Electron-Beam Corkscrew Motion in an Advanced Linear Induction Accelerator

Scorpius is a multipulse linear induction accelerator (LIA) under development for flash radiography. Because it has substantially more cells than present LIAs, higher magnetic focusing fields are needed to suppress beam breakup (BBU). Therefore, it is more susceptible to corkscrew motion of the beam, which also depends on beam energy spread and focusing magnet misalignments. For energy spread and alignment tolerances expected for Scorpius, a magnetic tune designed to suppress BBU is shown to produce corkscrew motion within the range that can be controlled through the use of steering dipoles on existing LIAs. Finally, a gap-voltage modulation scheme is shown to almost completely eliminate chromatic effects such as corkscrew.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Wall Design of a Tokamak Pilot Plant Using a Monte Carlo Model for 3-D Heat Flux Deposition

We present a method for calculating the heat fluxes deposited on nonaxisymmetric tokamak first wall components, allowing for a first-of-its-kind model for power handling in the tokamak far scrape-off layer (SOL). The DIV3D Monte Carlo model features strict global power conservation and can calculate the finite cross-field plasma transport into magnetically-shadowed regions, which is significant when dealing with meter-scale shadows introduced by components such as poloidal limiters or antennas. As a case study, we apply the DIV3D model to inform the distribution of first wall poloidal limiters in an ARC-class reactor device. We demonstrate that discrete protection limiters can efficiently reduce peak heat fluxes on recessed breeder wall components in the presence of significant far-SOL plasma fluxes. By varying the toroidal periodicity and radial standoff depth of the limiters, we demonstrate one of the tradeoffs that must be considered in first wall design: more limiters provide greater protection, but at the cost of reduced breeding performance. We also present the impact that radial misalignments between limiters would have on first wall power loading.

Monte Carlo methods↗

Time Series Classification for Locating Forced Oscillation Sources

Here, this article presents a machine learning based time-series classification method for using synchrophasor measurements to locate the source of forced oscillation (FO) for fast disturbance removal. First, multivariate time series (MTS) matrices are constructed by the most informative measurements selected by sequential feature selection from each power plant. Then, the Mahalanobis matrix is trained such that the Mahalanobis distance between the MTSs from the same class (i.e., with the same FO source location) are minimized and from different classes (i.e., with different FO source locations) are maximized. This allows MTSs to be classified by classifiers with class membership corresponding to the location of each FO source. To meet the runtime requirements of online matching, class templates are constructed to reduce data size and improve matching efficiency. To account for uncertainty in identifying the exact beginning of an FO event, dynamic time warping is used to align the out-of-sync MTSs. IEEE 39bus and WECC 179bus systems are used for algorithm development and validation. Simulation results demonstrate that the algorithm meets online operation runtime requirement with high accuracy using misaligned data sets.

42 ENGINEERING↗

Optical Spectrometer With a Pulse-to-Pulse Resolution for Terahertz and mm-Wave Signals

The development of ultra-compact particle accelerators and accelerator-based high-power THz generators are some of the top priorities for research and development programs around the world. These tools require the development of accelerating structures, operating in the mm-Wave and THz range, where diagnostics are not available or are insufficient. This article presents the design of a pulse-to-pulse THz spectrometer, primarily developed for diagnostics of accelerating structures and THz radiation sources. In particular, this spectrometer can be used to detect RF pulse shortening caused by vacuum breakdown and beam misalignment in THz accelerators, as well as for bunch length monitoring and radiation source diagnostics. The spectrometer is based on a diffraction grating and is capable of covering a frequency range where RF-based breakdown measurements are not possible. We have built and tested the first prototype with different sources in a frequency range of 0.1-1.0 THz. In this article, we present the physical design, supported numerical simulations, electronics development, and test results.

47 OTHER INSTRUMENTATION↗

Testing and Assessment of EMFs and Touch Currents from 25-kW IPT System for Medium-Duty EVs

Inductive power transfer (IPT) technology has gained massive attention for electric vehicle charging due to the associated reliability, convenience, and safety. Nevertheless, the loose coupling between the transmitter and receiver generates intensive electromagnetic fields (EMFs) around the system, which may influence living objects' safety if the typical limits are exceeded. Moreover, these fields induce voltages in the vehicle body, which may lead to touch current passing through the human body when it gets in contact with two metal parts or one part and the ground. Following the international standards and recommendations, this study presents comprehensive test guidelines for the near-EMFs and touch currents from a commercial 25-kW wireless charger from Momentum Dynamics, which was installed in an electric shuttle operating at the National Renewable Energy Laboratory (NREL) campus. The paper investigates the measuring devices, test setup, test points and standard limits. The impact of the misalignments on the measurements is considered during testing. EMFs are measured in areas around and inside the shuttle and near the power supply and compared with the reference levels defined by the international standards, including ICNIRP 2010, IEEE C95.1 and ACGIH TLV 2017. Touch currents are evaluated among different metal parts and ground in comparison with the standard limits. The results show that both EMFs and touch currents comply with the standard limits. Moreover, thermal inspection for the system after installation was provided. Finally, a 5-day of operation data for the wireless charger are collected and presented.

