Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Radar - 449MHz - Astoria, OR (AST) - Reviewed Data

**Winds.** A radar wind profiler measures the Doppler shift of electromagnetic energy scattered back from atmospheric turbulence and hydrometeors along 3-5 vertical and off-vertical point beam directions. Back-scattered signal strength and radial-component velocities are remotely sensed along all beam directions and are combined to derive the horizontal wind field over the radar. These data typically are sampled and averaged hourly and usually have 6-m and/or 100-m vertical resolutions up to 4 km for the 915 MHz and 8 km for the 449 MHz systems. **Temperature.** To measure atmospheric temperature, a radio acoustic sounding system (RASS) is used in conjunction with the wind profile. These data typically are sampled and averaged for five minutes each hour and have a 60-m vertical resolution up to 1.5 km for the 915 MHz and 60 m up to 3.5 km for the 449 MHz. **Moments and Spectra.** The raw spectra and moments data are available for all dwells along each beam and are stored in daily files. For each day, there are files labeled "header" and "data." These files are generated by the radar data acquisition system (LAP-XM) and are encoded in a proprietary binary format. Values of spectral density at each Doppler velocity (FFT point), as well as the radial velocity, signal-to-noise ratio, and spectra width for the selected signal peak are included in these files. Attached zip files, *449mhz-spectra-data-extraction.zip* and *449mhz-moment-data-extraction.zip*, include executables to unpack the spectra, (GetSpectra32.exe) and moments (GetMomSp32.exe), respectively. Documentation on usage and output file formats also are included in the zip files.

17 WIND ENERGY↗

Workflow for Process Automation of Soil Gas Results from an Automated Soil Gas-Sampling System for Application in Carbon Storage Projects

Conference presentation at Geoconvention, Calgary, Alberta, Canada, May 12–14, 2025. The Energy & Environmental Research Center (EERC) developed an automated workflow for processing soil gas measurements collected from the automated soil gas-sampling systems deployed across the project site. Raw soil gas measurements are collected from each station every 4 hours and automatically uploaded to a cloud database. The workflow begins by writing code to download the data to a workstation automatically, then the data are published to an online dashboard that visualizes the measurements in time-series plots and a process-based decision-making framework. This automated workflow accelerates the time from data acquisition to decision-making. It supports carbon storage project operators by preparing and delivering a live, standardized dataset for quick analysis and source attribution to provide assurance of containment and overall permit compliance.

02 PETROLEUM↗

Radar - 449MHz - North Bend, OR (OTH) - Raw Data

**Winds.** A radar wind profiler measures the Doppler shift of electromagnetic energy scattered back from atmospheric turbulence and hydrometeors along 3-5 vertical and off-vertical point beam directions. Back-scattered signal strength and radial-component velocities are remotely sensed along all beam directions and are combined to derive the horizontal wind field over the radar. These data typically are sampled and averaged hourly and usually have 6-m and/or 100-m vertical resolutions up to 4 km for the 915 MHz and 8 km for the 449 MHz systems. **Temperature.** To measure atmospheric temperature, a radio acoustic sounding system (RASS) is used in conjunction with the wind profile. These data typically are sampled and averaged for five minutes each hour and have a 60-m vertical resolution up to 1.5 km for the 915 MHz and 60 m up to 3.5 km for the 449 MHz. **Moments and Spectra.** The raw spectra and moments data are available for all dwells along each beam and are stored in daily files. For each day, there are files labeled "header" and "data." These files are generated by the radar data acquisition system (LAP-XM) and are encoded in a proprietary binary format. Values of spectral density at each Doppler velocity (FFT point), as well as the radial velocity, signal-to-noise ratio, and spectra width for the selected signal peak are included in these files. Attached zip files, *449mhz-spectra-data-extraction.zip* and *449mhz-moment-data-extraction.zip*, include executables to unpack the spectra, (GetSpectra32.exe) and moments (GetMomSp32.exe), respectively. Documentation on usage and output file formats also are included in the zip files.

