Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array

Purpose: The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array, which generates all the projection images needed for tomosynthesis reconstruction by electronically activating individual x-ray sources without any mechanical motion. The stationary digital breast tomosynthesis (s-DBT) design aims to (i) increase the system spatial resolution by eliminating image blurring due to x-ray tube motion and (ii) reduce the scanning time. Low spatial resolution and long scanning time are the two main technical limitations of current DBT technology. Methods: A CNT x-ray source array was designed and evaluated against a set of targeted system performance parameters. Simulations were performed to determine the maximum anode heat load at the desired focal spot size and to design the electron focusing optics. Field emission current from CNT cathode was measured for an extended period of time to determine the stable life time of CNT cathode for an expected clinical operation scenario. The source array was manufactured, tested, and integrated with a Selenia scanner. An electronic control unit was developed to interface the source array with the detection system and to scan and regulate x-ray beams. The performance of the s-DBT system was evaluated using physical phantoms. Results: The spatially distributed CNT x-ray source array comprised 31 individually addressable x-ray sources covering a 30 angular span with 1 pitch and an isotropic focal spot size of 0.6 mm at full width at half-maximum. Stable operation at 28 kV(peak) anode voltage and 38 mA tube current was demonstrated with extended lifetime and good source-to-source consistency. For the standard imaging protocol of 15 views over 14, 100 mAs dose, and 2 x 2 detector binning, the projection resolution along the scanning direction increased from 4.0 cycles/mm [at 10% modulation-transfer-function (MTF)] in DBT to 5.1 cycles/mm in s-DBT at magnification factor of 1.08. The improvement is more pronounced for faster scanning speeds, wider angular coverage, and smaller detector pixel sizes. The scanning speed depends on the detector, the number of views, and the imaging dose. With 240 ms detector readout time, the s-DBT system scanning time is 6.3 s for a 15-view, 100 mAs scan regardless of the angular coverage. The scanning speed can be reduced to less than 4 s when detectors become faster. Initial phantom studies showed good quality reconstructed images. Conclusions: A prototype s-DBT scanner has been developed and evaluated by retrofitting the Selenia rotating gantry DBT scanner with a spatially distributed CNT x-ray source array. Preliminary results show that it improves system spatial resolution substantially by eliminating image blur due to x-ray focal spot motion. The scanner speed of s-DBT system is independent of angular coverage and can be increased with faster detector without image degration. The accelerated lifetime measurement demonstrated the long term stability of CNT x-ray source array with typical clinical operation lifetime over 3 years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-270: Quality Control of Source Strength and Indexer Length in HDR Brachytherapy Using Sun Nuclear Mapcheck2

Purpose: The goal of this work was to evaluate Sun Nuclear MapCheck2 capability for quantitative determination of both HDR source strength and position. Predictive power of Mapcheck2 dose matrix, originated by a microSelectron-v2 source from 22mm distance, was investigated. Methods: A Mick MultiDoc phantom with the 1400mm indexer length mark aligned over MapCheck2 central detector plus two additional 5cm plastic slabs were used as a composite phantom. Dose readings were transformed by applying published source anisotropy corrections and experimentally established radial dose and relative sensitivity factors. Angular dependence was not considered. Only readings from diodes located 2cm around the central detector were evaluated. The reproducibility of a fit between transformed dose readings and the ratio of virtual source strength and the square of source-detector distance was investigated. Four parameters were considered in the model: virtual source strength, lateral, longitudinal and vertical source positions. Final source strength calibration factor was calculated from the ratio of reference measurements and results from the fit. Results: Original lateral and longitudinal source position estimations had systematic errors of 0.39mm and 0.75mm. After subtracting these errors, both source positions were predicted with a standard deviation of 0.15mm. Results for vertical positions were reproducible with a standard deviation of 0.05mm. The difference between calculated and reference source strengths from 34 independent measurement setups had a standard deviation of 0.3%. The coefficient of determination for the linear regression between known indexer lengths and results from the fit in the range 1400mm ± 5mm was 0.985. Conclusions: ource strength can be estimated with MapCheck2 at appropriate accuracy levels for quality control. Verification of indexer length with present implementation is more accurate than visual alternatives. Results can be improved by designing a coupling catheter phantom and refining relative diode calibration. Diode angular dependence in MapCheck2 does not play significant role.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRA-08: An Investigation of Well-Chamber Responses for An Electronic Brachytherapy Source

