Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “random testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Fractal analysis of heart rate dynamics as a predictor of mortality in patients with depressed left ventricular function after acute myocardial infarction. TRACE Investigators. TRAndolapril Cardiac Evaluation

A number of new methods have been recently developed to quantify complex heart rate (HR) dynamics based on nonlinear and fractal analysis, but their value in risk stratification has not been evaluated. This study was designed to determine whether selected new dynamic analysis methods of HR variability predict mortality in patients with depressed left ventricular (LV) function after acute myocardial infarction (AMI). Traditional time- and frequency-domain HR variability indexes along with short-term fractal-like correlation properties of RR intervals (exponent alpha) and power-law scaling (exponent beta) were studied in 159 patients with depressed LV function (ejection fraction <35%) after an AMI. By the end of 4-year follow-up, 72 patients (45%) had died and 87 (55%) were still alive. Short-term scaling exponent alpha (1.07 +/- 0.26 vs 0.90 +/- 0.26, p <0.001) and power-law slope beta (-1.35 +/- 0.23 vs -1.44 +/- 0.25, p <0.05) differed between survivors and those who died, but none of the traditional HR variability measures differed between these groups. Among all analyzed variables, reduced scaling exponent alpha (<0.85) was the best univariable predictor of mortality (relative risk 3.17, 95% confidence interval 1.96 to 5.15, p <0.0001), with positive and negative predictive accuracies of 65% and 86%, respectively. In the multivariable Cox proportional hazards analysis, mortality was independently predicted by the reduced exponent alpha (p <0.001) after adjustment for several clinical variables and LV function. A short-term fractal-like scaling exponent was the most powerful HR variability index in predicting mortality in patients with depressed LV function. Reduction in fractal correlation properties implies more random short-term HR dynamics in patients with increased risk of death after AMI.

Non-NASA Center↗

Fundamental Studies on Two-Phase Gas-Liquid Flows Through Packed Beds in Microgravity

In the typical operation of a packed-bed reactor, gas and liquid flow simultaneously through a fixed bed of solid particles. Depending on the application, the particles can be of various shapes and sizes and provide for intimate contact and high rates of transport between the phases needed to sustain chemical or biological reactions. The packing may also serve as either a catalyst or as a support for growing biological material. NASA has flown two of these packed-bed systems in a microgravity environment with limited or no success. The goal of this research is to develop models (with scale-up capability) needed for the design of the physicochemical equipment to carry out these unit operations in microgravity. New insight will also lead to improvements in normal gravity operations. Our initial experiment was flown using an existing KC-135 two-phase flow rig with a modified test section. The test section is a clear polycarbonate rectangular column with a depth of 2.54 cm, a width of 5.08 cm, and 60 cm long. The column was randomly packed with spherical glass beads by slowly dropping the beads into the bed. Even though care was taken in handling the column after it was filled with packing, the alternating high and low gravity cycles with each parabola created a slightly tighter packed bed than is typically reported for this type. By the usual method of comparing the weight difference of a completely dry column versus a column filled with water, the void fraction was found to be .345 for both sizes of beads used. Five flush mounted differential pressure transducers are spaced at even intervals with the first location 4 cm from the inlet port and the subsequent pressure transducers spaced at 13 cm intervals along the column. Differential pressure data was acquired at 1000 Hz to adequately observe pulse formation and characteristics. Visual images of the flow were recorded using a high-speed SVHS system at 500 frames per second. Over 250 different test conditions were evaluated along with a companion set of tests in normal gravity. The flow rates, fluid properties and packing properties were selected to provide a range of several orders-of-magnitude for the important dimensionless parameters. Additional information is included in the original extended abstract.

