Ultrasonic wave propagation loss factor in composite in terms of constituent properties

A model is developed to relate the energy loss factors of ultrasonic longitudinal waves propagating in the principal directions of a unidirectional graphite fiber composite to the composite constituent properties. All the constituents are assumed to behave as linear viscoelastic materials with energy dissipation properties defined by loss factors. It is found that by introducing a new constituent called the interface material, the composite and constituent properties can be brought into consistency with simple series and parallel models. An expression relating the composite loss factors to the loss factors of the constituents is derived and its coefficients are evaluated.

Williams, J. H., Jr.↗

The use of ultrasonic spectroscopy to characterize calcified lesions

A quantitative basis is developed for the medical application of ultrasonic spectroscopy, particularly in the characterization of calcified lesions associated with atherosclerotic conditions. A theory of the field radiation patterns of disk and ring sources is presented which can be used to predict minima in the reflection spectra of a target as a function of frequency and angle relative to the acoustic axis. The theory is then tested experimentally for objects of known geometry by the use of a time delay spectroscopy system using a swept frequency technique, and results are obtained which demonstrate the usefulness of the technique. Finally, the theory is verified in the determination of lesion diameter and orientation from spectra received from calcified lesions on in vitro arterial specimens as a function of angle.

Rooney, J. A.↗

Stress-wave attenuation in thin structures by ultrasonic through-transmission

The steady-state amplitude of the output of an ultrasonic through-transmission measurement is analyzed and the result is given in closed form. Provided that the product of the input and output transduction ratios, the specimen-transducer reflection coefficient, the specimen-transducer phase-shift parameter, and the material phase velocity are known, this analysis gives a means for determining the through-thickness attenuation of an individual thin sample. Multiple stress-wave reflections are taken into account, and so signal echoes do not represent a difficulty. An example is presented for a graphite fiber epoxy composite (Hercules AS/3501-6). Thus, the technique provides a direct method for continuous or intermittent monitoring of through-thickness attenuation of plate structures which may be subject to service structural degradation.

Lee, S. S.↗

Improved formula for continuous-wave measurements of ultrasonic phase velocity

An improved formula for continuous-wave ultrasonic phase velocity measurements using contact transducers is derived from the transmission line theory. The effect of transducer-sample coupling bonds is considered for measurements of solid samples even though it is often neglected because of the difficulty of accurately determining the bond thickness. Computer models show that the present formula is more accurate than previous expressions. Laboratory measurements using contacting transducers with the present formula are compared to measurements using noncontacting (hence effectively correction-free) capacitive transducers. The results of the experiments verify the validity and accuracy of the new formula.

Chern, E. J.↗

A practical ultrasonic plethysmograph

An ultrasonic plethysmograph, which gives improved performance over the standard Whitney Strain Gauge, is described. This instrument monitors dimension changes in human limbs by measuring the transit times of acoustic pulses across two chords of the limb. In the case of a small uniform expansion, the percentage change in limb volume is shown to be proportional to twice the percentage change in either of the measured chords. Measurement of two chords allows correction for possible non-uniform expansion. In addition, measurement of two chords allows an estimate of the absolute cross-sectional area of the limb. The developed instrument incorporates a microprocessor, which performs necessary calculation and control functions. Use of the microprocessor allows the instrument to be self-calibrating. In addition, the device can be easily reprogrammed to incorporate improvements in operating features or computational schemes.

Wu, V. C.↗

Ultrasonic measurement of axial stress

The theory of acoustic propagation in strained media is examined, with particular emphasis on rod (bolt) geometries. The continuous wave (CW) approach is the basis of the study, and the theory is developed from a frequency domain analysis standpoint in order to obtain an applied stress/normalized frequency shift relationship. CW measurements may be influenced by such factors as propagation effects, mode conversion, frequency, material properties, and geometry. After the first loading cycle, axial stress measurements for a preloading with an initial frequency of 4.995 36 MHz dropped to 4.989 19 MHz, indicating a 6.17 kHz change. CW and pseudo-CW ultrasonic techniques are found to be reliable for axial stress measurements, and acoustic attenuation measurements correlated to residual stress fields may possibly involve transducer phase cancellation. It is thus concluded that signal drop is an artifact of the transducer directivity, rather than an actual acoustic power decrease.

Heyman, J. S.↗

Measuring Ultrasonic Shear-Wave Velocity

New technique improves accuracy of measurements of ultrasonic shearwave velocity. Technique eliminates need to measure incident sound angle. Technique contains groove in which steel sphere is placed. Sphere act as reference point for measuring path lengths and propagation times. Velocity measurements are within 1 percent of published data.

Nummelin, J.↗

Ultrasonics and Optics Would Control Shot Size

Feedback system assures production of silicon shot of uniform size. Breakup of silicon stream into drops is controlled, in part, by varying frequency of vibrations imparted to stream by ultrasonic transducer. Drop size monitored by photodetector. Control method particularly advantageous in that constant size is maintained even while other process variables are changed deliberately or inadvertently. Applicable to materials other than silicon.

