Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software structure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Best Practices for Finite Element Analysis of Spent Nuclear Fuel Transfer, Storage, and Transportation Systems

Storage casks and transportation packages for spent nuclear fuel (SNF) are designed to confine SNF in sealed canisters or casks, provide structural integrity during accidents, and remove decay through a storage or transportation overpack. The transfer, storage, and transportation of SNF in dry storage casks and transport packages is regulated under 10 CFR Part 72 and 10 CFR Part 71, respectively. Finite Element Analysis (FEA) is used with increasing frequency in Safety Analysis Reports and other regulatory technical evaluations related to SNF casks and packages and their associated systems. Advances in computing power have made increasingly sophisticated FEA models more feasible, and as a result, the need for careful review of such models has also increased. This paper identifies best practice recommendations that stem from recent NRC review experience. The scope covers issues common to all commercially available FEA software, and the recommendations are applicable to any FEA software package. Three specific topics are addressed: general FEA practices, issues specific to thermal analyses, and issues specific to structural analyses. General FEA practices covers appropriate documentation of the model and results, which is important for an efficient review process. The thermal analysis best practices are related to cask analysis for steady state conditions and transient scenarios. The structural analysis best practices are related to the analysis of casks and associated payload during standard handling and drop scenarios. The best practices described in this paper are intended to identify FEA modeling issues and provide insights that can help minimize associated uncertainties and errors, in order to facilitate the NRC licensing review process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Polymorphism of ScBO{sub 3} at the Solid Phase Synthesis from Amorphous Precursors

Detailed X-ray studies of changes in the structure of the scandium orthoborate ScBO{sub 3} in the process of serial isothermal annealing of the initial charge in the form of amorphous precursor were carried out. It was shown that upon successive annealing of the amorphous precursor, the crystalline phase first forms at an annealing temperature of 710°C, the positions of the reflections of which do not coincide with the positions that of the known calcite structure. This phase exists in a very narrow temperature range (≈30°C) and, when the annealing temperature is increased to 750°C, it completely transfers to the known rhombohedral phase of calcite. Using the ENDEAVOR software, the cell parameters, atom positions in the cell, and the spatial symmetry group of the new phase were determined. It turned out that the new phase corresponds to the hexagonal structure of the faterite (S.G. P63/mmc), known for other orthoborates of rare-earth elements (REE).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MISPR : an open-source package for high-throughput multiscale molecular simulations

Computational tools provide a unique opportunity to study and design optimal materials by enhancing our ability to comprehend the connections between their atomistic structure and functional properties. However, designing materials with tailored functionalities is complicated due to the necessity to integrate various computational-chemistry software (not necessarily compatible with one another), the heterogeneous nature of the generated data, and the need to explore vast chemical and parameter spaces. The latter is especially important to avoid bias in scattered data points-based models and derive statistical trends only accessible by systematic datasets. Here, we introduce a robust high-throughput multi-scale computational infrastructure coined MISPR (Materials Informatics for Structure–Property Relationships) that seamlessly integrates classical molecular dynamics (MD) simulations with density functional theory (DFT). By enabling high-performance data analytics and coupling between different methods and scales, MISPR addresses critical challenges arising from the needs of automated workflow management and data provenance recording. The major features of MISPR include automated DFT and MD simulations, error handling, derivation of molecular and ensemble properties, and creation of output databases that organize results from individual calculations to enable reproducibility and transparency. In this work, we describe fully automated DFT workflows implemented in MISPR to compute various properties such as nuclear magnetic resonance chemical shift, binding energy, bond dissociation energy, and redox potential with support for multiple methods such as electron transfer and proton-coupled electron transfer reactions. The infrastructure also enables the characterization of large-scale ensemble properties by providing MD workflows that calculate a wide range of structural and dynamical properties in liquid solutions. MISPR employs the methodologies of materials informatics to facilitate understanding and prediction of phenomenological structure–property relationships, which are crucial to designing novel optimal materials for numerous scientific applications and engineering technologies.

