Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Calibration of the 11x11-Foot Transonic Wind Tunnel at NASA Ames Research Center

A static pipe calibration characterizing the streamwise static pressure distribution was conducted at the 11-By 11-Foot Transonic Wind Tunnel at NASA Ames Research Center. This data is used to determine the local Mach number within the test section and evaluate buoyancy corrections to axial force measurements. The 60 foot long, 6 inch diameter pipe contained 444 static pressure taps spanning the test section and nozzle regions of the tunnel. The forward end of the pipe extends into the settling chamber and is held by four cables mounting to the tunnel shell, and the aft end is fixed on the institutional model support system. A hydraulic cylinder at the aft end of the pipe provides tension on the system to reduce vibration and to keep the pipe as level as possible throughout the test section. The previous calibration was improved upon by using pressure scanners with greater accuracy, ensuring a uniform pressure tube length for each tap to control pneumatic lag, optically tracking any streamwise movement of the pipe, and more tightly controlling the tunnel condition set points. Typically this calibration is conducted with the pipe on tunnel centerline and 33 inches below centerline for sting-mounted models and semi-span (i.e. floor-mounted) models respectively, however schedule demands permitted only the centerline calibration. The semi-span calibration is planned to be completed in the summer of 2020. Immediately following the static pipe calibration, a shorter, 9 foot static pipe used as the calibration check standard was installed to obtain its first post-calibration pressure dataset. This short static pipe consists of 148 static pressure taps distributed along the pipe section and one total pressure tap at the end of an ogive nose. Performing the calibration test and its check standard back-to-back allows this dataset to establish a reliable baseline for future calibration check standard testing. Over time the use of a calibration check standard offers the ability to assess the stability of the calibration through statistical process control in an efficient and costeffective manner, thereby potentially increasing the time required between full tunnel calibrations.

White, Bethany↗

Nickel hydrogen low Earth orbit life testing

A program to demonstrate the long term reliability of NiH2 cells in low Earth orbits (LEO) and support use in mid-altitude orbits (MAO) was initiated. Both 3.5 and 4.5 inch diameter nickel hydrogen cells are included in the test plan. Cells from all U.S. vendors are to be tested. The tests will be performed at -5 and 10 C at 40 and 60% DOD for LEO orbit and 10 C and 80% DOD for MAO orbit simulations. The goals of the testing are 20,000 cycles at 60% DOD and 30,000 cycles at 40% DOD. Cells are presently undergoing acceptance and characterization testing at Naval Weapons Systems Center, Crane.

Badcock, C. C.↗

Using Reliability to Meet Z540.3's 2 percent Rule

NASA's Kennedy Space Center (KSC) undertook implementation of ANSI/NCSL Z540.3-2006 in October 2008. Early in the implementation, KSC identified that the largest cost driver of Z540.3 implementation is measurement uncertainty analyses for legacy calibration processes. NASA, like other organizations, has a significant inventory of measuring and test equipment (MTE) that have documented calibration procedures without documented measurement uncertainties. This paper provides background information to support the rationale for using high in-tolerance reliability as evidence of compliance to the 2% probability of false acceptance (PFA) quality metric of ANSI/NCSL Z540.3-2006 allowing use of qualifying legacy processes. NASA is adopting this as policy and is recommending NCSL International consider this as a method of compliance to Z540.3. Topics covered include compliance issues, using end-of-period reliability (EOPR) to estimate test point uncertainty, reliability data influences within the PFA model, the validity of EOPR data, and an appendix covering "observed" versus "true" EOPR.

Mimbs, Scott M.↗

Shape Distribution of Fragments from Microsatellite Impact Tests

Fragment shape is an important factor for conducting reliable orbital debris damage assessments for critical space assets, such as the International Space Station. To date, seven microsatellite impact tests have been completed as part of an ongoing collaboration between Kyushu University and the NASA Orbital Debris Program Office. The target satellites ranged in size from 15 cm 15 cm 15 cm to 20 cm 20 cm 20 cm. Each target satellite was equipped with fully functional electronics, including circuits, battery, and transmitter. Solar panels and multi-layer insulation (MLI) were added to the target satellites of the last two tests. The impact tests were carried out with projectiles of different sizes and impact speeds. All fragments down to about 2 mm in size were collected and analyzed based on their three orthogonal dimensions, x, y, and z, where x is the longest dimension, y is the longest dimension in the plane perpendicular to x, and z is the longest dimension perpendicular to both x and y. Each fragment was also photographed and classified by shape and material composition. This data set serves as the basis of our effort to develop a fragment shape distribution. Two distinct groups can be observed in the x/y versus y/z distribution of the fragments. Objects in the first group typically have large x/y values. Many of them are needle-like objects originating from the fragmentation of carbon fiber reinforced plastic materials used to construct the satellites. Objects in the second group tend to have small x/y values, and many of them are box-like or plate-like objects, depending on their y/z values. Each group forms the corresponding peak in the x/y distribution. However, only one peak can be observed in the y/z distribution. These distributions and how they vary with size, material type, and impact parameters will be described in detail within the paper.

