Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

TU-AB-BRB-03: Coverage-Based Treatment Planning to Accommodate Organ Deformable Motions and Contouring Uncertainties for Prostate Treatment

The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. The treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRB-01: Coverage Evaluation and Probabilistic Treatment Planning as a Margin Alternative

The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. The treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.

60 APPLIED LIFE SCIENCES↗

Errors in Radiotherapy: Motivation for Development of New Radiotherapy Quality Assurance Paradigms

Modern radiotherapy practice has rapidly evolved during the past decade, making use of many highly complex and/or automated processes for planning and delivery, including new techniques, like intensity-modulated radiotherapy driven by inverse planning optimization methods, or near real-time image-guided adaptive therapy based on fluoroscopic or tomographic imaging on the treatment machine. In spite of the modern technology, or potentially because of it in some instances, errors and other problems continue to have a significant impact on the field. This report reviews example errors and problems, discusses some of the quality assurance issues that these types of problems raise, and motivates the development of more modern and sophisticated approaches to assure quality for our clinical radiotherapy treatment methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of loading direction on the fracture behaviors of cortical bone at a dynamic loading rate

Here, the dynamic cracking processes in porcine cortical bone were visualized in real-time using the high-speed synchrotron X-ray phase-contrast imaging (PCI) technique in three osteon orientations: in-plane transverse, out-of-plane transverse and in-plane longitudinal. The dynamic flexural loading applied on the pre-notched bone specimens was introduced by a modified Kolsky compression bar. High-speed X-ray images of the entire loading events were documented with a high-speed camera. Three-dimensional X-ray micro-computed tomography was conducted to examine the intact microstructures and obtain the basic material properties of the bone material used for mechanical characterizations. The onset location, where crack initiated, and the subsequent direction, along which the incipient crack propagated, were measured quantitatively using the high-speed X-ray images and the latter was found dependent on the osteon direction significantly. The crack propagation velocities were dependent on crack extension over the entire crack path significantly for all the three directions while the initial velocity for in-plane longitudinal direction was lower than the other two directions. Straight-through crack paths were observed for in-plane longitudinal specimens while the cracks were deflected and twisted in the in-plane transverse direction. For out-of-plane transverse direction, the cracks follow paths with tortuosity fall in between the other two directions, showing a mixed mode of fractures of the former two extreme cases. The toughening mechanisms, visualized by the high-speed X-ray images, and the corresponding fracture toughness, evaluated in terms of fracture initiation toughness and crack growth resistance curve (R-curve), were also found significantly different among the three osteon directions, suggesting an overall transition from brittle to ductile-like fracture behaviors at the dynamic displacement rate (5.4 m/s) as the osteon orientation varies from in-plane longitudinal to out-of-plane transverse, and to in-plane transverse eventually.

42 ENGINEERING↗

FTIR imaging identifies alterations in lung tissue structure and biochemical composition in human idiopathic pulmonary fibrosis

Idiopathic Pulmonary Fibrosis (IPF) is a chronic, progressive, and fatal lung disease characterized by damage to the epithelial tissue and a reduced ability of the alveoli to repair themselves. This impaired repair process leads to abnormal accumulation of extracellular matrix (ECM), resulting in scarring and stiffening of lung tissue. Fourier transform infrared imaging (FTIRI) is a promising technique for imaging the biochemical changes related to fibrotic changes in a label-free and non-destructive manner, which can be analyzed to mark the progression of IPF. In this study, FTIRI was used to image human lung tissue biopsies with IPF and control biopsies without disease. In-depth spectral analyses were performed to observe the biochemical changes in the tissue composition using FTIRI. The parameters that were analyzed included collagen structure, total lipid content, lipid chain length, and phospholipids. Results showed a significant increase in lipid content in IPF compared to control, where long chain lipids dominated and phospholipids were reduced. Minor changes in collagen structure were also observed in IPF, likely attributed to the excess formation of extracellular matrix in the disease. These findings indicate that FTIRI has the potential to be a promising diagnostic technique to understand the molecular changes during IPF, as analysis of infrared data can reveal detailed biochemical information regarding disease progression and provide spatial insights on the molecular changes across the IPF lung tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting Rare Events in the Time-Domain

