Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Validation of SolarWorld Modules at the NREL Regional Test Center Site (CRADA CRD-15-595 Final Report)

SolarWorld and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of SolarWorld’s Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗

Testbeds for test Readiness: Strategic Snapshot

Test bed engineering, monitoring for underground explosive and nuclear testing will be needed if the United States returns to a test posture of nuclear device testing. To maintain and rebuild the capability of test readiness, agile cost-effective test beds are needed and LANL as well as NNSS are the perfect locations to do this. Shallow and deep boreholes should be created to research containment science, diagnostic placement and optimization, coupling and emplacement science, tracer use for fracture and cratering research, and validation of test article performance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out [Slides]

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Effect of Micro-Structural Dispersity of SiMo Ductile Iron on High Temperature Performance during Static Oxidation

High silicon and molybdenum (SiMo) ductile iron is commonly used for car exhaust systems, and its micro-structural dispersity depends on intrinsic parameters, which include alloy composition and inoculation efficiency, as well as extrinsic factors, such as casting wall thickness and molding material, which define cooling rate during solidification. Micro-structural dispersity is referred to as the degree of heterogeneity of sizes of structural constituencies within the microstructure. A variation in the micro-structural dispersity could impact the high temperature performance of SiMo ductile iron during static oxidation and transient thermo-mechanical loading conditions. In this study, static high temperature tests were performed on SiMo ductile iron solidified in a casting with varying wall thicknesses from 5 mm to 100 mm. The faster solidified specimens (taken from near chilled casting surfaces) had extremely high micro-structural dispersity as compared to the thicker section samples. After thermal exposure, each of the samples were characterized using 2D sections and 3D µCT images, and the results indicated an order of magnitude difference in graphite phase dispersity. The surface degradation was quantified after static oxidation experiments were implemented at temperature intervals between 650 °C and 800 °C. Non-destructive µCT 3D analysis and SEM/EDS were performed on cross sections and used to quantify the scale topology and structure. Carbon analysis was used to decouple the scale formation and decarburization phenomena that occurred within the samples. These methods enabled the quantification of the oxidation of the SiMo cast iron with different micro-structural dispersity levels after being exposed to high temperature static oxidation. Additionally, the complex material behavior during oxidation-assisted transient thermo-mechanical loading will be presented in a separate article.

36 MATERIALS SCIENCE↗

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

A317_Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Development of Nanocomposite Coatings for Future Large-Scale Time Projection Chambers

In the context of this award we tested the performance of thin high-resistivity coatings for their potential usage as field shaping systems in future large scale xenon Time Projection Chambers (TPC). A successful implementation of such thin coatings would likely simplify the design of potential future detectors, allowing to overcome some of the challenges observed with traditional systems constituted by massive discrete electrodes. We studied a wide range of materials and characterized their optical and electrical performances as functions of temperature and wavelength. The measurement campaign indicated that uniform coatings covering the full PTFE substrate (usually used as reflector in LXe TPCs) impact too severely on the light collection performance of such detectors when used with deep UV light. Despite tuning the composition and thicknesses of nanocomposite coatings, we were not able to identify a single coating, properly working at LXe temperature, that would simultaneously fulfill the resistance and optical requirements. Following the risk mitigation strategy identified in the proposal we moved the focus of the R&D to identify proper materials that, when coated with grid-like patterns on PTFE, would not alter meaningfully its optical properties (with respect to bare PTFE panels) but would still serve as effective field shaping systems, properly containing the drift field in TPC detectors. Among the various materials we identified germanium as the most promising one, providing a good adhesion to PTFE and the proper range of sheet resistivity. The Ge-patterned coating tested within a small scale LXe TPC showed good performance as a field shape system and, as desired, did not reduce the detector light yield. These results are encouraging and such technology should further be investigated as a potential alternative to more traditional field shaping electrodes. Incidentally, in the context of this R&D, we stumbled upon an unexpected behavior suggesting that some of the treatments performed on the PTFE panels, in preparation of the coatings, meaningfully boosted the PTFE reflectivity. The most probable candidate is the O2 plasma cleaning procedure. This hypothesis will be tested in the near future by operating the small scale TPC at UChicago first with regular PTFE panels and then with panels bombarded with O2 plasma (but no coatings). This finding, if confirmed, might open up the possibility of further boosting UV light collection in future large detectors by performing such a treatment on the PTFE surfaces.