17 WIND ENERGY↗

Radar - 449MHz - Astoria, OR (AST) - Raw Data

**Winds.** A radar wind profiler measures the Doppler shift of electromagnetic energy scattered back from atmospheric turbulence and hydrometeors along 3-5 vertical and off-vertical point beam directions. Back-scattered signal strength and radial-component velocities are remotely sensed along all beam directions and are combined to derive the horizontal wind field over the radar. These data typically are sampled and averaged hourly and usually have 6-m and/or 100-m vertical resolutions up to 4 km for the 915 MHz and 8 km for the 449 MHz systems. **Temperature.** To measure atmospheric temperature, a radio acoustic sounding system (RASS) is used in conjunction with the wind profile. These data typically are sampled and averaged for five minutes each hour and have a 60-m vertical resolution up to 1.5 km for the 915 MHz and 60 m up to 3.5 km for the 449 MHz. **Moments and Spectra.** The raw spectra and moments data are available for all dwells along each beam and are stored in daily files. For each day, there are files labeled "header" and "data." These files are generated by the radar data acquisition system (LAP-XM) and are encoded in a proprietary binary format. Values of spectral density at each Doppler velocity (FFT point), as well as the radial velocity, signal-to-noise ratio, and spectra width for the selected signal peak are included in these files. Attached zip files, *449mhz-spectra-data-extraction.zip* and *449mhz-moment-data-extraction.zip*, include executables to unpack the spectra, (GetSpectra32.exe) and moments (GetMomSp32.exe), respectively. Documentation on usage and output file formats also are included in the zip files.

17 WIND ENERGY↗

Radar - 449MHz - Forks, WA (FKS) - Raw Data

**Winds.** A radar wind profiler measures the Doppler shift of electromagnetic energy scattered back from atmospheric turbulence and hydrometeors along 3-5 vertical and off-vertical point beam directions. Back-scattered signal strength and radial-component velocities are remotely sensed along all beam directions and are combined to derive the horizontal wind field over the radar. These data typically are sampled and averaged hourly and usually have 6-m and/or 100-m vertical resolutions up to 4 km for the 915 MHz and 8 km for the 449 MHz systems. **Temperature.** To measure atmospheric temperature, a radio acoustic sounding system (RASS) is used in conjunction with the wind profile. These data typically are sampled and averaged for five minutes each hour and have a 60-m vertical resolution up to 1.5 km for the 915 MHz and 60 m up to 3.5 km for the 449 MHz. **Moments and Spectra.** The raw spectra and moments data are available for all dwells along each beam and are stored in daily files. For each day, there are files labeled "header" and "data." These files are generated by the radar data acquisition system (LAP-XM) and are encoded in a proprietary binary format. Values of spectral density at each Doppler velocity (FFT point), as well as the radial velocity, signal-to-noise ratio, and spectra width for the selected signal peak are included in these files. Attached zip files, *449mhz-spectra-data-extraction.zip* and *449mhz-moment-data-extraction.zip*, include executables to unpack the spectra, (GetSpectra32.exe) and moments (GetMomSp32.exe), respectively. Documentation on usage and output file formats also are included in the zip files.

17 WIND ENERGY↗

Workflow for Process Automation of Soil Gas Results from an Automated Soil Gas-Sampling System for Application in Carbon Storage Projects

Extended abstract for Geoconvention, Calgary, Alberta, Canada, May 12–14, 2025. The Energy & Environmental Research Center (EERC) developed an automated workflow for processing soil gas measurements collected from the automated soil gas-sampling systems deployed across the project site. Raw soil gas measurements are collected from each station every 4 hours and automatically uploaded to a cloud database. The workflow begins by writing code to download the data to a workstation automatically, then the data are published to an online dashboard that visualizes the measurements in time-series plots and a process-based decision-making framework. This automated workflow accelerates the time from data acquisition to decision-making. It supports carbon storage project operators by preparing and delivering a live, standardized dataset for quick analysis and source attribution to provide assurance of containment and overall permit compliance.

