Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Treatment of Problematic Reactive Metal Wastes Using GeoMelt ICV - WM2020 Conference Paper

Decommissioning of sodium-cooled reactors and fast reactor technologies has generated a number of reactive metal waste configurations that are problematic to treat and typically lack cost effective treatment methods and disposition options. As a result, Veolia Nuclear Solutions, under contract with Idaho National Laboratory (owned by the U.S. Department of Energy and managed and operated by Battelle Energy Alliance, LLC) demonstrated its GeoMelt® In-Container Vitrification (ICV)™ technology to safely convert sodium metal to a non-reactive vitrified oxide form. The demonstration project, supported by glass formulation and crucible testing, consisted of a series of ICV™ melts that processed elemental sodium into stable non-reactive glass. INL is currently implementing GeoMelt® technology as a means to safely and reliably convert radioactive reactive metal residues that contaminate sodium cooled reactor components into waste forms that comply with existing disposition pathways. Reactive metal wastes require treatment in order to remove the Resource Conservation and Recovery Act (RCRA) reactivity and ignitability characteristics to comply with land disposal restrictions. GeoMelt®, which is an alternative to other potential treatment approaches, provides a robust approach that chemically converts the reactive metals to an inert oxide while also immobilizing radionuclides in a vitrified waste form with durability equal to or better than vitrified nuclear fuel reprocessing wastes (very robust and inert waste forms). Most other treatment approaches generate hydrogen gas which is problematic. In 2016, Veolia Nuclear Solutions first demonstrated the effectiveness of the GeoMelt® ICV™ process in deactivating reactive sodium metal. Crucible, bench-scale, and engineering-scale demonstrations were conducted on several surrogate waste configurations with various ratios of sodium metal and glass-formers. Each ratio and configuration demonstrated complete deactivation of the surrogate sodium metal. Follow-on work in 2017 demonstrated the deactivation of reactive sodium by GeoMelt® ICV™ at a higher waste loading relative to previously demonstrated work performed in 2016; the higher waste loading optimized glass chemistry while enhancing the economical full-scale treatment of reactive metals. Additionally, follow-on demonstration testing in 2018 and 2019 focused on more complex shapes and other reactive-metals (mocked up Experimental Breeder Reactor II [EBR-II] subassembly, sodium filled heat exchanger, and a can containing sodium potassium alloy) which were all performed at engineering-scale. Since 2018, a 10-metric ton full-scale GeoMelt unit (GeoMelt® Richland) was designed, installed, and commissioned at Perma-Fix Northwest in Richland, Washington for the treatment of reactive metal wastes. As of September 2019, over 900 55-gallon drums containing a total of around 3,500 lb of sodium with low levels of radioactivity have been treated at GeoMelt ® Richland, with resulting glass monoliths disposed at the Nevada National Security Site (NNSS). A full-scale radiological demonstration melt on an actual EBR-II subassembly has also been performed using the full-scale melter in 2019. The GeoMelt® technology is a proven radioactive waste treatment technology capable of immobilizing radioactive wastes, including bulk rubble such as drums and other steel vessels usually without pretreatment. Utilizing the GeoMelt® technology to treat reactive metals eliminates pretreatment steps resulting from having to separate the reactive metal from steel containers or jackets as GeoMelt® can easily operate at temperatures sufficient to melt the steel and expose the reactive metal for treatment. Eliminating handling steps of reactive metals is a significant safety advantage since reactive metals are pyrophoric. The results generated as a part of the 2018-2019 demonstration program are presented in the paper.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automating Testing of DUNE Electronics via a Finite State Machine

The Deep Underground Neutrino Experiment (DUNE) is a flagship international collaboration designed to study neutrinos tiny, nearly massless particles that may hold answers to fundamental questions about the Universe. Fermilab s Robotic Test Stand (RTS) plays a critical role in ensuring the quality of approximately 50,000 Application-Specific Integrated Circuit (ASIC) chips that will be used in DUNE s massive liquid argon detectors. These electronics will be inside the cryostat; therefore, they will need to have a high yield of working chips and low noise. To improve the automation and reliability of the RTS, this project focused on designing and implementing a Python-based finite state machine (FSM) to manage chip handling workflows. The FSM was developed as a modular software framework to coordinate robotic arm movements, manage chip tray positions, and monitor system states during testing. Key features include robust error handling routines, a pause/resume system for safe mid-cycle interruptions, and a simulation mode for iterative testing without hardware dependencies. The system was designed to prepare for seamless integration with RTS hardware components such as the robotic arm and vision system. This integration will streamline collaboration and enable efficient deployment of updates across the six total institutions performing testing. The outcomes of this internship contribute to Fermilab s mission to advance high-energy physics and support the DOE s national goals by directly improving the testing of equipment to be used in DUNE. The project also provided valuable experience in software design and contributing to the success of DUNE.

