and forwarded to the appropriate developer for immediate analysis. To support this process, databases were created to track developer and application information. In order to keep these databases relevant, a web based application release procedure was created to collect information and automatically update the database. Additional capabilities have been developed that utilize and expand on the various components of this system to promote communication between developers and users, and to monitor applications. An application feedback feature allows users to instantly communicate with application developers. An application history system records application usage and reliability.

43 PARTICLE ACCELERATORS↗

Data Network Equipment Energy Use and Savings Potential in Buildings

Network connectivity has become nearly ubiquitous, and the energy use of the equipment required for this connectivity is growing. Network equipment consists of devices that primarily switch and route Internet Protocol (IP) packets from a source to a destination, and this category specifically excludes edge devices like PCs, servers and other sources and sinks of IP traffic. This paper presents the results of a study of network equipment energy use and includes case studies of networks in a campus, a medium commercial building, and a typical home. The total energy use of network equipment is the product of the stock of equipment in use, the power of each device, and their usage patterns. This information was gathered from market research reports, broadband market penetration studies, field metering, and interviews with network administrators and service providers. We estimate that network equipment in the USA used 18 TWh, or about 1percent of building electricity, in 2008 and that consumption is expected to grow at roughly 6percent per year to 23 TWh in 2012; world usage in 2008 was 51 TWh. This study shows that office building network switches and residential equipment are the two largest categories of energy use consuming 40percent and 30percent of the total respectively. We estimate potential energy savings for different scenarios using forecasts of equipment stock and energy use, and savings estimates range from 20percent to 50percent based on full market penetration of efficient technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Electron Efficiency in an X-ray Diode

The goal for this research is to optimize the XRD structure and usage configurations and increase the efficiency of the XRD. This research was successful in optimizing the XRD structure and usage configurations, thus creating a high efficiency XRD. Best efficiency occurs when there is an angle between the photocathode and incident X-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculating system reliability with SRFYDO

SRFYDO is a process for estimating reliability of complex systems. Using information from all applicable sources, including full-system (flight) data, component test data, and expert (engineering) judgment, SRFYDO produces reliability estimates and predictions. It is appropriate for series systems with possibly several versions of the system which share some common components. It models reliability as a function of age and up to 2 other lifecycle (usage) covariates. Initial output from its Exploratory Data Analysis mode consists of plots and numerical summaries so that the user can check data entry and model assumptions, and help determine a final form for the system model. The System Reliability mode runs a complete reliability calculation using Bayesian methodology. This mode produces results that estimate reliability at the component, sub-system, and system level. The results include estimates of uncertainty, and can predict reliability at some not-too-distant time in the future. This paper presents an overview of the underlying statistical model for the analysis, discusses model assumptions, and demonstrates usage of SRFYDO.

97 MATHEMATICS AND COMPUTING↗

Variability and Diversity Load Model Tool [SWR-20-03]

The motivation for the development of this tool and the underlying algorithms and methods was to enable the development of high-temporal resolution, realistic time-series data for quasi-static time-series (QSTS) analysis of distribution systems. Often, aggregated load profile data for a distribution circuit is available (e.g. feeder loading data collected via SCADA at the utility substation) and, while this data is typically accurate it masks the considerable variability of the 100’s or 1000’s of individual loads connected on the circuit. This tool was developed to model both the increased variability expected for these individual loads (e.g. the load of a single distribution transformer connected to 8-12 houses) and the expected diversity between loads on the circuit. It is important to note that the difference in variability and diversity, in the context of this tool, is that variability modeling only adds representative variability due to disaggregated load characteristics (e.g. the presence in the load profile of loads turning off and on like an air conditioner/oven) while the average energy profile remains the same as the user supplied power profile. Diversity modeling generates multiple individual load profiles which, in aggregate, sum to the user supplied power profile. Diversity is effectively variability in the energy usage over longer periods of time than seen in the variability model. Put another way, variability modeling supplies the expected variability due to the operation of various end-use loads and diversity modeling supplies the usage differences due to human behavior, schedules, etc. This load modeling tool was developed for use in generating data for distribution systems. Modeling is summarized by two major functions: 1) taking low resolution load profiles and adding intra-seconds variability onto the profiles, and 2) taking a user supplied load profile and distribution factors and adding both diversity and variability to the user supplied profile.

