Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Effect of temperature gradient on the optical quality of mercurous chloride crystals

Single crystals of mercurous chloride were grown at temperature gradients of 8, 11 and 17 K/cm by the physical vapor transport method. The optical quality of these crystals was evaluated by measuring bulk scattering and inhomogeneity of refractive index by birefringence interferometry. It was observed that a high temperature gradient at the solid-vapor interface induced thermal stresses and crystals showed higher scattering and irregular fringes.

Singh, N. B.↗

A fiber-coupled heterodyne interferometric displacement sensor

Space-based interferometers and large segmented reflectors will require precision metrology with nanometer accuracy for active control systems. This paper summarizes an experimental study of an optical heterodyne interferometer with resolution of about 3 nm. Optical signals are carried to and from the interferometer by optical fibers to avoid thermally loading the reflector panels. Heterodyne detection provides far greater precision than does traditional interferometry.

Nerheim, Noble↗

Extracting Zero-Gravity Surface Figure of a Mirror

The technical innovation involves refinement of the classic optical technique of averaging surface measurements made in different orientations with respect to gravity, so the effects of gravity cancel in the averaged image. Particularly for large, thin mirrors subject to substantial deformation, the further requirement is that mount forces must also cancel when averaged over measurement orientations. The zerogravity surface figure of a mirror in a hexapod mount is obtained by analyzing the summation of mount forces in the frame of the optic as surface metrology is averaged over multiple clockings. This is illustrated with measurements taken from the Space Interferometry Mission (SIM) PT-Ml mirror for both twofold and threefold clocking. The positive results of these measurements and analyses indicate that, from this perspective, a lighter mirror could be used; that is, one might place less reliance on the damping effects of the elliptic partial differential equations that describe the propagation of forces through glass. The advantage over prior art is relaxing the need for an otherwise substantial thickness of glass that might be needed to ensure accurate metrology in the absence of a detailed understanding and analysis of the mount forces. The general insights developed here are new, and provide the basic design principles on which mirror mount geometry may be chosen.

Bloemhof, Eric E.↗

Laser Interferometry for Gravitational Wave Observation: LISA and LISA Pathfinder

The Laser Interferometer Space Antenna (LISA) is a planned NASA-ESA gravitational wave observatory in the frequency range of 0.1mHz-100mHz. This observation band is inaccessible to ground-based detectors due to the large ground motions of the Earth. Gravitational wave sources for LISA include galactic binaries, mergers of supermasive black-hole binaries, extreme-mass-ratio inspirals, and possibly from as yet unimagined sources. LISA is a constellation of three spacecraft separated by 5 million km in an equilateral triangle, whose center follows the Earth in a heliocentric orbit with an orbital phase offset oF 20 degrees. Challenging technology is required to ensure pure geodetic trajectories of the six onboard test masses, whose distance fluctuations will be measured by interspacecraft laser interferometers with picometer accuracy. LISA Pathfinder is an ESA-launched technology demonstration mission of key LISA subsystems such us spacecraft control with micro-newton thrusters, test mass drag-free control, and precision laser interferometry between free-flying test masses. Ground testing of flight hardware of the Gravitational Reference Sensor and Optical Metrology subsystems of LISA Pathfinder is currently ongoing. An introduction to laser interferometric gravitational wave detection, ground-based observatories, and a detailed description of the two missions together with an overview of current investigations conducted by the community will bc discussed. The current status in development and implementation of LISA Pathfinder pre-flight systems and latest results of the ongoing ground testing efforts will also be presented