36 MATERIALS SCIENCE↗

Hanford Double Shell Waste Tank Corrosion Studies FY2020 (Final Report)

For fiscal year (FY) 2020, the Savannah River National Laboratory (SRNL) focused on three experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of deposits on the tanks’ inner sidewalls and bottoms. The second task studied vapor space corrosion (VSC) of the secondary liner using two commercially available vapor corrosion inhibitors (VCIs) at manufacturer recommended dosages. Finally, the third task investigated the long-term open circuit potential (OCP) drift for mill-scale coupons, coupons with polished surfaces, and partial mill-scale coupons that were exposed to tank waste simulants. Additional tests were performed to evaluate the OCP drift as a function of the quantity and composition of organic compounds added to the simulant. A test that was included in the matrix that established the new chemistry limits for tank corrosion, but was previously unreported, was presented and reviewed as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-cost sensors and analytics for a digital factory

ORNL Manufacturing Demonstration Facility and Perisense worked on a low-cost solution for machining process monitoring to enable a digital factory. Enabling machine connectivity for digital factors is expensive for many small to medium manufacturers. The hypothesis for the research project is that a lowcost sensor suite, which can be retrofitted to a legacy machine tool or a new machine tool, can effectively provide real-time, in-situ sensing for manufacturing processes, which can enable improvements in process performance and efficiency. The Perisense sensor node was installed on the Haas TM1 machine with a current sensor and an accelerometer. Cutting tests were performed at different process parameters and sensor data was recorded. Results show a correlation of the current sensor to the spindle load. The accelerometer, mounted on the machine base, showed a correlation to the spindle speed as well as the spindle load. The sensor data can be used to monitor the machining process and provide insights on the machine spindle load utilization.

42 ENGINEERING↗

Final Status Report Confirming Completion of Mechanical Testing of HFIR Irradiated Nanocomposite Materials

This report provides a final status report on the in-cell mechanical testing of High Flux Isotope Reactor (HFIR)-irradiated nanodispersion-strengthened materials at the Irradiated Materials Examination and Testing (IMET) facility. All tension tests were performed at room temperature with a nominal strain rate of 0.018 mm/mm/min using shoulder-loading grip sets by following the standard testing procedure in ASTM E8/E8M. Round 1 (unirradiated) and round 2 (0.7 dpa) testing was completed in FY 2021. This report confirms completion of round 3 (1.4 dpa) and round 4 (2.1 dpa) tensile testing in FY 2022 with examples of test data collected on select sample conditions. Additionally, the report includes IDs of samples selected for shipment to Idaho National Laboratory (INL) for additional characterization.

36 MATERIALS SCIENCE↗

Development of Corrosion Resistant Coatings for Structural Materials for Liquid Fueled Molten Salts Reactors Applications (Final Report)

Current structural alloys, code certified for the MSRs temperature ranges, contain high levels of chromium, making them highly susceptible to molten halide salt corrosion. One potential solution to circumvent the need for code certification of novel alloys, which is expensive and time consuming, is to design claddings that will protect the underlying code certified materials from corrosion damage during operation. In this work, we examined the corrosion of Ni and Cu electroplated, Ni and CuNi weld overlay, Mo-laser clad, and carburized claddings on SS316H for use in molten salt reactor environments. After characterization of the cladded materials (Task 1), static corrosion tests were used to assess corrosion resistance of the claddings in typical molten fluoride salts (Task 2). The corrosion tests were performed in molten FLiNaK at 700°C up to 1000 hours. Pre- and post-corrosion Scanning Electron Microscopy (SEM), energy-dispersive-spectroscopy (EDS), Transmission Electron Microscopy (TEM), X-ray Diffraction (XRD) and glow-discharge-optical-emission-spectroscopy (GDOES) were performed on cladding cross-sections and surfaces to evaluate degradation. The Cu and Ni electroplated samples, as well as the carburized samples, showed excellent corrosion resistance relative to the bare SS316H. To assess high temperature cladding stability, ageing experiments were performed at temperatures up to 900 C in inert atmosphere for the electroplated and carburized samples and a diffusion model was developed to predict long term cladding behavior (Task 3). It was found that the Cu cladding was basically insensitive to the high temperature ageing, except for small secondary phases forming at the interface. On the other hand, the Ni electroplated cladding experienced significant interdiffusion. Nevertheless, the gain in corrosion resistance for a 100μm Ni electroplated cladding is phenomenal, with more than 50% reduction in chromium dissolution from the substrate material for the first 15 years of salt exposure at 700°C. To assess radiation resistance and phase stability, high-temperature 4MeV Ni heavy ion irradiation was performed across the cladding/substrate interface up to 50 displacement-per-atom (DPA) at 500°C and 700°C to assess the phase stability and irradiation behaviors of the electroplated systems (Task 4). The Ni and Cu electroplated systems did not experience void swelling at the contrary to the SS316H substrate due to their nanocrystalline nature. Some level of recrystallization was observed in the cladding, as well as radiation induced segregation and enhanced diffusion. The interface acted as a potent sink for point defects with the presence of a void denuded zone. The mechanical properties of the claddings were assessed using thermal shock, micro-indentation, nano-indentation, and four-point bend testing experiments (Task 5). These experiments were performed on the claddings in as-received, corroded, irradiated, and thermally aged states to determine the effects of typical molten salt reactor environments on cladding integrity. No significant mass loss was observed after repeated thermal shocks. While the electroplated samples softened after high-temperature ageing, irradiation hardening compensate this effect, such that there is little different with the as-received materials. The results of these experiments suggest that the electroplated (copper/nickel) show the greatest promise for application in molten salt reactor development. These claddings prevented any chromium dissolution from occurring during the static corrosion experiments. Additionally, they demonstrated favorable properties for high temperature diffusion, phase stability, interfacial mechanical properties, and irradiation resistance. Weld-overlay cladding are also of great interest and could reach properties similar to the electroplated samples upon optimization (especially with multiple weld passes). The carburized SS316H showed excellent behavior as well, but more work needs to be done to assess their long-term stability. Finally, the Mo-laser clad system was not pursued further due to the manufacturing challenges. It is also worth noting that the Ni cladding systems should behave relatively well in terms of weldability since the Ni-weld overlay microstructure and associated corrosion rate are sound. While the NiCu weld-overlay has even lower corrosion rates than the Ni-weld overlay, more studies on welding of Cu-electroplated systems are necessary since Cu clusters are known to embrittle steels.