One of the biggest challenges in current and future time-domain surveys is to extract the objects of interest from the immense data stream. There are two aspects to achieving this goal: detecting variable sources and classifying them. Difference imaging provides an elegant technique for identifying new transients or changes in source brightness. Much progress has been made in recent years toward refining the process. We discuss a selection of pitfalls that can afflict an automated difference imagine pipeline and describe some solutions. After identifying true astrophysical variables, we are faced with the challenge of classifying them. For rare events, such as supernovae and microlensing, this challenge is magnified because we must balance having selection criteria that select for the largest number of objects of interest against a high contamination rate. We discuss considerations and techniques for developing classification schemes.

99 GENERAL AND MISCELLANEOUS↗

HostSub_GP: Precise Galaxy Background Subtraction in Transient Long-slit Spectroscopy with Gaussian Processes

We present a novel host galaxy subtraction technique in long-slit spectroscopy for extragalactic transients. Unlike classic methods which generally estimate the background using simple interpolation of local galaxy flux in the 2D spectrum, our approach leverages multi-band archival images of the host galaxies to model the background emission from the galaxy in the 2D spectrum. Such imaging encodes the wavelength-dependent galaxy profile along the slit, and is readily accessible through wide-field imaging surveys. We construct a smooth prior for the 2D galaxy profile with a Gaussian process (GP) based on these reference images, and use another GP to model the correlated deviations from the prior in the observed spectrum. This enables accurate inference of the galaxy flux blended with the transient. On synthetic long-slit data of a spiral galaxy extracted from a Multi Unit Spectroscopic Explorer hyper-spectral cube, the GP method remains robust as long as the host galaxy is spatially resolved and consistently outperforms classic methods. We apply the method to archival Keck spectra of two real transients, SN 2019eix and AT 2019qiz, to further demonstrate how the method uniquely recovers weak spectral features amid strong galaxy contamination, enabling refined constraints on the properties of both transients. We have released the software implementation, HostSub_GP, a scalable toolkit that leverages JAX, with an MIT license.

79 ASTRONOMY AND ASTROPHYSICS↗

Superresolution Diffuse Optical Imaging by Localization of Fluorescence

The multiple scattering of light presents major challenges in realizing useful in vivo imaging at tissue depths of more than about one millimeter, where many answers to health questions lie. Visible through near-infrared photons can be readily and safely detected through centimeters of tissue; however, limited information is available for image formation. One strategy for obtaining images is to model the photon transport and a simple incoherent model is the diffusion equation approximation to the Boltzmann transport equation. Such an approach provides a prediction of the mean intensity of heavily scattered light and hence provides a forward model for optimization-based computational imaging. While diffuse optical imaging methods have received substantial attention, they remain restricted in terms of resolution because of the loss of high-spatial-frequency information that is associated with the multiple scattering of photons. Consequently, only relatively large inhomogeneities, such as tumors or organs in small animals, can be effectively resolved. We introduce a superresolution imaging approach based on point localization in a diffusion framework that enables over two orders of magnitude improvement in the spatial resolution of diffuse optical imaging. The method is demonstrated experimentally by localizing a fluorescent inhomogeneity in a highly scattering slab and characterizing the localization uncertainty. The approach allows imaging through centimeters of tissue with a resolution of tens of microns, thereby enabling cells or cell clusters to be resolved. More generally, this high-resolution imaging approach could be applied with any physical transport or wave model and hence to a broad class of physical problems. Finally, paired with a suitable optical contrast mechanism, as can be realized with targeted fluorescent molecules or genetically modified animals, superresolution diffuse imaging should open alternative dimensions for in vivo applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: A chest phantom study