Kang, Caleb [William Rainey Harper Coll.]↗

Automating Testing of DUNE Electronics via a Finite State Machine

The Deep Underground Neutrino Experiment (DUNE) is a flagship international collaboration designed to study neutrinos—tiny, nearly massless particles that may hold answers to fundamental questions about the Universe. Fermilab’s Robotic Test Stand (RTS) plays a critical role in ensuring the quality of approximately 50,000 Application-Specific Integrated Circuit (ASIC) chips that will be used in DUNE’s massive liquid argon detectors. These electronics will be inside the cryostat; therefore, they will need to have a high yield of working chips and low noise. To improve the automation and reliability of the RTS, this project focused on designing and implementing a Python-based finite state machine (FSM) to manage chip handling workflows. The FSM was developed as a modular software framework to coordinate robotic arm movements, manage chip tray positions, and monitor system states during testing. Key features include robust error handling routines, a pause/resume system for safe mid-cycle interruptions, and a simulation mode for iterative testing without hardware dependencies. The system was designed to prepare for seamless integration with RTS hardware components such as the robotic arm and vision system. This integration will streamline collaboration and enable efficient deployment of updates across the six institutions performing testing. The outcomes of this internship contribute to Fermilab’s mission to advance high-energy physics and support the DOE’s national goals by directly improving the testing of equipment to be used in DUNE. The project also provided valuable experience in software design and contributing to the success of DUNE.

Kang, Caleb [Fermilab]↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-simulation of transactive energy markets: A framework for market testing and evaluation

The proliferation of distributed energy resources (DER)—and the ability to intelligently control these assets—is re-defining the electrical distribution system. As the number of controllable devices rapidly expands, grid operators must determine how to incorporate these assets while delivering reliable, equitable, and affordable electricity. One possible approach is to establish distribution-level electricity markets and allow devices/aggregations of devices to participate in price establishment. While this approach purports some of the same benefits as the highly successful wholesale electricity markets (i.e., open competition, efficient price discovery, reduced communication overhead), this needs to be researched and quantified via an analysis platform that models distribution-level markets at the appropriate fidelity. Specifically, the simultaneous evaluation of market performance, DER performance, DER bidding approaches, and distribution feeder power quality requires modeling that spans multiple technical areas. Co-simulation has emerged as a powerful tool in addressing this type of problem, where outputs depend on a range of underlying areas of expertise and associated models. In this paper we describe a solution, as implemented in the HELICS co-simulation platform, where we include (1) high fidelity house models, (2) intelligent bidding agents, (3) a modular market integration/design, and (4) a distribution feeder model. We then present a case study where we test two different market designs: (1) a pseudo-wholesale double-blind auction, and (2) an asynchronous matching market. In this work, the markets are run under two DER penetration levels and economic results are compared to full retail net energy metering and avoided cost net metering scenarios that bookend current approaches to remuneration of DER participation. We show the potential for transactive markets to provide increased value for most customers relative to net metering (and all customers relative to avoided cost scenarios) while decreasing costs for the utility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating switch lifetime in soft-switched single-stage differential-mode SST

The reliability of semiconductor switches in single-stage differential-mode solid-state transformers (DM-SSTs) has not been systematically evaluated under soft-switching operation and realistic grid conditions. This paper presents a switch-level reliability analysis for soft-switched and hard-switched DM-SST configurations by integrating converter-specific power loss modeling with empirical lifetime prediction. Analytical derivation of device current profiles specific to the DM-SST is used to characterize electrothermal stress, which is then mapped to lifetime using degradation models obtained from power cycling tests (PCTs). Applied to realistic SST load profiles and grid voltage variations, this approach provides a probabilistic prediction of switch lifetime for the DM-SST. Lifetime estimates for both SiC MOSFETs and Si IGBTs are presented, offering insight into device degradation under converter operating conditions. The results quantify the reliability benefits of soft switching in single-stage SSTs, highlighting how switching dynamics influence long-term switch degradation.