Guzman, Felipe↗

SIM Configuration Evolution

The Space Interferometry Mission (SIM) is a space-based 10 m baseline Michelson interferometer. Planned for launch in 2005 aboard a Delta III launch vehicle, or equivalent, its primary objective is to measure the positions of stars and other celestial objects with an unprecedented accuracy of 4 micro arc seconds. With such an instrument, tremendous advancement can be expected in our understanding of stellar and galactic dynamics. Using triangulation from opposite sides of the orbit around the sun (i.e. by using parallax) one can measure the distance to any observable object in our galaxy. By directly measuring the orbital wobble of nearby stars, the mass and orbit of planets can be determined over a wide range of parameters. The distribution of velocity within nearby galaxies will be measurable. Observations of these and other objects will improve the calibration of distance estimators by more than an order of magnitude. This will permit a much better determination of the Hubble Constant as well as improving our overall understanding of the evolution of the universe. SIM has undergone several transformations, especially over the past year and a half since the start of Phase A. During this phase of a project, it is desirable to perform system-level trade studies, so the substantial evolution of the design that has occurred is quite appropriate. Part of the trade-off process has addressed two major underlying architectures: SIM Classic; and Son of SIM. The difference between these two architectures is related to the overall arrangement of the optical elements and the associated metrology system. Several different configurations have been developed for each architecture. Each configuration is the result of design choices that are influenced by many competing considerations. Some of the more important aspects will be discussed. The Space Interferometry Mission has some extremely challenging goals: millikelvin thermal stability, nanometer stabilization of optics, picometer measurement of wavefront, and others. In order to meet these goals, a significant amount of technological development is required. Although there has been a program operating for about a decade developing technologies specifically to address the challenges of space-based interferometry, there still remains a tremendous effort to achieve the incredible accuracy required of SIM. The projected viability of some of these areas has influenced design choices during the evolution of the many configurations that have been developed. For instance, the perceived complexity of the IR laser metrology system used to measure and control the positions of key optical elements was the strongest discriminator between the two architectures, and led to a decision to select SOS rather than Classic in early 1998. More recently, an appreciation of the sensitivity to beam-walk within the SOS architecture is forcing a reconsideration of that decision. At the time of submission of this abstract, there is some hope that a full-aperture metrology system may alleviate this issue. In addition to describing the current configuration of SIM, the influence of a few selected areas on the evolution of the configuration will be discussed.

Aaron, Kim M.↗

Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition

The 1 𝑆 0 − 3 𝑃 0 clock transition in strontium serves as the foundation for the world’s best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope 87 Sr but strongly forbidden in bosonic isotopes. Here, we demonstrate coherent excitation of the clock transition in bosonic 88 Sr using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to 50 kHz using W/cm 2 laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of Convective Transport of Solute and Impurities on Defect-Causing Kinetics Instabilities

For in-situ studies of the formation and evolution of step patterns during the growth of protein crystals, we have designed and assembled an experimental setup based on Michelson interferometry with the surface of the growing protein crystal as one of the reflective surfaces. The crystallization part of the device allows optical monitoring of a face of a crystal growing at temperature stable within 0.05 C in a developed solution flow of controlled direction and speed. The reference arm of the interferometer contains a liquid-crystal element that allows controlled shifts of the phase of the interferograms. We employ an image processing algorithm which combines five images with a pi/2 phase difference between each pair of images. The images are transferred to a computer by a camera capable of capturing 6-8 frames per second. The device allows data collection data regarding growth over a relatively large area (approximately .3 sq. mm) in-situ and in real time during growth. The estimated dept resolution of the phase shifting interferometry is about 100 A. The lateral resolution, depending on the zoom ratio, varies between 0.3 and 0.6 micrometers. We have now collected quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, position on the facet, crystal size and temperature with the proteins ferritin, apoferritin and thaumatin. Comparisons with theory, especially with the AFM results on the molecular level processes, see below, allow tests of the rational for the effects of convective flows and, as a particular case, the lack thereof, on step bunching.