Liou, J.C.↗

Configuration management issues and objectives for a real-time research flight test support facility

Presented are some of the critical issues and objectives pertaining to configuration management for the NASA Western Aeronautical Test Range (WATR) of Ames Research Center. The primary mission of the WATR is to provide a capability for the conduct of aeronautical research flight test through real-time processing and display, tracking, and communications systems. In providing this capability, the WATR must maintain and enforce a configuration management plan which is independent of, but complimentary to, various research flight test project configuration management systems. A primary WATR objective is the continued development of generic research flight test project support capability, wherein the reliability of WATR support provided to all project users is a constant priority. Therefore, the processing of configuration change requests for specific research flight test project requirements must be evaluated within a perspective that maintains this primary objective.

Yergensen, Stephen↗

TurboBrayton Cryocooler: A Flight Worthy and Promising Future

A new development in cryocooler technology, a reverse TurboBrayton cycle cryocooler, developed by Creare, Inc. of Hanover, NH, has now been flight tested. This cooler provides high reliability and long life. With no linear moving components common in current flight cryocoolers, the TurboBrayton cooler requires no active control systems to provide a vibration-free signature. The cooler provides first stage cooling for advanced cryogenic systems and serves as a direct replacement for stored cryogen systems with a longer lifetime. Following a successful flight on STS-95, a TurboBrayton cryocooler will be flown on Hubble Space Telescope (HST) in 2000 to provide renewed refrigeration capability for the Near Infrared Camera and Multi-Object Spectrometer (NICMOS). The TurboBrayton cycle cooler is a promising technology already being considered for additional flight programs such as Next Generation Space Telescope (NGST) and Constellation X. These future missions require an advanced generation of the cooler that is currently under development to provide cooling at 10K and less. This paper presents an overview of the current generation cooler with recent flight test results and details the current plans and development progress on the next generation TurboBrayton technology for future missions.

Gibbon, Judith A.↗

Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program

A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.

Fayette, Daniel F.↗

Thermal Cycle Reliability of PBGA/CCGA 717 I/Os

Status of thermal cycle test results for a nonfunctional daisy-chained peripheral ceramic column grid array (CCGA) and its plastic ball grid array (PBGA) version. both having 560 I/Os. were presented in last year's conference. Test results included environmental data for three different thermal cycle regimes (-55 C/125 C, -55 C/100 C, and -50 C /75 C). Update information on these - especially failure type for assemblies with high and low solder volumes-were presented. The thermal cycle test procedure followed those recommended IPC-9701 for tin-lead solder joint assemblies. Revision A of this specification covers guideline thermal cycle requirements for Pb-free solder joints. Some background information discussed during release of this specification with its current guideline recommendations were also presented. In a recent reliability investigation a fully populated CCGA with 717 I/Os was also considered for assembly reliability. evaluation. The functional package is a field-programmable gate array that has much higher processing power than its previous version. This new package is smaller in dimension, has no interposer, and has a thinner column wrapped with copper for reliability improvement. This paper will also present thermal cycle test results for this package assembly and its plastic version with 728 I/Os. both of which were exposed to three different cycle regimes. Two cycle profiles were those specified by IPC- 9701A for tin-lead, i.e. -55 to 100 C and -55 to 125 C and one was a cycle profile specified by Mil-Std-883, i.e.. -65 C/150 C which is generally used for ceramic hybrid packages. Per IPC-9701 A, test vehicles were built using daisy chain packages and were continuously monitored. The effects of many process and assembly variables-including corner staking commonly used for improving resistance to mechanical loading such as drop and vibration loads--were also considered as part of the test matrix. Optical photomicrographs were taken at various thermal cycle intervals to document damage progress and behavior. Representative samples of these along with cross-sectional photomicrographs at higher magnification taken by scanning electron microscopy (SEM) to determine crack propagation and failure analyses for packages are also presented.

staking↗

An Analysis of Rocket Propulsion Testing Costs

The primary mission at NASA Stennis Space Center (SSC) is rocket propulsion testing. Such testing is commonly characterized as one of two types: production testing for certification and acceptance of engine hardware, and developmental testing for prototype evaluation or research and development (R&D) purposes. For programmatic reasons there is a continuing need to assess and evaluate the test costs for the various types of test campaigns that involve liquid rocket propellant test articles. Presently, in fact, there is a critical need to provide guidance on what represents a best value for testing and provide some key economic insights for decision-makers within NASA and the test customers outside the Agency. Hence, selected rocket propulsion test databases and references have been evaluated and analyzed with the intent to discover correlations of technical information and test costs that could help produce more reliable and accurate cost projections in the future. The process of searching, collecting, and validating propulsion test cost information presented some unique obstacles which then led to a set of recommendations for improvement in order to facilitate future cost information gathering and analysis. In summary, this historical account and evaluation of rocket propulsion test cost information will enhance understanding of the various kinds of project cost information; identify certain trends of interest to the aerospace testing community.