Anti-scatter grids have been widely used to reject scatter and increase the perceptibility of low-contrast object in chest radiography; however they also attenuate the primary x-rays, resulting in a substantial degradation of primary information. Compensation for this degradation requires the use of higher exposure technique hence higher dose to the patient. A more efficient approach to reject scatter is the slot-scan imaging technique which employs a narrow scanning x-ray fan beam in conjunction with a slit or slot shaped solid state detector or an area detector used with an aft-collimator. With this approach, scatter can be rejected effectively without the need to attenuate primary x-rays. This paper demonstrates an electronic aft-collimation method, referred to as the alternate line erasure and readout (ALER) technique, for implementing the slot-scan digital radiography with a modern flat-panel detector. With this technique, instead of first exposing the detector and then reading the image line by line, the image line on the leading edge of the scanning fan beam is reset to erase the scatter accumulated prior to the arrival of the fan beam x-rays, while the image line on the trailing edge of the scanning fan beam is read out to acquire the image signals following the fan-beam exposure. These reset and readout processes are alternated and repeated as the x-ray fan beam scans across the detector. An anthropomorphic chest phantom was imaged to evaluate the scatter rejection ability and the low-contrast performance for the ALER technique and compare them with those for the anti-scatter grid method in full-field chest imaging. With a projected beam width of 16 mm, the slot-scan/ALER technique resulted in an average reduction of the scatter-to-primary ratios by 81%, 84%, 82%, and 86% versus 65%, 73%, 74%, and 73% with the anti-scatter grid method in the lungs, mediastinum, retrocardium, and subdiaphragm, respectively. The average CNR for the slot-scan/ALER technique was found to improve by 135%, 133%, 176%, and 87% versus 15%, 15%, 38%, and -11% with the anti-scatter grid method in the mediastinum, retrocardium, subdiaphragm, and lungs, respectively. These results demonstrated that the slot-scan/ALER technique can be used to achieve equally effective scatter rejection but substantially higher low-contrast performance than the anti-scatter grid method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-CAMPUS-J-04: Evaluation of Metal Artifact Reduction Technique for the Radiation Therapy Planning

Purpose: To evaluate the feasibility of using a metal artifact reduction technique in depleting metal artifact and its application in improving dose calculation in External Radiation Therapy Planning. Methods: CIRS electron density phantom was scanned with and without steel drill bits placed in some plug holes. Meta artifact reduction software with Metal Deletion Technique (MDT) was used to remove metal artifacts for scanned image with metal. Hounsfield units of electron density plugs from artifact free reference image and MDT processed images were compared. To test the dose calculation improvement after the MDT processed images, clinically approved head and neck plan with manual dental artifact correction was tested. Patient images were exported and processed with MDT and plan was recalculated with new MDT image without manual correction. Dose profiles near the metal artifacts were compared. Results: The MDT used in this study effectively reduced the metal artifact caused by beam hardening and scatter. The windmill around the metal drill was greatly improved with smooth rounded view. Difference of the mean HU in each density plug between reference and MDT images were less than 10 HU in most of the plugs. Dose difference between original plan and MDT images were minimal. Conclusion: Most metal artifact reduction methods were developed for diagnostic improvement purpose. Hence Hounsfield unit accuracy was not rigorously tested before. In our test, MDT effectively eliminated metal artifacts with good HU reproduciblity. However, it can introduce new mild artifacts so the MDT images should be checked with original images.

60 APPLIED LIFE SCIENCES↗

Advanced Characterization: 3D chemistry and structure at sub-nm resolution

This work has started the process of extending nanometer-scale comprehensive microanalysis to the 3rd dimension by combining full x-ray spectral imaging with previously developed computed tomography techniques whereby we acquire a series of spectral images for a large number of projections of the same specimen in the transmission electron microscope and then analyze the composite computed tomographic spectral image data prior to application of existing tomographic reconstruction software. We have demonstrated a needle-shaped specimen geometry (shape/size and preparation method) by focused ion beam preparation and acquisition and analysis of a complete tomographic spectral image on a test material consisting of fine-grained Ni with sub-10 nm alumina particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dielectrics Under Extreme Electric Fields: In Situ Studies on Nanoscale Mechanisms (Final Technical Report)