36 MATERIALS SCIENCE↗

Assessing the reliability of the NIST library during routine GC-MS analyses: Structure and spectral data corroboration for 5,5-diphenyl-1,3-dioxolan-4-one during a recent OPCW proficiency test

In the field of analytical chemistry, it is the nature of the available instrumentation that makes a specific technique uniquely suited for answering a specific challenge. Often times, instruments equipped with ultrasensitive array of detectors and state-of-the-art separation components have served to highlight their invaluable role in the field. Nonetheless, it is their ultimate ability to predict the structure of an unknown material on the basis of mass spectral data that exponentially magnifies their value. Their efficacy in achieving this prediction is largely based on the size of their internal mass spectral library that conveniently can be accessed by using the software. The library can thus exhaustively correlate an unknown compound's mass spectrum to known compounds in a database and provide the analytical chemist with a probable structure for the unknown analyte. During routine analysis, it is customary that after the appropriate collection of the compound's mass spectrum, the next step involves its comparison with a compound in the instrument's National Institute of Standards and Technology (NIST) library.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New hardware and software platform for experiments on a HUBER-5042 X-ray diffractometer with a DISPLEX DE-202 helium cryostat in the temperature range of 20–300 K

Huber-5042 diffractometer with a closed-cycle Displex DE-202 helium cryostat is a unique scientific instrument for carrying out X-ray diffraction experiments when studying the single crystal structure in the temperature range of 20–300 K. To make the service life longer and develop new experimental techniques, the diffractometer control is transferred to a new hardware and software platform. To this end, a modern computer; a new detector reader unit; and new control interfaces for stepper motors, temperature controller, and cryostat vacuum pumping system are used. The system for cooling the X-ray tube, the high-voltage generator, and the helium compressor and pump for maintaining the desired vacuum in the cryostat are replaced. The system for controlling the primary beam shutter is upgraded. A biological shielding is installed. The new program tools, which use the Linux Ubuntu operating system and SPEC constructor, include a set of drivers for control units through the aforementioned interfaces. A program for searching reflections from a sample using fast continuous scanning and a priori information about crystal is written. Thus, the software package for carrying out the complete cycle of precise diffraction experiment (from determining the crystal unit cell to calculating the integral reflection intensities) is upgraded. High quality of the experimental data obtained on this equipment is confirmed in a number of studies in the temperature range from 20 to 300 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Discrete Fracture Network Models for Risk Assessment of Carbon Sequestration in Coal

A software package called DFNModeler has been developed to assess the potential risks associated with carbon sequestration in coal. Natural fractures provide the principal conduits for fluid flow in coal-bearing strata, and these fractures present the most tangible risks for the leakage of injected carbon dioxide. The objectives of this study were to develop discrete fracture network (DFN) modeling tools for risk assessment and to use these tools to assess risks in the Black Warrior Basin of Alabama, where coal-bearing strata have high potential for carbon sequestration and enhanced coalbed methane recovery. DFNModeler provides a user-friendly interface for the construction, visualization, and analysis of DFN models. DFNModeler employs an OpenGL graphics engine that enables real-time manipulation of DFN models. Analytical capabilities in DFNModeler include display of structural and hydrologic parameters, compartmentalization analysis, and fluid pathways analysis. DFN models can be exported to third-party software packages for flow modeling. DFN models were constructed to simulate fracturing in coal-bearing strata of the upper Pottsville Formation in the Black Warrior Basin. Outcrops and wireline cores were used to characterize fracture systems, which include joint systems, cleat systems, and fault-related shear fractures. DFN models were constructed to simulate jointing, cleating, faulting, and hydraulic fracturing. Analysis of DFN models indicates that strata-bound jointing compartmentalizes the Pottsville hydrologic system and helps protect shallow aquifers from injection operations at reservoir depth. Analysis of fault zones, however, suggests that faulting can facilitate cross-formational flow. For this reason, faults should be avoided when siting injection wells. DFN-based flow models constructed in TOUGH2 indicate that fracture aperture and connectivity are critical variables affecting the leakage of injected CO{sub 2} from coal. Highly transmissive joints near an injection well have potential to divert a large percentage of an injected CO{sub 2} stream away from a target coal seam. However, the strata-bound nature of Pottsville fracture systems is a natural factor that mitigates the risk of long-range leakage and surface seepage. Flow models indicate that cross-formational flow in strata-bound joint networks is low and is dissipated by about an order of magnitude at each successive bedding contact. These models help confirm that strata-bound joint networks are self-compartmentalizing and that the thick successions of interbedded shale and sandstone separating the Pottsville coal zones are confining units that protect shallow aquifers from injection operations at reservoir depth. DFN models are powerful tools for the simulation and analysis of fracture networks and can play an important role in the assessment of risks associated with carbon sequestration and enhanced coalbed methane recovery. Importantly, the stochastic nature DFN models dictates that they cannot be used to precisely reproduce reservoir conditions in a specific field area. Rather, these models are most useful for simulating the fundamental geometric and statistical properties of fracture networks. Because the specifics of fracture architecture in a given area can be uncertain, multiple realizations of DFN models and DFN-based flow models can help define variability that may be encountered during field operations. Using this type of approach, modelers can inform the risk assessment process by characterizing the types and variability of fracture architecture that may exist in geologic carbon sinks containing natural fractures.