Ramirez, Carmen↗

Modeling and Simulation Reliable Spacecraft On-Board Computing

The proposed project will investigate modeling and simulation-driven testing and fault tolerance schemes for Spacecraft On-Board Computing, thereby achieving reliable spacecraft telecommunication. A spacecraft communication system has inherent capabilities of providing multipoint and broadcast transmission, connectivity between any two distant nodes within a wide-area coverage, quick network configuration /reconfiguration, rapid allocation of space segment capacity, and distance-insensitive cost. To realize the capabilities above mentioned, both the size and cost of the ground-station terminals have to be reduced by using reliable, high-throughput, fast and cost-effective on-board computing system which has been known to be a critical contributor to the overall performance of space mission deployment. Controlled vulnerability of mission data (measured in sensitivity), improved performance (measured in throughput and delay) and fault tolerance (measured in reliability) are some of the most important features of these systems. The system should be thoroughly tested and diagnosed before employing a fault tolerance into the system. Testing and fault tolerance strategies should be driven by accurate performance models (i.e. throughput, delay, reliability and sensitivity) to find an optimal solution in terms of reliability and cost. The modeling and simulation tools will be integrated with a system architecture module, a testing module and a module for fault tolerance all of which interacting through a centered graphical user interface.

Park, Nohpill↗

Bayesian estimation of life parameters in the Weibull distribution.

Development of a Bayesian analysis of the scale and shape parameters in the Weibull distribution and the corresponding reliability function with respect to the usual life-testing procedures. For the scale parameter theta, Bayesian estimates of theta and reliability are obtained for the uniform, exponential, and inverted gamma prior probability densities. Bhattacharya's results (1967) for the one-parameter exponential life-testing distribution are reduced to a special case of these results. A fully Bayesian analysis of both the scale and shape parameters is developed by assuming independent prior distributions; since in the latter case, analytical tractability is not possible, Bayesian estimates are obtained through a conjunction of Monte Carlo simulation and numerical-integration techniques. In both cases, a computer simulation is carried out, and a comparison is made between the Bayesian and the corresponding minimum-variance unbiased, or maximum likelihood, estimates. As expected, the Bayesian estimates are superior.

Canavos, G. C.↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through a enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through an enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Evaluation of 10V Chip Polymer Tantalum Capacitors for Space Applications

Due to low ESR and safe failure mode, new technology chip polymer tantalum capacitors (CPTC) have gained popularity in the electronics design community, first in commercial applications, and now in hi-rel and space systems. The major drawbacks of these parts are high leakage currents, degradation under environmental stresses, and a relatively narrow temperature range of operating and storage conditions. Several studies have shown that a certain amount of moisture in polymer cathodes is necessary for a normal operation of the parts. This might limit applications of CPTCs in space systems and requires analysis of long-term exposure to deep vacuum conditions on their performance and reliability. High leakage currents and limited maximum operational temperature complicate accelerated testing that is necessary to assess long-term reliability and require new screening and qualification procedures for quality assurance. A better understanding of behavior of CPTCs as compared to traditional, MnO2, capacitors is necessary to develop adequate approaches for QA system for space applications. A specific of CPTCs is that different materials and processes might be used for low-voltage (10 V and less) and high-voltage (above 10 V) capacitors, so performance and degradation processes in these groups require separate analysis. In this work, that is a part of the NASA Electronic Parts and Packaging (NEPP) program, degradation of AC and DC characteristics under environmental stresses at different temperatures and voltages have been studied in nine lots of commercial and automotive grade capacitors rated to 10 V. Results of analysis of leakage currents, high temperature storage (HTS) up to 5000 hrs in vacuum and air at different temperatures, and Highly Accelerated Life Testing (HALT) in the range from 85 C to 145 C are presented. Temperature and voltage acceleration factors were calculated based on approximation of distributions of degradation rates with a general log-linear Weibull model. Mechanisms of degradation and failures, and requirements for screening and qualification testing are discussed.

Tantalum Capacitors↗

Levitating Furnance for Containerless Processing in Space

The purpose of this project is to design, construct and test a levitator which would function reliably in a radiant heated cold wall furnace in a reduced gravity environment. A prototype levitating/positioning device termed the Sonic Pump Levitator is designed, built and successfully tested in full gravity and in the reduced gravity of the parabolic flight regime of the KC-135. Positioning is achieved by timely and appropriate application of gas momentum from one or more of six sonic pumps. The sonic pumps, which are arranged orthogonally in opposed pairs about the levitation region, are activated by an electro-optical, computer controlled, feedback system. The Sonic Pump Levitator is a promising candidate for containerless processing in microgravity. Being a null point device, it imposes minimal perturbation on the levitated, or positioned, target. Functioning as it does by optical feedback controlled jets of air, it would be expected to be free from disturbance caused by high temperature. This expectation is now being examined experimentally.

Dunn, S. A.↗

Design for validation, based on formal methods

Validation of ultra-reliable systems decomposes into two subproblems: (1) quantification of probability of system failure due to physical failure; (2) establishing that Design Errors are not present. Methods of design, testing, and analysis of ultra-reliable software are discussed. It is concluded that a design-for-validation based on formal methods is needed for the digital flight control systems problem, and also that formal methods will play a major role in the development of future high reliability digital systems.

Butler, Ricky W.↗