Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear science & technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A New Era of Nuclear Criticality Experiments: The First 10 Years of Godiva IV Operations at NCERC

The work presented in this paper focuses on the first 10 years (2011–2020) of Godiva IV operations at the National Criticality Experiments Research Center (NCERC). Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5% molybdenum for strength. Godiva is one of the last such critical assemblies in the United States and can be used for studies of super-prompt-critical behavior as well as irradiations and demonstrations. An overview of the startup of Godiva IV at NCERC is given followed by a summary of the experiments performed utilizing Godiva IV over the first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Flattop Operations at NCERC

The Flattop critical assembly was built and operated from 1958 through 2004 at the Pajarito Site (Technical Area-18), home to the Los Alamos Critical Experiments Facility. Flattop was disassembled in 2005 and refurbished over the course of 3 years. In 2008, Flattop was installed in the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility at the Nevada National Security Site. Startup of Flattop with a uranium core occurred in 2011. This paper details the first 10 years of Flattop operations at NCERC (2011–present).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Comet Operations at NCERC

Comet is a general-purpose, heavy-duty, vertical-lift assembly designed for flexibility in conducting a variety of critical experiments. It is currently located at the National Criticality Experiments Research Center (NCERC) in Nevada. In the past, Comet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). The Comet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The first critical experiment performed on Comet at NCERC was a verification of one of the previous configurations of the Zeus experiment series. Over the next 10 years, many additional experiments followed including other Zeus configurations as well as completely new designs. This paper discusses the Comet vertical-lift assembly, the transition from LACEF to NCERC, and a selection of experiments that have been performed on Comet during its first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Planet Operations at NCERC

Planet is a vertical-lift assembly machine currently located at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site. In the past, Planet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). Following the de-inventorying of LACEF, the Planet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The Class Foils experiment, which involves stacking highly enriched uranium foils to obtain a critical configuration, was the first critical experiment performed on Planet. As a major component of the Nuclear Criticality Safety Class taught for the U.S. Department of Energy (DOE) Nuclear Criticality Safety Program, the Class Foils experiment allows personnel from all over the DOE complex to handle nuclear material and to complete the approach to critical safely and successfully. This paper describes the Planet vertical assembly and recent engineering upgrade and a selection of the experiments that have been performed on Planet since its transition to NCERC 10 years ago.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-neutrino double electron capture of 124 Xe in the first LUX-ZEPLIN exposure

The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of 124Xe through the process of two-neutrino double electron capture, utilizing a 1.39 kg × yr isotopic exposure from the first LZ science run. A half-life of $T$$^{2v2EC}_{1/2}$ = (1.09 ± 0.14 stat ± 0.05 sys ) x 10 22 yr is observed with a statistical significance of 8.3σ, in agreement with literature. First empirical measurements of the KK capture fraction relative to other K-shell modes were conducted, and demonstrate consistency with respect to recent signal models at the 1.4σ level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio frequency and DC high voltage breakdown of high pressure helium, argon, and xenon

Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is developing a program of R&D to test radio frequency (RF) carpets for ion transport in high pressure xenon gas. This would require carpet functionality in regimes at higher pressures than have been previously reported, implying correspondingly larger electrode voltages than in existing systems. This mode of operation appears plausible for contemporary RF-carpet geometries due to the higher predicted breakdown strength of high pressure xenon relative to low pressure helium, the working medium in most existing RF carpet devices. In this paper we present the first measurements of the high voltage dielectric strength of xenon gas at high pressure and at the relevant RF frequencies for ion transport (in the 10 MHz range), as well as new DC and RF measurements of the dielectric strengths of high pressure argon and helium gases at small gap sizes. We find breakdown voltages that are compatible with stable RF carpet operation given the gas, pressure, voltage, materials and geometry of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design, construction, and commissioning of the KATRIN experiment

The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90%C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times,and present details on their respective commissioning campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS↗

Cyclotron radiation emission spectroscopy of electrons from tritium $β$ decay and 83m Kr internal conversion

Project 8 has developed a novel technique, cyclotron radiation emission spectroscopy (CRES), for direct neutrino mass measurements. A CRES-based experiment on the beta spectrum of tritium has been carried out in a small-volume apparatus. Here, we provide a detailed account of the experiment, focusing on systematic effects and analysis techniques. In a Bayesian (frequentist) analysis, we measure the tritium endpoint as ${18}$ ${553}_{—19}^{+18}$ (${18}$ ${548}_{—19}^{+19}$) eV and set upper limits of 155 (152) eV (90% C.L.) on the neutrino mass. No background events are observed beyond the endpoint in 82 days of running. We also demonstrate an energy resolution of 1.66 ± 0.19 eV in a resolution-optimized magnetic trap configuration by measuring 83m Kr 17.8-keV internal-conversion electrons. These measurements establish CRES as a low-background, high-resolution technique with the potential to advance neutrino mass sensitivity

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths

Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. In this work, we report the angular dependence of the specular reflectance in vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of an FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beta Radiation Hardness of GYGAG(Ce) Transparent Ceramic Scintillators

