Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Narrow-band radiation wavelength measurement by processing digital photographs in RAW format

The technique of measuring the mean wavelength of narrow-band radiation in the 455 - 625-nm range using the image of the emitting surface is presented. The data from the camera array unprocessed by the built-in processor (RAW format) are used. The method is applied for determining the parameters of response of holographic sensors. Depending on the wavelength and brightness of the image fragment, the mean square deviation of the wavelength amounts to 0.3 - 3 nm. (experimental techniques)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase and amplitude retrieval of objects embedded in a sinusoidal background from its diffraction pattern

Efforts of phase and amplitude retrieval from diffraction patterns have almost exclusively been applied for nonperiodic objects. We investigated the quality of retrieval of nonperiodic objects embedded in a sinusoidal background, using the approach of iterative hybrid input-output with oversampling. Two strategies were employed; one by filtering in the frequency domain prior to phase retrieval, and the other by filtering the phase or amplitude image after retrieval. Results obtained indicate better outcomes with the latter approach provided detector noise is not excessive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-images deconvolution improves signal-to-noise ratio on gated stimulated emission depletion microscopy

Time-gated detection, namely, only collecting the fluorescence photons after a time-delay from the excitation events, reduces complexity, cost, and illumination intensity of a stimulated emission depletion (STED) microscope. In the gated continuous-wave- (CW-) STED implementation, the spatial resolution improves with increased time-delay, but the signal-to-noise ratio (SNR) reduces. Thus, in sub-optimal conditions, such as a low photon-budget regime, the SNR reduction can cancel-out the expected gain in resolution. Here, we propose a method which does not discard photons, but instead collects all the photons in different time-gates and recombines them through a multi-image deconvolution. Our results, obtained on simulated and experimental data, show that the SNR of the restored image improves relative to the gated image, thereby improving the effective resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of Properties of Images with Atomic Resolution in a Scanning Probe Microscope

A method for simulation of images in a scanning probe microscope (SPM) using simultaneous wavelet transform and median filtering is proposed. The wavelet transform with the fourth-order Daubechies kernel is used. Such a transform makes it possible to select details of different scales in the SPM image and, hence, study fractal properties of surfaces. Simulation is used to show that ultrahigh (atomic) resolution is possible in SPM provided that the size of the contact region in the probe–sample system is significantly greater than atomic size and the lattice atoms are randomly distributed. Contrast inversion in the SPM images in the multiscan mode is interpreted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thomas Jefferson National Accelerator Facility

The Thomas Jefferson National Accelerator Facility (Jefferson Lab) in Newport News, Virginia, USA, is one of ten national laboratories under the aegis of the Office of Science of the U.S. Department of Energy (DOE). It is managed and operated by Jefferson Science Associates, LLC. The primary facility at Jefferson Lab is the Continuous Electron Beam Accelerator Facility (CEBAF) as shown in an aerial photograph in Figure 1. Jefferson Lab was created in 1984 as CEBAF and started operations for physics in 1995. The accelerator uses superconducting radio-frequency (srf) techniques to generate high-quality beams of electrons with high-intensity, well-controlled polarization. The technology has enabled ancillary facilities to be created. The CEBAF facility is used by an international user community of more than 1200 physicists for a program of exploration and study of nuclear, hadronic matter, the strong interaction and quantum chromodynamics. Additionally, the exceptional quality of the beams facilitates studies of the fundamental symmetries of nature, which complement those of atomic physics on the one hand and of high-energy particle physics on the other. The facility is in the midst of a project to double the energy of the facility and to enhance and expand its experimental facilities. Studies are also pursued with a Free-Electron Laser produced by an energy-recovering linear accelerator.

43 PARTICLE ACCELERATORS↗

Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppression of image autocorrelation artefacts in spectral domain optical coherence tomography and multiwave digital holography

An improved method for suppressing image artefacts in spectral domain optical coherence tomography (SD OCT) and multiwave digital holography, caused by the influence of coherent noise in the course of successive registration of an autocorrelation component and informative signal is reported. The method allows complete suppression of all types of coherent noises, provided that the sample of values used to record the autocorrelation component satisfies the conditions of Kotelnikov's theorem: in SD OCT - for the transverse structure of the studied medium, in multiwave digital holography - for the envelop function of the radiation source frequency tuning spectrum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Poster — Thur Eve — 18: Cherenkov Emission By High-Energy Radiation Therapy Beams: A Characterization Study

