Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Compositionally graded aluminum-silicon alloy fabricated via friction extrusion

Herein, a novel solid-phase gradient alloying technique was developed for a high throughput composition-microstructure-mechanical property assessment. Friction extrusion of a two-piece billet setup facilitated the formation of a seamless compositionally graded aluminum (Al)-silicon (Si) extrudate rod, with Si concentration in Al matrix gradually increasing from ~1 at% at one end to ~7 at% at the other end of the rod. We observed a strong dependence of the Al grain size, morphology, and texture on the Si concentration. The Si particles pinned the recrystallized grain boundaries resulting in refined (< 10 µm) and textured grains in the high Si content region, while the Al grains in the low Si region are equiaxed, randomly textured, and with a larger average size (~50 µm). The hardness of Al-Si gradient extrudate increases by ~50% percent with a 6 at% increase in Si content due to Hall Petch and particle strengthening effects. Our approach demonstrates the use of a solid phase processing technique to successfully produce a defect-free continuously compositionally graded bulk components thus overcoming the limitations of porosity and material heterogeneities commonly observed in other techniques such as by additive laser deposition.

36 MATERIALS SCIENCE↗

Combining four-point bending and corrosion to map stress-dependent corrosion susceptibility of 316H stainless steel in FLiNaK

Understanding the effect of stress on the corrosion of steels in molten salts is important for material screening and safety assessment of molten salt reactors. We present a method that combines four-point bending with corrosion testing, enabling the mapping of corrosion susceptibility as a function of local stress from a single specimen. Guided by finite element analysis, a four-point bending setup was used to bend a 316H stainless-steel bar under controlled elastic stress during a 100-hour exposure in FLiNaK at 700 °C. Post-exposure characterization using scanning electron microscopy and energy-dispersive X-ray spectroscopy revealed a pronounced correlation between stress and corrosion. Regions under tensile stress exhibited significantly deeper attack depths and greater chromium depletion along grain boundaries, whereas compressive zones showed shallower corrosion cracks. The stress effect is attributed to stress concentration under tensile loading, which promotes chromium dissolution and crack propagation. This technique can be readily applied to other structural alloys, enabling quantitative measurement of corrosion susceptibility as a function of local stress.

316H↗

Direct ink writing of shear exfoliated two-dimensional nanomaterial- elastomeric multifunctional nanocomposite

Direct ink writing (DIW) of polymer nanocomposites with high loadings of two-dimensional (2D) nanofillers (graphene and hexagonal boron nitride (hBN)) is challenging because of potential clogging, use of hazardous solvents, and agglomeration. Here, in this work, a shear exfoliation and sieving method to prepare DIW ink with high loading of nanofillers produced from low-cost bulk layered materials such as graphite and bulk hBN powder for successful DIW printing without the use of any solvents, binders, or plasticizers. The single-step exfoliation technique resulted in a composite with substantial layer reduction along the c-axis, as confirmed by SEM, TEM, XRD, and Raman analysis. Incorporating exfoliated graphene (40 wt%) increased viscosity by ∼6 orders of magnitude due to enhanced particle–matrix interactions, leading to pronounced yield stress behavior and a yield stress of approximately 1598 Pa, which enabled excellent shape retention during extrusion. Using the DIW technique, porous structures such as desalination membranes, self-sensing bone scaffolds, thermal management coating, and serpentine strain sensors were fabricated. When tested in a direct contact membrane distillation setup, the fabricated membrane demonstrated a promising permeate flux of 21.85 Lm −2 h −1 and a salt rejection of 74.3 %. The fabricated serpentine sensor exhibited stable signal variations under cyclic tensile loading, with a working range of 0–200 % strain and a maximum gauge factor of 43,735. A cell culture test using the printed bone scaffold demonstrated promising cell attachment and proliferation. The DIW printed hBN nanocomposite exhibited reversible shape change under heat, demonstrating potential 4D printing capability and efficient thermal management when exposed to high heat or flame.

