Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Degradation of Fuel Cell Membrane Electrode Assemblies from Buses Operated More than 25,000 h

This study investigates the performance losses and degradation of proton-exchange-membrane fuel-cell stacks taken from the Alameda Contra Costa Transit District (AC Transit) bus system (Alameda and Contra Costa counties, California, United States) that were operated for over 25,000 h. Here, we focus on the origin of differences in electrochemical performance between beginning-of-life (BOL) and end-of-life states as well as diagnostic data acquired during the lifetime of the buses. In doing so, we employ in- and ex- situ characterization methods such as polarization curves, electrochemical impedance spectroscopy, electron microscopy, and X-ray characterization. Uniform degradation of the catalyst layer including Pt agglomeration/migration and electrode thinning was observed in all of the post-teardown measurements compared to BOL materials resulting from years of field operation. Despite these changes, the measured post-teardown performance suggests a sufficient output for the expected load, which indicate factors other than degradation of the membrane-electrode assemblies (MEAs) are likely responsible for the decommissioning of the stacks. The findings indicate that these MEA materials can enable long lifetime in fuel-cell vehicles, if the MEAs are not subjected to adverse operating conditions. The results also highlight the need for more in-vehicle diagnostics to maximize the lifetime of fuel cell vehicle (FCV) powerplants.

25 ENERGY STORAGE↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

WOMBAT (Windfarm Operations and Maintenance cost-Benefit Analysis Tool) WISDEM® [SWR-21-68]

The windfarm operations and maintenance cost-benefit analysis tool (WOMBAT) is software to simulate the operations and maintenance phase of either onshore or offshore windfarms. WOMBAT is a medium-fidelity tool that is designed to model turbine, cable, and substation failures at the subassembly level, but is flexible enough that individual component or asset-level modeling can also be performed. WOMBAT enables users to model technological improvements, the use of a wide range of service equipment from drone repairs and remote resets to heavy lift vessels and crawler cranes, to analyze cost trends with varying trade-offs in conjunction with energy production, availability and a growing range of metrics. This library provides a tool to simulate the operation and maintenance phase (O&M) of distributed, land-based, and offshore windfarms using a discrete event simulation framework. WOMBAT is written around the SimPy discrete event simulation framework. Additionally, this is supported using a flexible and modular object-oriented code base, which enables the modeling of arbitrarily large (or small) windfarms with as many or as few failure and maintenance tasks that can be encoded. Please note that this is still heavily under development, so you may find some functionality to be incomplete at the current moment, but rest assured the functionality is expanding. With that said, it would be greatly appreciated for issues or PRs to be submitted for any improvements at all, from fixing typos (guaranteed to be a few) to features to testing. Also available at: https://pypi.org/project/wombat/

Cooperman, Aubryn↗

Digital Twin Technology (“Morpheus”) for Optimized Building Operations [SWR-22-74]

The electrification of buildings is an important step to reducing greenhouse gas emissions across all industries. The management of increasingly electrified buildings is a complex pursuit, and there remains a need for cost-effective software capable of handling the computational burden required of such complexity. Through a partnership with Dallas Fort Worth (DFW) Airport, researchers at NREL have developed a digital twin modeling framework to optimize building operations, called Morpheus. Pairing predictive control with automatic fault detection and diagnostics, Morpheus decreases energy expenditures, costs, and faults for large facilities. Additionally, Morpheus employs artificial intelligence to continuously improve its performance using information provided by sensor systems, human experts with deep industry domain knowledge, and even from other similar machines or fleets of machines. Coupling this novel energy-management software with other digital twins, such as NREL’s Athena software for mobility operations, enables robust decision-making for asset and space management. The implementation of Morpheus at DFW has resulted in significantly improved HVAC system operations and reduced both peak power and overall energy consumption. This enhanced functionality comes at a more affordable price than previously developed digital twins and can be customized for other facilities’ geometries to provide optimal, individualized control of a facility’s energy consumption.