Purpose: The aim of this study was to investigate the variation of well-type ionization chamber response between a Xoft Axxent™ electronic brachytherapy (EBT) source and a GE Oncoseed™ 6711 I-125 seed. Methods: A new EBT air-kerma standard has recently been introduced by the National Institute of Standards and Technology (NIST). Historically, the Axxent source strength has been based on a well chamber calibration from an I-125 brachytherapy source due to the lack of a primary standard. Xoft utilizes a calibration procedure that employs a GE 6711 seed calibration as a surrogate standard to represent the air-kerma strength of an Axxent source. This method is based on the premise that the energies of the two sources are similar and thus, a conversion factor would be a suitable interim solution until a NIST standard was established. For this investigation, a number of well chambers of the same model type and three different EBT sources were used to determine NIST-traceable calibration coefficients for both the GE 6711 seed and the Axxent source. The ratio of the two coefficients was analyzed for consistency and also to identify any possible correlations with chamber vintage or the sources themselves. Results: For all well chambers studied, the relative standard deviation of the ratio of calibration coefficients between the two standards is less than 1%. No specific trends were found with the well chamber vintage or between the three different EBT sources used. Conclusion: The variation of well chamber calibration coefficients between a Xoft Axxent™ EBT source versus a GE 6711 Oncoseed™ are consistent across well chamber vintage and between sources. The results of this investigation confirm the underlying assumptions and stability of the surrogate standard currently in use by Xoft, and establishes a migration path for future implementation of the new NIST air kerma standard. This research is supported in part by Xoft, a subsidiary of iCAD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Magnetic field disorder and faraday effects on the polarization of extragalactic radio sources

We present a polarization catalog of 533 extragalactic radio sources that have a 2.3 GHz total intensity above 420 mJy from the S-band Polarization All Sky Survey, S-PASS, with corresponding 1.4 GHz polarization information from the NRAO VLA Sky Survey, NVSS. We studied the selection effects and found that fractional polarization, π, of radio objects at both wavelengths depends on the spectral index, the source magnetic field disorder, the source size, and depolarization. The relationship between depolarization, spectrum, and size shows that depolarization occurs primarily in the source vicinity. The median π{sub 2.3} of resolved objects in NVSS is approximately two times larger than that of unresolved sources. Sources with little depolarization are ∼2 times more polarized than both highly depolarized and re-polarized sources. This indicates that intrinsic magnetic field disorder is the dominant mechanism responsible for the observed low fractional polarization of radio sources at high frequencies. We predict that number counts from polarization surveys will be similar at 1.4 GHz and at 2.3 GHz, for fixed sensitivity, although ∼10% of all sources may currently be missing because of strong depolarization. Objects with π{sub 1.4}≈π{sub 2.3}⩾4% typically have simple Faraday structures, so they are most useful for background samples. Almost half of flat-spectrum (α⩾−0.5) and ∼25% of steep-spectrum objects are re-polarized. Steep-spectrum, depolarized sources show a weak negative correlation of depolarization with redshift in the range 0 < z < 2.3. Previous non-detections of redshift evolution are likely due the inclusion of re-polarized sources as well.