Balakotaiah, Vemuri↗

Morphological Differentiation of Colon Carcinoma Cell Lines in Rotating Wall Vessels

The objectives of this project were to determine whether (1) microgravity permits unique, three-dimensional cultures of neoplastic human colon tissues and (2) this culture interaction produces novel intestinal growth and differentiation factors. The initial phase of this project tested the efficacy of simulated microgravity for the cultivation and differentiation of human colon carcinoma in rotating wall vessels (RWV's) on microcarrier beads. The RWV's simulate microgravity by randomizing the gravity vector in an aqueous medium under a low shear stress environment in unit gravity. This simulation achieves approximately a one-fifth g environment that allows cells to 'float' and form three-dimensional relationships with less shear stress than in other stirred aqueous medium bioreactors. In the second phase of this project we assessed the ability of human colon carcinoma lines to adhere to various substrates because adhesion is the first event that must occur to create three-dimensional masses. Finally, we tested growth factor production in the last phase of this project.

Jessup, J. M.↗

Nearest-Neighbor Machine Learning Feature Selection for Interpretation of Microbial Molecular Signatures from Isotope Ratio Mass Spectrometry Data

Mass spectrometry (MS) promises to be a powerful tool for potential biosignature detection during astrobiological missions on ocean worlds in our solar system. Accurate and generalizable machine learning methods could enhance science return on investment by predicting seawater chemistry and classifying isotopic biosignatures, either as a signature consistent with microbial life (biotic) or as a novelty (unclassified/unique). However, machine learning models are likely to be complex and involve interactions between MS features, making biosignatures difficult to interpret. Feature selection methods provide biological and chemical context that help interpret the mechanisms of machine learning models, but these methods also need the ability to detect complex interactions. Previously, we developed a machine learning feature selection algorithm called nearest-neighbor projected distance regression (NPDR) that has the ability to identify important model features that involve complex interactions and automatically reduce correlation and the dimensionality in a high-dimensional variable space. The standard distance metrics used in NPDR – Manhattan and Euclidean – assume the multivariate data are isotropic, which is often violated in real data due to differences in the covariance between variables. Thus, we extend NPDR to include a random forest distance, and other anisotropic distance metrics, for computing nearest neighbors. We also augment the isotope-ratio MS data with time-series features from the raw MS signal to improve biotic classification. We test NPDR on our novel experimental ocean world seawater analog MS data. We measure isotope fractionations of volatile CO 2 that could be measured in exospheres or plumes. Samples include baseline abiotic conditions using a range of possible seawater chemistry consistent with Europa and Enceladus, and biotic samples that include microbes in these seawaters. We use penalized NPDR with random forest proximity to identify interpretable microbial molecular signatures. We compare features with random forest importance, and we train a classifier that discriminates between biotic and abiotic samples with high accuracy. These ML-trained ocean-world analog MS data could be used to assist in identifying biosignatures during future missions.

geochemistry↗

Local dynamic subgrid-scale models in channel flow

The dynamic subgrid-scale (SGS) model has given good results in the large-eddy simulation (LES) of homogeneous isotropic or shear flow, and in the LES of channel flow, using averaging in two or three homogeneous directions (the DA model). In order to simulate flows in general, complex geometries (with few or no homogeneous directions), the dynamic SGS model needs to be applied at a local level in a numerically stable way. Channel flow, which is inhomogeneous and wall-bounded flow in only one direction, provides a good initial test for local SGS models. Tests of the dynamic localization model were performed previously in channel flow using a pseudospectral code and good results were obtained. Numerical instability due to persistently negative eddy viscosity was avoided by either constraining the eddy viscosity to be positive or by limiting the time that eddy viscosities could remain negative by co-evolving the SGS kinetic energy (the DLk model). The DLk model, however, was too expensive to run in the pseudospectral code due to a large near-wall term in the auxiliary SGS kinetic energy (k) equation. One objective was then to implement the DLk model in a second-order central finite difference channel code, in which the auxiliary k equation could be integrated implicitly in time at great reduction in cost, and to assess its performance in comparison with the plane-averaged dynamic model or with no model at all, and with direct numerical simulation (DNS) and/or experimental data. Other local dynamic SGS models have been proposed recently, e.g., constrained dynamic models with random backscatter, and with eddy viscosity terms that are averaged in time over material path lines rather than in space. Another objective was to incorporate and test these models in channel flow.

