Geomagnetic transmission disturbances and heavy-ion fluences observed in low Earth orbit during the solar energetic particle events of October 1989

The large solar energetic particle (SEP) events and simultaneous large geomagnetic disturbances observed during October 1989 posed a significant, rapidly evolving space radiation hazard. Using data from the GOES-7, NOAA-10, IMP-8 and LDEF satellites, we determined the geomagnetic transmission, heavy ion fluences, mean Fe ionic charge state, and effective radiation hazard observed in low Earth orbit (LEO) for these SEPs. We modeled the geomagneitc transmission by tracing particles through the combination to the internal International Geomagnetic Reference Field (IGRF) and the Tsyganenko (1989) magnetospheric field models, extending the modeling to large geomagnetic disturbances. We used our results to assess the radiation hazard such very large SEP events would pose in the anticipated 52 deg inclination space station orbit.

Boberg, P. R.↗

Geomagnetic transmission of solar energetic protons during the geomagnetic disturbances of October 1989

Orbit-averaged geomagnetic transmission measurements during the large solar energetic particle events of October 1989 are presented using proton data from the NOAA-10 and GOES-7 satellies. The measurements are compared to geomagnetic transmission calculations determined by tracing particle trajectories through the combination of the International Geomagnetic Reference Field (IGRF) model and the 1989 Tsyganenko magnetospheric magnetic field model. The effective 'ring current' parameter in the 1989 Tsyganenko model based on the Dst data. Results are compared to calculations employing only the IGRF and to a parameterization of geomagnetically quiet-time cutoff rigidities derived from Cosmos/intercosmos observations. The 3-hour orbit-averaged results have approximately 15% accuracy during the October 1989 events.

Boberg, P. R.↗

Further Study Of Face Gears For Helicopter Transmissions

Document describes theoretical, computational, and experimental studies of feasibility of proposed lightweight, split-torque helicopter transmissions based on face gears. Majority of work also described in prior document "Face Gears for Helicopter Transmissions" (LEW-15840).

Litvin, F. L.↗

A Self Calibrating Emissivity and/or Transmissivity Independent Multiwavelength Pyrometer

Pyrometer is a favorite method to do remote temperature measurement in research and development. One-color, two-color and the disappearing filament pyrometers are most common, multicolor and multiwavelength pyrometers are being introduced recently. All these pyrometers invariably require, in one form or another, information concerning emissivity, the medium transmissivity, their ratio at some two spectral regions, the instrument's calibration constant, etc. for their operation. This information can come from hand books, from the manufacturer or in some instances, from results of dedicated separate experiments. Often this information is sample or instrument specific. Sometimes this information, though obtained from a special experiment, is obtained using a separate sample rather than the one pursued for temperature measurement. Then, there would be the question of variability from sample to sample and variability from batch to batch in the sample used. Also, previously determined calibrations can change with time, and the only way to reduce uncertainty is to perform the calibration more frequently or even immediately before the experiment. We have developed a multiwavelength pyrometer, which eliminates the need to supply the necessary emissivity and/or transmissivity information and the instrument calibration constants ahead of time. The pyrometer calibrates itself from its first cycle data.

Ng, Daniel↗

Experimental Study of Split-Path Transmission Load Sharing

Split-path transmissions are promising, attractive alternatives to the common planetary transmissions for helicopters. The split-path design offers two parallel paths for transmitting torque from the engine to the rotor. Ideally, the transmitted torque is shared equally between the two load paths; however, because of manufacturing tolerances, the design must be sized to allow for other than equal load sharing. To study the effect of tolerances, experiments were conducted using the NASA split-path test gearbox. Two gearboxes, nominally identical except for manufacturing tolerances, were tested. The clocking angle was considered to be a design parameter and used to adjust the load sharing of an otherwise fixed design. The torque carried in each path was measured for a matrix of input torques and clocking angles. The data were used to determine the optimal value and a tolerance for the clocking angles such that the most heavily loaded split path carried no greater than 53 percent of an input shaft torque of 367 N-m. The range of clocking angles satisfying this condition was -0.0012 +/- 0.0007 rad for box 1 and -0.0023 +/- 0.0009 rad for box 2. This study indicates that split-path gearboxes can be used successfully in rotorcraft and can be manufactured with existing technology.