The lack of materials that can function reliably under extreme electric fields is a critical roadblock to achieving higher energy efficiency and extended service lifetime of devices in electricity generation, transmission, and consumption. Materials typically fail at two or three orders of magnitude below their theoretical dielectric breakdown strength. Identifying the origins of premature dielectric breakdown using state-of-the-art characterization tools will, therefore, enable the design and discovery of transformational materials capable of approaching their intrinsic limits. The vast improvement in the resolution power of imaging tools, combined with the recently developed in situ electric biasing technique, has made high resolution observations of dielectric breakdown as it happens possible. The overall goal of the project is to directly image the dynamic processes of defect formation, accumulation, and interaction with preexisting defects (e.g., dislocations, domain walls, and grain boundaries in crystalline dielectric films) under electric fields up to 1,000 MV/m with a temporal resolution better than 5 microseconds. Using the newly acquired, custom-made Hysitron PI95 transmission electron microscopy (TEM) specimen holder, in situ TEM observations of breakdown at the sub nanometer resolution will be made on representative dielectric compounds with progressive complexities: the linear dielectric SiO 2 , CuO, and TiO 2 , the ferroelectric BaTiO 3 nanocrystals and nanocubes. Through direct observation of the breakdown event at high spatial and temporal resolutions, the nanoscale mechanisms for the failure of dielectrics under intense electric fields will be identified. The results of the project will be applied to the design and processing of new dielectric materials with higher efficiency, improved reliability, and a prolonged lifetime. Such new dielectrics are urgently needed for modernizing energy infrastructures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Graph Theory and Neural Networks for Microstructural Classification

Recent advances in materials data analytics have provided new avenues for determining process-structure-property (PSP) linkages in a variety of materials. Machine learning techniques including few-shot learning have increased the efficiency of classifying microscopy images for the purposes of material characterization. Modifications in segmentation also show potential in improving the accuracy of our current pyCHIP classifier. Replacing previous encoders trained on ImageNet with those trained on microscopy images like MicroNet has initially shown better performance at classifying images of irradiated samples. Additionally, different normalization approaches were tested to show no discernable effect on classification. The Louvain method for community detection is analyzed on a set of irradiated samples with different parameters to determine which proved beneficial under what circumstances. We suggest that microscopy experiments be automated in the future using a combination of these techniques to enable high-throughput analyses.

36 MATERIALS SCIENCE↗

SURFACE MORPHOLOGY OF CARBON FIBER POLYMER COMPOSITES AFTER LASER STRUCTURING

The increasing use of Carbon Fiber Polymer Composite (CFPC) as a lightweight material in automotive and aerospace industries requires the control of surface morphology. In this study, the composites surface was prepared by ablating the resin in the top fiber layer of the composite using an Nd:YAG laser. The CFPC specimens with T700S carbon fiber and Prepreg - T83 resin (epoxy) were supplied by Plasan Carbon Composites, Inc. as 4 ply thick, 0/90o plaques. The effect of laser fluence, scanning speed, and wavelength was investigated to remove resin without an excessive damage of the fibers. In addition, resin ablation due to the power variation created by a laser interference technique is presented. Optical property measurements, optical micrographs, 3D imaging, and high-resolution optical profiler images were used to study the effect of the laser processing on the surface morphology.

Sabau, Adrian S↗

Characterizing the lipid and metabolite changes associated with placental function and pregnancy complications using ion mobility spectrometry-mass spectrometry and mass spectrometry imaging

Successful pregnancy is dependent upon discrete biological events, which include embryo implantation, decidualization, and placentation. Problems associated with each of these events can cause infertility or conditions such as preeclampsia. A greater understanding of the molecular changes associated with these complex processes is necessary to aid in identifying treatments for each condition. Previous nuclear magnetic resonance spectroscopy and mass spectrometry studies have been used to identify metabolites and lipids associated with pregnancy-related complications. However, due to limitations associated with conventional implementations of both techniques, novel technology developments are needed to more fully understand the initiation and development of pregnancy related problems at the molecular level. In this perspective, we describe current analytical techniques for metabolomic and lipidomic characterization of pregnancy complications and discuss the potential for new technologies such as ion mobility spectrometry-mass spectrometry and mass spectrometry imaging to contribute to a better understanding of the molecular changes that affect the placenta and pregnancy outcomes.