02 PETROLEUM↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Reconstruction from Uniformly Attenuated SPECT Projection Data Using the DBH Method

An algorithm was developed for the two-dimensional (2D) reconstruction of truncated and non-truncated uniformly attenuated data acquired from single photon emission computed tomography (SPECT). The algorithm is able to reconstruct data from half-scan (180o) and short-scan (180?+fan angle) acquisitions for parallel- and fan-beam geometries, respectively, as well as data from full-scan (360o) acquisitions. The algorithm is a derivative, backprojection, and Hilbert transform (DBH) method, which involves the backprojection of differentiated projection data followed by an inversion of the finite weighted Hilbert transform. The kernel of the inverse weighted Hilbert transform is solved numerically using matrix inversion. Numerical simulations confirm that the DBH method provides accurate reconstructions from half-scan and short-scan data, even when there is truncation. However, as the attenuation increases, finer data sampling is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic Force Microscope Controlled Topographical Imaging and Proximal Probe Thermal Desorption/Ionization Mass Spectrometry Imaging

This paper reports on the development of a hybrid atmospheric pressure atomic force microscopy/mass spectrometry imaging system utilizing nano-thermal analysis probes for thermal desorption surface sampling with subsequent atmospheric pressure chemical ionization and mass analysis. The basic instrumental setup and the general operation of the system were discussed and optimized performance metrics were presented. The ability to correlate topographic images of a surface with atomic force microscopy and a mass spectral chemical image of the same surface, utilizing the same probe without moving the sample from the system, was demonstrated. Co-registered mass spectral chemical images and atomic force microscopy topographical images were obtained from inked patterns on paper as well as from a living bacterial colony on an agar gel. Spatial resolution of the topography images based on pixel size (0.2 m x 0.8 m) was better than the resolution of the mass spectral images (2.5 m x 2.0 m), which were limited by current mass spectral data acquisition rate and system detection levels.

Ovchinnikova, Olga S↗

Emergence of the spin polarized domains in the kagome lattice Heisenberg antiferromagnet Zn-barlowite (Zn 0.95 Cu 0.05 )Cu 3 (OD) 6 FBr

Kagome lattice Heisenberg antiferromagnets are known to be highly sensitive to perturbations caused by the structural disorder. NMR is a local probe ideally suited for investigating such disorder-induced effects, but in practice, large distributions in the conventional one-dimensional NMR data make it difficult to distinguish the intrinsic behavior expected for pristine kagome quantum spin liquids from disorder-induced effects. Here we report the development of a two-dimensional NMR data acquisition scheme applied to Zn-barlowite (Zn 0.95 Cu 0.05 )Cu 3 (OD) 6 FBr kagome lattice, and successfully correlate the distribution of the low energy spin excitations with that of the local spin susceptibility. We present evidence for the gradual growth of domains with a local spin polarization induced by 5% Cu 2+ defect spins occupying the interlayer non-magnetic Zn 2+ sites. These spin-polarized domains account for ~60% of the sample volume at 2 K, where gapless excitations induced by interlayer defects dominate the low-energy sector of spin excitations within the kagome planes.

36 MATERIALS SCIENCE↗

High-speed two-dimensional terahertz spectroscopy with echelon-based shot-to-shot balanced detection

By using a reflective-echelon-based electro-optic sampling technique and a fast detector, we develop a two-dimensional terahertz (THz) spectrometer capable of shot-to-shot balanced readout of THz waveforms at a full 1-kHz repetition rate. To demonstrate the capabilities of this new detection scheme for high-throughput applications, we use gas-phase acetonitrile as a model system to acquire two-dimensional THz rotational spectra. The results show a two-order-of-magnitude speedup in the acquisition of multidimensional THz spectra when compared to conventional delay-scan methods while maintaining accurate retrieval of the nonlinear THz signal. Our report presents a feasible solution for bringing the technique of multidimensional THz spectroscopy into widespread practice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Mic-hackathon 2024: hackathon on machine learning for electron and scanning probe microscopy