79 ASTRONOMY AND ASTROPHYSICS↗

Source apportionment of airborne particulate matter for the speciation trends network site in Cleveland, OH

Aerosol composition data from the Speciation Trends Network (STN) site (East 14th Street) in Cleveland, OH, were analyzed by advanced receptor model methods for source apportionment as well as by the standard positive matrix factorization (PMF) using PMF2. These different models are used in combination to test model limitations. These data were 24-hr average mass concentrations and compositions obtained for samples taken every third day from 2001 to 2003. The Multilinear Engine (ME) was used to solve an expanded model to estimate the source profiles and source contributions and also to investigate the wind speed, wind direction, time-of-day, weekend/weekday, and seasonal effects. PMF2 was applied to the same dataset. Potential source contribution function (PSCF) and conditional probability function (CPF) analyses were used to locate the regional and local sources using the resolved source contributions and appropriate meteorological data. Very little difference was observed between the results of the expanded model and the PMF2 values for the profiles and source contribution time series. The identified sources were as ferrous smelter, secondary sulfate, secondary nitrate, soil/combustion mixture, steel mill, traffic, wood smoke, and coal burning. The CPF analysis was useful in helping to identify local sources, whereas the PSCF results were only useful for regional source areas. Both of these analyses were more useful than the wind directional factor derived from the expanded factor analysis. However, the expanded analysis provided direct information on seasonality and day-of-week behavior of the sources. 28 refs., 8 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

The fast neutron fluence and the activation detector activity calculations using the effective source method and the adjoint function

This paper describes the application of effective source in forward calculations and the adjoint method to the solution of fast neutron fluence and activation detector activities in the reactor pressure vessel (RPV) and RPV cavity of a VVER-440 reactor. Its objective is the demonstration of both methods on a practical task. The effective source method applies the Boltzmann transport operator to time integrated source data in order to obtain neutron fluence and detector activities. By weighting the source data by time dependent decay of the detector activity, the result of the calculation is the detector activity. Alternatively, if the weighting is uniform with respect to time, the result is the fluence. The approach works because of the inherent linearity of radiation transport in non-multiplying time-invariant media. Integrated in this way, the source data are referred to as the effective source. The effective source in the forward calculations method thereby enables the analyst to replace numerous intensive transport calculations with a single transport calculation in which the time dependence and magnitude of the source are correctly represented. In this work, the effective source method has been expanded slightly in the following way: neutron source data were performed with few group method calculation using the active core calculation code MOBY-DICK. The follow-up neutron transport calculation was performed using the neutron transport code TORT to perform multigroup calculations. For comparison, an alternative method of calculation has been used based upon adjoint functions of the Boltzmann transport equation. Calculation of the three-dimensional (3-D) adjoint function for each required computational outcome has been obtained using the deterministic code TORT and the cross section library BGL440. Adjoint functions appropriate to the required fast neutron flux density and neutron reaction rates have been calculated for several significant points within the RPV and RPV cavity of the VVER-440 reacto rand located axially at the position of maximum power and at the position of the weld. Both of these methods (the effective source and the adjoint function) are briefly described in the present paper. The paper also describes their application to the solution of fast neutron fluence and detectors activities for the VVER-440 reactor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Commercial sealed sources and timely disposal: Challenges and incentives - 15456

It is widely accepted as a radioactive material management best-practice that storage of disused sealed sources should be a temporary measure. Effective end-of-life management, including timely disposition of disused and unwanted sealed sources, is an important way to address national security, public health, and safety concerns presented by long-term storage of disused sealed sources. However, significantly increased disposal access since 2012 has not led commercial sealed source generators in the U.S. to dispose of their disused and unwanted sources as quickly as many had expected. As a result, policy-makers and non-government stakeholders are considering ways to incentivize sealed source generators to make more timely decisions regarding the disposition of their disused and unwanted sources. To help ensure that ongoing efforts to develop sealed source management and disposal incentives are efficient and effective, NNSA/GMS is engaging both public and private sector partners to better understand generator considerations, motivations, and challenges with regard to sealed source management and disposal decisions. The results of these engagements to date indicate potentially effective ways to encourage sealed source waste generators to disposition their sources in a timely fashion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of the Mobile Systems for Conditioning of Disused Sealed Radioactive Sources in Serbia - 20105

