Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Graphical interface between the CIRSSE testbed and CimStation software with MCS/CTOS

This research is concerned with developing a graphical simulation of the testbed at the Center for Intelligent Robotic Systems for Space Exploration (CIRSSE) and the interface which allows for communication between the two. Such an interface is useful in telerobotic operations, and as a functional interaction tool for testbed users. Creating a simulated model of a real world system, generates inevitable calibration discrepancies between them. This thesis gives a brief overview of the work done to date in the area of workcell representation and communication, describes the development of the CIRSSE interface, and gives a direction for future work in the area of system calibration. The CimStation software used for development of this interface, is a highly versatile robotic workcell simulation package which has been programmed for this application with a scale graphical model of the testbed, and supporting interface menu code. A need for this tool has been identified for the reasons of path previewing, as a window on teleoperation and for calibration of simulated vs. real world models. The interface allows information (i.e., joint angles) generated by CimStation to be sent as motion goal positions to the testbed robots. An option of the interface has been established such that joint angle information generated by supporting testbed algorithms (i.e., TG, collision avoidance) can be piped through CimStation as a visual preview of the path.

Hron, Anna B.↗

Novel gas exposure system for the controlled exposure of plants to gaseous hydrogen fluoride

Abstract Plants can serve as sensitive bioindicators of the presence of contaminant vapors in the atmosphere. This work describes a novel laboratory-based gas exposure system capable of calibrating plants as bioindicators for the detection and delineation of the atmospheric contaminant hydrogen fluoride (HF) as a preparatory step for monitoring release emissions. To evaluate changes in plant phenotype and stress-induced physiological effects attributed to HF alone, the gas exposure chamber must have additional controls to simulate otherwise optimal plant growth conditions including variables such as light intensity, photoperiod, temperature, and irrigation. The exposure system was designed to maintain constant growth conditions during a series of independent experiments that varied between optimal (control) and stressful (HF exposure) conditions. The system was also designed to ensure the safe handling and application of HF. An initial system calibration introduced HF gas into the exposure chamber and monitored HF concentrations by cavity ring-down spectroscopy for a 48-h period. Stable concentrations inside the exposure chamber were observed after approximately 15 h, and losses of HF to the system ranged from 88 to 91%. A model plant species ( Festuca arundinacea ) was then exposed to HF for 48 h. Visual phenotype stress-induced responses aligned with symptoms reported in the literature for fluoride exposure (tip dieback and discoloration along the dieback transition margin). Fluoride concentrations in exposed tissues compared to control tissues confirmed enhanced fluoride uptake due to HF exposure. The system described herein can be applied to other reactive atmospheric pollutants of interest in support of bioindicator research.

54 ENVIRONMENTAL SCIENCES↗

CALIBRATION OF THE MEARTH PHOTOMETRIC SYSTEM: OPTICAL MAGNITUDES AND PHOTOMETRIC METALLICITY ESTIMATES FOR 1802 NEARBY M-DWARFS

The MEarth Project is a photometric survey systematically searching the smallest stars near the Sun for transiting rocky planets. Since 2008, MEarth has taken approximately two million images of 1844 stars suspected to be mid-to-late M dwarfs. We have augmented this survey by taking nightly exposures of photometric standard stars and have utilized this data to photometrically calibrate the MEarth system, identify photometric nights, and obtain an optical magnitude with 1.5% precision for each M dwarf system. Each optical magnitude is an average over many years of data, and therefore should be largely immune to stellar variability and flaring. We combine this with trigonometric distance measurements, spectroscopic metallicity measurements, and 2MASS infrared magnitude measurements in order to derive a color–magnitude–metallicity relation across the mid-to-late M dwarf spectral sequence that can reproduce spectroscopic metallicity determinations to a precision of 0.1 dex. We release optical magnitudes and metallicity estimates for 1567 M dwarfs, many of which did not have an accurate determination of either prior to this work. For an additional 277 stars without a trigonometric parallax, we provide an estimate of the distance, assuming solar neighborhood metallicity. We find that the median metallicity for a volume-limited sample of stars within 20 pc of the Sun is [Fe/H] = −0.03 ± 0.008, and that 29/565 of these stars have a metallicity of [Fe/H] = −0.5 or lower, similar to the low-metallicity distribution of nearby G dwarfs. When combined with the results of ongoing and future planet surveys targeting these objects, the metallicity estimates presented here will be important for assessing the significance of any putative planet–metallicity correlation.