Vekilov, Peter G.↗

Analysis of Spacelab-III Reconstructed Wavefronts by Non-Holographic Methods

Holography has been used in several past space missions. One popular experimental mode deals with study of fluid refractive properties in the crystal growth cell. The perceived advantage of holography is that it stores and reconstructs wavefronts so that a complete information is available later on ground. That means the wavefront can be analyzed not only by traditional holographic interferometry but other means as well. We have successfully demonstrated two such means being described here. One is deflectometry using a Ronchi grating and the other confocal optical processing. These results, using holograms from Spacelab-III mission dealing with triglycine sulfate crystal growth clearly demonstrate that a single hardware (holography) can do the task of several fluid experimental systems. Finally, not experimentally demonstrated, the possibility of some other analysis modes like speckle techniques and video holography using the reconstructed wavefronts have been described. Since only traditional holographic interferometry has been used in the past leading to the argument that non-holographic interferometry hardware in space could do the job, the present study firmly establishes advantage of holography.

Vikram, Chandra S.↗

Wide angle astrometric demonstration on the micro-arcsecond metrology testbed for the space interferometry mission

The Space Interferometry Mission (SIM) requires fringe measurements to the level of picometers in order to produce astrometric data at the micro-arc-second level. To be more specific, it is necessary to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer to a few hundreds of picometers. The internal path is measured with a small heterodyne metrology beam, whereas the starlight fringe position is estimated with a CCD sampling a large concentric annular beam. One major challenge for SIM is to align the metrology beam with the starlight beam to keep the consistency between these two sensors at the system level while articulating the instrument optics over the field of view.

metrology↗

Surface electrical properties experiment. Part 2: Theory of radio-frequency interferometry in geophysical subsurface probing

The radiation fields due to a horizontal electric dipole laid on the surface of a stratified medium were calculated using a geometrical optics approximation, a modal approach, and direct numerical integration. The solutions were obtained from the reflection coefficient formulation and written in integral forms. The calculated interference patterns are compared in terms of the usefulness of the methods used to obtain them. Scattering effects are also discussed and all numerical results for anisotropic and isotropic cases are presented.

Kong, J. A.↗

Sound velocities in shock-compressed soda lime glass: Melting and liquid-state response

Longitudinal sound velocities (and elastic moduli) were determined in soda lime glass (SLG) at peak shock stresses ranging between 40 and 90 GPa. Laser interferometry was used to obtain particle velocity histories and sound velocities by impacting SLG samples on lithium fluoride (LiF) optical windows. In all experiments, the SLG response consists of a sharp jump to a constant state followed by a release wave. The measured longitudinal sound velocities and moduli showed a marked decrease between 52 and 58 GPa, providing experimental evidence for the transformation from an amorphous solid to a liquid in shock-compressed SLG. Furthermore, the stress threshold (~55 GPa) for melting in SLG is considerably lower than the threshold reported in shock-compressed fused silica (~72 GPa), showing the effect of network-modifying cations on the onset of melting. The relative values of sound velocities, shock velocities, and the Hugoniot slopes—between 58 and 90 GPa—are fully consistent with the thermodynamic response of a shock-compressed liquid. Using the experimental results, the Grüneisen parameter (Γ) values were determined for liquid SLG to 90 GPa and then used to provide the Mie-Grüneisen equation of state for liquid SLG.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Increasing Baselines and Precision of Optical Interferometers Using Two-Photon Interference

Observations using interferometers provide sensitivity to features of images on angular scales much smaller than any single telescope, on the order of Δθ ~ λ/b where b is the interferometric baseline. Present-day optical interferometers are essentially classical, interfering single photons with themselves. However, there is a new wave of interest in interferometry using multiple photons, whose mechanisms are inherently quantum mechanical, which offer the prospects of increased baselines and finer resolutions among other advantages. We will discuss recent ideas and results for quantum-assisted interferometry using the resource of entangled pairs, and specifically a two-photon amplitude technique aimed at improved precision in astrometry.

