An Intercomparison of Tropospheric Ozone Retrievals Derived from Two Aura Instruments and Measurements in Western North America in 2006

Two recently developed methods for quantifying tropospheric ozone abundances based on Aura data, the Trajectory‐enhanced Tropospheric Ozone Residual (TTOR) and an assimilation of Aura data into Goddard Earth Observing System Version 4 (ASM), are compared to ozone measurements from ozonesonde data collected in April-May 2006 during the INTEX Ozonesonde Network Study 2006 (IONS‐06) campaign. Both techniques use Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) observations. Statistics on column ozone amounts for both products are presented. In general, the assimilation compares better to sonde integrated ozone to 200 hPa (28.6% difference for TTOR versus 2.7% difference for ASM), and both products are biased low. To better characterize the performance of ASM, ozone profiles based on the assimilation are compared to those from ozonesondes. We noted slight negative biases in the lower troposphere, and slight positive biases in the upper troposphere/lower stratosphere (UT/ LS), where we observed the greatest variability. Case studies were used to further understand ASM performance. We examine one case from 17 April 2006 at Bratt's Lake, Saskatchewan, where geopotential height gradients appear to be related to an underestimation in the ASM in the UT/LS region. A second case, from 21 April 2006 at Trinidad Head, California, is a situation where the overprediction of ozone in the UT/LS region does not appear to be due to current dynamic conditions but seems to be related to uncertainty in the flow pattern and large differences in MLS observations upstream.

UTLS↗

Distributed coupling and multi-frequency microwave accelerators

A microwave circuit for a linear accelerator has multiple metallic cell sections, a pair of distribution waveguide manifolds, and a sequence of feed arms connecting the manifolds to the cell sections. The distribution waveguide manifolds are connected to the cell sections so that alternating pairs of cell sections are connected to opposite distribution waveguide manifolds. The distribution waveguide manifolds have concave modifications of their walls opposite the feed arms, and the feed arms have portions of two distinct widths. In some embodiments, the distribution waveguide manifolds are connected to the cell sections by two different types of junctions adapted to allow two frequency operation. The microwave circuit may be manufactured by making two quasi-identical parts, and joining the two parts to form the microwave circuit, thereby allowing for many manufacturing techniques including electron beam welding, and thereby allowing the use of un-annealled copper alloys, and hence greater tolerance to high gradient operation.

43 PARTICLE ACCELERATORS↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗

Coherent radar measurement of ocean currents from geostationary orbit

A coherent HF radar system developed by Barrick has successfully measured ocean surface currents near shore. This innovative system, called CODAR, can map the current vector for coastal areas as large as 10,000 sq km. CODAR's range is limited owing to the strong attenuation suffered by HF ground waves. An alternate technique was proposed by Schuler, in which the cross-product power spectrum of two (different frequency) microwave signals is processed. The frequency of the resonant peak corresponds close by to the Doppler shift of an ocean gravity wave traveling toward the radar at the phase velocity, v(sub p). The slight difference between the frequency of the measured resonant delta K peak and the Doppler frequency shift caused by the motion of the gravity wave is attributed to be the current velocity in the pointing direction of the radar. The Microwave Remote Sensing Laboratory (MIRSL) has considered the feasibility of using this technique to measure ocean surface currents from geostationary satellite platforms. Problems are discussed that must be overcome if a satellite current measurement system is to be realized. MIRSL research activities that address some of these problem areas are discussed. Current measurements are presented that were made using a specially-designed C-Band, step-frequency delta K radar. These measurements suggest that progress is being achieved in detecting ocean surface current motion for a wide variety of ocean surface conditions.

Mcintosh, R. E.↗

Non-contact, non-destructive, quantitative probing of interfacial trap sites for charge carrier transport at semiconductor-insulator boundary

The density of traps at semiconductor–insulator interfaces was successfully estimated using microwave dielectric loss spectroscopy with model thin-film organic field-effect transistors. The non-contact, non-destructive analysis technique is referred to as field-induced time-resolved microwave conductivity (FI-TRMC) at interfaces. Kinetic traces of FI-TRMC transients clearly distinguished the mobile charge carriers at the interfaces from the immobile charges trapped at defects, allowing both the mobility of charge carriers and the number density of trap sites to be determined at the semiconductor-insulator interfaces. The number density of defects at the interface between evaporated pentacene on a poly(methylmethacrylate) insulating layer was determined to be 10{sup 12 }cm{sup −2}, and the hole mobility was up to 6.5 cm{sup 2} V{sup −1} s{sup −1} after filling the defects with trapped carriers. The FI-TRMC at interfaces technique has the potential to provide rapid screening for the assessment of interfacial electronic states in a variety of semiconductor devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing the edge states of Chern insulators using microwave impedance microscopy

Microwave impedance microscopy (MIM) has been utilized to directly visualize topological edge states in many quantum materials. While the microwave response for conventional metals and insulators can be accurately quantified using simple lumped-element circuits, whose applicability to more exotic quantum systems remain limited. In this work, we present a general theoretical framework of the MIM response of arbitrary quantum materials. Applying it to topological edge states in a Chern insulator predicts an enhanced MIM response at the crystal boundaries due to collective edge magnetoplasmon (EMP) excitations. The unique resonance frequency of these plasmonic modes allows one to disentangle the signatures of topological versus trivial edge states. To benchmark our analytical predictions, we experimentally probe the MIM response of quantum anomalous Hall edge states in a Cr-doped (Bi,Sb) 2 Te 3 topological insulator and perform numerical simulations using a classical formulation of the EMP modes based on this realistic tip-sample geometry, both of which yield results consistent with our theoretical picture. Here we also show how the technique of MIM can be used to quantitatively extract the topological invariant of a Chern insulator and shed light on the microscopic nature of dissipation along the crystal boundaries.