Krantz, Timothy L.↗

A User''s Guide to the Zwikker-Kosten Transmission Line Code (ZKTL)

This user's guide documents updates to the Zwikker-Kosten Transmission Line Code (ZKTL). This code was developed for analyzing new liner concepts developed to provide increased sound absorption. Contiguous arrays of multi-degree-of-freedom (MDOF) liner elements serve as the model for these liner configurations, and Zwikker and Kosten's theory of sound propagation in channels is used to predict the surface impedance. Transmission matrices for the various liner elements incorporate both analytical and semi-empirical methods. This allows standard matrix techniques to be employed in the code to systematically calculate the composite impedance due to the individual liner elements. The ZKTL code consists of four independent subroutines: 1. Single channel impedance calculation - linear version (SCIC) 2. Single channel impedance calculation - nonlinear version (SCICNL) 3. Multi-channel, multi-segment, multi-layer impedance calculation - linear version (MCMSML) 4. Multi-channel, multi-segment, multi-layer impedance calculation - nonlinear version (MCMSMLNL) Detailed examples, comments, and explanations for each liner impedance computation module are included. Also contained in the guide are depictions of the interactive execution, input files and output files.

Kelly, J. J.↗

Transmission and Incidence Losses for a Slotted Plate

The objective of this work is to find a model of the stagnation pressure loss resulting from flow through a slotted plate, which is effectively a cascade of flat plate airfoils, particularly at very large angles of incidence. Data from a published experiment is examined, and compared with control volume analysis, and CFD code calculations. An assumption that the loss can be separated into a transmission loss and an incidence loss seems to be justified by the data. Both the data and the CFD code results are consistent with an incidence loss model in which the flow component normal to the slot axis is lost. However, the experimental transmission loss is much larger than calculated values.

Wilson, Jack↗

Ground Isolation Circuit for Isolating a Transmission Line from Ground Interference

An isolation circuit is disclosed for isolating ground interference from a wideband transmission signal. The ground isolation circuit of the present invention is constructed using a pair of matched mixer circuits. each of which receives a carrier signal from the same oscillator circuit. The first mixer circuit also receives the baseband signal input after appropriate conditioning, and modulates the baseband signal onto the carrier signal. In the preferred embodiment, the carrier signal has a predetermined frequency which is at least two times the frequency of the baseband signal. The modulated signal (which preferably comprises an rf signal) is transmitted via an rf transmission line to the second mixer, which demodulates the rf signal to recover the baseband signal. Each port of the mixer circuits connects to an isolation transformer to insure isolation from ground interference.

Davidson, Craig A.↗

Acoustic Reflection and Transmission of 2-Dimensional Rotors and Stators, Including Mode and Frequency Scattering Effects

A reduced order modeling scheme has been developed for the unsteady acoustic and vortical coupling between blade rows of a turbomachine. The essential behavior of the system is governed by modal scattering coefficients (i.e., reflection and transmission coefficients) of the rotor, stator, inlet and nozzle, which are calculated as if they were connected to non-reflecting ducts. The objective of this report is to identify fundamental behavior of these scattering coefficients for a better understanding of the role of blade row reflection and transmission in noise generation. A 2D flat plate unsteady cascade model is used for the analysis with the expectation that the general behavior presented herein will carry over to models that include more realistic flow and geometry. It is shown that stators scatter input waves into many modes at the same frequency whereas rotors scatter on frequency, or harmonic order. Important cases are shown here the rotor reflection coefficient is greater than unity; a mode at blade passing frequency (BPF) traveling from the stator with unit sound power is reflected by the rotor with more than unit power at 2xBPF and 3xBPE Analysis is presented to explain this unexpected phenomenon. Scattering curves are presented in a format chosen for design use and for physical interpretation. To aid in interpretation of the curves, formulas are derived for special condition where waveforms are parallel to perpendicular to the rotor.

Hanson, Donald B.↗

Ion Transmission to the Focal Plane of the Chandra X-Ray Observatory

The severe degradation in spectrometric performance observed by the AXAF CCD Imaging Spectrometer (ACIS) instrument on-board the Chandra X-ray Observatory (CXO) was associated with a sharp increase in charge transfer inefficiency combined with relatively constant dark current. It was also observed that damage occurred only during passage through the earth's radiation belts, and only when ACIS remained in the focal plane during the passage. Subsequent measurements and analyses support the conjecture that the damaging radiation entered through the Observatory's High-Resolution Mirror Assembly (HRMA) aperture. A mechanism whereby low energy magnetospheric protons and/or heavier ions are scattered through the HRMA and reach the focal plane with just enough energy to stop in the CCD's charge transfer region currently provides a reasonably consistent explanation of all observed phenomena. In this paper, we will describe analyses which support this conclusion. Simulations using standard ion transmission codes were used to generate a bi-directional response function (BDRF) for the mirror surfaces and transmission through the various path elements. The BDRF was convolved with the geometry via ray-trace. Damage estimates using measured proton fluence and ground measurements of ACIS- type CCD damage vs. proton energy will be presented and compared with observed on- orbit damage.