Cabot, William H.↗

Reynolds Number Effects at High Angles of Attack

Lessons learned from comparisons between ground-based tests and flight measurements for the high-angle-of-attack programs on the F-18 High Alpha Research Vehicle (HARV), the X-29 forward-swept wing aircraft, and the X-31 enhanced fighter maneuverability aircraft are presented. On all three vehicles, Reynolds number effects were evident on the forebodies at high angles of attack. The correlation between flight and wind tunnel forebody pressure distributions for the F-18 HARV were improved by using twin longitudinal grit strips on the forebody of the wind-tunnel model. Pressure distributions obtained on the X-29 wind-tunnel model at flight Reynolds numbers showed excellent correlation with the flight data up to alpha = 50 deg. Above (alpha = 50 deg. the pressure distributions for both flight and wind tunnel became asymmetric and showed poorer agreement, possibly because of the different surface finish of the model and aircraft. The detrimental effect of a very sharp nose apex was demonstrated on the X-31 aircraft. Grit strips on the forebody of the X-31 reduced the randomness but increased the magnitude of the asymmetry. Nose strakes were required to reduce the forebody yawing moment asymmetries and the grit strips on the flight test noseboom improved the aircraft handling qualities.

Fisher, David F.↗

A study of the durability of beryllium rocket engines

An experimental test program was performed to demonstrate the durability of a beryllium INTEREGEN rocket engine when operating under conditions simulating the space shuttle reaction control system. A vibration simulator was exposed to the equivalent of 100 missions of X, Y, and Z axes random vibration to demonstrate the integrity of the recently developed injector-to-chamber braze joint. An off-limits engine was hot fired under extreme conditions of mixture ratio, chamber pressure, and orifice plugging. A durability engine was exposed to six environmental cycles interspersed with hot-fire tests without intermediate cleaning, service, or maintenance. Results from this program indicate the ability of the beryllium INTEREGEN engine concept to meet the operational requirements of the space shuttle reaction control system.

Paster, R. D.↗

A statistical model of carbon/carbon composite failure

A failure model which considers the stochastic nature of the damage accumulation process is essential to assess reliability and to accurately scale the results from standard test specimens to composite structures. A superior filamentary composite for high temperature applications is composed of carbon fibers in a carbon matrix. Carbon-carbon composites are the strongest known material at very high temperatures. Since there appears to be a significant randomness in C-C material strength which cannot be controlled or detected with current technology, a better model of the material failure based upon statistical principles should be used. Simple applications of the model based upon the limited data provide encouraging results that indicate that better design of test specimens would provide a substantially higher prediction for the design strength of C-C composites. An A-basis strength for the C-C tensile rings from a first stage D-5 billets was estimated. A statistical failure model was developed for these rings which indicates that this strength may be very conservative for larger C-C parts. The analysis may be improved by use of a heterogeneous/noncontinuum finite element approach on the minimechanical level.

Slattery, Kerry T.↗

Development of Buffet Forcing Functions for a Transonic Condition Exhibiting Bimodal Flow Behavior

A wind-tunnel test campaign was used to derive Buffet Forcing Functions (BFFs) of the Space Launch System Block 1B vehicle configuration by measuring and integrating unsteady surface pressures on a 3-percent scale rigid buffet model (RBM) tested at the NASA Langley Transonic Dynamics Tunnel. The model was tested at predetermined and repeatable pitch and side-slip angles and flow Mach numbers encompassing a full range of possible flight conditions. Although each data point was collected at a steady wind-tunnel condition, a transient, bimodal flow behavior was observed in some Mach 1.10 measurements. The pressure time series was alternating between two states, which differed either in mean or fluctuation amplitude values, or both. As a consequence of this behavior, segments of the resultant BFFs can differ based on the duration that each measurement spends in a particular state. In this paper, a methodology is proposed, which envelopes the range of BFFs magnitudes resulting from this random bimodal phenomenon in pressure time histories of certain sensors.

wind-tunnel testing↗

Supersonic Retropropulsion Test 1853 in NASA LaRC Unitary Plan Wind Tunnel Test Section 2