Chinde, Venkatesh↗

GNN Parameterized Differential Operators v.0.9

GNN Parametrized Differential Operators is an example code and layer implementation for using the parameterized differential operator used in conference submissions. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-2984 O

Potter, KevinMatthew↗

Canonical and Noncanonical Hamiltonian Operator Inference

SAND2024-08577O Canonical and Noncanonical Hamiltonian Operator Inference is research code that applies old and new model reduction algorithms to well-known and publicly available "toy" problems. It applies operator inference (OpInf) methods for model reduction to several benchmark hyperbolic partial differential equations: linear wave, Korteweg-de Vries, Benjamin-Bona-Mahoney, and linear elasticity. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

or-topas: Operations Research Toolkit for Pyomo Alternative Solutions

SAND2026-16702O OR-TOPAS: Operations Research Toolkit for Pyomo Alternative Solutions is a tool that enhances optimization applications defined by the Pyomo modeling library. It offers functions to generate optimal or near-optimal solutions, operating independently of Pyomo’s solver interface. Users can configure these functions with specific solver names and options, resulting in a custom solution object that returns a list of solutions. The OR-TOPAS library includes methods tailored to the properties of the model, such as binary integer programs versus linear programs, and specific solver interfaces like Gurobi. It does not provide models for specific applications, but it is applicable to a wide range of Pyomo optimization models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Siirola, John [Sandia National Lab. (SNL-CA), Live↗

Projecting Future Energy Production from Operating Wind Farms in North America. Part I: Dynamical Downscaling

Abstract New simulations at 12-km grid spacing with the Weather and Research Forecasting (WRF) Model nested in the MPI Earth System Model (ESM) are used to quantify possible changes in wind power generation potential as a result of global warming. Annual capacity factors (CF; measures of electrical power production) computed by applying a power curve to hourly wind speeds at wind turbine hub height from this simulation are also used to illustrate the pitfalls in seeking to infer changes in wind power generation directly from low-spatial-resolution and time-averaged ESM output. WRF-derived CF are evaluated using observed daily CF from operating wind farms. The spatial correlation coefficient between modeled and observed mean CF is 0.65, and the root-mean-square error is 5.4 percentage points. Output from the MPI-WRF Model chain also captures some of the seasonal variability and the probability distribution of daily CF at operating wind farms. Projections of mean annual CF (CF A ) indicate no change to 2050 in the southern Great Plains and Northeast. Interannual variability of CF A increases in the Midwest, and CF A declines by up to 2 percentage points in the northern Great Plains. The probability of wind droughts (extended periods with anomalously low production) and wind bonus periods (high production) remains unchanged over most of the eastern United States. The probability of wind bonus periods exhibits some evidence of higher values over the Midwest in the 2040s, whereas the converse is true over the northern Great Plains. Significance Statement Wind energy is playing an increasingly important role in low-carbon-emission electricity generation. It is a “weather dependent” renewable energy source, and thus changes in the global atmosphere may cause changes in regional wind power production (PP) potential. We use PP data from operating wind farms to demonstrate that regional simulations exhibit skill in capturing actual power production. Projections to the middle of this century indicate that over most of North America east of the Rocky Mountains annual expected PP is largely unchanged, as is the probability of extended periods of anomalously high or low production. Any small declines in annual PP are of much smaller magnitude than changes due to technological innovation over the last two decades.

Meteorology & Atmospheric Sciences↗

Visual Style Elements in Human–System Interface Design for Nuclear Power Operations: Does Style Affect Performance and Preference?

