Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Investigating lab-scaled offshore wind aerodynamic testing failure and developing solutions for early anomaly detections

As offshore wind systems become more complex, the risk of human error or equipment malfunction increases during experimental testing. This study investigates a lab-scale incident involving a 1 : 50 scale 5 MW wind turbine, where a generator failure led to rotor overspeed and a blade–tower strike. To improve early fault detection, we propose a data-driven method based on multivariate long short-term memory (LSTM) models. High-frequency measurements are projected onto principal components, and anomalies are identified using reconstruction error and its time derivative. Two models are trained on different healthy datasets and tested using single- and multi-principal component (1PC and MPC) variations. Results show that combining both error and error derivative improves detection accuracy. The 1PC model detects faults faster, has a higher recall rate, and achieves a 43 % improvement in anomaly detection accuracy, while the MPC model yields higher precision. This approach provides a simple and effective tool for early anomaly detection in lab-scale experiments, helping to reduce the risk of future failures during the testing of new technologies.

17 WIND ENERGY↗

Idealized simulation study of the relationship of disdrometer sampling statistics with the precision of precipitation rate measurement

Due to the discretized nature of rain, the measurement of a continuous precipitation rate by disdrometers is subject to statistical sampling errors. Here, Monte Carlo simulations are employed to obtain the precision of rain detection and rate as a function of disdrometer collection area and compared with World Meteorological Organization guidelines for a 1 min sample interval and 95 % probability. To meet these requirements, simulations suggest that measurements of light rain with rain rates R ≤ 0.50 mm h-1 require a collection area of at least 6 cm × 6 cm, and for R = 1 mm h -1 , the minimum collection area is 13 cm × 13 cm. For R = 0.01 mm h -1 , a collection area of 2 cm × 2 cm is sufficient to detect a single drop. Simulations are compared with field measurements using a new hotplate device, the Differential Emissivity Imaging Disdrometer. The field results suggest an even larger plate may be required to meet the stated accuracy, likely in part due to non-Poissonian hydrometeor clustering.

54 ENVIRONMENTAL SCIENCES↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamical logical qubits in the Bacon-Shor code

The Bacon-Shor code is a quantum error correcting subsystem code composed of weight-2 check operators that admits a single logical qubit, and has distance 𝑑 on a 𝑑×𝑑 square lattice. We show that when viewed as a Floquet code, by choosing an appropriate measurement schedule of the check operators, it can additionally host several dynamical logical qubits. Specifically, we identify a period-4 measurement schedule of the check operators that preserves logical information between the instantaneous stabilizer groups. Such a schedule not only measures the usual stabilizers of the Bacon-Shor code, but also measures and promotes gauge operators of the parent subsystem code to additional temporary stabilizers that protect the dynamical logical qubits against errors. We show that the code distance of these Floquet-Bacon-Shor codes scales as Θ⁢(𝑑/√𝑘) on an 𝑛=𝑑×𝑑 lattice with 𝑘 dynamical logical qubits, along with the logical qubit of the parent subsystem code. Unlike the usual Bacon-Shor code, the Floquet-Bacon-Shor code family introduced here can therefore saturate the subsystem bound 𝑘⁢𝑑=𝑂⁡(𝑛). Moreover, several errors are shown to be self-corrected purely by the measurement schedule itself. This work provides insights into the design space for dynamical codes and expands the known approaches for constructing Floquet codes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deblending galaxies with variational autoencoders: A joint multiband, multi-instrument approach

