Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Investigation of a Real-time Processing System for the NASA Multifrequency Microwave Radiometer

A study was conducted to investigate the data reduction and processing requirements for the multifrequency microwave radiometer system (MFMR). The objectives were to develop and evaluate algorithms and processing techniques which might provide for dedicated real time or near real time data processing and to develop a configuration design and processor recommendation to accomplish the data reduction. An analysis of the required data reduction and calibration equations was included along with the identification of sources of error which may be present in the (MFMR) data. The definition and evaluation of the significance of effects introduced by aircraft perturbation was given.

Source record↗

Study of a Vuilleumier cycle cryogenic refrigerator for detector cooling on the limb scanning infrared radiometer

A program to detect and monitor the presence of trace constituents in the earth's atmosphere by using the Limb Scanning Infrared Radiometer (LSIR) is reported. The LSIR, which makes radiometric measurements of the earth's limb radiance profile from a space platform, contains a detector assembly that must be cooled to a temperature of 65 + or - 2 K. The feasibility of cooling the NASA-type detector package with Vuilleumier (VM) cryogenic refrigerator was investigated to develop a preliminary conceptual design of a VM refrigerator that is compatible with a flight-type LSIR instrument. The scope of the LSIR program consists of analytical and design work to establish the size, weight, power consumption, interface requirements, and other important characteristics of a cryogenic cooler that would meet the requirements of the LSIR. The cryogenic cooling requirements under the conditions that NASA specified were defined. Following this, a parametric performance analysis was performed to define the interrelationships between refrigeration characteristics and mission requirements. This effort led to the selection of an optimum refrigerator design for the LSIR mission.

Russo, S. C.↗

Scanning radiometer for measurement of forward-scattered light to determine mean diameter of spray particles

A scanning radiometer is reported that measures forward-scattered light to determine the mean diameter of spray particles. An optical scanning method gives a continuous measurement of the light-scattering angle during spray nozzle tests. A method of calibration and a correction for background light are presented. Mean particle diameters of 10 to 500 micrometers can be measured.

Buchele, D. R.↗

Scanning mechanism study for multi-frequency microwave radiometers

Scanning mode for a microwave radiometer having large aperture antenna is determined from scientific needs by engineering tradeoffs. Two configurations of the scan drive mechanism with an integral momentum compensation are formulated for 1.OM and 1.4M diameter antennas. As the formulation is based on currently available components, it is possible to design and fabricate the formulated mechanism without new hardware development. A preliminary specification for major components of formulated drives is also included in the report.

Shin, I.↗

A K-band radiometer for the microwave weather project

The design of a K-band radiometer for use in the microwave weather project is discussed. The major components of the system, such as feedhorn, waveguide switch, and receiver assembly are described. The system will be installed at DSS 13 at Goldstone, California, when completed.

Wallace, K.↗

A five-frequency radiometer antenna system feed horn

The feasibility of operating a five frequency feed as a radiometer for use on board a Nimbus type satellite was investigated. Five narrow band frequencies (6.6, 10.7, 18.5, 21.5 and 33 GHz) were multiplexed onto a single receive feed employing dual linear polarization at each frequency with a better than 25 db isolation between each polarization. The production of a horn design which can illuminate a parabolic reflector segment with an f/D ratio of approximately 0.4, producing an edge illumination of approximately -20 db is described. The final overall design is presented with results showing that this design concept has an acceptable electrical performance.

Source record↗

Advanced Atmospheric Sounder and Imaging Radiometer (AASIR)

Design information for the Advanced Atmospheric Sounder and Imaging Radiometer is reported, which was developed to determine the configuration of a sensor for IR and visible imaging. The areas of technology reported include: systems design, optics, mechanics, electronics, detectors, radiative cooler, and radiometric calibration.

Source record↗

Heat capacity mapping radiometer for AEM spacecraft

The operation, maintenance, and integration of the applications explorer mission heat capacity mapping radiometer is illustrated in block diagrams and detail schematics of circuit functions. Data format and logic timing diagrams are included along with radiometric and electronic calibration data. Mechanical and electrical configuration is presented to provide interface details for integration of the HCMR instrument to AEM spacecraft.

Sonnek, G. E.↗

Three field tests of a gas filter correlation radiometer

Test flights to remotely measure nonurban carbon monoxide (CO) concentrations by gas filter correlation radiometry are discussed. The inferred CO concentrations obtained through use of the Gas Filter Correlation Radiometer (GFCR) agreed with independent measurements obtained by gas chromatography air sample bottle analysis to within 20 percent. The equipment flown on board the aircraft, the flight test procedure, the gas chromatograph direct air sampling procedure, and the GFCR data analysis procedure are reported.