GYGAG(Ce) transparent ceramic garnet scintillators were irradiated with electrons from 0.5 to 2 MeV with fluences from 10 16 e – /cm 2 to 10 19 e – /cm 2 , corresponding to doses from 0.3 to 310 Gigarad. Absorption spectra were measured before and after irradiations. Light yields from alpha, beta, and gamma excitations were measured before and after irradiation and compared to preirradiation values to gain a deeper understanding of how electron irradiations can affect light yield, as well as defects generated in both the surface and bulk. Within experimental error, no degradation in light yield was observed for the electron-irradiated samples, as measured via beta or gamma excitation, with minimal degradation observed via alpha excitation. A small increase in optical absorption near the wavelength of emission was observed following the largest dose irradiation. These results suggest that GYGAG(Ce) is radiation hard to electron irradiation up to 10 19 e – /cm 2 and doses up to 310 Gigarad. Furthermore, this robustness to irradiation indicates that transparent ceramic garnets may prove useful for applications such as scintillation-based nuclear batteries by allowing for higher energy beta emitters, increased power densities, and enabling long service lifetimes.

36 MATERIALS SCIENCE↗

Data for Training and Testing Radiation Detection Algorithms in an Urban Environment

The US government routinely performs radiological response deployments to search for the presence of illicit nuclear materials (e.g., highly enriched uranium and weapons-grade plutonium) in a specified area. The deployments can be intelligence driven, in support of law enforcement, and for planned events such as WrestleMania, presidential inaugurations, or political conventions. In a typical deployment, radiation detection systems carried by human operators or mounted on vehicles move in a clearing pattern through the search area. Search teams rely on radiation detection algorithms running on these systems in real time to alert them to the presence of an illicit threat source. The detection and identification of sources is complicated by large variation of natural radiation background throughout a search area and the potential presence of localized non-threat sources such as patients undergoing treatment with medical isotopes. As a result, detection algorithms must be carefully balanced between missing real sources (false negatives) and reporting too many false alarms (false positives).The purpose of this data set is to spur innovations in detecting, identifying, and localizing nuclear materials inurban search missions.

07 ISOTOPE AND RADIATION SOURCES↗

Integrating Control Methods and Digital Twins for Advanced Nuclear Reactors

Advanced nuclear reactors offer new capabilities such as the ability to adapt to variable energy demand, operate autonomously with remote supervision, be deployable in rural locations, be compact in size, afford lower power ratings, and rely on novel techniques for increased operational safety. However, realizing these capabilities requires intelligent control systems that can track changing power demands and make autonomous decisions based on these demands. The unique aspects of advanced reactors (e.g., strict regulatory requirements, harsh operating environments, high consequences, highly coupled dynamics, evolving knowledge, and limited operating histories) directly impact the design and deployment of control systems for these reactors. The present work identifies and evaluates these aspects so as to develop a set of control system requirements to guide future research and development. To meet these requirements, a layered control system approach is proposed that integrates digital twins with different control paradigms. This work aims to demonstrate how different methods interface with enabling solutions, and to identify any gaps that need to be researched.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Horizontal Split Table Conceptual Design for Advanced Reactor Validation

Oak Ridge National Laboratory and Lawrence Livermore National Laboratory are collaborating to develop a conceptual design for a horizontal split table for use in performing critical experiments. The goal of this design effort is to provide nuclear data testing and validation capabilities for advanced reactors such as pebble-bed high-temperature gas-cooled reactors, molten salt reactors, and heat pipe microreactor, but it could also be used for the current generation of reactors. The first concept being explored for the horizontal split table, a pebble-bed design based on the HTR-10 reactor, is described in this paper. A critical configuration corresponding to a footprint of about 4.5 m 2 was determined with SCALE/KENO-VI to fit the planned dimensions of the horizontal split table. The similarity of the pebble-bed design and the HTR-10 reactor application was assessed using SCALE/TSUNAMI, and a similarity coefficient $c_k$ of 0.9982 was obtained, proving that the concept will be useful for nuclear data validation and assimilation of pebble-bed type advanced reactors. In the proposed design, the materials with the highest $k_{eff}$ sensitivity are graphite and uranium, demonstrating that particular care must be given to carbon-related cross-section data. The effect of mechanical uncertainties between the fixed and moving tables was also assessed by calculating the reactivity change caused by vertical and horizontal gaps, as well as angular and torsion offsets between the two sides of the horizontal split table concept. The highest relative changes on the concept’s reactivity were caused by angular perturbations. The same analysis process is currently being used to create a molten salt advanced reactor type horizontal split table concept based on the Molten Salt Reactor Experiment (MSRE).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Cold Moderator For Sub-Thermal Neutron Flux Enhancement at the RPI-LINAC

The importance of high-quality thermal neutron scattering kernels coupled with a lack of accurate sub-thermal total cross section data prompted researchers at Rensselaer Polytechnic Institute (RPI) to design a cold moderation system to enhance sub-thermal neutron flux (defined as flux below 5 meV), for nuclear data measurements at the RPI Gaerttner LINAC facility. Using a series of neutronic and heat transfer simulations obtained with MCNP and COMSOL, an optimized final design was produced. The final design exceeded current target sub-thermal neutron producing capabilities by a factor of 8 in the sub-thermal region and is easily configurable with existing neutron producing targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