Morrison, A. D.↗

Effects of specimen resonances on acoustic-ultrasonic testing

The effects of specimen resonances on acoustic ultrasonic (AU) nondestructive testing were investigated. Selected resonant frequencies and the corresponding normal mode nodal patterns of the aluminum block are measured up to 75.64 kHz. Prominent peaks in the pencil lead fracture and sphere impact spectra from the two transducer locations corresponded exactly to resonant frequencies of the block. It is established that the resonant frequencies of the block dominated the spectral content of the output signal. The spectral content of the output signals is further influenced by the transducer location relative to the resonant frequency nodal lines. Implications of the results are discussed in relation to AU parameters and measurements.

Williams, J. H., Jr.↗

The effect of stress on ultrasonic pulses in fiber reinforced composites

An acoustical-ultrasonic technique was used to demonstrate relationships existing between changes in attenuation of stress waves and tensile stress for an eight ply 0 degree graphite-epoxy fiber reinforced composite. All tests were conducted in the linear range of the material for which no mechanical or macroscopic damage was evident. Changes in attenuation were measured as a function of tensile stress in the frequency domain and in the time domain. Stress wave propagation in these specimens was dispersive, i.e., the wave speed depends on frequency. Wave speeds varied from 267 400 cm/sec to 680 000 cm/sec as the frequency of the signal was varied from 150 kHz to 1.9 MHz which strongly suggests that flexural/lamb wave modes of propagation exist. The magnitude of the attenuation changes depended strongly on tensile stress. It was further observed that the wave speeds increased slightly for all tested frequencies as the stress was increased.

Hemann, J. H.↗

Improved Ultrasonic Resolution Via Analog Technique

High spatial resolution obtained from reflected or transmitted ultrasonic pulses by analog technique that produces signal proportional to magnitude of complex plane analytic representation of signal.

Gammell, P. M.↗

Ultrasonic transducer with Gaussian radial pressure distribution

An ultrasonic transducer that produces an output that is a symmetrical function comprises a piezoelectric crystal with several concentric ring electrodes on one side of the crystal. A resistor network applies different amplitudes of an ac source to each of the several electrodes. A plot of the different amplitudes from the outermost electrode to the innermost electrode is the first half of a Gaussian function. Consequently, the output of the crystal from the side opposite the electrodes has a Gaussian profile.

Claus, R. O.↗

Characterization of composite materials by means of the ultrasonic stress wave factor

The usual approach to nondestructively evaluating a composite structure involves inspection and mechanical analysis of the inspection results. Such an approach has met with only limited success. On the other hand, the ultrasonic stress wave factor technique directly evaluates the material. Despite requiring access to only one surface of the material, the technique interrogates the material in the directions of applied load. Using the stress wave factor technique it is possible to determine the failure location in the material. The correlation of the stress wave factor with stiffness is shown. In addition, the use of the technique for determining the strength or life of composite material structures is discussed.

Duke, J. C., Jr.↗

Effects of specimen resonances on acoustic-ultrasonic testing

Frequency response is studied at two different transducer locations in the 10-280 kHz range, for the case of the response of a solid 6061-T6 aluminum alloy block to the fracture of an 0.5 mm-diameter pencil lead, as well as to the impact of 0.159 and 0.318 cm-diameter stainless steel spheres. Prominent peaks in the pencil lead fracture and sphere impact spectra from the two transducer locations are found to exactly correspond to the alloy block's resonant frequencies, indicating that these have dominated the spectral content of the output signal. The spectral content is further influenced by the transducer location, relative to the resonant frequency nodal lines. The implications of these results for acoustic-ultrasonic parameters and measurements are discussed.

Williams, J. H., Jr.↗

Holder for Ultrasonic Evaluation of Small-Diameter Tubes

Simple holder eliminates requirement for expensive turntable. Holder works by rotating cylindrical specimens about y-axis. Rotation synchronized with movement of transducer to permit testing without use of turntable. Holder attached to crossmember of scanning bridge with C-clamp. Permits testing of small-diameter tubes rapidly, accurately, and economically. Designed for use with commercially available electromechanical drum-type ultrasonic immersion testing device used for nondestructive evaluation of variety of materials.

Taylor, E. C.↗

Measurement of ultrasonic fields in transparent media using a scanning differential interferometer

An experimental system for the detection of three dimensional acoustic fields in optically transparent media using a dual beam differential interferometer is described. In this system, two coherent, parallel, focused laser beams are passed through the specimen and the interference fringe pattern which results when these beams are combined shifts linearly by an amount which is related to the optical pathlength difference between the two beams. It is shown that for small signals, the detector output is directly proportional to the amplitude of the acoustic field integrated along the optical beam path through the specimen. A water tank and motorized optical platform were constructed to allow these dual beams to be scanned through an ultrasonic field generated by a piezoelectric transducer at various distances from the transducer. Scan data for the near, Fresnel, and far zones of a uniform, circular transducer are presented and an algorithm for constructing the radial field profile from this integrated optical data, assuming cylindrical symmetry, is described.

Dockery, G. D.↗