Microscopy is one of the primary sources of information on materials structure and functionality at the nanometer and atomic scales. The data generated through microscopy is often contained in well-structured datasets, enriched with extensive metadata and sample histories, although not always with the same level of detail or storage format. The broad incorporation of data management plans by major funding agencies ensures the preservation and accessibility of this data. However, deriving insights from these rich datasets remains challenging due to the lack of established code ecosystems, standardized benchmarks, and integration strategies. Correspondingly, the efficiency of data usage is very low, and time expenditures at the analysis stage are enormous. In addition to post-acquisition data analysis, the emergence of application programming interfaces by major microscope manufacturers now creates opportunities for real-time ML-based data analytics to enable automated decision making, and particularly ML-agent controlled real-time microscope operation. Despite these opportunities, there is a significant gap in integrating the ML community with the broader microscopy community, limiting the value that these methods bring to physics and materials discovery and materials optimization. Hackathons address these challenges by fostering collaboration between ML experts and microscopy professionals, encouraging the development of innovative solutions that leverage ML for microscopy and preparing the workforce of the future both for microscopy-intensive domains areas, instrument manufacturers, and ML scientists interested in real world applications for fundamental research, materials optimization, and manufacturing. The hackathon generated benchmark datasets and digital twins of microscopes that further contribute to the development of the field and establish data analysis ecosystems. All the codes can be found at GitHub(https://github.com/KalininGroup/Mic-hackathon-2024-codes-publication/tree/1.0.0.1) and Zenodo (https://zenodo.org/records/15579940).

97 MATHEMATICS AND COMPUTING↗

Methamphetamine and HIV-Tat alter murine cardiac DNA methylation and gene expression

This study addresses the individual and combined effects of HIV-1 and methamphetamine (N-methyl-1-phenylpropan-2-amine, METH) on cardiac dysfunction in a transgenic mouse model of HIV/AIDS. METH is abused epidemically and is frequently associated with acquisition of HIV-1 infection or AIDS. We employed microarrays to identify mRNA differences in cardiac left ventricle (LV) gene expression following METH administration (10 d, 3 mg/kg/d, subcutaneously) in C57Bl/6 wild-type littermates (WT) and Tat-expressing transgenic (TG) mice. Arrays identified 880 differentially expressed genes (expression fold change > 1.5, p < 0.05) following METH exposure, Tat expression, or both. Using pathway enrichment analysis, mRNAs encoding polypeptides for calcium signaling and contractility were altered in the LV samples. Correlative DNA methylation analysis revealed significant LV DNA methylation changes following METH exposure and Tat expression. By combining these data sets, 38 gene promoters (27 related to METH, 11 related to Tat) exhibited differences by both methods of analysis. Among those, only the promoter for CACNA1C that encodes L-type calcium channel Cav1.2 displayed DNA methylation changes concordant with its gene expression change. Quantitative PCR verified that Cav1.2 LV mRNA abundance doubled following METH. Correlative immunoblots specific for Cav1.2 revealed a 3.5-fold increase in protein abundance in METH LVs. Data implicate Cav1.2 in calcium dysregulation and hypercontractility in the murine LV exposed to METH. They suggest a pathogenetic role for METH exposure to promote LV dysfunction that outweighs Tat-induced effects. - Highlights: • HIV-1 Tat and methamphetamine (METH) alter cardiac gene expression and epigenetics. • METH impacts gene expression or epigenetics more significantly than Tat expression. • METH alters cardiac mitochondrial function and calcium signaling independent of Tat. • METH alters DNA methylation, expression, and protein abundance of CACNA1C (Cav1.2).