Sealed radioactive sources (SRS) are being used worldwide in the field of medicine, agriculture, industry and research. They can be found in mobile as well as stationary devices. SRS contains radioactive material that is (a) permanently sealed in a capsule or (b) closely bounded and in a solid form. The capsule or material of an SRS should be strong enough to maintain leak tightness under the conditions of use and purpose for which the source was designed, also in case of accidents. In this case only emitted radiation is utilized. Firstly, the hazard from external radiation has to be considered, but the possibility of contamination due to fracture of the capsule should not be disregarded. The radioactive sources are composed of the radiating isotope contained in the filling medium, the single or double isotope holder that partially or totally surrounds the filling medium, the outer cover that contains the parts mentioned above and the capsule closed airtightly by welding or using some other method. The capsule must be tested for leakage periodically. If the SRS is no longer needed (e.g. replaced by a different technique) or it becomes useless for the intended application (e.g. the activity becomes too weak, the equipment containing the source works poorly or becomes obsolete, the source is damaged or leaking) it is considered disused. Disused sealed radioactive sources (DSRS) are typically conditioned and disposed if a facility is available. If the disposal option is not available, conditioned DSRS should be stored under proper conditions. In some cases, the radionuclide(s) in DSRS can be recovered/recycled or the DSRS can be repurposed for other applications. Conditioning of DSRS ensures containment of the radioactive material, provides confinement for leaking sources, provides sufficient radiation shielding, reduces storage/disposal volume by allowing consolidation of multiple sources into a single storage/disposal container, facilitates transport operations and contributes to safety and security as well. Typically, conditioning technologies are deployed either as permanently installed stationary systems in centralized or mobile on-site waste processing facilities, or in a mobile configuration. Centralized stationary facilities provide a single processing location for multiple users that requires transport of the waste to the facility. On the other hand, mobile systems may be provided for the selection and application of the optimum technology for a specific waste stream (such as DSRS) by bringing the process to the point where the waste is generated. In addition, mobile systems could offer additional flexibility by sharing equipment among multiple waste generating sites for processing campaigns that vary in duration, from very short periods to several years. The term 'mobile processing system' refers to any radioactive waste processing system or component which is designed to be transportable and which is not considered permanently installed. Two mobile system for conditioning of disused sealed radioactive sources are developed in the Public Company Nuclear Facilities of Serbia. Development of these mobile systems was supported by SRB9005 national project via Technical Cooperation of the IAEA. The first mobile system, built inside the 20 feet ISO container, will be used for conditioning of DSRS category 3 to 5. The second mobile system, built inside the 7 m long vehicle (Iveco Daily Van), will be used for dismantling of ionizing smoke detectors mostly with Am-241 sources. Designs of the mobile systems were defined in cooperation with two companies from Belgium (Belgoprocess and Leniko) and a Croatian company Ekoteh as well as with the support of the IAEA experts. The generic safety assessment and operational procedures for the mobile systems are developed. Based on safety assessment the acceptance criteria and operational limits and conditions are established. Operational procedures include: (a) equipment and material requirements, (b) assembling procedure of the mobile unit, (c) procedure for acceptance of devices for dismantling and conditioning, (d) dismantling procedure for devices to recover the DSRS, (e) characterization of DSRS, (f) encapsulation procedure of DSRS, (g) disassembling procedure of the mobile unit, and (h) keeping records, identification and traceability. In addition, radiation safety, health safety, security and emergency preparedness plans are prepared. The generic safety assessment and operational procedures could be updated with site specific requirements, DSRS inventory, and different needs for future customers. Developed mobile systems could be used in all situations when it is feasible to perform conditioning of DSRS on the spot in the county and worldwide. Development of these mobile units was just the first step to create the Reference Center for Radioactive Waste Treatment and Disused Radioactive Sources Conditioning for Small Facilities which can become a regional training center in the future, and/or as a tool for comprehensive national search and secure programmes. In the next phases development of e-learning platforms and blended learning packages as well as application for the IAEA Qualified Technical Centre (QTC) for the management of DSRS is foreseen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of the portable decay gamma source feature in the R2Smesh code system for the accurate estimation of photon radiation dose fields around activated ITER components - Paper 111