01 COAL, LIGNITE, AND PEAT↗

ORIGEN Integration into MPACT

This report documents the work performed to meet the objectives of the RTM milestone on ORIGEN Integration into MPACT. The main objective of the milestone was to demonstrate the capability to perform depletion problems with MPACT where the point depletion calculation, which solves the nuclide transmutation equation with ORIGEN. While MPACT already has a depletion capability based on ORIGEN, it is desired to transition to using ORIGEN because ORIGEN has undergone far more validation and software quality assurance than the implementation in MPACT. The integration was completed by compiling and linking the two codes together at build-time. Within the TriBITS build structure used for VERA, the MPACT and SCALE code repositories are already present. An optional dependency was created between MPACT to SCALE. The API available within ORIGEN was modified slightly to be able to be used by MPACT and two new software classes were implemented in MPACT to call the necessary ORIGEN subroutines. To test the ORIGEN integration two benchmark problems were analyzed. The first being the spent fuel isotopics from the Takahama-3 PWR reactor. This involved comparisons to experimentally measured nuclide concentrations for select actinides and fission products, and comparisons to other numerical results. The benchmark defines a 1-D problem limiting most of the effects due to the accuracy of a multi-dimensional transport solver, and thus differences can be assumed to be more likely caused by the point depletion solver methodology and associated nuclear data. The other benchmark analyzed two problems from the reactor physics benchmarks for LWR next generation fuel. The two configurations simulated were a PWR UO 2 pin cell and PWR UO 2 assembly. For all the benchmark problems the results were generally in good agreement with the other numerical results which were computed by several codes, including MPACT with its original depletion implementation. Thus it is concluded that ORIGEN was successfully integrated into MPACT and is capable of providing reasonable results. An additional cursory analysis of the performance of the ORIGEN point depletion compared to native MPACT point depletion solver was also performed. In this analysis it was observed that ORIGEN, on average, needs about 0.28 to 0.30 seconds to perform the point depletion calculation. This is greater than the target performance of 0.1 seconds which means future work to investigate smaller depletion chains will be needed. The MPACT internal depletion solver completes the point depletion calculation in 0.02 seconds, so it may be used for routine analysis until the use of a simplified burnup chain and performance improvements are implemented. Other future work should focus on implementing the post-correction fix-up and quadratic depletion and computation of decay heat and gamma sources.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Stigmergy Collaboration Approach in the Open Source Software Developer Community

The communication model of some self-organized online communities is significantly different from the traditional social network based community. It is problematic to use social network analysis to analyze the collaboration structure and emergent behaviors in these communities because these communities lack peer-to-peer connections. Stigmergy theory provides an explanation of the collaboration model of these communities. In this research, we present a stigmergy approach for building an agent-based simulation to simulate the collaboration model in the open source software (OSS) developer community. We used a group of actors who collaborate on OSS projects through forums as our frame of reference and investigated how the choices actors make in contributing their work on the projects determines the global status of the whole OSS project. In our simulation, the forum posts serve as the digital pheromone and the modified Pierre-Paul Grasse pheromone model is used for computing the developer agents behavior selection probability.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-461: Validation of Planning Algorithms in Dynamic Conformal Arc in IPlan Using ArcCHECK and 3DVH