Zhu, Xiangqi↗

Representing heterogeneity in structural relationships among multiple choice variables using a latent segmentation approach

Travel model systems often adopt a single decision structure that links several activity-travel choices together. The single decision structure is then used to predict activity-travel choices, with those downstream in the decision-making chain influenced by those upstream in the sequence. The adoption of a singular sequential causal structure to depict relationships among activity-travel choices in travel demand model systems ignores the possibility that some choices are made jointly as a bundle as well as the possible presence of structural heterogeneity in the population with respect to decision-making processes. As different segments in the population may adopt and follow different causal decision-making mechanisms when making selected choices jointly, it would be of value to develop simultaneous equations model systems relating multiple endogenous choice variables that are able to identify population subgroups following alternative causal decision structures. Because the segments are not known a priori, they are considered latent and determined endogenously within a joint modeling framework proposed in this paper. The methodology is applied to a national mobility survey data set to identify population segments that follow different causal structures relating residential location choice, vehicle ownership, and car-share and mobility service usage. It is found that the model revealing three distinct latent segments best describes the data, confirming the efficacy of the modeling approach and the existence of structural heterogeneity in decision-making in the population. Future versions of activity-travel model systems should strive to incorporate such structural heterogeneity to better reflect varying decision processes across population subgroups.

30 DIRECT ENERGY CONVERSION↗

Performance assessment of 700-bar compressed hydrogen storage for light duty fuel cell vehicles

In this study, type 4 700-bar compressed hydrogen storage tanks were modeled using ABAQUS. The finite element model was first calibrated against data for 35-L subscale test tanks to obtain the composite translation efficiency, and then applied to full sized tanks. Two variations of the baseline T700/epoxy composite were considered in which the epoxy was replaced with a low cost vinyl ester resin and low cost resin with an alternate sizing. The results showed that the reduction in composite weight was attributed primarily to the lower density of the resin and higher fiber volume fraction in the composite due to increased squeeze-out with the lower viscosity vinyl ester resin. The system gravimetric and volumetric capacities for the onboard storage system that holds 5.6 kg H 2 are 4.2 wt% (1.40 kWh/kg) and 24.4 g-H 2 /L (0.81 kWh/L), respectively. The system capacities increase and carbon fiber requirement decreases if the in-tank amount of unrecoverable hydrogen is reduced by lowering the tank "empty" pressure. Models of an alternate tank design showed potential 4-7% saving in composite usage for tanks with a length-to-diameter (L/D) ratio of 2.8-3.0 but no saving for L/D of 1.7. Lastly, a boss with smaller opening and longer flange does not appear to reduce the amount of helical windings.

08 HYDROGEN↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting industrial building energy consumption with statistical and machine-learning models informed by physical system parameters

The industrial sector consumes about one-third of global energy, making them a frequent target for energy use reduction. Variation in energy usage is observed with weather conditions, as space conditioning needs to change seasonally, and with production, energy-using equipment is directly tied to production rate. Previous models were based on engineering analyses of equipment and relied on site-specific details. Others consisted of single-variable regressors that did not capture all contributions to energy consumption. Further, new modeling techniques could be applied to rectify these weaknesses. Applying data from 45 different manufacturing plants obtained from industrial energy audits, a supervised machine-learning model is developed to create a general predictor for industrial building energy consumption. The model uses features of air enthalpy, solar radiation, and wind speed to predict weather-dependency; motor, steam, and compressed air system parameters to capture support equipment contributions; and operating schedule, production rate, number of employees, and floor area to determine production-dependency. Results showed that a model that used a linear regressor over a transformed feature space could outperform a support vector machine and utilize features more representative of physical systems. Using informed parameters to build a reliable predictor will more accurately characterize a manufacturing facility's energy savings opportunities.