The R2Smesh ('Rigorous 2-step') code system, developed by KIT for the determination of shut-down dose rate distribution on mesh grid, can be utilized to provide photon radiation dose field around activated components which are moved from the irradiation site in fusion reactor to another external location. R2Smesh couples MCNP transport calculations and FISPACT inventory calculations through suitable interfaces utilizing MCNP mesh tally capability. Neutron flux and the decay gamma source are provided with high resolution on the mesh grid superimposed to the real geometry to take into account the spatial variations of the flux and the decay gamma source distributions. This feature enables the decay gamma source distribution to be transferred from the irradiation site in the reactor to any other external location for the determination of photon flux and dose rate distributions. In this work, we applied the feature of the portable decay gamma source in R2Smesh code system to a dose rate analysis for a tunnel connecting the ITER tokamak complex building (TCB) and the hot cell facility building (HCFB). This paper presents the use of the portability feature of the decay gamma source in R2Smesh interface code system developed by KIT for a dose rate analysis of the ITER tunnel connecting TCB and HCFB. This application shows that the decay gamma source of the activated components could be transferred successfully from one coordinate system to another coordinate system and superimposed to the geometry of the components. This is very useful when the activated components need to be transported from the reactor to somewhere else for maintenance, testing or storage and the dose rate analysis is requested. Another portable feature, which could convert the 3D decay gamma source distribution generated by R2Smesh system to the MCNP 'SDEF' card source description and avoid the use of source sampling subroutine, is under consideration. With this feature, one decay gamma source result for the specific reactor components could be shared by different institutions who need to use the same decay gamma source for different analysis. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Global threat reduction initiative efforts to address transportation challenges associated with the recovery of disused radioactive sealed sources - 10460

Proper disposition of disused radioactive sources is essential for their safe and secure management and necessary to preclude their use in malicious activities. Without affordable, timely transportation options, disused sealed sources remain in storage at hundreds of sites throughout the country and around the world. While secure storage is a temporary measure, the longer sources remain disused or unwanted the chances increase that they will become unsecured or abandoned. The Global Threat Reduction Initiative's Off-Site Source Recovery Project (GTRIlOSRP), recovers thousands of disused and unwanted sealed sources annually as part of GTRl's larger mission to reduce and protect high risk nuclear and radiological materials located at civilian sites worldwide. Faced with decreasing availability of certified transportation containers to support movement of disused and unwanted neutron- and beta/gamma-emitting radioactive sealed sources, GTRIlOSRP has initiated actions to ensure the continued success of the project in timely recovery and management of sealed radioactive sources. Efforts described in this paper to enhance transportation capabilities include: {sm_bullet} Addition of authorized content to existing and planned Type B containers to support the movement of non-special form and other Type B-quantity sealed sources; {sm_bullet} Procurement of vendor services for the design, development, testing and certification of a new Type B container to support transportation of irradiators, teletherapy heads or sources removed from these devices using remote handling capabilities such as the IAEA portable hot cell facility; {sm_bullet} Expansion of shielded Type A container inventory for transportation of gamma-emitting sources in activity ranges requiring use of shielding for conformity with transportation requirements; {sm_bullet} Approval of the S300 Type A fissile container for transport of Pu-239 sealed sources internationally; {sm_bullet} Technology transfer of field-sealable (non-welded) special form capsules for commercial use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A compact ion source and accelerator based on a piezoelectric driver