33 ADVANCED PROPULSION SYSTEMS↗

In-Vehicle Assessment of Human Exposure to EMFs from 25-kW WPT System Based on Near-Field Analysis

Wireless power transfer (WPT) technology has the potential to be a convenient and reliable charging method for the light and heavy duty electric vehicles. However, the loosely coupling between the two sides results in strong near-electromagnetic fields (EMFs) around the system, which may have the possibility to impact human safety if the standard limits are exceeded. Therefore, comprehensive tests are necessary to ensure the electromagnetic fields are with in safe limits. Consequently, this paper presents a test methodology for the near-field from a 25 kW WPT system from Momentum Dynamics, which is installed in a heavy duty electric shuttle at the National Renewable Energy Laboratory (NREL). The paper describes in detail the measuring device, test setup and conditions. The misalignments between the two systems' sides are considered during the measurements. Test results for the regions of concern around and inside the bus are presented and compared with the reference levels defined by the international standards, including ICNIRP 2010 and IEEE C95.1. In addition, a finite-element model is developed for the wireless coupler and analyzed at the same conditions as the tests. Comparative analysis is presented between the simulated and experimental results. The measurements at the test points show adherence to the standard limits for the general public and occupational exposure.

33 ADVANCED PROPULSION SYSTEMS↗

Near-Field Radiative Heat Transfer Between Two α-MoO3 Biaxial Crystals

The near-field radiative heat transfer (NFRHT) between two semi-infinite α-MoO3 biaxial crystals is investigated numerically based on the fluctuation–dissipation theorem combined with the modified 4 × 4 transfer matrix method in this paper. In the calculations, the near-field radiative heat flux (NFRHF) along each of the crystalline directions of α-MoO3 is obtained by controlling the orientation of the biaxial crystals. The results show that much larger heat flux than that between two semi-infinite hexagonal boron nitride can be achieved in the near-field regime, and the maximum heat flux is along the [001] crystalline direction. The mechanisms for the large radiative heat flux are explained as due to existence of hyperbolic phonon polaritons (HPPs) inside α-MoO3 and excitation of hyperbolic surface phonon polaritons (HSPhPs) at the vacuum/α-MoO3 interfaces. The effect of relative rotation between the emitter and the receiver on the heat flux is also investigated. It is found that the heat flux varies significantly with the relative rotation angle. The modulation contrast can be as large as two when the heat flux is along the [010] direction. We attribute the large modulation contrast mainly to the misalignment of HSPhPs and HPPs between the emitter and the receiver. Hence, the results obtained in this work may provide a promising way for manipulating near-field radiative heat transfer between anisotropic materials.

Engineering↗

Technoeconomic Design of a Geothermal-Enabled Cold Climate Zero Energy Community

Development of a zero energy community is more costly in northern cold climates than in moderate regions. Building energy loads are higher, thanks to the colder weather, and site solar photovoltaics (PV) are less productive due to lower solar incidence and misalignment with the buildings’ energy needs (summer production, winter demands). Geothermal energy production can support a zero energy community through application of energy efficiency (demand design), geothermal production (supply design), and asset dispatch as an integrated techno-economic package. This article presents the process used to explore geothermal system integration, our findings, and technical challenges for community-scale adoption of geothermal as an electric and thermal resource. We show that under a wide range of conditions, community-scale geothermal electric power and direct-use thermal energy is economically competitive with “business-as-usual” design and construction practices for zero energy communities. Furthermore, geothermal-produced energy will be self-consumed to a much greater extent than PV, resulting in significant reductions in site energy import and export. We conclude that under appropriate conditions, community-scale geothermal can be the most economically favorable energy resource for northern-climate zero energy community developments. Ongoing geothermal research and development to improve performance and reduce costs will further enhance the value proposition for community-scale geothermal technologies. We expect that including geothermal power and thermal energy in zero energy community design can improve its cost-effectiveness and therefore enhance the benefits of zero energy in more northern climates.