As the world increasingly adopts renewable and sustainable energy systems, transitionary solutions include nuclear power, which currently provides 20% of the United States’ electricity and is the largest single source of carbon-free electricity generation. Advanced reactors are a critical component of a carbon-free mixed energy portfolio that require careful design of first-of-a-kind control rooms. The application of Human Factors Engineering (HFE) is essential for scientific and iterative testing of novel human–system interface (HSI) concepts to ensure effective, efficient, and safe plant operations. Microworlds are simulators that use simplified physics models and control systems to distill nuclear power operations into essential functions. HFE scientists used the Rancor Microworld Simulator to obtain preference and performance metrics for novel and traditional static HSI design styles. Participants comprised advanced reactor company employees and nuclear industry consultants. A mixture of quantitative and qualitative data was captured. There was a preference for the basic graphical style that included high contrast and traditional color scheme elements. No single HSI design outperformed the others, and the participants did not perform better using their preferred HSI style. We report this experiment is the first in a series of HFE testing for HSIs in advanced reactor control room development. Clear user preferences emerged for elements within static displays. The cutting-edge neumorphic style was the least preferred. Future directions include tests of dynamic displays. HFE is used in evaluating and designing HSI devices that will improve the efficiency and safety of advanced nuclear power operations.

99 GENERAL AND MISCELLANEOUS↗

Solid particulate mass and number from ducted fuel injection in an optically accessible diesel engine in skip-fired operation

Ducted fuel injection (DFI) is a new combustion strategy that has been shown to significantly attenuate soot formation in diesel engines. While previous studies have used optical diagnostics and optical filter smoke number methods to show that DFI reduces in-cylinder soot formation and engine-out soot emissions, respectively, this is the first study to measure solid particle number (PN) emissions in addition to particle mass (PM). Furthermore, this study quantitatively evaluates the use of transient particle instruments for measuring particles from skip-fired operation in an optical single cylinder research engine (SCRE). Engine-out PN was measured using an engine exhaust particle sizer following a catalytic stripper, and PM was measured using a photoacoustic analyzer. The study improves on earlier preliminary emissions studies by clearly showing that DFI reduces overall PM by 76%–79% and PN for particles larger than 23 nm by 77% relative to conventional diesel combustion at a 1200-rpm, 13.3-bar gross indicated mean effective pressure operating condition. The degree of engine-out PM reduction with DFI was similar across both particulate measurement instruments used in the work. Through the use of bimodal distribution fitting, DFI was also shown to reduce the geometric mean diameter of accumulation mode particles by 26%, similar to the effects of increased injection pressure in conventional diesel combustion systems. This work clearly shows the significant solid particulate matter reductions enabled by DFI while also demonstrating that engine-out PN can be accurately measured from an optical SCRE operating in a skip-fired mode. Based on these results, it is believed that DFI has the potential to enable fuel savings when implemented in multi-cylinder engines, both by lowering the required frequency of active diesel particulate filter regeneration, and by reducing the backpressure imposed by exhaust filtration systems.

33 ADVANCED PROPULSION SYSTEMS↗

OPERATING EXPERIENCE AND ITS RELATIONSHIP TO EMBEDDED DIGITAL DEVICES IN SAFETY SYSTEMS

Interest in embedded digital devices (EDDs) for monitoring and providing control of components is increasing and the added functionality digital brings such as diagnostics, displays, control functions is welcomed in both the nuclear and other industries. As a result, pure analog-based components continue to disappear from the industrial I&C marketplace. Equipment with EDDs, also known by related terms such as smart devices, intelligent devices, and digital devices of limited functionality, can include sensors, breakers, priority logic modules, time delay relays, pumps, valve actuators, motor control centers, and uninterruptible power supplies. Not only is equipment consisting of analog and older digital technology being replaced with commercial grade products containing EDDs, but EDDs can also be retrofitted to work with existing components. EDDs may be installed physically within a component, such as in a relay. There are also external devices that some would not consider an EDD, but that operate in almost all technical ways identically to one internal to a component such as in a valve controller. In fact, the digital portions may be located hundreds of feet from the actual component.Due to the potential of being used in an identical manner and without alteration from their application in other industries, operating experience (OpE) for EDDs may be much more applicable than in the case of other more system level devices. Clear separation and independence of functionality provided with EDDs may also allow greater applicability of existing OpE from industry for changes that can be shown not to affect its safety function. However, OpE also demonstrates issues with different conditions between other industries and nuclear power plants, such as issues with undeclared changes or undeclared digital devices and the new failure modes they may introduce, issues with the reporting of OpE in industry, and a lack of transparency into OpE for EDDs.Understanding and addressing these issues will be key in the future use of EDDs in nuclear power plants, but failure rate data is difficult to obtain for EDDs, and lessons learned from the use of EDDs are difficult to collect and identify.Key words: embedded digital device, smart device, operating experience, failure modes