36 MATERIALS SCIENCE↗

The present situation and forecasts of semiconductor elements performance within the microwave range, 1970-1985

The present situation and possible developments over the period 1970-1985 for active semiconductor elements in the microwave range are outlined. After a short historical survey of FT techniques, the following are discussed: Generation, power amplification, amplification of small signals, frequency conversion, detection, electronic signal control and integrated microwave circuits.

Peterson, B.↗

Swept frequency technique for dispersion measurement of microstrip lines

Microstrip lines used in microwave integrated circuits are dispersive. Because a microstrip line is an open structure, the dispersion can not be derived with pure TEM, TE, or TM mode analysis. Dispersion analysis has commonly been done using a spectral domain approach, and dispersion measurement has been made with high Q microstrip ring resonators. Since the dispersion of a microstrip line is fully characterized by the frequency dependent phase velocity of the line, dispersion measurement of microstrip lines requires the measurement of the line wavelength as a function of frequency. In this paper, a swept frequency technique for dispersion measurement is described. The measurement was made using an automatic network analyzer with the microstrip line terminated in a short circuit. Experimental data for two microstrip lines on 10 and 30 mil Cuflon substrates were recorded over a frequency range of 2 to 20 GHz. Agreement with theoretical results computed by the spectral domain approach is good. Possible sources of error for the discrepancy are discussed.

Lee, R. Q.↗

Swept frequency technique for dispersion measurement of microstrip lines

Microstrip lines used in microwave integrated circuits are dispersive. Because a microstrip line is an open structure, the dispersion can not be derived with pure TEM, TE, or TM mode analysis. Dispersion analysis has commonly been done using a spectral domain approach, and dispersion measurement has been made with high Q microstrip ring resonators. Since the dispersion of a microstrip line is fully characterized by the frequency dependent phase velocity of the line, dispersion measurement of microstrip lines requires the measurement of the line wavelength as a function of frequency. In this paper, a swept frequency technique for dispersion measurement is described.

Lee, Richard Q.↗

Alternative Metal Fuel Casting Techniques: Advanced Fuel Cycle Initiative

This report will summarize current and future work to be done on microwave and continuous casting systems. These systems were chosen for evaluation based on a Metal Fuel Casting Develop review conducted by a body of independent experts in the field of casting and metal fuel fabrication. Technique evaluation will be based on work done by Microwave Synergy, Inc. to produce a non-wetting mold and crucible assembly and several castings using a Ti-Cu alloy. Continuous casting will be evaluated through a report written by Wagstaff Applied Technologies. The report will detail a conceptual design for a laboratory scale continuous casting system, the system design will be support by thermal and fluid flow modeling.

INL/EXT-09-16871↗

Analysis of satellite altimeter signal characteristics and investigation of sea-truth data requirements

Results are presented of analysis of satellite signal characteristics as influenced by ocean surface roughness and an investigation of sea truth data requirements. The first subject treated is that of postflight waveform reconstruction for the Skylab S-193 radar altimeter. Sea state estimation accuracies are derived based on analytical and hybrid computer simulation techniques. An analysis of near-normal incidence, microwave backscattering from the ocean's surface is accomplished in order to obtain the minimum sea truth data necessary for good agreement between theoretical and experimental scattering results. Sea state bias is examined from the point of view of designing an experiment which will lead to a resolution of the problem. A discussion is given of some deficiencies which were found in the theory underlying the Stilwell technique for spectral measurements.

Source record↗

Systems analysis for DSN microwave antenna holography

Proposed systems for Deep Space Network (DSN) microwave antenna holography are analyzed. Microwave holography, as applied to antennas, is a technique which utilizes the Fourier Transform relation between the complex far-field radiation pattern of an antenna and the complex aperture field distribution to provide a methodology for the analysis and evaluation of antenna performance. Resulting aperture phase and amplitude distribution data are used to precisely characterize various crucial performance parameters, including panel alignment, subreflector position, antenna aperture illumination, directivity at various frequencies, and gravity deformation. Microwave holographic analysis provides diagnostic capacity as well as being a powerful tool for evaluating antenna design specifications and their corresponding theoretical models.