15 GEOTHERMAL ENERGY↗

Additively Manufactured Compliant Hybrid Gas Thrust Bearing for Supercritical Carbon Dioxide Turbomachinery: Design and Proof of Concept Testing

The following paper presents a new type of gas lubricated thrust bearing that utilizes additive manufacturing or also known as direct metal laser melting (DMLM) to fabricate the bearing. The motivation for the new bearing concept is derived from the need for highly efficient supercritical carbon dioxide (sCO2) turbomachinery in the mega-watt power range. The paper provides a review of existing gas thrust-bearing technology, outlines the need for the new DMLM concept, and discusses proof-of-concept testing results. The new concept combines hydrostatic pressurization with individual tilting pads that are flexibly mounted using hermetic squeeze film dampers (HSFD) in the bearing-pad support. This paper describes the thrust-bearing concept and discusses the final design approach. Proof-of-concept testing in air for a 6.8 in. (173 mm) outer diameter thrust gas bearing was performed; with thrust loading, up to 1500 lbs (6.67 kN) and a thrust runner speed of 10krpm (91 m/s tip speed). The experiments were performed with a bent shaft resulting in thrust runner axial vibration magnitudes of 2.9 mils (74 μm) p-p and dynamic thrust loads of 270 lbs (1.2 kN) p-p. In addition, force deflection characteristics and stiffness coefficients of the bearing system are presented for an inlet hydrostatic pressure of 380 psi (2.62 MPa). Results at 10 krpm show that the pad support architecture was able to sustain high levels of dynamic misalignment equaling 6 times the nominal film clearance while demonstrating a unit load-carrying capacity of 55 psi (0.34 Mpa). Gas-film force deflection tests portrayed nonlinear behavior like a hardening spring, while the bearing pad support stiffness was measured to be linear and independent of gas film thickness.

Engineering↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Optically resonant subwavelength films for tamper-indicating tags and seals

We present the design, modeling and performance of a proof-of-concept tamper indicating approach that exploits newly-developed subwavelength-patterned films. These films have a nanostructure-dependent resonant optical reflection that is wavelength, angle, and polarization dependent. As such, they can be tailored to fabricate overlay transparent films for tamper indication and authentication of sensitive or controlled materials not possible with currently-known technologies. An additional advantage is that the unique optical signature is dictated by the geometry and fabrication process of the nanostructures in the film, rather than on the material used. The essential structure unit in the subwavelength resonant coating is a nanoscale Open-Ring Resonator (ORR). This building block is fabricated by coating a dielectric nanoscale template with metal to form a hemispherical shell-like structure. This curved metallic shell structure has a cross-section with an intrinsic capacitance and inductance and is thus the optical equivalent to the well-known “LC” circuit where the capacitance and inductance are determined by the nanoshell dimensions. For structures with sub 100 nm scale, this resonance occurs in the visible electromagnetic spectrum, and in the IR for larger shells. Tampering of the film would be visible though misalignment of the angular dependence of the features in the film. It is additionally possible to add in intrinsic oxidation and strain sensitive matrix materials to further complicate tamper repair and counterfeiting. Cursory standoff readout would be relatively simple using a combination of a near-infrared (or visible) LED flashlight and polarizer or passively using room lighting illumination and a dispersive detector.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Towards a new generation long trace profiler LTP-2020: optical design of pencil beam interferometry sensor

Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.

Takacs, Peter Z.↗

Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner

Treatment of small animals with radiation has in general been limited to planar fields shaped with lead blocks, complicating spatial localization of dose and treatment of deep-seated targets. In order to advance laboratory radiotherapy toward what is accomplished in the clinic, we have constructed a variable aperture collimator for use in shaping the beam of microCT scanner. This unit can image small animal subjects at high resolution, and is capable of delivering therapeutic doses in reasonable exposure times. The proposed collimator consists of two stages, each containing six trapezoidal brass blocks that move along a frame in a manner similar to a camera iris producing a hexagonal aperture of variable size. The two stages are offset by 30 deg. and adjusted for the divergence of the x-ray beam so as to produce a dodecagonal profile at isocenter. Slotted rotating driving plates are used to apply force to pins in the collimator blocks and effect collimator motion. This device has been investigated through both simulation and measurement. The collimator aperture size varied from 0 to 8.5 cm as the driving plate angle increased from 0 to 41 deg. . The torque required to adjust the collimator varied from 0.5 to 5 N{center_dot}m, increasing with increasing driving plate angle. The transmission profiles produced by the scanner at isocenter exhibited a penumbra of approximately 10% of the collimator aperture width. Misalignment between the collimator assembly and the x-ray source could be identified on the transmission images and corrected by adjustment of the collimator location. This variable aperture collimator technology is therefore a feasible and flexible solution for adjustable shaping of radiation beams for use in small animal radiotherapy as well as other applications in which beam shaping is desired.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems

The medical linear accelerator (linac) integrated with a kilovoltage (kV) flat-panel imager has been emerging as an important piece of equipment for image-guided radiation therapy. Due to the sagging of the linac head and the flexing of the robotic arms that mount the x-ray tube and flat-panel detector, geometric nonidealities generally exist in the imaging geometry no matter whether it is for the two-dimensional projection image or three-dimensional cone-beam computed tomography. Normally, the geometric parameters are established during the commissioning and incorporated in correction software in respective image formation or reconstruction. A prudent use of an on-board imaging system necessitates a routine surveillance of the geometric accuracy of the system like the position of the x-ray source, imager position and orientation, isocenter, rotation trajectory, and source-to-imager distance. Here we describe a purposely built phantom and a data analysis software for monitoring these important parameters of the system in an efficient and automated way. The developed tool works equally well for the megavoltage (MV) electronic portal imaging device and hence allows us to measure the coincidence of the isocenters of the MV and kV beams of the linac. This QA tool can detect an angular uncertainty of 0.1 deg. of the x-ray source. For spatial uncertainties, such as the source position, the imager position, or the kV/MV isocenter misalignment, the demonstrated accuracy of this tool was better than 1.6 mm. The developed tool provides us with a simple, robust, and objective way to probe and monitor the geometric status of an imaging system in a fully automatic process and facilitate routine QA workflow in a clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detection condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In addition, the new method can be generally applied to calibrating other types of detectors that use the similar dual-ended readout to acquire the radiation interaction position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiotherapy margin design with particular consideration of high curvature CTVs

In applying 3D conformal radiation therapy to a tumor clinical target volume (CTV), a margin is added around the CTV to account for any sources of error in the application of treatment which may result in misalignment between the CTV and the dose distribution actually delivered. The volume enclosed within the CTV plus the margin is known as the PTV, or planning target volume. The larger the errors are anticipated to be, the wider the margin will need to be to accommodate those errors. Based on the approach of van Herk et al. [''The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy,'' Int. J. Radiat. Oncol. Biol., Phys. 47(4), 1121-1135 (2000)] this paper develops the mathematical theory behind the calculation of the margin width required to ensure that the entire CTV receives sufficiently high dose with sufficiently high probability. The margin recipe developed not only considers the magnitude of the errors but also includes a term to adjust for curved CTV surfaces. In doing so, the accuracy of the margin recipe is enhanced yet remains mathematically concise enough to be readily implemented in the clinical setting. The results are particularly relevant for clinical situations in which the uncertainties in treatment are large relative to the size of the CTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of an irradiation method with lateral modulation of SOBP width using a cone-type filter for carbon ion beams

Passive irradiation methods deliver an extra dose to normal tissues upstream of the target tumor, while in dynamic irradiation methods, interplay effects between dynamic beam delivery and target motion induced by breathing or respiration distort the dose distributions. To solve the problems of those two irradiation methods, the authors have developed a new method that laterally modulates the spread-out Bragg peak (SOBP) width. By reducing scanning in the depth direction, they expect to reduce the interplay effects. They have examined this new irradiation method experimentally. In this system, they used a cone-type filter that consisted of 400 cones in a grid of 20 cones by 20 cones. There were five kinds of cones with different SOBP widths arranged on the frame two dimensionally to realize lateral SOBP modulation. To reduce the number of steps of cones, they used a wheel-type filter to make minipeaks. The scanning intensity was modulated for each SOBP width with a pair of scanning magnets. In this experiment, a stepwise dose distribution and spherical dose distribution of 60 mm in diameter were formed. The nonflatness of the stepwise dose distribution was 5.7% and that of the spherical dose distribution was 3.8%. A 2 mm misalignment of the cone-type filter resulted in a nonflatness of more than 5%. Lateral SOBP modulation with a cone-type filter and a scanned carbon ion beam successfully formed conformal dose distribution with nonflatness of 3.8% for the spherical case. The cone-type filter had to be set to within 1 mm accuracy to maintain nonflatness within 5%. This method will be useful to treat targets moving during breathing and targets in proximity to important organs.

61 RADIATION PROTECTION AND DOSIMETRY↗