Muhlheim, Michael↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly used a highly enriched uranium and molybdenum alloy as the fuel and could be operated in steady-state or burst modes. The HPRR has recently been the object of an investigation to create a criticality benchmark. Such benchmarks are very important, as they are used primarily to show the accuracy of newly developed modeling codes and to help experimental validation and reactor licensing. The evaluated experiments considered in this paper were carried out between 1974 and 1986 from various HPRR activities such as steady-state subcritical, steady-state critical, and burst prompt super-critical operations of the reactor for dosimetry, irradiation, or training purposes. By using the HPRR experimental logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI, and a first version of a critical benchmark of the HPRR was developed following the International Criticality Safety Benchmark Evaluation Project (ICSBEP) guidelines for thorough description and uncertainty/sensitivity quantification. Unfortunately, in most of the evaluated experiments, the obtained difference between calculated and experimental k eff is around 1,000 pcm, corresponding to a relative error of approximately 1%, beyond the quality standards of the ICSBEP recommending a relative error below 0.1%. Moreover, the derived experimental uncertainty is high, around 4% relative, mainly due to the U-Mo fuel density uncertainty, but also from numerous other factors. For these reasons, the creation of a valuable critical benchmark from HPRR operation data is thus far compromised. In this paper, the different steps of the experiments’ evaluation are summarized, and the reasons for the experimental/calculation discrepancies and potential ways to solve them are explored. This paper also aims to remind us always to exercise considerable care when performing experimental work, and to record all the data possible for potential future uses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Seismically Detecting Nuclear Reactor Operations Using a Power Spectral Density (PSD) Misfit Detector

To explore the ability to indirectly detect and attribute various operations conducted at a nuclear reactor using waveform data, we investigated the seismic signals recorded near the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory in Oak Ridge, Tennessee. Specifically, we processed seismic data collected from a single seismoacoustic station, WACO, near the HFIR facility, and employed a power spectral density misfit detector to identify signals of interest and associate the detections with operational events. Initial results suggest that this method provides a promising means of regularly detecting at least 19 unique operations. Furthermore, with additional station deployment and more comprehensive data logs, we anticipate that future analysis will offer an additional means to seismically monitor nuclear reactors (such as HFIR) health and performance more accurately.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monitoring Operational States of a Nuclear Reactor Using Seismoacoustic Signatures and Machine Learning

Monitoring nuclear reactors is an important safety and security task with growing requirements. We explore the possibility of using seismic and acoustic data for inferring the power level of an operating reactor. Continuous data recorded at a single seismoacoustic station that is located about 50 m away from a research reactor was visualized and analyzed. The data show a clear correlation between seismoacoustic features and reactor main operational states. We designed a workflow that includes two machine learning (ML) models to classify the reactor operational states (OFF, transition, and ON) and estimate reactor power levels (10%, 30%, 50%, 70%, and 90%). We applied and compared five ML algorithms for the reactor OFF-transition-ON and four approaches for the power level classification. We also compared the performance of ML models trained with seismic-only, acoustic-only, and both types of data. Five-fold cross validations were implemented to assure a thorough evaluation of the model performances. Additionally, the results show the extreme boosting gradient algorithm worked best for the first model, whereas random forests performed best for the second model. Combining seismic and acoustic data leads to better performance than using a single type of data. Seismic data contributed more than acoustic data for both models. We reached an accuracy of 0.98 for reactor OFF and ON. The accuracies for the transition state and power levels are less optimal with a minimum accuracy of 0.66. However, our results suggest seismic and acoustic data contain useful information about the transition state as well as power levels. Seismic and acoustic data could be integrated with other observations to improve monitoring performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First SELAP Algorithm Operational Experience of the New LLRF 3.0 RF Control System