79 ASTRONOMY AND ASTROPHYSICS↗

New Method for Calibration for Hyperspectral Pushbroom Imaging Systems

A new, easy-to-implement approach for achieving highly accurate spectral and radiometric calibration of array-based, hyperspectral pushbroom imagers is presented in this paper. The equivalence of the plane of the exit port of an integrating sphere to a Lambertian surface is utilized to provide a field-filling radiance source for the imager. Several different continuous wave lasers of various wavelengths and a quartz-tungsten-halogen lamp internally illuminate the sphere. The imager is positioned to "stare" into the port, and the resultant data cube is analyzed to determine wavelength calibrations, spectral widths of channels, radiometric characteristics, and signal-to-noise ratio, as well as an estimate of signal-to-noise performance in the field. The "smile" (geometric distortion of spectra) of the system can be quickly ascertained using this method. As the price and availability of solid state laser sources improve, this technique could gain wide acceptance.

Ryan, Robert↗

OpenCSP Camera Calibration: Document Version 1.0

This report provides instructions on how to perform an OpenCSP camera lens calibration, which characterizes the inherent distortion in camera-lens systems. This calibration is necessary for many OpenCSP photogrammetry calculations and should be performed individually for every new camera or after adjusting lens settings.

42 ENGINEERING↗

The ion mass spectrometer on Giotto

The design of the Giotto ion mass spectrometer (IMS) system, its calibration, and the initial flight performance are discussed. The IMS system consists of two sensors: one optimized for the outer coma, the other for the inner coma, with each sensor obtaining complementary information in the region for which it was not optimized. Both sensors feature mass-imaging characteristics, permitting simultaneous measurements of several ion species by means of multi-detector arrays, with resultant mass per charge resolution of not less than 20. In addition to mass per charge, the energy per charge and the elevation and azimuth of the incident ions were measured during the Giotto flight.

Balsiger, H.↗

Importance of Calibration/Validation Traceability for Multi-Sensor Imaging Spectrometry Applications

Knowledge of calibration traceability is essential for ensuring the quality of data products relying on multiple sensors and especially true for imaging spectrometers. The current work discusses the expected impact that imaging spectrometers have in ensuring radiometric traceability for both multispectral and hyperspectral products. The Climate Absolute Radiance and Refractivity Observatory Pathfinder mission is used to show the role that high-accuracy imaging spectrometers can play in understanding test sites used for vicarious calibration of sensors. The associated Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer calibration demonstration system is used to illustrate recent advances in laboratory radiometric calibration approaches that will allow both the use of imaging spectrometers as calibration standards as well as to ensure the consistency of the multiple imaging spectrometers expected to be on orbit in the next decade.

imagin↗

NRC technical basis for evaluation of its position on protection against common cause failure in digital systems used in nuclear power plants - 378

Digital technology has advantages over analog systems, including automated monitoring and alerts for standby safety functions, and predictive algorithms to maintain critical safety systems. Additionally, digital technology generally has higher reliability and can be designed to reduce single point vulnerabilities. For these reasons many nuclear plants have applied digital technology to safety and non-safety related applications, including reactor protection system, feedwater and turbine controls, etc. with a corresponding significant improvement in trip reduction. Nonetheless, digital instrumentation and control (I and C) systems also present potential new vulnerabilities that need to be assessed, including potential failures due to increased complexity of digital systems, the introduction of unique failure modes due to software (including software common cause failure (CCF)), and limited operating history of digital systems in nuclear safety related applications compared to analog systems. The fact that software is intangible means that common methods, such as analysis or testing, used for detecting CCF may not be effective when applied to software. Consequently, digital technology is perceived to pose a potential risk from the introduction of undetected systematic faults that could result in CCF. Despite the I and C system upgrades and modifications performed to date, the U.S. Nuclear Regulatory Commission (NRC) and industry stakeholders have identified the need to modernize the regulatory infrastructure to efficiently address risks associated with the use of digital technology for nuclear safety applications and address regulatory uncertainties. The NRC's current position on CCF is guided by the staff requirements memorandum (SRM) on SECY 93-087. The SRM provides specific acceptance criteria for the evaluation of CCF, which the staff implemented in the Branch Technical Position (BTP) 7-19. However, industry stakeholders have proposed using methods to characterize the likelihood of software CCF and eliminate it from further consideration in a defense-in-depth and diversity analysis. The NRC's current position does not consider these alternatives, and thus corresponding acceptance criteria is not currently available. The work discussed in this paper assesses the underlying technical basis associated with CCF, provides technical support for updating the NRC position and considers proposed methods for addressing potential CCF in digital systems while enhancing efficiency, clarity, and confidence. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A system for testing airdata probes at high angles of attack using a ground vehicle

