Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Techno-Economic Analysis of Distributed Energy Generation in Crow Creek, Alaska

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NLR, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported Crow Creek in Girdwood, AK with a feasibility analysis for a microgrid to provide year-round power across the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Robust Segmented Mixed Effect Regression Model for Baseline Electricity Consumption Forecasting

Renewable energy production has been surging around the world in recent years. To mitigate the increasing uncertainty and intermittency of the renewable generation, proactive demand response algorithms and programs are proposed and developed to further improve the utilization of load flexibility and increase the efficiency of power system operation. One of the biggest challenges to efficient control and operation of demand response resources is how to forecast the baseline electricity consumption and estimate the load impact from demand response resources accurately. In this paper, we propose a mixed effect segmented regression model and a new robust estimate for forecasting the baseline electricity consumption in Southern California, USA, by combining the ideas of random effect regression model, segmented regression model, and the least trimmed squares estimate. Since the log-likelihood of the considered model is not differentiable at breakpoints, we propose a new backfitting algorithm to estimate the unknown parameters. The estimation performance of the new estimation procedure has been demonstrated with both simulation studies and the real data application for the electric load baseline forecasting in Southern California.

42 ENGINEERING↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Levelized Cost of Charging Electric Vehicles

This data set includes the levelized cost of charging (LCOC) and lifetime fuel cost savings (LFCS) values as reported in "Levelized Cost of Charging of Electric Vehicles in the United States." Values are reported at the state and national levels for battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs). The data set also includes the four annual direct current fast charging (DCFC) station load profiles used to approximate the levelized cost of DCFC charging. Each profile provides 15-min resolved power requirements for one full year. Borlaug, B., Salisbury, S., Gerdes, M., and Muratori, M., Levelized Cost of Charging Electric Vehicles in the United States, Joule (2020), https://doi.org/10.1016/j.joule.2020.05.013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heavy-Duty Electric Fleet Depot Charging Load Profiles & Substation Load Integration Assessment Results

This data set includes the 24-hour fleet depot charging load profiles (15-min. average demand) and substation load integration assessment results produced for the study, "Heavy-Duty Truck Electrification and the Impacts of Depot Charging on Electricity Distribution Systems", published in 2021 (https://doi.org/10.1038/s41560-021-00855-0). The code developed to generate these load profiles is publicly available at https://github.com/NREL/hdev-depot-charging-2021. Please cite as: Borlaug, B., Muratori, M., Gilleran, M., Woody, D., Muston, W., Canada, T., Ingram, A., Gresham, H., and McQueen, C., (2021). "Heavy-Duty Truck Electrification and the Impacts of Depot Charging on Electricity Distribution Systems". https://doi.org/10.1038/s41560-021-00855-0.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real time feedback-based optimization of distributed energy resources

An example device includes a processor configured to receive a plurality of voltage values corresponding to voltage nodes in a first portion of a power system and determine, for each voltage node, a respective value of first and second voltage-constraint coefficients. The processor is also configured to receive a power value corresponding to a connection point of the first portion of the power system with a second portion of the power system and determine for the connection point, a respective value of first and second power-constraint coefficients. The processor is also configured to cause at least one energy resource connected to the first portion of the power system to modify an output power of the at least one energy resource based on the value of the first and second voltage-constraint coefficients for each voltage node and the value of the first and second power-constraint coefficients.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector. Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation. The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

building-level electrical distribution↗

NRIC Final Water Management Options

The purpose of this paper is to inform advanced reactor developers of the conditions and requirements needed to manage the water used to reject heat from advanced reactor demonstrations at the INL. While there are many advanced reactor concepts, all of them require heat rejection, and some plan to use water for hear rejection. Cooling water for heat rejection is frequently the largest fresh-water load for a nuclear reactor, and therefore the focus of water management. The type of reactor and its purpose, the physical conditions at the INL, and the regulatory structure of the demonstration also influence the optimal method of heat rejection. Choosing the best method of rejecting heat will significantly influence the cost and probability of success for any advanced reactor demonstration. One of the important considerations in the deployment of demonstration plants at the INL site is water use and its implications. Advanced reactor developers need to consider the limitations of the water consumption based on the state and federal regulations. The water consumption may become a limitation when the demonstration reactor capacities reach to conventional nuclear power plants.