14 SOLAR ENERGY↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid Coal-Ash Characterization using Geophysical Methods & Machine Learning

Coal combustion products (CCP) are challenging to delineate in heterogeneous field settings. Conventional methods (test pits, coring, and laboratory analyses) are labor-intensive, slow, invasive, and provide sparse spatial coverage. This study evaluates whether rapid non-invasive geophysical screening methods—induced polarization (IP), magnetic susceptibility, and nuclear magnetic resonance (NMR) —combined with surface colorimetry (RGB_24), can discriminate CCP-soil mixtures and provide reliable estimates of CCP content. Laboratory measurements were collected on five CCP-soil mixtures (series) and modeled using (i) a linear baseline, (ii) a calibrated non-linear (power-mean) model, and (iii) a machine-learning (ML) Random Forest approach, with validation via leave-one-series-out and site-specific tests. Across the five series, individual signals—particularly IP and magnetic susceptibility—were strongly predictive of ash content but were consistently outperformed by combined models. The pooled calibrated non-linear and ML models captured the observed non-linearity and achieved high accuracy and precision, improving on linear fits. Colorimetry showed the weakest direct relationship with ash content for the tested samples but improved performance when included in multi-signal models. At pre-selected 3.5% decision threshold, calibrated and ML approaches yielded near-perfect classification (Matthews correlation coefficient ˜ 1), suggesting strong practical operability for field screening. Additionally, field-analog tests highlighted the role of endmembers—accuracy declined without access to end-member measurements but was largely recovered by collecting a minimal labeled pair for local recalibration. With end members, accuracy remained high. Globally trained models performed well on three operational unknowns; however, series-specific refits provided the most accurate predictions. Overall, these results highlight the potential of combining rapid geophysics and minimal local calibration for improved coal-ash delineation.

Peshtani, Klaudio↗

Ruthenium-lead oxide for acidic oxygen evolution reaction in proton exchange membrane water electrolysis

Developing an active and stable anode catalyst for the proton exchange membrane water electrolyzer (PEM-WE) is a critical objective to enhance the economic viability of green hydrogen technology. However, the expensive iridium-based electrocatalyst remains the sole practical material with industrial-level stability for the acidic oxygen evolution reaction (OER) at the anode. Ruthenium-based catalysts have been proposed as more cost-effective alternatives with improved activity, though their stability requires enhancement. The current urgent goal is to reduce costs and noble metal loading of the OER catalyst while maintaining robust activity and stability. Here, in this study, we design a Ru-based OER catalyst incorporating Pb as a supporting element. This electrocatalyst exhibits an OER overpotential of 201 mV at 10 mA.cm -2 , simultaneously reducing Ru noble metal loading by similar to 40%. Normalization of the electrochemically active surface area unveils improved intrinsic activity compared to the pristine RuO 2 catalyst. During a practical stability test in a PEM-WE setup, our developed catalyst sustains stable performance over 300 h without notable degradation, underscoring its potential for future applications as a reliable anodic catalyst.

Electrocatalysis↗

Biaxial steel plated concrete constitutive models for composite structures: Implementation and validation

The Steel-plated Concrete (SC) technique is an alternative construction technique with faster onsite construction speed, reduced construction time, and increased structural performance. Aiming to predict the force transfer mechanism of SC elements, an innovative constitutive model package is proposed by implementing experimental-based biaxial steel plate concrete models into the nonlinear finite element (FE) model “Membrane Model of SC (MM-CS).” First, the formulation and implementation of the MM-SC is illustrated in detail, including the equilibrium and compatibility equations and the implementation of constitutive models. Next, various experimental data of SC members are selected and simulated using the proposed MM-SC model. In this research, two types of structures, SC panels and framed SC shear walls, and three types of loading conditions, including uniaxial compression, pure shear, and combined axial-flexural-shear tests, are analyzed respectively. Good agreements were obtained between the reported results and the FE simulation results in terms of yield capacity and ultimate capacity, proving the reliability of the implemented analytical constitutive material models and the biaxial membrane model formulations.