Campbell, S. A.↗

Insolation measurements with a portable CuS-CdS radiometer

Solar radiation measurements were carried out with a portable Cu2S-Cds radiometer. The measurements were found to be accurate to better than 5% (better than 3% when sophisticated metering is employed). Calibration to an Eppley precision pyranometer is discussed.

Windawi, H. M.↗

DSN water vapor radiometer development: Recent work

A water vapor radiometer (WVR) was developed which measures the atmospheric noise temperature at two different frequencies. These noise temperatures are used in empirical-theoretical equations which yield tropospheric range delay, in centimeters, through the atmosphere along the beam of the WVR. This range correction is then applied to measurements concerning spacecraft range and to very long baseline interferometry determinations.

Slobin, S. D.↗

Advanced atmospheric sounder and imaging radiometer /AASIR/ for STORMSAT

The principal mission of the three-axis stabilized STORMSAT spacecraft is to provide the necessary meteorological data for tracking, studying the detailed structure, and modeling mesoscale weather phenomena. In the area of mesoscale events, the following meteorological objectives are indicated: high-quality imagery, visible and infrared; wind velocity from cloud tracers (1 m/sec), atmospheric temperature profiles (1 K), and atmospheric humidity sounding. These objectives are reflected in the functional characteristics of the AASIR, which is a second generation meteorological sensor based on the Visible Infrared Spin-Scan Radiometer (VISSR) and the Atmospheric Sounder (VAS). The AASIR design and interface constraints with the STORMSAT spacecraft is discussed.

Chase, S. C.↗

A 230-GHz radiometer system employing a second-harmonic mixer

A radiometer system for use in the 1.3 mm region has been constructed and used for radio astronomical observations. A second-harmonic mixer employing a single Schottky diode downconverts the incident power to an IF frequency of about 1400 MHz. The measured double-sideband system noise temperature is 6000 K (noise figure = 13 dB) and the double-sideband mixer conversion loss is calculated to be 10 dB. The mixer is tunable over a range of at least 15 GHz.

Goldsmith, P. F.↗

A scanning multichannel microwave radiometer for Nimbus-G and SeaSat-A

A scanning multichannel microwave radiometer (SMMR) has been designed for the Nimbus-G spacecraft and incorporated also into the SeaSat-A payload for the primary purpose of determining sea surface temperatures and wind stress on a nearly all-weather basis. Observations of microwave polarization components will be made at wavelengths of 0.8, 1.4, 1.7, 2.8, and 4.6 cm over a swath 822 km wide below the Nimbus-G and 595 km wide below the SeaSat-A spacecraft. The smallest spatial resolution cell is about 20 km at a wavelength of 0.8 cm, and proportionately larger at the other wavelengths. Using algorithms based on a combination of experimental data and physical models for converting the observed brightness temperatures, the indicated accuracy of the results (excluding conditions of significant rainfall) are within 1 K for sea surface temperature and 2 m/s for surface wind speeds, over a range from 0-50 m/s.

Gloersen, P.↗

Estimating regional heat flux from scanning radiometer data

Method using matrix approach to determine best linear estimate of total flux consistent with condition of minimum variance proves useful in meteorological studies. It is useful for researchers studying options in scanner design such as scan pattern, scan rate, and radiometer field-of-view.

Bess, T. D.↗

Data processing for the DMSP microwave radiometer system

A software program was developed and tested to process microwave radiometry data to be acquired by the microwave sensor (SSM/T) on the Defense Meteorological Satellite Program spacecraft. The SSM/T 7-channel microwave radiometer and systems data will be data-linked to Air Force Global Weather Central (AFGWC) where they will be merged with ephemeris data prior to product processing for use in the AFGWC upper air data base (UADB). The overall system utilizes an integrated design to provide atmospheric temperature soundings for global applications. The fully automated processing at AFGWC was accomplished by four related computer processor programs to produce compatible UADB soundings, evaluate system performance, and update the a priori developed inversion matrices. Tests with simulated data produced results significantly better than climatology.

Rigone, J. L.↗

Advanced very high resolution radiometer

The advanced very high resolution radiometer development program is considered. The program covered the design, construction, and test of a breadboard model, engineering model, protoflight model, mechanical structural model, and a life test model. Special bench test and calibration equipment was also developed for use on the program.

Source record↗

Frequency selection and calibration of a water vapor radiometer

The calibration coefficients of existing water vapor radiometers are dependent upon meteorology profiles. This is shown to be due mainly to incorrect frequency pairs. By properly selecting an optimum frequency pair, the dependency can be reduced to a relatively small amount which can be handily adjusted by surface measurement alone. Hence, a universal calibration equation is applicable to all environmental conditions - site, seasonal and diurnal variations. Optimum frequency pairs are systematically searched. Error analysis indicates that calibration for the water vapor phase delay accurate to less than 2 cm is possible at all elevation angles greater than 15 degrees.

Wu, S. C.↗