Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radioactive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Design of SECAR a recoil mass separator for astrophysical capture reactions with radioactive beams

A recoil mass separator SECAR has been designed for the purpose of studying low-energy (p,γ) and (α,γ) reactions in inverse kinematics with radioactive beams for masses up to about A = 65. Their reaction rates are of importance for our understanding of the energy production and nucleosynthesis during explosive hydrogen and helium burning. The radiative capture reactions take place in a windowless hydrogen or He gas target at the entrance of the separator, which consists of four Sections . The first Section selects the charge state of the recoils. The second and third Sections contain Wien Filters providing high mass resolving power to separate efficiently the intense beam from the few reaction products. In the following fourth Section , the reaction products are guided into a detector system capable of position, angle and time-of-flight measurements. In order to accept the complete kinematic cone of recoil particles including multiple scattering in the target in the center of mass energy range of 0.2 MeV to 3.0 MeV, the system must have a large polar angle acceptance of ± 25 mrad. This requires a careful minimization of higher order aberrations. Furthermore, the present system will be installed at the NSCL ReA3 accelerator and will be used with the much higher beam intensities of the FRIB facility when it becomes available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and characterization of thin, self-supporting Si foils for use as targets in radioactive beam experiments

Development of thin, self-supporting silicon foils (both natural and isotopically-enriched) for use as targets in reaction studies with radioactive beams is detailed. Foils with a thickness of ~220 μg/cm 2 were produced using vapor deposition and were floated onto aluminum frames with 10–15 mm diameter holes. During their production, the foil thickness was measured using a quartz crystal monitor. Subsequently, the foil thickness was characterized by particle energy loss measurements and Rutherford backscattering (RBS). These measurements demonstrated that the thickness could be determined to within a 0.5% uncertainty. The elemental purity of the foils was assessed using RBS and X-ray photoelectron spectroscopy. Lastly, this analysis demonstrated that the foils have 87%–90% silicon abundance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel approach for critical heat flux enhancement during severe accident mitigation with removal of radioactive materials from the coolant

In this paper, a new system, which consists of mature and proven technologies, is suggested for simultaneous objectives in nuclear power plants: CHF enhancement and effective decontamination. It consists of multifunctional magnetic nanoparticles and a collector part. CHF enhancement for severe accident mitigation strategies like IVR-ERVC and core catcher is expected along with an efficient decontamination process of target radioactive nuclides, and through the collector part, where external magnetic fields are applied, working fluid can be effectively purified. The multifunctional magnetic nanoparticle possesses potentials to severe accident scenarios based on its distinct characteristics. Also, a nanofluid system is strongly affected by environments and state of the immersed particles; the CHF enhancement can be stably achieved in real applications with proper consideration and optimization.

Kam, Dong Hoon↗

Decay spectroscopy at the two-proton drip line: Radioactivity of the new nuclides 160 Os and 156 W

The radioactivity of $^{160}_{76}$Os 84 and $^{156}_{74}$W 82 that lie at the two-proton drip line has been measured in an experiment performed at the Accelerator Laboratory of the University of Jyväskylä. The 160 Os nuclei were produced using fusion-evaporation reactions induced by a beam of 310 MeV 58 Ni ions bombarding a 106 Cd target. The 160 Os ions were separated in flight using the recoil separator MARA and implanted into a double-sided silicon strip detector, which was used to measure their decays. The α decays of the ground state of 160 Os (Ε α = 7092(15) keV, t 1/2 = 97$^{+97}_{-32}$ μs) and its isomeric state (Ε α = 8890(10) keV, t 1/2 = 41$^{+15}_{-9}$ μs) were measured, allowing the excitation energy of the isomer to be determined as 1844(18) keV. These α-decay properties and the excitation energy of the isomer are compared with systematics. The α decays were correlated with subsequent decays to investigate the β decays of the ground state of 156 W, revealing that unlike its isotones, both low-lying isomers were populated in its daughter nuclide, 156 Ta. An improved value for the half-life of the proton-decaying high-spin isomeric state in $^{156}_{73}$Ta 83 of 333$^{+25}_{-22}$ ms was obtained in a separate experiment using the same experimental systems with a 102 Pd target. This result was employed to improve the precision of the half-life determined for 156 W, which was measured as 157$^{+57}_{-34}$ ms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In vivo transport of three radioactive [ 18 F]-fluorinated deoxysucrose analogs by the maize sucrose transporter ZmSUT1