Desalination↗

Anomalous neutron nuclear-magnetic interference spectroscopy

The electron–phonon interaction plays a critical role in materials’ electrical, thermal, optical, and superconducting properties. However, measuring the phonon mode-resolved electron–phonon interaction has been challenging. Here we propose neutron-scattering-based Anomalous Neutron nUclear-Magnetic Interference Spectroscopy (ANUBIS), where the co-existence of neutron nuclear scattering and magnetic scattering leads to anomalous dynamical structure factor under the presence of the electron–phonon interaction. Such anomalous structure factor is linear in electron–phonon coupling constant at the phonon wavevector, and is directly proportional to the momentum and energy-resolved dielectric function. The experimental configuration can be achieved using existing polarized inelastic neutron scattering setup, and an order-of-magnitude estimate shows the viability to observe the anomalous scattering signal is around to 10 –4 to 10 –3 relative to phonon scattering, which is examined through the preliminary experiments and achievable at emerging neutron facilities. As a result, our proposal offers an alternative neutron-based metrology to probe the crucial electronic properties.

Electron-phonon interactions↗

An implantable biomechanical energy harvester for animal monitoring devices

Insufficient service life and the resulting need for battery replacements have been a great challenge for implantable electronic devices. This is particularly true for animal tracking applications, because recapturing animals is often unlikely once they are released to the wild. To tackle this problem, we developed a biomechanical energy harvester that uses a Macro Fiber Composite™ (MFC) piezoelectric beam to harvest the mechanical energy from animals’ body bending movements as the power source for implantable and wearable devices. Prototypes of an underwater acoustic transmitter using this technology were subdermally implanted into juvenile white sturgeon and their energy harvesting performance was evaluated through the device’s transmissions. Additionally, the fish successfully recovered from the implantation surgery and freely swam inside a tank. The transmitter prototypes in the fish continually transmitted signals for a period up to 5 weeks. A benchtop test setup was also created to emulate the fish’s body bending, estimate the device’s energy harvesting performance in the live fish, and perform accelerated fatigue testing of the energy harvester by applying test parameters learned from a video study of the fish’s body movement and behavior characteristics. The gradual depolarization of the piezoelectric ceramic material in the MFC under cyclic mechanical loading was the main limiting factor for the life span of the energy harvester. Pathways for improvement are proposed to achieve long-term efficacy of powering implantable and wearable electronic devices.

42 ENGINEERING↗

237 Np Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 237 Np. Fission was induced in a NpO 2 (NO 3 ) target using the Godiva IV critical assembly in burst mode. The irradiated sample was transferred to a high-resolution γ-ray detection setup within 50 minutes. γ-ray list mode data was collected from 50 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. Finally, the initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial tests of large format sensors for the ATLAS ITk strip tracker

For the construction of the Inner Tracker (ITk) as part of the phase-II upgrade programme of the ATLAS detector for the High-Luminosity (HL) LHC, batches of Long Strip (LS) and Short Strip (SS) n + -in-p type micro-strip sensors have been produced by Hamamatsu Photonics and Infineon. The full size sensors measure approximately 98 × 98 mm 2 and are designed and engineered for tolerance against the 9.7 × 10 14 1 MeV n eq /cm 2 fluence expected at the HL-LHC, including a safety factor of 1.5. Each sensor has 2 or 4 columns of 1280 individual channels arranged at 75.5 μ m horizontal pitch. To ensure the sensors comply with their specifications, a Quality Control (QC) procedure has been implemented, comprising measurements on every individual sensor as well as on a sample basis. Every sensor is subjected to an initial visual inspection, after which the full surface of the sensor is captured with very high resolution by an automated camera setup. Non-contact metrology is performed to obtain the sensor surface profile. Electrical measurements establishing the reverse bias leakage current and depletion voltage are then conducted automatically. Sample sensors from every batch are subjected to 40 h of leakage stability checks in controlled atmosphere, and tests on every channel measuring leakage current, coupling capacitance and bias resistance are done. The recorded results are uploaded to a production database following data quality checks. In this paper, QC test validation data and the compiled results for the first batches of production grade sensors are presented. The QC protocol was validated, and the first production sensors were confirmed to be within specification. The results are compared to those from the previous generation of prototype sensors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resistive AC-Coupled Silicon Detectors: principles of operation and first results from a combined analysis of beam test and laser data