Compact ion sources and accelerators using piezoelectric devices for the production of energetic ion beams are being evaluated. A coupled source-accelerator is being tested as a neutron source to be incorporated into oil-well logging diagnostics. Two different ion sources are being investigated, including a piezoelectric transformer-based plasma source and a silicon-based field ion source. The piezoelectric transformer plasma ion source uses a cylindrical, resonantly driven piezoelectric crystal to produce high voltage inside a confined volume filled with low pressure deuterium gas. The plasma generated in the confined chamber is ejected through a small aperture into an evacuated drift region. The silicon field ion source uses localized electric field enhancement produced by an array of sharp emitters etched into a silicon blank to produce ions through field desorption ionization. A second piezoelectric device of a different design is used to generate an accelerating potential on the order of 130 kV; this potential is applied to a deuterated target plate positioned perpendicular to the ion stream produced by either plasma source. This paper discusses the results obtained by the individual components as they relate to the final neutron source.

07 ISOTOPE AND RADIATION SOURCES↗

Verification of Plutonium Content in PuBe Sources Using MCNP® 6.2.0 Beta with TENDL 2012 Libraries

Although the production of PuBe neutron sources has discontinued, hundreds of sources with unknown or inaccurately declared plutonium content are in existence around the world. Institutions have undertaken the task of assaying these sources, measuring, and calculating the isotopic composition, plutonium content, and neutron yield. The nominal plutonium content, based off the neutron yield per gram of pure 239 Pu, has shown to be highly inaccurate. New methods of measuring the plutonium content allow a more accurate estimate of the true Pu content, but these measurements need verification. Using the TENDL 2012 nuclear data libraries, MCNP6 has the capability to simulate the (α, n) interactions in a PuBe source. Theoretically, if the source is modeled according to the plutonium content, isotopic composition, and other source characteristics, the calculated neutron yield in MCNP can be compared to the experimental yield, offering an indication of the accuracy of the declared plutonium content. In this study, three sets of PuBe sources from various backgrounds were modeled in MCNP6 1.2 Beta, according to the source specifications dictated by the individuals who assayed the source. Verification of the source parameters with MCNP6 also serves as a means to test the alpha transport capabilities of MCNP6 1.2 Beta with TENDL 2012 alpha transport libraries. Finally, good agreement in the comparison would indicate the accuracy of the source parameters in addition to demonstrating MCNP's capabilities in simulating (α, n) interactions.

(α,n)↗

Source Characterization of the Declared North Korean Nuclear Tests From Regional Distance Coda Wave Spectral Ratios

Abstract Seismic observations of underground nuclear explosions provide crucial data on source yield and depth that cannot easily be estimated from other geophysical methods. However, it is difficult to obtain reliable yield estimates for test sites for which we do not have direct seismic calibration experiments. To obtain source information from uncalibrated sites and paths, local and regional seismic records of six, proximal, declared underground nuclear explosions in North Korea are used to compute spectral ratios of narrow‐band waveform envelopes of body‐wave coda that remove path and site effects to reveal precise, relative source moment. The yields of these explosions are obtained from the observed source ratios by simultaneously fitting the classical source model of Mueller and Murphy (1971), https://doi.org/10.1785/bssa0610061675 to all event pairs. The source model provides an impressive fit to the observations considering that the P phase coda derived source spectral ratios did not require a prior knowledge of the source or regionally calibrated corrections to be applied to the data. However, the observed corner frequencies from S wave coda spectral ratios are lower than the source model predictions, but are well fit by models calculated using the corner frequency consistent with the Fisk conjecture. The results presented here provide novel constraints on the spectral distributions of the energy radiated by the sources of the DPRK test series, and allows for an independent evaluation of existing estimated source model parameters.