A supersonic retropropulsion experiment was conducted in the Langley Research Center Unitary Plan Wind Tunnel Test Section 2 at Mach numbers of 2.4, 3.5, and 4.6. Intended as a code validation effort, this study used pretest computations to size and refine the model such that tunnel blockage and internal flow separations were minimized. A 5-in diameter 70 degree sphere-cone forebody, which can accommodate up to four 4:1 area ratio nozzles, followed by a 9.55 inches long cylindrical aft body was selected for this test after computational maturation. The primary measurements for this experiment were high spatial-density surface pressures. In addition, high speed schlieren video and internal pressures and temperatures were acquired. The test included parametric variations in the number of nozzles utilized, thrust coefficients (roughly 0 to 4), and angles of attack (-8 to 20 degrees). The run matrix was developed to also allow quantification of various sources of experimental uncertainty, such as random errors due to run-to-run variations and systematic errors due to flowfield or model misalignments. To accommodate the uncertainty assessment, many runs and replicates were conducted with the model at various locations within the tunnel and with model roll angles of 0, 60, 120, and 180 degrees. This test report provides operational details of the experiment, contains a review of trends, and provides all schlieren and pressure results within appendices.

Berry, Scott A.↗

At least some errors are randomly generated (Freud was wrong)

An experiment was carried out to expose something about human error generating mechanisms. In the context of the experiment, an error was made when a subject pressed the wrong key on a computer keyboard or pressed no key at all in the time allotted. These might be considered, respectively, errors of substitution and errors of omission. Each of seven subjects saw a sequence of three digital numbers, made an easily learned binary judgement about each, and was to press the appropriate one of two keys. Each session consisted of 1,000 presentations of randomly permuted, fixed numbers broken into 10 blocks of 100. One of two keys should have been pressed within one second of the onset of each stimulus. These data were subjected to statistical analyses in order to probe the nature of the error generating mechanisms. Goodness of fit tests for a Poisson distribution for the number of errors per 50 trial interval and for an exponential distribution of the length of the intervals between errors were carried out. There is evidence for an endogenous mechanism that may best be described as a random error generator. Furthermore, an item analysis of the number of errors produced per stimulus suggests the existence of a second mechanism operating on task driven factors producing exogenous errors. Some errors, at least, are the result of constant probability generating mechanisms with error rate idiosyncratically determined for each subject.

Sellen, A. J.↗

Software development tools: A bibliography, appendix C.

A bibliography containing approximately 200 citations on tools which help software developers perform some development task (such as text manipulation, testing, etc.), and which would not necessarily be found as part of a computing facility is given. The bibliography comes from a relatively random sampling of the literature and is not complete. But it is indicative of the nature and range of tools currently being prepared or currently available.

Riddle, W. E.↗

Development of baseline random vibration environment criteria for Shuttle pallet payload subsystems

This paper presents a statistical evaluation of measured random vibration response data obtained from the Office of Space Science-1 (OSS-1) pallet payload. The data were measured during the acoustic test simulation (September 1980) and the ascent phase of the flight of STS-3, Orbiter 102 (launched from the Kennedy Space Center on March 22, 1982). Acoustic test efficiency factors are evaluated based on the Dynamic, Acoustic and Thermal Environments (DATE) instrumentation as the source of the measured vibration data. Test efficiency correction to test data is applied in the extrapolation of non-DATE acoustic test data to increase sample population size for improved statistical evaluation. For baseline criteria evaluation and development, data are grouped in accordance with the payload zone in which the component is mounted.

On, F. J.↗

Development of baseline random vibration criteria for STS pallet payloads

This paper presents a statistical evaluation of measured random vibration response data obtained from the Office of Space Science-1 (OSS-1) pallet payload. The data were measured during the acoustic test simulation (September 1980) and the ascent phase of the flight of STS-3, Orbiter 102 (launched from the Kennedy Space Center on March 22, 1982). Acoustic test efficiency factors are evaluated based on the Dynamic, Acoustic and Thermal Environments (DATE) instrumentation as the source of the measured vibration data. Test efficiency correction to test data is applied in the extrapolation of non-DATE acoustic test data to increase sample population size for improved statistical evaluation. For baseline criteria evaluation and development, data are grouped in accordance with the payload 'zone' in which the component is mounted.