This paper presents the principles of operation of Resistive AC-Coupled Silicon Detectors (RSDs) and measurements of the temporal and spatial resolutions using a combined analysis of laser and beam test data. RSDs are a new type of n-in-p silicon sensor based on the Low-Gain Avalanche Diode (LGAD) technology, where the n+ implant has been designed to be resistive, and the read-out is obtained via AC-coupling. The truly innovative feature of RSD is that the signal generated by an impinging particle is shared isotropically among multiple read-out pads without the need for floating electrodes or an external magnetic field. Careful tuning of the coupling oxide thickness and the n+ doping profile is at the basis of the successful functioning of this device. Several RSD matrices with different pad width-pitch geometries have been extensively tested with a laser setup in the Laboratory for Innovative Silicon Sensors in Torino, while a smaller set of devices have been tested at the Fermilab Test Beam Facility with a 120 GeV/c proton beam. The measured spatial resolution ranges between 2.5μm for 70–100 pad-pitch geometry and 17μm with 200–500 matrices, a factor of 10 better than what is achievable in binary read-out (bin size/12). Beam test data show a temporal resolution of ~40ps for 200 μm pitch devices, in line with the best performances of LGAD sensors at the same gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel experimental system for the KDK measurement of the 40 K decay scheme relevant for rare event searches

Potassium-40 ( 40 K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. 40 K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpretingcertain results or can lead to lack of precision depending on the field and analysis technique. Additionally, the KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited 40 K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr 2 I 5 :Eu scintillator as source and detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SHarD: A beam dynamics simulation code for dielectric laser accelerators based on spatial harmonic field expansion

In order to demonstrate acceleration of electrons to relativistic scales by an on chip dielectric laser accelerator (DLA), a ponderomotive focusing scheme capable of capturing and transporting electrons through nanometer-scale apertures over extended interaction lengths has been proposed. Here we present a Matlab-based numerical code (SHarD) utilizing a spatial harmonic expansion of the fields within the dielectric structure to simulate the evolution of the beam phase space distribution in this scheme. The code can be used to optimize key-parameters for the accelerator performance such as the final energy, transverse spot size evolution and total number of electrons accelerated through currently fabricated structures. Eventually, the simulation model will be applied to inform the phase mask profile to be added to a pulse front tilt drive laser pulse using a liquid crystal mask in the experimental setup being assembled at UCLA Pegasus Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DGFRS-2—A gas-filled recoil separator for the Dubna Super Heavy Element Factory

The main goal of development of the new Dubna Gas-Filled Recoil Separator (DGFRS-2) is to sufficiently improve the efficiency of studies on heavy and superheavy nuclei at the Super Heavy Element Factory of the Flerov Laboratory of Nuclear Reactions (FLNR) at the Joint Institute for Nuclear Research. The use of beams with the intensity up to 6×10 13 s -1 (10 pμA) delivered by the DC280 cyclotron requires an effective setup providing high suppression of background reaction products. Additionally, the described gas-filled separator is optimized for synthesis and study of heavy isotopes produced in complete fusion reactions of massive nuclei. Basic characteristics of DGFRS-2, as well as the results of the first test experiments, are presented. In comparison to the DGFRS-1, the transmission efficiency was doubled, and the background was reduced by a factor 200.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test and extraction methods for the QC parameters of silicon strip sensors for ATLAS upgrade tracker

The Quality Control (QC) of pre-production strip sensors for the Inner Tracker (ITk) of the ATLAS Inner Detector upgrade has finished, and the collaboration has embarked on the QC test programme for production sensors. This programme will last more than 3 years and comprises the evaluation of approximately 22000 sensors. 8 Types of sensors, 2 barrel and 6 endcap, will be measured at many different collaborating institutes. The sustained throughput requirement of the combined QC processes is around 500 sensors per month in total. Measurement protocols have been established and acceptance criteria have been defined in accordance with the terms agreed with the supplier. For effective monitoring of test results, common data file formats have been agreed upon across the collaboration. To enable evaluation of test results produced by many different test setups at the various collaboration institutes, common algorithms have been developed to collate, evaluate, plot and upload measurement data. This allows for objective application of pass/fail criteria and compilation of corresponding yield data. These scripts have been used to process the data of more than 3000 sensors so far, and have been instrumental for identification of faulty sensors and monitoring of QC testing progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