Purpose: To study the effect of limited angular resolution of pencil beam calculation (PBC) on dynamic conformal arc plan (DCAP) in iPlan (BrainLab) using the ArcCHECK sytem and 3DVH software (Sun Nuclear Corporation). Methods: Four DCAPs were generated in iPlan RT Dose 4.5 treatment planning system on the ArcCHECK cylindrical phantom with central planning target volume (PTV). A cylindrical shell structure (SHELL) 2.85cm from phantom surface and 1.5 mm thickness was created to simulate the ArcCHECK diode array. Planned doses were calculated using both Monte Carlo calculation (MCC) and PBC algorithms, and exported to 3DVH software for global and target based comparisons using the 3Dgamma index. Four additional DCAPs were created and calculated on patient CT images and mapped onto the ArcCHECK phantom for measurement using a Varian TrueBeam STx. The measurements were compared against both MC and PB calculation using gamma index analysis. Results: For the ArcCHECK phantom, the dose distribution agreement quantified with 3D-gamma index is better (average-gamma (<γ>)=99.9%vs.79.1% and 96.8%vs45.7%, p=0.0294, 0.0286 for gamma (2mm,2%) and (1mm,1%) criteria respectively using Mann-Whitney U test) in the PTV than in the SHELL. The measurements show better agreement with MCC than the PB (<γ>=100%vs.86.7%, 99.6%vs.72.3%, 85.5%vs.50.8%, p=0.021, 0.026, 0.029 for gamma (3mm,3%), (2mm,2%) and (1mm,1%) criteria using Mann-Whitney U test respectively). The effect due to limited (10 degree) angular resolution of the PBC was observed, and it can be one of the possible reasons for poor agreement between measurement and PB calculation. Conclusion: The PBC of iPlan shows poor peripheral dose calculation accuracy for dynamic conformal arc plans due to limited angular resolution, but it performs well in the area close to target volume without considering heterogeneity. Since the user cannot change the 10 degree angular resolution of PBC, MCC is more appropriate for dynamic conformal arc plans.

60 APPLIED LIFE SCIENCES↗

Generating SBoMs Utilizing Structured Threat Information Expression JSON bundles

With cyber-attacks on the rise, information is one of the first lines of defense. Now more than ever, security experts and developers need efficient ways to know if their software may be outdated or vulnerable to emerging threats. By generating a Software Bill of Material based on STIX2/JSON bundles, security experts and developers can ensure that they know where to find what can go wrong with their systems before the hackers do. As part of the Infrastructure Expression project, Idaho National Laboratory (INL) is currently working on ways that can aid in the development of efficient SBOMs using Structured Threat Information Expression (STIX). Doing so can provide an efficient first line of defense for detection and monitoring that can be easily used by cyber personnel from beginners to highly skilled experts.

97 MATHEMATICS AND COMPUTING↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

ZMPY3D: accelerating protein structure volume analysis through vectorized 3D Zernike moments and Python-based GPU integration

Abstract Motivation Volumetric 3D object analyses are being applied in research fields such as structural bioinformatics, biophysics, and structural biology, with potential integration of artificial intelligence/machine learning (AI/ML) techniques. One such method, 3D Zernike moments, has proven valuable in analyzing protein structures (e.g., protein fold classification, protein–protein interaction analysis, and molecular dynamics simulations). Their compactness and efficiency make them amenable to large-scale analyses. Established methods for deriving 3D Zernike moments, however, can be inefficient, particularly when higher order terms are required, hindering broader applications. As the volume of experimental and computationally-predicted protein structure information continues to increase, structural biology has become a “big data” science requiring more efficient analysis tools. Results This application note presents a Python-based software package, ZMPY3D, to accelerate computation of 3D Zernike moments by vectorizing the mathematical formulae and using graphical processing units (GPUs). The package offers popular GPU-supported libraries such as CuPy and TensorFlow together with NumPy implementations, aiming to improve computational efficiency, adaptability, and flexibility in future algorithm development. The ZMPY3D package can be installed via PyPI, and the source code is available from GitHub. Volumetric-based protein 3D structural similarity scores and transform matrix of superposition functionalities have both been implemented, creating a powerful computational tool that will allow the research community to amalgamate 3D Zernike moments with existing AI/ML tools, to advance research and education in protein structure bioinformatics. Availability and implementation ZMPY3D, implemented in Python, is available on GitHub (https://github.com/tawssie/ZMPY3D) and PyPI, released under the GPL License.