99 GENERAL AND MISCELLANEOUS↗

Short-term Electricity Price Forecasting with Constrained Regressors

The volatility of electricity price presents a challenge to market participants as their decision-making process are highly depend on the accuracy of price forecasts. However, there is growing empirical evidence of increasing price volatility and price spikes in electricity markets as a result of variable renewable energy generation, extreme weather events, and other factors. The distribution shift caused by spikes in electricity price data differentiates the forecasting tasks from other renewable energy sources. Moreover, the observations may be compromised by cyberattacks and thus not available in the testing phase. To this end, we propose a Similarity-Enhanced Electricity Decomposition Forecasting model (SEED-Forecaster) to address the missing response problem and spikes capturing in short-term electricity price forecasting. The effectiveness of the proposed framework is tested on real-world electricity price data from California Independent System Operator (CAISO). Numerical results of case studies show that the proposed SEED-Forecsater can enhance forecasting performance, particularly in capturing electricity spikes, even under conditions without regressors during testing stage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Leveraging Artificial Intelligence in Federal Projects

Artificial intelligence (AI) has the potential to transform grid operations. As energy demand rises, weather patterns shift, and foreign threats to critical infrastructure grow, it is essential to harness advanced technology to modernize the grid and increase overall resiliency. This paper examines the integration of AI in federally funded grid infrastructure projects. By analyzing project data, it evaluates the penetration and use cases of AI technologies within key funding initiatives and explores opportunities and challenges associated with their deployment. This analysis categorizes AI adoption in recent federal grid investments, establishing a baseline for measuring near-term impacts and identifying promising AI applications. The research found that 16% of recent federal energy projects included AI integration, and approximately 75% of these projects used AI for more than one primary application.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Quantum-Inspired Power System Reliability Assessment

To enable an in-depth study of power system operation and planning, the assessment of standard reliability indices is inevitable. The Monte Carlo Simulation (MCS) approach is a broadly used method in replacing the analytical methods in reliability indices assessment. The accuracy of MCS, however, highly depends on the sampling size, and hence, a complicated system with large number of components requires a large sampling size and daunting computational effort. To address this shortcoming, we, in this paper attempt to take advantage of potentials of the quantum computing (QC) for power system reliability assessment by realizing the following contributions: 1) an innovative quantum model designed for reliability assessment; 2) a quantum circuit that achieves the quadratic speed up compared to the classical MCS method; 3) an efficient quantum amplitude estimation (QAE) algorithm to accurately evaluate the reliability indices. The accuracy and efficacy of the quantum reliability method are extensively verified and demonstrated on both radial and mesh distribution systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OPTIMAL CONTROL AND ENERGY-SAVING ANALYSIS OF COMMON PRESSURE RAIL ARCHITECTURES: HHEA & STEAM

In recent years several novel hydraulic architectures have been proposed with the intention of significantly increasing system efficiency. Two of these architectures, Steigerung der Energieeffizienz in der Arbeitshydraulik mobiler Arbeitsmaschinen (STEAM), and the Hybrid Hydraulic-Electric Architecture (HHEA), use a system of multiple common pressure rails (CPRs) to serve the multiple degrees-of-freedom of the machine. The key difference is that STEAM throttles hydraulic power from these rails while HHEA combines electric and hydraulic power to meet actuator demands. As a throttle-less architecture, HHEA is expected to save more energy than STEAM at the expense of added complexity. Therefore, it is useful to quantify this additional energy saving. Both systems have discrete operational choices corresponding to how the CPRs are utilized for each actuator. It is necessary to determine optimal operation for each of these architectures for analysis and fair comparison. Techniques for optimal operation of the HHEA have been developed previously from the Langrange multiplier method. Applying the same optimal control method to STEAM encountered some technical challenge leading to the optimal control algorithm not being able to satisfy certain constraints. The issue is analyzed and solved by adding noise to the optimization. Using this proposed algorithm, case studies are performed to compare the energy-saving potentials of STEAM and HHEA for two sizes of excavators and a wheel-loader performing representative duty cycles. The baseline is a standard load-sensing architecture. Results show that STEAM and HHEA can reduce energy consumption between 35-65% and 50-80% respectively