Sucrose transporter (SUT) proteins translocate sucrose across cell membranes; however, mechanistic aspects of sucrose binding by SUTs are not well resolved. Specific hydroxyl groups in sucrose participate in hydrogen bonding with SUT proteins. We previously reported that substituting a radioactive fluorine-18 [ 18 F] at the C-60 position within the fructosyl moiety of sucrose did not affect sucrose transport by the maize (Zea mays) ZmSUT1 protein. To determine how 18 F substitution of hydroxyl groups at two other positions within sucrose, the C-10 in the fructosyl moiety or the C-6 in the glucosyl moiety, impact sucrose transport, we synthesized 10-[F 18 ]fluoro-10-deoxysucrose and 6-[F 18 ]fluoro-6-deoxysucrose ([ 18 F] FDS) analogs. In this work, each [ 18 F]FDS derivative was independently introduced into wild-type or sut1 mutant plants, which are defective in sucrose phloem loading. All three (10-, 60-, and 6-) [ 18 F]FDS derivatives were efficiently and equally translocated, similarly to carbon-14 [ 14 C]-labeled sucrose. Hence, individually replacing the hydroxyl groups at these positions within sucrose does not interfere with substrate recognition, binding, or membrane transport processes, and hydroxyl groups at these three positions are not essential for hydrogen bonding between sucrose and ZmSUT1. [ 18 F]FDS imaging afforded several advantages compared to [ 14 C]-sucrose detection. We calculated that 10-[ 18 F]FDS was transported at approximately a rate of 0.90 ± 0.15 m.h-1 in wild-type leaves, and at 0.68 ± 0.25 m.h-1 in sut1 mutant leaves. Collectively, our data indicated that [ 18 F]FDS analogs are valuable tools to probe sucrose-SUT interactions and to monitor sucrose transport in plants.

59 BASIC BIOLOGICAL SCIENCES↗

Monte Carlo investigation of a high-efficiency, two-plane Compton camera for long-range localization of radioactive materials

Compton cameras have become an instrument of interest for long-range localization of radioactive materials in nuclear-nonproliferation applications. In this work, a specialized simulation tool was developed for the optimization of a Compton camera through realistic Monte Carlo simulations. This tool can be used for Compton cameras with different geometries. The MCNPX-PoliMi code was used to simulate Compton scatters and photoelectric absorptions in the camera's detectors. The imaging capability is derived from the physics of Compton scattering and the full-energy information obtained in photoelectric absorptions. The simulated system is a 1 1 m2 Compton camera consisting of two planar arrays of photon detectors. Several scintillators were evaluated: LaBr3, CaF2, and NaI(Tl) (all inorganic scintillators), and C9H10 (plastic organic scintillator). The investigation was carried out with a 137Cs source. A minimum detectable activity (MDA) was defined and used to assess the performance of cameras based on different detectors. The simulation results show that C9H10 is a reliable, low-cost, scatter-plane material, increasing the MDA by ~0.2 mCi when compared to a CaF2 scatter plane. On the other hand, the intrinsic background of LaBr3 undermines its above-average energy resolution as the MDA increased by ~0.5 mCi when compared to a NaI(Tl) absorption plane.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Trisodium Phosphate Phases and Solubility in Alkaline Solutions Relevant to Radioactive Waste Processing

The U.S. Department of Energy’s Hanford Site faces significant challenges in managing millions of gallons of legacy radioactive waste, where phosphate precipitation can obstruct pipelines during retrieval and processing. To resolve long-standing inconsistencies in reported solubility and clarify factors governing trisodium phosphate hydrates, we examined the Na3PO4:NaOH:H2O system. Powder and single-crystal X-ray diffraction revealed that commercial precursors undergo transformations that produce multiple hydrates, including three previously unreported phases comprising an ordered polymorph of Na3(PO4)·12H2O·1/6NaOH, Na3PO4·5H2O, and Na3PO4·9H2O. Computational modeling indicated that the ordered dodecahydrate is more stable than its disordered counterpart, suggesting kinetic persistence of structural disorder. Solubility measurements were conducted with solutions prepared either from anhydrous Na3PO4 or from Na3(PO4)·12H2O·1/6NaOH and revealed that release of interstitial NaOH from the hydrate precursor elevated solution alkalinity, thereby significantly reducing phosphate solubility relative to solutions prepared with anhydrous Na3PO4 across 20–44 °C. These results begin to reconcile inconsistencies in prior solubility data and clarify how phase composition dictates phosphate precipitation under alkaline conditions.