Kolodziejczak, J. J.↗

The Low Energy Effective Area of the Chandra Low Energy Transmission Grating Spectrograph

The Chandra X-ray Observatory was successfully launched on July 23, 1999, and subsequently began an intensive calibration phase. We present the preliminary results from the in-flight calibration of the low energy response of the High Resolution Camera spectroscopic readout (HRC-S) combined with the Low Energy Transmission Grating (LETG) aboard Chandra. These instruments comprise the Low Energy Transmission Grating Spectrograph (LETGS). For this calibration study, we employ a pure hydrogen non-LTE white dwarf emission model (T = 25000 K and log g = 9.0) for comparison with the Chandra observations of Sirius B. The pre-flight calibration of the LETGS effective area only covered wavelengths shortward of 44 A (E less than 277 eV). Our Sirius B analysis shows that the HRC-S quantum efficiency (QE) model assumed for longer wavelengths leads to an overestimate of the effective area by an average factor of about 1.6. We derive a correction to the low energy HRC-S QE model to match the predicted and observed Sirius B spectra over the wavelength range of 44-185 A. We make an independent test of our results by the comparison of a Chandra LETGS observation of HZ 43 with pure hydrogen model atmosphere predictions and find good agreement.

Pease, D.↗

Finite Ground Coplanar (FGC) Waveguide: A Better Transmission Line for Microwave Circuits

A new version of coplanar waveguide (CPW) with electrically narrow ground strips 14 has been developed for microwave integrated circuits. This transmission line, referred to by Finite Ground Coplanar (FGC) waveguide, has several advantages over conventional coplanar waveguide. Since the ground strips are narrow, parasitic resonances that develop when the CPW is placed on a carrier or in a package are eliminated. In addition, the narrow ground strips permit the integration of lumped and distributed circuit elements in the ground strips as well as in the center strip to reduce the circuit size and improve its performance. Finally, the coupling between adjacent FGC transmission lines is lower than the coupling between CPW lines for the same spacing between the lines. All of these attributes of FGC are presented in this paper.

Ponchak, George E.↗

Experimental Analysis of Mast Lifting and Bending Forces on Vibration Patterns Before and After Pinion Reinstallation in an OH-58 Transmission Test Rig

As part of a cooperative research program between NASA Ames Research Center, NASA Glenn Research Center, and the U.S. Army Laboratories, a series of experiments are being performed on the 500 HP OH-58a Transmission Test Rig at NASA Glenn Research Center. The findings reported in this paper were drawn from Phase 1 of a two-phase experiment, and are focused on the vibration response of an undamaged pinion gear and planetary system operating in situ in the transmission test rig. Phase 2 of the experiment, which is reported elsewhere, introduced a seeded fault into the pinion gear and tracked its progress in real-time. Based on methods presented here, further experimental research will be conducted to examine planetary system faults.

Huff, Edward M.↗

Principal Components Analysis of Triaxial Vibration Data From Helicopter Transmissions

Research on the nature of the vibration data collected from helicopter transmissions during flight experiments has led to several crucial observations believed to be responsible for the high rates of false alarms and missed detections in aircraft vibration monitoring systems. This work focuses on one such finding, namely, the need to consider additional sources of information about system vibrations. In this light, helicopter transmission vibration data, collected using triaxial accelerometers, were explored in three different directions, analyzed for content, and then combined using Principal Components Analysis (PCA) to analyze changes in directionality. In this paper, the PCA transformation is applied to 176 test conditions/data sets collected from an OH58C helicopter to derive the overall experiment-wide covariance matrix and its principal eigenvectors. The experiment-wide eigenvectors. are then projected onto the individual test conditions to evaluate changes and similarities in their directionality based on the various experimental factors. The paper will present the foundations of the proposed approach, addressing the question of whether experiment-wide eigenvectors accurately model the vibration modes in individual test conditions. The results will further determine the value of using directionality and triaxial accelerometers for vibration monitoring and anomaly detection.