Lai, Jhih-Siang (ORCID:0000000156775890)↗

The interatomic vector's method, algorithms, and programs for the solution of atomic structure of nanoclusters in crystal

A calculation technique and corresponding algorithms have been developed using the formalism of Fourier transform of finite functions. A software package for obtaining distributions of cluster interatomic vectors from diffuse X-ray scattering has been written and debugged. The programs were checked on a 30-atom cluster [CdTb{sub 3}F{sub 26}]. The attempts to obtain experimental data on a single crystal with nanoclusters using an Xcalibur S diffractometer (Oxford Diffraction) with a coordinate CCD detector were no success. The standard diffractometer software contains errors that lead to incorrect results upon the reconstruction of the distribution of diffuse scattering from different runs. These errors are of little importance when Bragg peaks are processed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

Present status of SPring-8 macromolecular crystallography beamlines

Seven beamlines are operated for macromolecular crystallography (MX) at SPring-8. The three undulator beamlines are developed for cutting edge target and four bending-magnet beamlines are developed for high throughput MX. The undulator beamline, BL41XU that provides the most brilliant beam, is dedicated to obtain high quality data even from small-size and weakly-diffracting crystals. The minimum beam size at sample position is achieved to 10 {mu}m diameter using a pin-hole collimator. Its photon flux at wavelength {lambda} = 1.0 A is 2.8x10{sup 11} photons/sec. This small beam coupled with irradiation point scanning method is quite useful to take diffraction dataset from small crystals by suppressing the radiation damage. These advanced technologies made a number of difficult protein structure analysis possible, (i.e. Sodium-potassium ATPase). The bending-magnet beamlines BL26B1/B2 and BL38B1 provide automatic data collection exploiting the high mobility of the beam. The beamline operation software 'BSS', sample auto-changer 'SPACE' and web-based data management software 'D-Cha' have made the automatic data collection possible. The 'Mail-in data collection system' that accepts distant users samples via courier service have made users possible to collect diffraction data without visiting SPring-8. The structural genomics research is promoted by these beamlines.

43 PARTICLE ACCELERATORS↗

Data File Standard for Flow Cytometry, Version FCS 3.1

The flow cytometry data file standard provides the specifications needed to completely describe flow cytometry data sets within the confines of the file containing the experimental data. In 1984, the first Flow Cytometry Standard format for data files was adopted as FCS 1.0. This standard was modified in 1990 as FCS 2.0 and again in 1997 as FCS 3.0. We report here on the next generation flow cytometry standard data file format. FCS 3.1 is a minor revision based on suggested improvements from the community. The unchanged goal of the standard is to provide a uniform file format that allows files created by one type of acquisition hardware and software to be analyzed by any other type. The FCS 3.1 standard retains the basic FCS file structure and most features of previous versions of the standard. Changes included in FCS 3.1 address potential ambiguities in the previous versions and provide a more robust standard. The major changes include simplified support for international characters and improved support for storing compensation. The major additions are support for preferred display scale, a standardized way of capturing the sample volume, information about originality of the data file, and support for plate and well identification in high throughput, plate based experiments. Please see the normative version of the FCS 3.1 specification in Supporting Information for this manuscript (or at http://www.isac-net.org/ in the Current standards section) for a complete list of changes.

59 BASIC BIOLOGICAL SCIENCES↗

A parallel and performance portable implementation of a full-field crystal plasticity model

We have developed a parallel implementation of an Elasto-Viscoplastic Fast Fourier Transform-based (EVPFFT) micromechanical solver to enable computationally efficient crystal plasticity modeling for polycrystalline materials. Our primary focus lies in achieving performance portability, allowing a single EVPFFT implementation to run optimally on various homogeneous architectures, including multi-core Central Processing Units (CPUs), as well as on heterogeneous computer architectures comprising multi-core CPUs and Graphics Processing Units (GPUs) from different vendors. To accomplish this goal, we have leveraged MATAR, a C++ software library that simplifies the creation and utilization of multidimensional dense or sparse matrix and array data structures. These data structures are designed to be portable across diverse architectures through the use of Kokkos, a performance-portable library. Additionally, we have employed the Message Passing Interface (MPI) to efficiently distribute the computational workload among processors. The heFFTe (Highly Efficient FFT for Exascale) library is used to facilitate the performance portability of the fast Fourier transforms (FFTs) computation. The computational performance of EVPFFT is evaluated and presented in terms of parallel scalability and simulation runtime on different high-performance computing (HPC) architectures. As a result, the utility of the developed framework to efficiently simulate the micro-mechanical fields in polycrystalline microstructures in engineering applications is discussed.

36 MATERIALS SCIENCE↗

Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to planning target volume (PTV) margins for planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