Environmental Molecular Sciences Laboratory↗

Interatomic Coulombic decay in a He dimer: Ab initio potential-energy curves and decay widths

The energy gained by either of the two helium atoms in a helium dimer through simultaneous ionization and excitation can be efficiently transferred to the other helium atom, which then ionizes. The respective relaxation process called interatomic Coulombic decay (ICD) is the subject of the present paper. Specifically, we are interested in ICD of the lowest of the ionized excited states, namely, the He{sup +}(n=2)He states, for which we calculated the relevant potential-energy curves and the interatomic decay widths. The full-configuration interaction method was used to obtain the potential-energy curves. The decay widths were computed by utilizing the Fano ansatz, Green's-function methods, and the Stieltjes imaging technique. The behavior of the decay widths with the interatomic distance is examined and is elucidated, whereby special emphasis is given to the asymptotically large interatomic separations. Our calculations show that the electronic ICD processes dominate over the radiative decay mechanisms over a wide range of interatomic distances. The ICD in the helium dimer has recently been measured by Havermeier et al. [Phys. Rev. Lett. 104, 133401 (2010)]. The impact of nuclear dynamics on the ICD process is extremely important and is discussed by Sisourat et al. [Nat. Phys. 6, 508 (2010)] based on the ab initio data computed in the present paper.

74 ATOMIC AND MOLECULAR PHYSICS↗

Bayesian Active Learning for Scanning Probe Microscopy: From Gaussian Processes to Hypothesis Learning

Recent progress in machine learning methods and the emerging availability of programmable interfaces for scanning probe microscopes (SPMs) have propelled automated and autonomous microscopies to the forefront of attention of the scientific community. However, enabling automated microscopy requires the development of task-specific machine learning methods, understanding the interplay between physics discovery and machine learning, and fully defined discovery workflows. This, in turn, requires balancing the physical intuition and prior knowledge of the domain scientist with rewards that define experimental goals and machine learning algorithms that can translate these to specific experimental protocols. Here, we discuss the basic principles of Bayesian active learning and illustrate its applications for SPM. We progress from the Gaussian process as a simple data-driven method and Bayesian inference for physical models as an extension of physics-based functional fits to more complex deep kernel learning methods, structured Gaussian processes, and hypothesis learning. These frameworks allow for the use of prior data, the discovery of specific functionalities as encoded in spectral data, and exploration of physical laws manifesting during the experiment. Here, the discussed framework can be universally applied to all techniques combining imaging and spectroscopy, SPM methods, nanoindentation, electron microscopy and spectroscopy, and chemical imaging methods and can be particularly impactful for destructive or irreversible measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiopaque Resists for Two-Photon Lithography To Enable Submicron 3D Imaging of Polymer Parts via X-ray Computed Tomography

Two-photon lithography (TPL) is a high-resolution additive manufacturing (AM) technique capable of producing arbitrarily complex three-dimensional (3D) microstructures with features 2–3 orders of magnitude finer than human hair. This process finds numerous applications as a direct route toward the fabrication of novel optical and mechanical metamaterials, miniaturized optics, microfluidics, biological scaffolds, and various other intricate 3D parts. As TPL matures, metrology and inspection become a crucial step in the manufacturing process to ensure that the geometric form of the end product meets design specifications. X-ray-based computed tomography (CT) is a nondestructive technique that can provide this inspection capability for the evaluation of complex internal 3D structure. However, polymeric photoresists commonly used for TPL, as well as other forms of stereolithography, poorly attenuate X-rays due to the low atomic number (Z) of their constituent elements and therefore appear relatively transparent during imaging. We present the development of optically clear yet radiopaque photoresists for enhanced contrast under X-ray CT. We have synthesized iodinated acrylate monomers to formulate high-Z photoresist materials that are capable of forming 3D microstructures with sub-150 nm features. In addition, we have developed a formulation protocol to match the refractive index of the photoresists to the immersion medium of the objective lens so as to enable dip-in laser lithography, a direct laser writing technique for producing millimeter-tall structures. Our radiopaque photopolymer then resists increase X-ray attenuation by a factor of more than 10 times without sacrificing the sub-150 nm feature resolution or the millimeter-scale part height. Thus, our resists can successfully replace existing photopolymers to generate AM parts that are suitable for inspection via X-ray CT. By providing the “feedstock” for radiopaque AM parts, our resist formulation is expected to play a critical role in enabling fabrication of functional polymer parts to tight design tolerances.

36 MATERIALS SCIENCE↗