60 APPLIED LIFE SCIENCES↗

THE BLANCO COSMOLOGY SURVEY: DATA ACQUISITION, PROCESSING, CALIBRATION, QUALITY DIAGNOSTICS, AND DATA RELEASE

The Blanco Cosmology Survey (BCS) is a 60 night imaging survey of {approx}80 deg{sup 2} of the southern sky located in two fields: ({alpha}, {delta}) = (5 hr, -55 Degree-Sign ) and (23 hr, -55 Degree-Sign ). The survey was carried out between 2005 and 2008 in griz bands with the Mosaic2 imager on the Blanco 4 m telescope. The primary aim of the BCS survey is to provide the data required to optically confirm and measure photometric redshifts for Sunyaev-Zel'dovich effect selected galaxy clusters from the South Pole Telescope and the Atacama Cosmology Telescope. We process and calibrate the BCS data, carrying out point-spread function-corrected model-fitting photometry for all detected objects. The median 10{sigma} galaxy (point-source) depths over the survey in griz are approximately 23.3 (23.9), 23.4 (24.0), 23.0 (23.6), and 21.3 (22.1), respectively. The astrometric accuracy relative to the USNO-B survey is {approx}45 mas. We calibrate our absolute photometry using the stellar locus in grizJ bands, and thus our absolute photometric scale derives from the Two Micron All Sky Survey, which has {approx}2% accuracy. The scatter of stars about the stellar locus indicates a systematic floor in the relative stellar photometric scatter in griz that is {approx}1.9%, {approx}2.2%, {approx}2.7%, and {approx}2.7%, respectively. A simple cut in the AstrOmatic star-galaxy classifier spread{sub m}odel produces a star sample with good spatial uniformity. We use the resulting photometric catalogs to calibrate photometric redshifts for the survey and demonstrate scatter {delta}z/(1 + z) = 0.054 with an outlier fraction {eta} < 5% to z {approx} 1. We highlight some selected science results to date and provide a full description of the released data products.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-infrared spectral tomography integrated with digital breast tomosynthesis: Effects of tissue scattering on optical data acquisition design

Purpose: Design optimization and phantom validation of an integrated digital breast tomosynthesis (DBT) and near-infrared spectral tomography (NIRST) system targeting improvement in sensitivity and specificity of breast cancer detection is presented. Factors affecting instrumentation design include minimization of cost, complexity, and examination time while maintaining high fidelity NIRST measurements with sufficient information to recover accurate optical property maps. Methods: Reconstructed DBT slices from eight patients with abnormal mammograms provided anatomical information for the NIRST simulations. A limited frequency domain (FD) and extensive continuous wave (CW) NIRST system was modeled. The FD components provided tissue scattering estimations used in the reconstruction of the CW data. Scattering estimates were perturbed to study the effects on hemoglobin recovery. Breast mimicking agar phantoms with inclusions were imaged using the combined DBT/NIRST system for comparison with simulation results. Results: Patient simulations derived from DBT images show successful reconstruction of both normal and malignant lesions in the breast. They also demonstrate the importance of accurately quantifying tissue scattering. Specifically, 20% errors in optical scattering resulted in 22.6% or 35.1% error in quantification of total hemoglobin concentrations, depending on whether scattering was over- or underestimated, respectively. Limited frequency-domain optical signal sampling provided two regions scattering estimates (for fat and fibroglandular tissues) that led to hemoglobin concentrations that reduced the error in the tumor region by 31% relative to when a single estimate of optical scattering was used throughout the breast volume of interest. Acquiring frequency-domain data with six wavelengths instead of three did not significantly improve the hemoglobin concentration estimates. Simulation results were confirmed through experiments in two-region breast mimicking gelatin phantoms. Conclusions: Accurate characterization of scattering is necessary for quantification of hemoglobin. Based on this study, a system design is described to optimally combine breast tomosynthesis with NIRST.

60 APPLIED LIFE SCIENCES↗

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

BSSD 2019 Performance Metric Q4

The LANL SFA in Terrestrial Microbial Carbon Cycling aims to inform climate modeling and enable carbon management in terrestrial ecosystems by discovering widespread biological processes that control carbon storage and release in temperate biome soils. To achieve these goals, computational approaches are essential to analyze increasingly complex ‘omics’ data from microbial communities in environmental samples. The SFA continues to leverage advances in ‘omics' measurement technology and computation tools to decipher microbial community function in environmental samples. The computational approach is aligned with the recent shift in the SFA’s research approach. When the SFA began 10 years ago, computational approaches principally addressed “who is there” with extremely limited insight into function. Accessible ‘omics' data for complex soil communities were primarily amplicon DNA sequences of taxonomic or functional marker genes obtained by PCR, cloning, and Sanger sequencing. Computational tools for community analysis were nascent. Over the past decade, genome resources (DOE-Integrated Microbial Genomics database) and data acquisition increased 1000-fold, common computational pipelines for many analysis tasks have arisen, and the variety of ‘omics’ measurements has expanded to routinely include shotgun metagenomics, metatranscriptomics, and versions of metabolomics. The SFA is capitalizing on these advances while also developing new computational techniques to decipher how communities with different patterns of carbon cycling function from the species to ecosystem level.

54 ENVIRONMENTAL SCIENCES↗