36 MATERIALS SCIENCE↗

Intermediate Scale Test Platform Conceptual Design and Hybrid Resin Performance Evaluation Recommendations

Recent laboratory evaluations demonstrated that further testing of alternative hybrid resins is warranted for their potential use as part of the 200 West Area (200W) pump-and-treat (P&T) remedy. 200W P&T has been treating technetium (Tc) since 2012 and uranium (U) since 2015 via two separate ion exchange (IX) treatment units: a single treatment train (i.e., a three-vessel system) for the removal of uranium utilizing a gel strong base anion (SBA) exchange resin, Dowex 21K; and two parallel treatment trains for the removal technetium using a gel SBA resin, Purolite® A532E. While these resins have been removing these contaminants effectively, new hybrid resins can provide additional benefits of further optimizing the IX treatment unit capacities and addressing additional treatment needs (e.g., Cr(VI)) by removing multiple contaminants simultaneously and/or through specific design configurations. Some of these resins also demonstrated some level of removal for I-129 which would be significant for expansion of the P&T into the 200 East Area. This document provides design recommendations for an intermediate scale test platform (ISTP) to evaluate alternative hybrid IX resin performance under conditions approaching field scale and using 200W P&T process groundwater. Results from the ISTP will provide the technical basis required to inform alternative IX resin selection in future 200W P&T facility operations where the treatment of multiple contaminants of concern may be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A comparative analysis of numerical approaches for the description of gas flow in clay-based repository systems: From a laboratory to a large-scale gas injection test

There is nowadays a consensus among many countries that geological disposal is a favourable solution for the long-term management. Although different host formations and different barrier systems are under consideration around the world, clay-based materials form an important component for waste isolation in most national programmes. Hence, a good comprehension of the effect of gas flow on the hydro-mechanical behaviour of clay-based soils is essential, both at laboratory and field scale. Task B under the international cooperative project DECOVALEX-2023 has recently shown that, after some enhancement, models can be employed to reproduce laboratory scale tests, even with different sample geometries 37 . However, further work is required to understand whether they can be applied to simulate a large-scale experiment. Up-scaling of models for the advective transport of gas through clay-based low permeable material presents a number of problems related to the difficulty in obtaining consistent hydrogeological parameters and constitutive relationships at both laboratory and field scale. Based on a unique dataset from a large-scale gas injection test (Lasgit) performed at the Äspö Hard Rock Laboratory (Sweden), Task B within DECOVALEX-2023 has explored the refinement of these numerical strategies applied to the simulation of gas flow. Work performed within the task reveals that codes do not need to be substantially modified from the laboratory models to reproduce full-scale tests: indeed, model parameters calibrated and validated at laboratory scale have been applied to predict field scale gas flow at Lasgit, including peak gas pressure and injected cumulative gas volume. By means of (1) the introduction of interfaces between blocks to reflect the experimental configuration and the (2) adjustment of some parameters (e.g., higher permeability), the updated models are able to represent most of the key features observed in the experimental data, even at a large scale.