Graham, Trenton R. (ORCID:0000000189078004)↗

Atom-at-a-Time Radioactive Molecule Identification: Looking toward Studies of Superheavy Elements

The chemical behavior of superheavy elements (SHEs, Z > 103) remains poorly understood. Their chemical properties are expected to deviate from established trends, challenging the predictive power of the periodic table. To investigate these elements experimentally, they must first be synthesized through nuclear reactions and then quickly subjected to chemical studies before they decay. Given the low production rates of these reactions and the need for measurements on an atom-at-a-time basis, innovative techniques are needed. Here, to address these challenges, a novel gas-phase chemistry method has been developed at Lawrence Berkeley National Laboratory, utilizing the Berkeley Gas-filled Separator and FIONA. This technique enables the production, identification, and study of molecular species formed by SHEs. As a proof of concept, we present measurements on the formation and identification of 151,152 HoO + molecules, demonstrating the capability to study the production of radioactive molecules under controlled conditions and directly identify them via their mass-to-charge ratio. These measurements validate the effectiveness of this technique for low-statistics SHE studies, highlighting the potential of this approach to ignite the next generation of experimental SHE chemistry research, offering a path to re-evaluate SHE placement on the periodic table.

Chemistry↗

Conjugates of Magnetic Nanoparticle -- Actinide Specific Chelator for Radioactive Waste Separation

A novel nanotechnology for the separation of radioactive waste that uses magnetic nanoparticles (MNPs) conjugated with actinide specific chelators (MNP-Che) is reviewed with a focus on design and process development. The MNP-Che separation process is an effective way of separating heat generating minor actinides (Np, Am, Cm) from spent nuclear fuel solution to reduce the radiological hazard. It utilizes coated MNPs to selectively adsorb the contaminants onto their surfaces, after which the loaded particles are collected using a magnetic field. The MNP-Che conjugates can be recycled by stripping contaminates into a separate, smaller volume of solution, and then become the final waste form for disposal after reusing number of times. Due to the highly selective chelators, this remediation method could be both simple and versatile while allowing the valuable actinides to be recovered and recycled. Key issues standing in the way of large-scale application are stability of the conjugates and their dispersion in solution to maintain their unique properties, especially large surface area, of MNPs. With substantial research progress made on MNPs and their surface functionalization, as well as development of environmentally benign chelators, this method could become very flexible and cost-effective for recycling used fuel. Finally, the development of this nanotechnology is summarized and its future direction is discussed.

99 GENERAL AND MISCELLANEOUS↗

Selective Binding and Light-Driven Release of Fluorous PF 6 – and Radioactive 99 TcO 4 – Anions for All-to-Nothing Liquid–Liquid Extraction

The removal of anions from aqueous media using molecular receptors in liquid–liquid extraction is a long-standing strategy to clean up contaminated water sources. Therein, high selectivity is needed to remove specific ions from mixtures of other ions, and high affinity provides extractions at low concentrations. However, the high affinity creates a conundrum by impeding the release of the ions in any stripping steps needed for further processing. To circumvent this problem, light-responsive receptors have been proposed as candidates for turning off the binding, but they are currently untested in liquid–liquid extraction. We tested the feasibility of light-driven release using a cyanostar macrocycle. We demonstrate the selective extraction of PF$^{–}_{6}$ anions over large excesses of competing anions (Cl – , NO$^{–}_{3}$, SO$^{2–}_{4}$) followed by photodriven release for quantitative isolation of the target. Release relies on photoisomerization of the macrocycle’s five stilbenes generating distorted isomers to turn off binding. With modest reversibility, only a single-shot release was demonstrated, akin to photodriven uncaging. These methods were extended to the capture and photodriven release of ReO$^{–}_{4}$ and radioactive 99 TcO$^{–}_{4}$ anions at ∼90% efficiency. Extraction was demonstrated down to the highly dilute 4 ppb levels of the 99 TcO$^{–}_{4}$ anion. Furthermore, this proof-of-concept demonstration verifies the use of a large change in affinity for the all-to-nothing capture and release of target anions between liquid phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanochemical synthesis of pillar[5]quinone derived multi-microporous organic polymers for radioactive organic iodide capture and storage

The incorporation of supramolecular macrocycles into porous organic polymers may endow the material with enhanced uptake of specific guests through host–guest interactions. Here we report a solvent and catalyst-free mechanochemical synthesis of pillar[5]quinone (P5Q) derived multi-microporous organic polymers with hydrophenazine linkages (MHP-P5Q), which show a unique 3-step N 2 adsorption isotherm. In comparison with analogous microporous hydrophenazine-linked organic polymers (MHPs) obtained using simple twofold benzoquinones, MHP-P5Q is demonstrated to have a superior performance in radioactive iodomethane (CH 3 I) capture and storage. Mechanistic studies show that the rigid pillar[5]arene cavity has additional binding sites though host–guest interactions as well as the halogen bond (-I···N = C-) and chemical adsorption in the multi-microporous MHP-P5Q mainly account for the rapid and high-capacity adsorption and long-term storage of CH 3 I.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational multiphysics modeling of radioactive aerosol deposition in diverse human respiratory tract geometries