58 GEOSCIENCES↗

Planck intermediate results: XXVII. High-redshift infrared galaxy overdensity candidates and lensed sources discovered by Planck and confirmed by Herschel -SPIRE

We have used the Planck all-sky submillimetre and millimetre maps to search for rare sources distinguished by extreme brightness, a few hundred millijanskies, and their potential for being situated at high redshift. These “cold” Planck sources, selected using the High Frequency Instrument (HFI) directly from the maps and from the Planck Catalogue of Compact Sources (PCCS), all satisfy the criterion of having their rest-frame far-infrared peak redshifted to the frequency range 353–857 GHz. This colour-selection favours galaxies in the redshift range z = 2–4, which we consider as cold peaks in the cosmic infrared background. With a 4'.5 beam at the four highest frequencies, our sample is expected to include overdensities of galaxies in groups or clusters, lensed galaxies, and chance line-of-sight projections. In this paper, we perform a dedicated Herschel-SPIRE follow-up of 234 such Planck targets, finding a significant excess of red 350 and 500μm sources, in comparison to reference SPIRE fields. About 94% of the SPIRE sources in the Planck fields are consistent with being overdensities of galaxies peaking at 350μm, with 3% peaking at 500μm, and none peaking at 250μm. About 3% are candidate lensed systems, all 12 of which have secure spectroscopic confirmations, placing them at redshifts z> 2.2. Only four targets are Galactic cirrus, yielding a success rate in our search strategy for identifying extragalactic sources within the Planck beam of better than 98%. The galaxy overdensities are detected with high significance, half of the sample showing statistical significance above 10σ. The SPIRE photometric redshifts of galaxies in overdensities suggest a peak at z ≃ 2, assuming a single common dust temperature for the sources of T d = 35 K. Under this assumption, we derive an infrared (IR) luminosity for each SPIRE source of about 4 × 10 12 L ⊙ , yielding star formation rates of typically 700 M ⊙ yr -1 . If the observed overdensities are actual gravitationally-bound structures, the total IR luminosity of all their SPIRE-detected sources peaks at 4 × 10 13 L ⊙ , leading to total star formation rates of perhaps 7 × 10 3 M ⊙ yr -1 per overdensity. Taken together, these sources show the signatures of high-z (z> 2) protoclusters of intensively star-forming galaxies. Finally, all these observations confirm the uniqueness of our sample compared to reference samples and demonstrate the ability of the all-skyPlanck-HFI cold sources to select populations of cosmological and astrophysical interest for structure formation studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization and variability of compact sources measured in Planck time-ordered data

This paper introduces a new Planck Catalog of Polarized and Variable Compact Sources (PCCS-PV) comprising 153 sources, the majority of which are extragalactic. The data include both the total flux density and linear polarization measured by Planck with frequency coverage from 30 to 353 GHz, and temporal spacing ranging from days to years. We classify most sources as beamed, extragalactic radio sources; the catalog also includes several radio galaxies, Seyfert galaxies, and Galactic and Magellanic Cloud sources, including H II regions and planetary nebulae. An advanced extraction method applied directly to the multifrequency Planck time-ordered data, rather than the mission sky maps, was developed to allow an assessment of the variability of polarized sources. Our analysis of the time-ordered data from the Planck mission, tod2flux, allowed us to catalog the time-varying emission and polarization properties for these sources at the full range of polarized frequencies employed by Planck, 30-353 GHz. PCCS-PV provides the time-and frequency-dependent, polarized flux densities for all 153 sources. To illustrate some potential applications of the PCCS-PV, we conducted preliminary comparisons of our measurements of selected sources with published data from other astronomical instruments. In summary, we find general agreement between the Planck and the Institut de Radioastronomie Millimétrique (IRAM) polarization measurements as well as with the Metsähovi 37 GHz values at closely similar epochs. Here, these combined measurements also show the value of PCCS-PV results and the PCCS2 catalog for filling in missing spectral (or temporal) coverage and helping to define the spectral energy distributions of extragalactic sources. In turn, these results provide useful clues as to the physical properties of the sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Retrieval, Disposal, and Disposition of Legacy 252 Cf Sealed Sources