A system to calibrate airdata probes at angles of attack between 0 and 90 deg was developed and tested at the NASA Ames Dryden Flight Research Facility. This system used a test fixture mounted to the roof of a ground vehicle and included an onboard instrumentation and data acquisition system for measuring pressures and flow angles. The data could be easily transferred to the facility mainframe computer for further analysis. The system was designed to provide convenient and inexpensive airdata probe calibrations for projects which require airdata at high angles of attack, such as the F-18 High Alpha Research Program. This type of probe was tested to 90 deg angle of attack in a wind tunnel and using the ground vehicle system. The results of both tests are in close agreement. An airdata probe with a swiveling pilot-static tube was also calibrated with the ground vehicle system. This paper presents the results of these tests and gives a detailed description of the test system.

Geenen, Robert J.↗

ELECTRONICS UPGRADE TO THE SAVANNAH RIVER NATIONAL LABORATORY COULOMETER FOR PLUTONIUM AND NEPTUNIUM ASSAY

The Savannah River Site (SRS) has the analytical measurement capability to perform high-precision plutonium concentration measurements by controlled-potential coulometry. State-of-the-art controlled-potential coulometers were designed and fabricated by the Savannah River National Laboratory and installed in the Analytical Laboratories process control laboratory. The Analytical Laboratories uses coulometry for routine accountability measurements of and for verification of standard preparations used to calibrate other plutonium measurement systems routinely applied to process control, nuclear safety, and other accountability applications. The SRNL Coulometer has a demonstrated measurement reliability of {approx}0.05% for 10 mg samples. The system has also been applied to the characterization of neptunium standard solutions with a comparable reliability. The SRNL coulometer features: a patented current integration system; continuous electrical calibration versus Faraday's Constants and Ohm's Law; the control-potential adjustment technique for enhanced application of the Nernst Equation; a wide operating room temperature range; and a fully automated instrument control and data acquisition capability. Systems have been supplied to the International Atomic Energy Agency (IAEA), Russia, Japanese Atomic Energy Agency (JAEA) and the New Brunswick Laboratory (NBL). The most recent vintage of electronics was based on early 1990's integrated circuits. Many of the components are no longer available. At the request of the IAEA and the Department of State, SRNL has completed an electronics upgrade of their controlled-potential coulometer design. Three systems have built with the new design, one for the IAEA which was installed at SAL in May 2011, one system for Los Alamos National Laboratory, (LANL) and one for the SRS Analytical Laboratory. The LANL and SRS systems are undergoing startup testing with installation scheduled for this summer.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reflectance calibrations of AXAF mirror samples at absorption edges using synchrotron radiation

We are developing a system to calibrate reflectances of witness coupons to the AXAF flight mirrors at the National Synchrotron Light Source over the 0.05-12 keV energy range. These witness coupons will be coated in the same process as the AXAF mirror elements. One of the key issues is the accurate determination of mirror efficiencies across the absorption edges of the mirror coating elements. We present a series of reflectance measurements with 2 eV resolution of a nickel-coated flat mirror in the region of the Ni L-II (870 eV) and L-III (853 eV) absorption edges. Scans of reflectance versus grazing angle at fixed energies in this region show distinct interference fringes at grazing angles larger than the critical angle which are extinguished as the photon energy is increased beyond the low point of the L-III edge, indicating total absorption of the evanescent wave within the Ni film. At 51 arc minutes grazing angle, measured reflectance decreases smoothly by 35 percent and then recovers in an 8 eV band at the L-III edge. We have also measured reflectances in the M absorption edge region for gold, platinum, and iridium coated mirrors. We derive optical parameters n and k specific to the film for comparison to the existing data tables.