42 ENGINEERING↗

Development and performance of a 2.9 Tesla dipole magnet using high-temperature superconducting CORC® wires

Although the high-temperature superconducting (HTS) REBa 2 Cu 3 O x (REBCO, RE-rare earth elements) material has a strong potential to enable dipole magnetic fields above 20 T in future circular particle colliders, the magnet and conductor technology needs to be developed. As part of an ongoing development to address this need, here we report on our CORC® canted cosθ magnet called C2 with a target dipole field of 3 T in a 65 mm aperture. The magnet was wound with 70 m of 3.8 mm diameter CORC® wire on machined metal mandrels. The wire had 30 commercial REBCO tapes from SuperPower Inc. each 2 mm wide with a 30 µm thick substrate. The magnet generated a peak dipole field of 2.91 T at 6.290 kA, 4.2 K. The magnet could be consistently driven into the flux-flow regime with reproducible voltage rise at an engineering current density between 400-550 A mm -2 , allowing reliable quench detection and magnet protection. The C2 magnet represents another successful step towards the development of high-field accelerator magnet and CORC® conductor technologies. The test results highlighted two development needs: continue improving the performance and flexibility of CORC® wires and develop the capability to identify locations of first onset of flux-flow voltage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Asymptotic-state prediction for fast flavor transformation in neutron star mergers

Neutrino flavor instabilities appear to be omnipresent in dense astrophysical environments, thus presenting a challenge to large-scale simulations of core-collapse supernovae and neutron star mergers (NSMs). Subgrid models offer a path forward, but require an accurate determination of the local outcome of such conversion phenomena. Focusing on “fast” instabilities, related to the existence of a crossing between neutrino and antineutrino angular distributions, we consider a range of analytical mixing schemes, including a new, fully three-dimensional one, and also introduce a new machine learning (ML) model. We compare the accuracy of these models with the results of several thousands of local dynamical calculations of neutrino evolution from the conditions extracted from classical NSM simulations. Our ML model shows good overall performance, but struggles to generalize to conditions from a NSM simulation not used for training. The multidimensional analytic model performs and generalizes even better, while other analytic models (which assume axisymmetric neutrino distributions) do not have reliably high performances, as they notably fail as expected to account for effects resulting from strong anisotropies. As a result, the ML and analytic subgrid models extensively tested here are both promising, with different computational requirements and sources of systematic errors.

79 ASTRONOMY AND ASTROPHYSICS↗

Mitigating the noise of DESI mocks using analytic control variates

In order to address fundamental questions related to the expansion history of the Universe and its primordial nature with the next generation of galaxy experiments, we need to model reliably large-scale structure observables such as the correlation function and the power spectrum. Cosmological N-body simulations provide a reference through which we can test our models, but their output suffers from sample variance on large scales. Fortunately, this is the regime where accurate analytic approximations exist. To reduce the variance, which is key to making optimal use of these simulations, we can leverage the accuracy and precision of such analytic descriptions using Control Variates (CV). The power of control variates stems from utilizing inexpensive but highly correlated surrogates of the statistics one wishes to measure. The stronger the correlation between the surrogate and the statistic of interest, the larger the variance reduction delivered by the method. We apply two control variate formulations to mock catalogs generated in anticipation of upcoming data from the Dark Energy Spectroscopic Instrument (DESI) to test the robustness of its analysis pipeline. Our CV-reduced measurements offer a factor of 5-10 improvement in the measurement error compared with the raw measurements. We explore the relevant properties of the galaxy samples that dictate this reduction and comment on the improvements we find on some of the derived quantities relevant to Baryon Acoustic Oscillation (BAO) analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

High Efficiency OLED Light Engine

LED Specialists has accomplished the program objective in designing a high efficiency OLED light engine combining high-performance OLED panels in the 5W-8W range. We achieved our goal by using an Active-Clamp Flyback circuit topology using state-of-the-art electronics. Evaluation testing of our second-generation prototype PC board has demonstrated an efficiency rating of 93% and dimming capability between 100% and 5% of OLED brightness. A reliability analysis of the design shows it to have a predicted Mean Time Between Failures (MTBF) of approximately 1,000,000 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wall Upgrades for Energy Retrofits: A Techno-Economic Study