The evaluation of aerosol exposure relies on generic mathematical models that assume uniform particle deposition profiles over the human respiratory tract and do not account for subject-specific characteristics. Here we introduce a hybrid-automated computational workflow that generates personalized particle deposition profiles in 3D reconstructed human airways from computed tomography scans using Computational Fluid and Particle Dynamics simulations. This is the first large-scale study to consider realistic airways variability, where 380 lower and 40 upper human respiratory tract 3D geometries are reconstructed and parameterized. The data is clustered into nine groups using random forest regression. Computational fluid and particle dynamics simulations are conducted on these representative geometries using a realistic heavy-breathing respiratory cycle and radioactive iodine-131 as a source term. Monte Carlo radiation transport simulations are performed to obtain detailed energy deposition maps. Our findings emphasize the importance of personalized studies, as minor respiratory tract variations notably influence deposition patterns rather than global parameters of the lower airways, observing more than 30% variance in the mass deposition fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion source developments for the production of radioactive isotope beams at TRIUMF

At the ISAC facility at TRIUMF radioactive ions are produced by bombarding solid targets with up to 100 μA of 500 MeV protons. The reaction products have to diffuse out of the hot target into an ion source. Normally, singly charged ions are extracted. They can be transported either directly to experiments or via an ECR charge state breeder to a post accelerator. Several different types of ion sources have to be used in order to deliver a large variety of rare isotope beams. At ISAC those are surface ion sources, forced electron beam arc discharge (FEBIAD) ion sources and resonant laser ionization sources. Recent development activities concentrated on increasing the selectivity for the ionization to suppress isobaric contamination in the beam. Therefore, a surface ion rejecting resonant laser ionization source (SIRLIS) has been developed to suppress ions from surface ionization. For the FEBIAD ion source a cold transfer line has been introduced to prevent less volatile components from reaching the ion source.

43 PARTICLE ACCELERATORS↗

Two-step laser ionization schemes for in-gas laser ionization and spectroscopy of radioactive isotopes

The in-gas laser ionization and spectroscopy technique has been developed at the Leuven isotope separator on-line facility for the production and in-source laser spectroscopy studies of short-lived radioactive isotopes. In this article, results from a study to identify efficient optical schemes for the two-step resonance laser ionization of 18 elements are presented.

07 ISOTOPE AND RADIATION SOURCES↗

A field programmable gate array-based time-resolved scaler for collinear laser spectroscopy with bunched radioactive potassium beams

A new data acquisition system including a Field Programmable Gate Array (FPGA) based time-resolved scaler was developed for laser-induced fluorescence and beam bunch coincidence measurements. The FPGA scaler was tested in a collinear laser-spectroscopy experiment on radioactive {sup 37}K at the BEam COoler and LAser spectroscopy (BECOLA) facility at the National Superconducting Cyclotron Laboratory at Michigan State University. A 1.29 μs bunch width from the buncher and a bunch repetition rate of 2.5 Hz led to a background suppression factor of 3.1 × 10{sup 5} in resonant photon detection measurements. The hyperfine structure of {sup 37}K and its isotope shift relative to the stable {sup 39}K were determined using 5 × 10{sup 4} s{sup −1} {sup 37}K ions injected into the BECOLA beam line. The obtained hyperfine coupling constants A({sup 2}S{sub 1/2}) = 120.3(1.4) MHz, A({sup 2}P{sub 1/2}) = 15.2(1.1) MHz, and A({sup 2}P{sub 3/2}) = 1.4(8) MHz, and the isotope shift δν{sup 39,} {sup 37} = −264(3) MHz are consistent with the previously determined values, where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Labview based data acquisition and multichannel analyzer software for radioactive particle tracking system

A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured with a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A singly charged ion source for radioactive {sup 11}C ion acceleration

A new singly charged ion source using electron impact ionization has been developed to realize an isotope separation on-line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive {sup 11}C ion beams. Low-energy electron beams are used in the electron impact ion source to produce singly charged ions. Ionization efficiency was calculated in order to decide the geometric parameters of the ion source and to determine the required electron emission current for obtaining high ionization efficiency. Based on these considerations, the singly charged ion source was designed and fabricated. In testing, the fabricated ion source was found to have favorable performance as a singly charged ion source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a time-resolved hard-x-ray detector using radioactive sources

A four-channel, time-resolved, hard x-ray detector (HXRD) has been operating at the Laboratory for Laser Energetics for more than a decade. The slope temperature of the hot-electron population in direct-drive inertial confinement fusion experiments is inferred by recording the hard x-ray radiation generated in the interaction of the electrons with the target. Measuring the energy deposited by hot electrons requires an absolute calibration of the hard x-ray detector. A novel method to obtain an absolute calibration of the HXRD using single photons from radioactive sources was developed, which uses a thermoelectrically cooled, low-noise, charge-sensitive amplifier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