We investigate Cherenkov emission (CE) by radiotherapy beams via radiation dose-versus-CE correlation analyses, CE detection optimization by means of a spectral shift towards the near-infrared (NIR) window of biological tissue, and comparison of CE to on-board MV imaging. Dose-CE correlation was investigated via simulation and experiment. A Monte Carlo (MC) CE simulator was designed using Geant4. Experimental phantoms include: water; tissue-simulating phantom composed of water, Intralipid®, and beef blood; plastic phantom with solid water insert. The detector system comprises an optical fiber and diffraction-grating spectrometer incorporating a front/back-illuminated CCD. The NIR shift was carried out with CdSe/ZnS quantum dots (QDs), emitting at (650±10) nm. CE and MV images were acquired with a CMOS camera and electronic portal imaging device. MC and experimental studies indicate a strong linear dose-CE correlation (Pearson coefficient > 0.99). CE by an 18-MeV beam was effectively NIR-shifted in water and a tissue-simulating phantom, exhibiting a significant increase at 650 nm for QD depths up to 10 mm. CE images exhibited relative contrast superior to MV images by a factor of 30. Our work supports the potential for application of CE in radiotherapy online imaging for patient setup and treatment verification, since CE is intrinsic to the beam and non-ionizing and QDs can be used to improve CE detectability, potentially yielding image quality superior to MV imaging for the case of low-density-variability, low-optical-attenuation materials (ex: breast/oropharynx). Ongoing work involves microenvironment functionalization of QDs and application of multi-channel spectrometry for simultaneous acquisition of dosimetric and tumor oxygenation signals.

07 ISOTOPE AND RADIATION SOURCES↗

Anti-phase boundaries at the SrTiO{sub 3}/Si(001) interface studied using aberration-corrected scanning transmission electron microscopy

In this work, the atomic structure of anti-phase boundary defects at the SrTiO{sub 3}/Si (001) interface is investigated by aberration-corrected scanning transmission electron microscopy. Atomic-resolution images reveal an abrupt SrTiO{sub 3}/Si interface with no intermediate oxide layer. Both single and double Si atomic columns (“dumbbells”) from different terraces of the Si(001) surface are visible at the interface. Anti-phase boundaries (APB) consisting of two adjacent TiO{sub 2} planes in the SrTiO{sub 3} (STO) film resulting either from Si surface steps or from the merging of crystalline domains from different surface nucleation sites are identified. These APBs occur on either {110} or {010} planes and both types have displacement vectors of a{sub STO}/2〈110〉.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signatures of electronic and nuclear coherences in ultrafast molecular x-ray and electron diffraction

Femtosecond x-ray and electron diffraction hold promise to image the evolving structures of single molecules. We present a unified quantum-electrodynamical formulation of diffraction signals, based on the exact many-body nuclear + electronic wavefunction that can be extracted from quantum chemistry simulations. This gives a framework for analyzing various approximate molecular dynamics simulations. We show that the complete description of ultrafast diffraction signals contains interesting contributions involving mixed elastic and inelastic scattered photons that are usually masked by other larger contributions and are neglected. These terms include overlaps of nuclear wavepackets between different electronic states that provide an electronic decoherence mechanism and are important for the time-resolved imaging of conical intersections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-CD-207B-06: Swank Factor of Segmented Scintillators in Multi-Slice CT Detectors: Pulse Height Spectra and Light Escape

Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of segmented ceramic GOS scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Epitaxial Cu{sub 2}ZnSnS{sub 4} thin film on Si (111) 4° substrate

To explore the possibility of Cu{sub 2}ZnSnS{sub 4} (CZTS)/Si based tandem solar cells, the heteroepitaxy of tetragonal Cu{sub 2}ZnSnS{sub 4} thin films on single crystalline cubic Si (111) wafers with 4° miscut is obtained by molecular beam epitaxy. The X-ray θ-2θ scan and selected area diffraction patterns of the CZTS thin films and Si substrates, and the high resolution transmission electron microscopy image of the CZTS/Si interface region demonstrate that the CZTS thin films are epitaxially grown on the Si substrates. A CZTS/Si P-N junction is formed and shows photovoltaic responses, indicating the promising application of epitaxial CZTS thin films on Si.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lasing in optimized two-dimensional iron-nail-shaped rod photonic crystals