47 OTHER INSTRUMENTATION↗

Binary Amplitude Reflection Gratings for X-ray Shearing and Hartmann Wavefront Sensors

New, high-coherent-flux X-ray beamlines at synchrotron and free-electron laser light sources rely on wavefront sensors to achieve and maintain optimal alignment under dynamic operating conditions. This includes feedback to adaptive X-ray optics. We describe the design and modeling of a new class of binary-amplitude reflective gratings for shearing interferometry and Hartmann wavefront sensing. Compact arrays of deeply etched gratings illuminated at glancing incidence can withstand higher power densities than transmission membranes and can be designed to operate across a broad range of photon energies with a fixed grating-to-detector distance. Coherent wave-propagation is used to study the energy bandwidth of individual elements in an array and to set the design parameters. We observe that shearing operates well over a ±10% bandwidth, while Hartmann can be extended to ±30% or more, in our configuration. We apply this methodology to the design of a wavefront sensor for a soft X-ray beamline operating from 230 eV to 1400 eV and model shearing and Hartmann tests in the presence of varying wavefront aberration types and magnitudes.

47 OTHER INSTRUMENTATION↗

Measure of displacement around holes in composite plates subjected to quasi-static compression

Contour maps of thickness changes were obtained for three quasi-isotropic graphite-epoxy plates with central holes, loaded in compression. Thickness changes were determined for six load increments from nearly zero to within a few percent of the failure load. The largest change of thickness occurred near the hole but not at the boundary of the hole. Below 90 percent of the failure load, the thickness changes were nearly proportional to load. Irregularities of thickness changes occurred in zones of compressive stresses and they were attributed to localized fiber buckling. A new optical technique was developed to measure thickness changes with high sensitivity. It utilizes a comparatively simple means of holographic interferometry on both sides of the specimen, followed by additive moire to obtain thickness changes as the sum of the out-of-plane displacements. Sensitivity was 12.5 x 10 to the -6 power in. per fringe order. The fringe patterns represent thickness changes uniquely, even when specimen warpage and consequent out-of-plane displacements are very large.

Duke, J. C., Jr.↗

Synchronizing Photography For High-Speed-Engine Research

Light flashes when shaft reaches predetermined angle. Synchronization system facilitates visualization of flow in high-speed internal-combustion engines. Designed for cinematography and holographic interferometry, system synchronizes camera and light source with predetermined rotational angle of engine shaft. 10-bit resolution of absolute optical shaft encoder adapted, and 2 to tenth power combinations of 10-bit binary data computed to corresponding angle values. Pre-computed angle values programmed into EPROM's (erasable programmable read-only memories) to use as angle lookup table. Resolves shaft angle to within 0.35 degree at rotational speeds up to 73,240 revolutions per minute.

Chun, K. S.↗

Polarization considerations for optical systems II; Proceedings of the Meeting, San Diego, CA, Aug. 9-11, 1989

Various papers on polarization considerations for optical systems are presented. Individual topics addressed include: use of polarization methods in earth resources investigation, measurements of polarization scattering in the vacuum UV, the Space Shuttle as a polarization observation platform, analysis of spatial pseudodepolarizers in imaging systems, analysis of polarization effects in optical systems, and a low-polarization solar vector magnetograph. Consideration is given to polarization effects on astronomical spatial interferometry, measurement of the instrumental polarization of a high-resolution UV spectrometer, and the use of KD(asterisk)P modulators for polarization measurements of the sun.

Chipman, Russell A.↗

Comparison of Three Optical Methods for Measuring Model Deformation

The objective of this paper is to compare the current state-of-the-art of the following three optical techniques under study by NASA for measuring model deformation in wind tunnels: (1) video photogrammetry, (2) projection moire interferometry, and (3) the commercially available Optotrak system. An objective comparison of these three techniques should enable the selection of the best technique for a particular test undertaken at various NASA facilities. As might be expected, no one technique is best for all applications. The techniques are also not necessarily mutually exclusive and in some cases can be complementary to one another.

Burner, A. W.↗