Homes built before 1992, when the U.S. Department of Energy’s (DOE) Building Energy Codes Program was established, represent approximately 68% of the residential building stock in the country. Up to 43% of these homes have little to no insulation in the walls and have very high air leakage rates of 10 or more air changes per hour at 50 pascals of pressure (ACH50). These issues can represent a substantial portion of unnecessary money spent on utility bills for homeowners, especially in the colder climates. There is a significant need for cost-effective, reliable retrofit methods for these homes that include air, moisture, and vapor controls which are considered best practices for high-performance new home construction. Well-tested and documented wall retrofit systems can help to achieve substantial energy savings and also improve durability, comfort, health, and resilience. In 2018, DOE’s Building Technologies Office awarded Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota funding to complete a 3-year project to compare a range of residential wall retrofit systems that prioritized affordability, durability and energy savings potential. In addition to these core criteria, the ease-of-construction and the wide-scale applicability of the solutions also were considered. In this project, the research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of SCALE Criticality and Sensitivity Calculations for Reflected HEU Cylinders [Slides]

The SCALE code package offers multiple nuclear data libraries supporting Monte Carlo transport, with sensitivity and uncertainty methods derived from MC transport solutions. Several libraries are multigroup, which introduce bias differing by system. Previous work has shown poor S/U results in several reflector materials: ICSBEP benchmark HMF-084 was selected to analyze biases and S/U method applicability to a variety of reflectors. Prior and ongoing work found inaccuracies in CSAS and TSUNAMI results, which were further investigated utilizing the HEU-MET-FAST-084 ICSBEP critical benchmark, chosen for its geometrical simplicity and variety of reflector materials. Perturbation of reflector thickness across various reflector materials allowed for an assortment of materials is to be tested swiftly for each sequence and method. Observation was an increasing bias of MG $k_{eff}$ relative to CE, in both direction and magnitude. IFP produced extremely reliable results. >85% of CLUTCH cases were found satisfactory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Temperature Anode Recycle Blower for Solid Oxide Fuel Cell, Phase II (Final Report)

Broad commercialization of solid oxide fuel cells (SOFCs) requires anode offgas recycle blowers (ARCB) that are specifically designed for handling the challenging operating conditions presented by the SOFC process gases. Otherwise, they can be susceptible to frequent maintenance, low reliability, and short life. This report presents details of a DOE-funded Phase II effort conducted by Mohawk Innovative Technology, Inc. (MiTi®) for the development and testing of an oil-free, low cost, high-temperature centrifugal ARCB based on compliant foil bearing (CFB) technology for support of a 100 kW solid oxide fuel cell power plant. This Phase II builds on the results of a successful Phase I development project that resulted in the demonstration of a low TRL-6 prototype, shown in Figure 1. This Phase II final report presents design improvements over the Phase I prototype, presents the assembled test ARCBs, and discusses the advantages of this novel technology, particularly its long life and maintenance-free operation, which are derived from the use of CFBs. Also included are preliminary techno-economic analysis considerations for cost-effective deployment of the technology. The specific objectives of this project, as stated in the statement of program objectives (SOPO) were 1) to follow the methodology of design for manufacturing (or manufacturability) and assembly for implementing improvements identified as part of the Phase I effort with the purpose of reducing cost, enabling mass production, and facilitating the commercialization of a revised ARCB design, and 2) to fabricate four complete ARCB units based on the revised design and demonstrating their performance in both a laboratory setting and in an actual SOFC power plant. Execution of this SOPO would be supported by a number of technical tasks resulting in the fabrication and testing of the prototypes. To this end, MiTi continued the teaming relationship started during Phase I of the program with subcontracting partner FuelCell Energy, Inc. (FCE), which integrated (under a parallel effort funded by DOE Award DE-FE0026199) a modular 200 kWe SOFC power plant. MiTi and FCE coordinated to ultimately incorporate one of MiTi’s ARCB prototypes into one of the 100 kWe SOFC Modular Power Blocks (MPB) that constitute the core of FCE’s SOFC power plant for in-situ long-duration testing. Additionally, MiTi would explore the scalability and extendibility of the technology to other applications, as well as conduct a basic techno-economic analysis.

03 NATURAL GAS↗