The JLAB LLRF 3.0 system has been developed and is replacing the 30-year-old LLRF systems in the CEBAF accelerator. The LLRF system builds upon 25 years of design and operational RF control experience (digital and analog), and our recent collaboration in the design of the LCLSII LLRF system. The new system also incorporates a cavity control algorithm using a fully functional phase and amplitude locked Self Exciting Loop (SELAP). The first system (controlling 8 cavities) was installed and commissioned in August of 2021. Since then the new LLRF system has been operating with cavity gradients up to 20 MV/m, and electron beam currents up to 350 uA. This paper discusses the operational experience of the LLRF 3.0 SELAP algorithm along with other software and firmware tools like cavity and klystron characterization and quench detection.

Plawski, T. E.↗

A Novel Technique for Pulsed Operation of Magnetrons without Modulation of Cathode Voltage

Modern pulsed superconducting accelerators of megawatt beams require efficient RF sources controllable in phase and power. For each Superconducting RF (SRF) cavity is desirable a separate RF source with power up to hundreds of kW with pulse duration in the millisecond range. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) is lower than that of the magnetrons, while the cost of a unit of RF power is much higher. Therefore the magnetron-based RF sources would significantly reduce the capital and operation costs in comparison with the traditional RF sources. A recently developed an innovative technique makes possible the pulsed generation of magnetrons powered below the self-excitation threshold voltage. This technique does not require pulse modulators to form RF pulses. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in pulsed modes with large duty factor. The developed technique and its experimental verification are considered and discussed.

43 PARTICLE ACCELERATORS↗

Development and Operation of PIP-II Injector Test, SSR1 Cryomodule, 325 MHz Amplifiers

The PIP-II Injector Test (PIP2IT) has successfully accelerated ionized hydrogen up to 17MeV through a superconducting, single spoke resonator (SSR1) cryomodule at Fermi National Accelerator Laboratory (FNAL). Each of the SSR1 cavities is tuned to 325MHz and requires up to 6 kW of RF power to accelerate 2mA of ionized hydrogen at the design gradients. RF power amplifiers, specialized for SRF cavity beam operations, were designed by Bhabha Atomic Research Center (BARC) and constructed in a collaboration between the BARC in Mumbai, India and the Electronics Corporation of India Limited (ECIL) in Hyderabad, India. The RF amplifiers meet the specifications and requirements mutually approved between BARC and FNAL. They operate at 325 MHz with a linear power output of 7 kW in both CW and pulse mode. The amplifiers are compatible with the FNAL accelerator personnel safety system and the cavity protection interlocks. Access to controls and internal diagnostic instrumentation are compatible with EPICS control standards. This paper gives details about RF power amplifier development within the Department of Atomic Energy (DAE), India and the operational details with PIP2IT at FNAL.

43 PARTICLE ACCELERATORS↗

FRIB Transition to User Operations, Power Ramp Up, and Upgrade Perspectives

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. During the first 12 months of user operations, the FRIB accelerator complex delivered 5250 beam hours, including 1528 hours to nine science experiments conducted with primary beams of 36Ar, 48Ca, 70Zn, 82Se, 124Xe, and 198Pt at beam energies >200 MeV/u; 2724 hours for beam developments, studies, and tuning; and 998 hours to industrial users and non-scientific programs using the FRIB Single Event Effect (FSEE) beam line. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on FRIB status and progress since SRF2021, emphasizing lessons learned during the transition from beam commissioning to machine operations, challenges and resolutions for the power ramp-up, progress with accelerator improvements, and R&D for the energy upgrade.

43 PARTICLE ACCELERATORS↗