Tumer, Irem Y.↗

Torque Splitting by a Concentric Face Gear Transmission

Tests of a 167 Kilowatt (224 Horsepower) split torque face gearbox were performed by the Boeing Company in Mesa, Arizona, while working under a Defense Advanced Research Projects Agency (DARPA) Technology Reinvestment Program (TRP). This paper provides a summary of these cooperative tests, which were jointly funded by Boeing and DARPA. Design, manufacture and testing of the scaled-power TRP proof-of-concept (POC) split torque gearbox followed preliminary evaluations of the concept performed early in the program. The split torque tests were run using 200 N-m (1767 in-lbs) torque input to each side of the transmission. During tests, two input pinions were slow rolled while in mesh with the two face gears. Two idler gears were also used in the configuration to recombine torque near the output. Resistance was applied at the output face gear to create the required loading conditions in the gear teeth. A system of weights, pulleys and cables were used in the test rig to provide both the input and output loading. Strain gages applied in the tooth root fillets provided strain indication used to determine torque splitting conditions at the input pinions. The final two pinion-two idler tests indicated 52% to 48% average torque split capabilities for the two pinions. During the same tests, a 57% to 43% average distribution of the torque being recombined to the upper face gear from the lower face gear was measured between the two idlers. The POC split torque tests demonstrated that face gears can be applied effectively in split torque rotorcraft transmissions, yielding good potential for significant weight, cost and reliability improvements over existing equipment using spiral bevel gearing.

Filler, Robert R.↗

Development of Novel Methods for the Reduction of Noise and Weight in Helicopter Transmissions

Over the 70-year evolution of the helicopter, man's understanding of vibration control has greatly increased. However, in spite of the increased performance, the extent of helicopter vibration problems has not significantly diminished. Crew vibration and noise remains important factors in the design of all current helicopters. With more complex and critical demands being placed on aircrews, it is essential that vibration and noise not impair their performance. A major source of helicopter cabin noise (which has been measured at a sound pressure level of over 100 dB) is the gearbox. Reduction of this noise has been a goal of NASA and the U.S. Army. Gear mesh noise is typically in the frequency range of 1000 to 3000 Hz, a range important for speech. A requirement for U.S. Army/NASA Advanced Rotorcraft Transmission project has been a 10-dB reduction compared to current designs. A combined analytical/experimental effort has been underway, since the end of the 80's, to study effects of design parameters on noise production. The noise generated by the gear mesh can be transmitted to the surrounding media through the bearings that support the gear shaft. Therefore, the use of fluid film bearings instead of rolling element bearings could reduce the transmission noise by 10 dB. In addition, the fluid film bearings that support the gear shaft can change the dynamics of the gear assembly by providing damping to the system and by being softer than rolling element bearings. Wave bearings can attenuate, and filter, the noise generated by a machine component due to the dynamic stiffness and damping coefficients. The attenuation ratio could be as large as 35-40 dB. The noise components at higher frequencies than a synchronous frequency can be almost eliminated.

Dimofte, Florin↗

Experimental Analysis of Reduced-Sized Coplanar Waveguide Transmission Lines

An experimental investigation of the use of capacitive loading of coplanar waveguides to reduce their line length and, thus the size, of monolithic microwave integrated circuits is presented. The reduced sized coplanar waveguides are compared to unloaded transmission lines and to lumped element transmission line segments. The phase bandwidth, defined by 2 percent error in S(sub 21), and the return loss bandwidth, defined by a return loss greater than 15 dB, of coplanar waveguides reduced from 0 to 90 percent are compared, and the insertion loss as a function of the size reduction is presented.

Ponchak, George E.↗

Transmission of RF Signals Over Optical Fiber for Avionics Applications

During flight, aircraft avionics transmit and receive RF signals to/from antennas over coaxial cables. As the density and complexity of onboard avionics increases, the electromagnetic interference (EM) environment degrades proportionately, leading to decreasing signal-to-noise ratios (SNRs) and potential safety concerns. The coaxial cables are inherently lossy, limiting the RF signal bandwidth while adding considerable weight. To overcome these limitations, we have investigated a fiber optic communications link for aircraft that utilizes wavelength division multiplexing (WDM) to support the simultaneous transmission of multiple signals (including RF) over a single optical fiber. Optical fiber has many advantages over coaxial cable, particularly lower loss, greater bandwidth, and immunity to EM. In this paper, we demonstrate that WDM can be successfully used to transmit multiple RF signals over a single optical fiber with no appreciable signal degradation. We investigate the transmission of FM and AM analog modulated signals, as well as FSK digital modulated signals, over a fiber optic link (FOL) employing WDM. We present measurements of power loss, delay, SNR, carrier-to-noise ratio (CNR), total harmonic distortion (THD), and bit error rate (BER). Our experimental results indicate that WDM is a fiber optic technology suitable for avionics applications.