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating an Ensemble Reward System into an Off-Policy Reinforcement Learning Algorithm for the Economic Dispatch of Small Modular Reactor-Based Energy Systems

Nuclear Integrated Energy Systems (NIES) have emerged as a comprehensive solution for navigating the changing energy landscape. They combine nuclear power plants with renewable energy sources, storage systems, and smart grid technologies to optimize energy production, distribution, and consumption across sectors, improving efficiency, reliability, and sustainability while addressing challenges associated with variability. The integration of Small Modular Reactors (SMRs) in NIES offers significant benefits over traditional nuclear facilities, although transferring involves overcoming legal and operational barriers, particularly in economic dispatch. This study proposes a novel off-policy Reinforcement Learning (RL) approach with an ensemble reward system to optimize economic dispatch for nuclear-powered generation companies equipped with an SMR, demonstrating superior accuracy and efficiency when compared to conventional methods and emphasizing RL’s potential to improve NIES profitability and sustainability. Finally, the research attempts to demonstrate the viability of implementing the proposed integrated RL approach in spot energy markets to maximize profits for nuclear-driven generation companies, establishing NIES’ profitability over competitors that rely on fossil fuel-based generation units to meet baseload requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High Performance Metal-Supported SOFC System for Range Extension of Commercial Aviation

The DOE ARPA-E REEACH program [1] has enabled this Phase 1 study that conceptualizes a commercial 154 passenger electric aircraft using renewable aviation fuel for range extension while meeting similar mission performance levels as current commercial aircraft. Commercial aviation accounts for about 2.5% of global CO2 emissions, and close to 5% of overall anthropogenic climate change due to the added accounting of contrail’s effects [2]. The sector has adopted a goal of carbon neutrality by 2050 [3]. 110 nations, and recently the new US administration, have embarked on work to address this important challenge. The US DOE has released a roadmap to enable the further development of sustainable aviation fuel (SAF) in the hopes that it could meet all of aviation’s fuel needs by 2050 [4]. However, SAF fuel price and sufficient future feedstock availability remains a concern [5]. Considering the first commercial biofuel flight demonstration 14 years ago [6] and that SAF still only comprises less than 0.1% of jet fuel use, the question arises as how it can ramp up to 100% use in the next 27 years. One option that has the potential to substantially reduce the need for SAF is to implement light-weight Solid Oxide Fuel Cells (SOFCs) that can efficiently utilize SAF or other sulfur-free hydrocarbon fuels. As opposed to lower temperature PEM (Proton Exchange Membrane) fuel cells that can use high-purity hydrogen, SOFC’s fuels are very flexible, ranging from low cost liquefied natural gas (LNG), renewable liquefied natural gas (RLNG), to SAF, to generate clean electrical power for use in aviation propulsion and auxiliary power units [7] [8]. Research progress is needed to enable SOFCs to achieve 3.0 kW/kg power density, making them viable for aviation [9]. The DOE’s Advanced Research Projects Agency – Energy (ARPA-E) has therefore initiated an aviation SOFC R&D program that is anticipated to dramatically reduce aircraft fuel use though the implementation of “Range Extenders for Electric Aviation with low Carbon and High efficiency” (REEACH) [1] for medium range commercial aircraft. This report summarizes the progress during phase 1 of the REEACH program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