Tamayo-Mas, E↗

High-temperature oxidation and quenching of chromium-coated zirconium alloy ATF cladding tubes with and w/o pre-damage

Chromium-coated zirconium alloys are one of the promising candidates for accident-tolerant fuel cladding (ATF) tubes for light water reactors (LWRs). In this study, the high temperature oxidation and degradation of two types of Cr coatings (cold spray and physical vapor deposition) with and without pre-damage by scratches were investigated on prototype rod segment samples filled with ZrO 2 pellets and tightly sealed with welded end caps. Isothermal tests at 1100 and 1200 °C were terminated by quenching with water; transient tests were performed up to 1500–1600 °C until complete coating failure. The positive effect of both types of Cr coatings was observed in all tests. Pre-damaged specimens showed only locally increased oxidation of the scratched zone, but no negative effects on the adjacent Cr coating. Finally, the behavior of the two types of coatings is compared and the degradation mechanisms are discussed based on hydrogen release data, extensive metallographic post-test examinations, and the current state of global research.

36 MATERIALS SCIENCE↗

Formulation and calibration of two-dimensional constitutive models for composite structures based on panel tests

Steel Plate Concrete (SC) composite members have been widely adopted because of its cost-efficiency and enhanced structural behavior. While researchers have attempted to study its in-plane shear behavior in the past twenty years, very limited number of large-scale pure shear tests were performed due to the challenge of experimental set-up and the availability of facilities. In this paper, a series of uniaxial loading tests and two full-scale pure shear panel tests of SC members were reported, on which the “mechanics-based Membrane Model of SC elements (MM-SC)” is developed. The MM-SC model is based on the fixed-angle crack formulation and the smeared-crack formulation, in which the experimental-based uniaxial constitutive models are implemented, considering the local buckling of faceplate, the tension stiffening of steel plate, the strength degradation of cracked concrete and the confinement effect of concrete. The proposed MM-SC model is subsequently incorporated into the object-oriented software OpenSEES. Finally, the simulation results of proposed model well predict the SC test observations in terms of critical branch points and structural behaviors, including initial stiffness, cracking strength, post-crack stiffness, yield strength, maximum strength, and failure modes.

42 ENGINEERING↗

MicroFisher: Fungal taxonomic classification for metatranscriptomic and metagenomic data using multiple short hypervariable markers

AbstractProfiling the taxonomic and functional composition of microbes using metagenomic (MG) and metatranscriptomic (MT) sequencing is advancing our understanding of microbial functions. However, the sensitivity and accuracy of microbial classification using genome– or core protein-based approaches, especially the classification of eukaryotic organisms, is limited by the availability of genomes and the resolution of sequence databases. To address this, we propose the MicroFisher, a novel approach that applies multiple hypervariable marker genes to profile fungal communities from MGs and MTs. This approach utilizes the hypervariable regions of ITS and large subunit (LSU) rRNA genes for fungal identification with high sensitivity and resolution. Simultaneously, we propose a computational pipeline (MicroFisher) to optimize and integrate the results from classifications using multiple hypervariable markers. To test the performance of our method, we applied MicroFisher to the synthetic community profiling and found high performance in fungal prediction and abundance estimation. In addition, we also used MGs from forest soil and MTs of root eukaryotic microbes to test our method and the results showed that MicroFisher provided more accurate profiling of environmental microbiomes compared to other classification tools. Overall, MicroFisher serves as a novel pipeline for classification of fungal communities from MGs and MTs.

Wang, Haihua↗

Structural, Thermal, and Mechanical Characterization of a Thermally Conductive Polymer Composite for Heat Exchanger Applications

Polymer composites are being considered for numerous thermal applications because of their inherent benefits, such as light weight, corrosion resistance, and reduced cost. In this work, the microstructural, thermal, and mechanical properties of a 3D printed polymer composite with high thermal conductivity are examined using multiple characterization techniques. Infrared spectroscopy and X-ray diffraction reveal that the composite contains a polyphenylene sulfide matrix with graphitic fillers, which is responsible for the high thermal conductivity. Furthermore, differential scanning calorimetry determines that the glass transition and melting point of the composite are 87.6 °C and 285.6 °C, respectively. Thermogravimetric analysis reveals that the composite is thermally stable up to ~400 °C. Creep tests are performed at different isotherms to evaluate the long-term performance of the composite. The creep result indicates that the composite can maintain mechanical integrity when used below its glass transition temperature. Nanoindentation tests reveal that modulus and hardness of the composite is not significantly influenced by heating or creep conditions. These findings indicate that the composite is potentially suitable for heat exchanger applications.

36 MATERIALS SCIENCE↗