Rochblatt, D. J.↗

Intratumoral Injection of Hypertonic Glucose in Treating Refractory Pneumothorax Caused by Microwave Ablation: a Preliminary Study

Purpose: The purpose of this technical report is to describe the technique of intratumoral injection of hypertonic glucose combined with low-negative pressure drainage to treat refractory pneumothorax (RP) after microwave ablation (MWA) of lung tumors. Materials and Methods: Between September 2016 and May 2018, four patients who developed RP after MWA of peripheral lung cancer were managed by a combined method, including intratumoral injection of hypertonic glucose and catheter drainage under low-negative pressure. Blood gas values were recorded and compared before the treatment and one-week posttreatment. All patients were followed up for at least one month to monitor the possible recurrence of pneumothorax by chest CT. Results: All patients were successfully treated. One patient received the intratumoral injection of hypertonic glucose twice, while the remaining three patients received a single injection. The technical success rate was 100%. Dyspnea related to RP was significantly relieved in all patients, and PaO{sub 2} and SaO{sub 2} values were higher than those measured before treatment. No patient suffered a recurrence of pneumothorax during the follow-up. Conclusion: The combined method of intratumoral injection of hypertonic glucose and continuous catheter drainage under low-negative pressure might be an effective method to manage RP caused by MWA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Propofol Compared to Midazolam Sedation and to General Anesthesia for Percutaneous Microwave Ablation in Patients with Hepatic Malignancies: A Single-Center Comparative Analysis of Three Historical Cohorts

Purpose: In percutaneous ablation procedures, periprocedural pain, unrest and respiratory concerns can be detrimental to achieve a safe and efficacious ablation and impair treatment outcome. This study aimed to compare the association between anesthetic technique and local disease control in patients undergoing percutaneous microwave ablation (MWA) of colorectal liver metastases (CRLM) and hepatocellular carcinoma (HCC). Materials and Methods: This IRB-exempted single-center comparative, retrospective analysis of three cohorts analyzed 90 patients treated for hepatic malignancies from January 2013 until September 2018. The local tumor progression-free survival (LTPFS), safety and periprocedural pain perception were assessed using univariate and multivariate Cox proportional hazard regression analyses to correct for potential confounders. Results: In 114 procedures (22 general anesthesia; 32 midazolam; 60 propofol), 171 liver tumors (136 CRLM; 35 HCC) were treated with percutaneous MWA. Propofol and general anesthesia were superior to midazolam/fentanyl sedation regarding LTPFS (4/94 [4.3%] vs. 19/42 [45.2%] vs. 2/35 [5.7%]; P < 0.001, respectively). Local tumor progression rate was 14.6% (25/171). Eighteen tumors (72.0%) were retreated by ablation. Of them, 14 (78%) were previously treated with midazolam. Propofol versus midazolam (P < 0.001), general anesthesia versus midazolam (P = 0.016), direct postprocedural visual analog pain score above 5 (P = 0.050) and more than one tumor per procedure (P = 0.045) were predictors for LTPFS. Multivariate analysis revealed that propofol versus midazolam (HR 7.94 [95% CI 0.04–0.39; P < 0.001]) and general anesthesia versus midazolam (HR 6.33 [95% CI 0.04–0.69; P = 0.014]) were associated with LTPFS. Pain during and directly after treatment was significantly worse in patients who received midazolam sedation (P < 0.001). Conclusions: Compared to propofol and general anesthesia, midazolam/fentanyl sedation was associated with an increased periprocedural perception of pain and lower local tumor progression-free survival. To reduce the number of repeat procedures required to eradicate hepatic malignancies, general anesthesia and propofol sedation should be favored over midazolam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ESTAR - A synthetic aperture microwave radiometer for measuring soil moisture

The measurement of soil moisture from space requires putting relatively large microwave antennas in orbit. Aperture synthesis, an interferometric technique for reducing the antenna aperture needed in space, offers the potential for a practical means of meeting these requirements. An aircraft prototype, electronically steered thinned array L-band radiometer (ESTAR), has been built to develop this concept and to demonstrate its suitability for the measurement of soil moisture. Recent flights over the Walnut Gulch Watershed in Arizona show good agreement with ground truth and with measurements with the Pushbroom Microwave Radiometer (PBMR).

Le Vine, D. M.↗

Inspection of Spray on Foam Insulation (SOFI) Using Microwave and Millimeter Wave Synthetic Aperture Focusing and Holography

The Space Shuttle Columbia s catastrophic failure is thought to have been caused by a dislodged piece of external tank spray on foam insulation (SOFI) striking and significantly damaging the left wing of the orbiter, which may have been due to a flawed section of SOFI. Microwave and millimeter wave nondestructive evaluation (NDE) methods have shown great potential detecting anomalies in SOFI such as small air voids using a horn and lens in a (real) focused configuration. Synthetic focusing methods may also be used to detect air voids in SOFI and may additionally offer the ability to locate the defect in three dimensions. To this end, two different methods were investigated; namely, frequency domain synthetic aperture focusing technique (FD-SAFT) and wide-band microwave holography. To illustrate the performance of these methods they were applied to two different SOFI samples. The results of these investigations demonstrate the capabilities of these methods for SOFI inspection.

Case, J. T.↗