We demonstrated lasing at the Γ-point band-edge (BE) modes in optimized two-dimensional iron-nail-shaped rod photonic crystals by optical pulse pumping at room temperature. As the radius of the rod increased quadratically toward the edge of the pattern, the quality factor of the Γ-point BE mode increased up to three times, and the modal volume decreased to 56% compared with the values of the original Γ-point BE mode because of the reduction of the optical loss in the horizontal direction. Single-mode lasing from an optimized iron-nail-shaped rod array with an InGaAsP multiple quantum well embedded in the nail heads was observed at a low threshold pump power of 160 μW. Real-image-based numerical simulations showed that the lasing actions originated from the optimized Γ-point BE mode and agreed well with the measurement results, including the lasing polarization, wavelength, and near-field image.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compounds for use in diagnosing and treating melanoma, including metastatic melanoma and methods related to same

The present invention is directed to novel non-invasive diagnostic tools/compounds comprising a cyclic peptide wherein the compound binds to a MSH receptor to image and treat cancers, especially, melanoma, including metastatic melanoma in vivo. The present invention represents a clear advance in the art which presently relies on tissue biopsy for diagnoses of these cancers. The novel imaging probes are capable of detecting cancerous melanoma cells, as well as their metastatic spread in tissues. This represents a quantum step forward in the diagnosis and treatment of melanoma, including metastatic melanoma using non-invasive molecular imaging techniques. The novel probes of the present invention will also be useful to initiate therapy for melanoma as well as monitor patients response to chemotherapy treatments and other interventions or therapies used in the treatment of melanoma/metastatic melanoma. Compounds according to the present invention may be used as diagnostic tools for a number of conditions and diseases states as well as therapeutic agents for treating such conditions and disease states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compounds for use in diagnosing and treating melanoma, including metastatic melanoma and methods related to same

The present invention is directed to novel non-invasive diagnostic tools/compounds comprising a cyclic peptide wherein the compound binds to a MSH receptor to image and treat cancers, especially, melanoma, including metastatic melanoma in vivo. The present invention represents a clear advance in the art which presently relies on tissue biopsy for diagnoses of these cancers. The novel imaging probes are capable of detecting cancerous melanoma cells, as well as their metastatic spread in tissues. This represents a quantum step forward in the diagnosis and treatment of melanoma, including metastatic melanoma using non-invasive molecular imaging techniques. The novel probes of the present invention will also be useful to initiate therapy for melanoma as well as monitor patients response to chemotherapy treatments and other interventions or therapies used in the treatment of melanoma/metastatic melanoma. Compounds according to the present invention may be used as diagnostic tools for a number of conditions and diseases states as well as therapeutic agents for treating such conditions and disease states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compositions for use in diagnosing and treating melanoma, including metastatic melanoma and methods related to same

The present invention is directed to novel non-invasive diagnostic tools/compounds comprising a cyclic peptide wherein the compound binds to a MSH receptor to image and treat cancers, especially, melanoma, including metastatic melanoma in vivo. The present invention represents a clear advance in the art which presently relies on tissue biopsy for diagnoses of these cancers. The novel imaging probes are capable of detecting cancerous melanoma cells, as well as their metastatic spread in tissues. This represents a quantum step forward in the diagnosis and treatment of melanoma, including metastatic melanoma using non-invasive molecular imaging techniques. The novel probes of the present invention will also be useful to initiate therapy for melanoma as well as monitor patients response to chemotherapy treatments and other interventions or therapies used in the treatment of melanoma/metastatic melanoma. Compounds according to the present invention may be used as diagnostic tools for a number of conditions and diseases states as well as therapeutic agents for treating such conditions and disease states.

Miao, Yubin↗

Non-radiative recombination at dislocations in InAs quantum dots grown on silicon

We study the impact of misfit dislocations on the luminescence from InAs quantum dots (QDs) grown on Si substrates. Electron channeling contrast imaging is used together with cathodoluminescence mapping to locate misfit dislocations and characterize the resulting nonradiative recombination of carriers via near-infrared light emission profiles. With a 5 kV electron beam probe, the dark line defect width due to a typical misfit dislocation in a shallow QD active layer is found to be approximately 1 μ m, with a 40%–50% peak emission intensity loss at room temperature. Importantly, we find that at cryogenic temperatures, the dislocations affect the QD ground state and the first excited state emission significantly less than the second excited state emission. At the same time, the dark line defect width, which partially relates to carrier diffusion in the system, is relatively constant across the temperature range of 10 K–300 K. Our results suggest that carrier dynamics in the QD wetting layer control emission intensity loss at dislocations, and that these defects reduce luminescence only at those temperatures where the probability of carriers thermalizing from the dots into the wetting layer becomes significant. We discuss the implications of these findings toward growing dislocation-tolerant, reliable quantum dot lasers on silicon.

Electron beams↗