Graessle, D. E.↗

Thunderstorm and Fair-weather Quasi-Static Electric Fields Over Land and Ocean

Natural lightning and the associated clouds are known to behave differently over land and ocean, but many questions remain. We expand the related observational datasets by obtaining simultaneous quasi-static electric field observations over coastal land, near-shore water, and deep ocean regions during both fair-weather and thunderstorm periods. Oceanic observations were obtained using two 3-m NOAA buoys that were instrumented with Campbell Scientific electric field mills to measure the quasi-static electric fields. These data were compared to selected electric field records from the existing on-shore electric field mill suite of 31 sensors at Kennedy Space Center (KSC). Lightning occurrence times, locations and peak current estimates for both onshore and ocean were provided by the U.S. National Lightning Detection Network. The buoy instruments were first evaluated on-shore at the Florida coast, and the first system was calibrated for field enhancements and to confirm proper behavior of the system in elevated-field environments. The buoys were then moored 20 mi and 120 mi off the coast of KSC in February (20 mi) and August (120 mi) 2014. Diurnal fair-weather fields at both ocean sites matched will with each other and with those found during the Carnegie cruise, but mean values were 33% smaller, due at least in-part to constraints on the calibration procedure. Diurnal fair-weather fields variations at coastal and inland sites were a poorer match than offshore, likely because the offshore environment is “cleaner” with limited variations in local space charge, lower surface aerosol densities, little surface heating to disturb the surface charge layer during fair weather, and fewer local radioactive sources to modulate the near-surface electrical conductivity. Storm-related static fields were 4-5× larger at both oceanic sites than over land, likely due to decreased screening by near-surface space charge produced by corona current. The time-evolution of the electric field and field changes during storm approach are sufficiently different over land and ocean to warrant further study. This work shows the quality, accuracy, and reliability of these data, and has demonstrated the practicality of off-shore electric field measurements for safety- and launch-related decision making at KSC.

Lightning↗

Calibration of the Accuscan II In Vivo System for Whole Body Counting

This report describes the April 2011 calibration of the Accuscan II HpGe In Vivo system for whole body counting. The source used for the calibration was a NIST traceable BOMAB manufactured by DOE as INL2006 BOMAB containing Eu-154, Eu-155, Eu-152, Sb-125 and Y-88 with energies from 27 keV to 1836 keV with a reference date of 11/29/2006. The actual usable energy range was 86.5 keV to 1597 keV on 4/21/2011. The BOMAB was constructed inside the Accuscan II counting 'tub' in the order of legs, thighs, abdomen, thorax/arms, neck, and head. Each piece was taped to the backwall of the counter. The arms were taped to the thorax. The phantom was constructed between the v-ridges on the backwall of the Accuscan II counter. The energy and efficiency calibrations were performed using the INL2006 BOMAB. The calibrations were performed with the detectors in the scanning mode. This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for whole body counting and verified in accordance with ANSI/HPS N13.30-1996 criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-C-17A-06: A Hardware Implementation and Evaluation of Robotic SPECT: Toward Molecular Imaging Onboard Radiation Therapy Machines

Purpose: To construct a robotic SPECT system and demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch. The system has potential for on-board functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was developed utilizing a Digirad 2020tc detector and a KUKA KR150-L110 robot. An imaging study was performed with the PET CT Phantom, which includes 5 spheres: 10, 13, 17, 22 and 28 mm in diameter. Sphere-tobackground concentration ratio was 6:1 of Tc99m. The phantom was placed on a flat-top couch. SPECT projections were acquired with a parallel-hole collimator and a single pinhole collimator. The robotic system navigated the detector tracing the flat-top table to maintain the closest possible proximity to the phantom. For image reconstruction, detector trajectories were described by six parameters: radius-of-rotation, x and z detector shifts, and detector rotation θ, tilt ϕ and twist γ. These six parameters were obtained from the robotic system by calibrating the robot base and tool coordinates. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector-to-COR (center-ofrotation) distance. In acquisitions with background at 1/6th sphere activity concentration, photopeak contamination was heavy, yet the 17, 22, and 28 mm diameter spheres were readily observed with the parallel hole imaging, and the single, targeted sphere (28 mm diameter) was readily observed in the pinhole region-of-interest (ROI) imaging. Conclusion: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frame could be an effective means to estimate detector pose for use in SPECT image reconstruction. PHS/NIH/NCI grant R21-CA156390-01A1.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pattern-recognition techniques applied to performance monitoring of the DSS 13 34-meter antenna control assembly

The results of applying pattern recognition techniques to diagnose fault conditions in the pointing system of one of the Deep Space network's large antennas, the DSS 13 34-meter structure, are discussed. A previous article described an experiment whereby a neural network technique was used to identify fault classes by using data obtained from a simulation model of the Deep Space Network (DSN) 70-meter antenna system. Described here is the extension of these classification techniques to the analysis of real data from the field. The general architecture and philosophy of an autonomous monitoring paradigm is described and classification results are discussed and analyzed in this context. Key features of this approach include a probabilistic time-varying context model, the effective integration of signal processing and system identification techniques with pattern recognition algorithms, and the ability to calibrate the system given limited amounts of training data. Reported here are recognition accuracies in the 97 to 98 percent range for the particular fault classes included in the experiments.

Mellstrom, J. A.↗

RF quantity gauging system

The modifications, calibration, and tests of the RF liquid mass gaging system, Benedix Type X1625027, are given. Also given are test methods, test results, and optimum performance of the system.

Source record↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