In this article, we describe work performed on behalf of the US Department of Energy (DOE) to disposition 467 government-owned, sealed californium-252 ( 252 Cf) sources located at 52 academic and government research sites. These sources are the legacy of the DOE 252 Cf Loan/Lease Program, which operated from the late 1960s until 2008, when the loan program closed abruptly. Although the DOE took decades to fabricate and distribute the sources, best safety and nuclear accountability practices demanded retrieval or disposition of all loaned sources as soon as achievable after the loan program was closed. An adaptable disposition approach was developed, and disposition of the sources was pursued. The approach involved a combination of source retrievals, disposal actions, and source ownership transfers. A new shielded shipping container was designed and deployed to aid in source retrievals. In a couple cases, incomplete source fabrication and shipping records prevented shipment, and those sources were left indefinitely with the customer in a safe configuration. Lastly, all the sources in the inventory were safely dispositioned in some way, and lessons learned from this effort are provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GALAXY CLUSTER ENVIRONMENTS OF RADIO SOURCES

Using the Sloan Digital Sky Survey (SDSS) and the Faint Images of the Radio Sky at Twenty Centimeters (FIRST) catalogs, we examined the optical environments around double-lobed radio sources. Previous studies have shown that multi-component radio sources exhibiting some degree of bending between components are likely to be found in galaxy clusters. Often this radio emission is associated with a cD-type galaxy at the center of a cluster. We cross-correlated the SDSS and FIRST catalogs and measured the richness of the cluster environments surrounding both bent and straight multi-component radio sources. This led to the discovery and classification of a large number of galaxy clusters out to a redshift of z {approx} 0.5. We divided our sample into smaller subgroups based on their optical and radio properties. We find that FR I radio sources are more likely to be found in galaxy clusters than FR II sources. Further, we find that bent radio sources are more often found in galaxy clusters than non-bent radio sources. We also examined the environments around single-component radio sources and find that single-component radio sources are less likely to be associated with galaxy clusters than extended, multi-component radio sources. Bent, visually selected sources are found in clusters or rich groups {approx}78% of the time. Those without optical hosts in SDSS are likely associated with clusters at even higher redshifts, most with redshifts of z>0.7.

79 ASTRONOMY AND ASTROPHYSICS↗

VLA observations of NGC 247: identification of compact radio sources including three candidate UD H II regions

A high resolution, Very Large Array continuum survey of NGC 247 was undertaken in order to identify compact thermal and nonthermal radio sources, such as supernova remnants (SNRs) and H II regions. NGC 247 was observed at two frequencies, 20 cm and 6 cm, in order to calculate the spectral index, and the survey resulted in the identification of 19 compact radio sources. Using the spectral index to discriminate between source types, we identify two candidate SNRs and one H II region. Three of the radio sources have inverted spectra, indicative of ultradense H II (UD H II) regions, the short-lived, dense cores where massive stars form. Four of the sources are thermal in origin, but were not detected at 20 cm, so they could be H II regions or UD H II regions. The rest of the sources are nonthermal or undetermined. We compare the radio images with Hα, V band, and infrared archive images to look for correspondences that confirm that the sources reside in NGC 247 and are not background sources. We find that over two-thirds of the radio sources have counterparts in the Hα or V band images and are associated with NGC 247. The most luminous radio source in NGC 247 is a candidate SNR, and if confirmed as an SNR, it would be a very luminous extragalactic SNR. The H II regions and UD H II regions are calculated to have ionizing luminosities of between 4-10 × 10{sup 50} s{sup –1}; each individual source would require between 41-100 O7.5V stars to produce the corresponding ionizing luminosity. The ionizing luminosity of the UD H II regions indicates that these UD H II regions represent the lower luminosity population of the known UD H II regions and thus, they may represent a more typical population of UD H II regions that can be found and studied in the nearby galaxies as opposed to more extreme examples that have been found previously.

79 ASTRONOMY AND ASTROPHYSICS↗