On, F. J.↗

Processing of laser formed SiC powder

Superior SiC characteristics can be achieved through the use of ideal constituent powders and careful post-synthesis processing steps. High purity SiC powders of approx. 1000 A uniform diameter, nonagglomerated and spherical were produced. This required major revision of the particle formation and growth model from one based on classical nucleation and growth to one based on collision and coalescence of Si particles followed by their carburization. Dispersions based on pure organic solvents as well as steric stabilization were investigated. Although stable dispersions were formed by both, subsequent part fabrication emphasized the pure solvents since fewer problems with drying and residuals of the high purity particles were anticipated. Test parts were made by the colloidal pressing technique; both liquid filtration and consolidation (rearrangement) stages were modeled. Green densities corresponding to a random close packed structure (approx. 63%) were achieved; this highly perfect structure has a high, uniform coordination number (greater than 11) approaching the quality of an ordered structure without introducing domain boundary effects. After drying, parts were densified at temperatures ranging from 1800 to 2100 C. Optimum densification temperatures will probably be in the 1900 to 2000 C range based on these preliminary results which showed that 2050 C samples had experienced substantial grain growth. Although overfired, the 2050 C samples exhibited excellent mechanical properties. Biaxial tensile strengths up to 714 MPa and Vickers hardness values of 2430 kg/sq mm 2 were both more typical of hot pressed than sintered SiC. Both result from the absence of large defects and the confinement of residual porosity (less than 2.5%) to small diameter, uniformly distributed pores.

Haggerty, J. S.↗

Processing of laser formed SiC powder

Processing research was undertaken to demonstrate that superior SiC characteristics could be achieved through the use of ideal constituent powders and careful post-synthesis processing steps. Initial research developed the means to produce approximately 1000 A uniform diameter, nonagglomerated, spherical, high purity SiC powders. Accomplishing this goal required major revision of the particle formation and growth model from one based on classical nucleation and growth to one based on collision and coalescence of Si particles followed by their carburization. Dispersions based on pure organic solvents as well as steric stabilization were investigated. Test parts were made by the colloidal pressing technique; both liquid filtration and consolidation (rearrangement) stages were modeled. Green densities corresponding to a random close packed structure were achieved. After drying, parts were densified at temperatures ranging from 1800 to 2100 C. This research program accomplished all of its major objectives. Superior microstructures and properties were attained by using powders having ideal characteristics and special post-synthesis processing procedures.

Haggerty, J. S.↗

Effect of double density caging during Space Shuttle transport of laboratory rats

Male Sprague Dawley rats were housed in groups of four in polycarbonate cages at recommended density and thermal environmental conditions for 14 days prior to testing to ensure uniform acclimation to those conditions. Body weights averaged 286 +/- 7 g at the end of acclimation. Rat cages were assigned randomly to three treatments: (1) 4 rats/polycarbonate cage (877 sq cm, 20.3 cm high, 220 sq cm/rat), (2) 4 rats/mock AEM (MAEM) (620 sq cm, 155 sq cm/rat), and (3) 8 rats/MAEM (620 sq cm, 77.5 sq cm/rat). A comparison between the MAEM-DD and MAEM-SD treatments was done to determine if doubling rat density in AEM's stressed the rats. A comparison among MAEM treatments and the PC treatment was done to determine if any stress indications were due to the AEM. During this density challenge phase, all treatments were maintained at the same thermal environmental conditions (22.5 C and 50 percent RH) for 10 days. After the density challenge phase, half the rats from each group were sacrificed for body tissue and fluid analyses. The remaining half of the rats were housed at a density of 4 rats/cage in polycarbonate cages at normal thermal environmental conditions for an additional 10 days to determine if there were any differences in responses between treatments after a recovery period. The remaining rats were examined and sacrificed for body tissue and fluid analyses at the end of the recovery phase.

Riskowski, G. L.↗