ABSTRACT Blending of galaxies has a major contribution in the systematic error budget of weak-lensing studies, affecting photometric and shape measurements, particularly for ground-based, deep, photometric galaxy surveys, such as the Rubin Observatory Legacy Survey of Space and Time (LSST). Existing deblenders mostly rely on analytic modelling of galaxy profiles and suffer from the lack of flexible yet accurate models. We propose to use generative models based on deep neural networks, namely variational autoencoders (VAE), to learn probabilistic models directly from data. We train a VAE on images of centred, isolated galaxies, which we reuse, as a prior, in a second VAE-like neural network in charge of deblending galaxies. We train our networks on simulated images including six LSST bandpass filters and the visible and near-infrared bands of the Euclid satellite, as our method naturally generalizes to multiple bands and can incorporate data from multiple instruments. We obtain median reconstruction errors on ellipticities and r-band magnitude between ±0.01 and ±0.05, respectively, in most cases, and ellipticity multiplicative bias of 1.6 per cent for blended objects in the optimal configuration. We also study the impact of decentring and prove the method to be robust. This method only requires the approximate centre of each target galaxy, but no assumptions about the number of surrounding objects, pointing to an iterative detection/deblending procedure we leave for future work. Finally, we discuss future challenges about training on real data and obtain encouraging results when applying transfer learning.

Arcelin, Bastien↗

A Time-Varying Model for Predicting Formaldehyde Emission Rates in Homes

Recent studies have succeeded in relating emissions of various volatile organic compounds to material mass diffusion transfer using detailed empirical characteristics of each of the individual emitting materials. While significant, the resulting models are often scenario specific and/or require a host of individual component parameters to estimate emission rates. This study developed an approach to estimate aggregated emissions rates based on a wide number of field measurements. We used a multi-parameter regression model based on previous mass transfer models to predict formaldehyde emission rate for a whole dwelling using field-measured, time-resolved formaldehyde concentrations, air exchange rates, and indoor environmental parameters in 63 California single-family houses built between 2011 and 2017. The resulting model provides time-varying formaldehyde emission rates, normalized by floor area, for each study home, assuming a well-mixed mass balance transport model of the home, and a well-mixed layer transport model of indoor surfaces. The surface layer model asserts an equilibrium concentration within the surface layer of the emitted materials that is a function of temperature and RH; the dwelling ventilation rate serves as a surrogate for indoor concentration. We also developed a more generic emission model that is suitable for broad prediction of emission for a population of buildings. This model is also based on measurements aggregated from 27 homes from the same study. We showed that errors in predicting household formaldehyde concentrations using this approach were substantially less than those using a traditional constant emission rate model, despite requiring less unique building information.

54 ENVIRONMENTAL SCIENCES↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Tomographic Sparse View Selection Using the View Covariance Loss

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

Lin, Jingsong [Purdue University]↗

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progress at RML is improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Surrogate Modeling For Efficiently Accurately and Conservatively Estimating Measures of Risk

We present a surrogate modeling framework for conservatively estimating measures of risk from limited realizations of an expensive physical experiment or computational simulation. We adopt a probabilistic description of risk that assigns probabilities to consequences associated with an event and use risk measures, which combine objective evidence with the subjective values of decision makers, to quantify anticipated outcomes. Given a set of samples, we construct a surrogate model that produces estimates of risk measures that are always greater than their empirical estimates obtained from the training data. These surrogate models not only limit over-confidence in reliability and safety assessments, but produce estimates of risk measures that converge much faster to the true value than purely sample-based estimates. We first detail the construction of conservative surrogate models that can be tailored to the specific risk preferences of the stakeholder and then present an approach, based upon stochastic orders, for constructing surrogate models that are conservative with respect to families of risk measures. The surrogate models introduce a bias that allows them to conservatively estimate the target risk measures. We provide theoretical results that show that this bias decays at the same rate as the L 2 error in the surrogate model. Our numerical examples confirm that risk-aware surrogate models do indeed over-estimate the target risk measures while converging at the expected rate.

97 MATHEMATICS AND COMPUTING↗

Trigonometric Parallaxes of Two T Dwarfs With Keck and ShaneAO Astrometry

We present trigonometric parallax and proper motion measurements for two T-type brown dwarfs. We derive our measurements from infrared laser guide star adaptive optics observations spanning five years from the ShaneAO/SHARCS and NIRC2/medium-cam instruments on the Shane and Keck telescopes, respectively. To improve our astrometric precision, we measure and apply a distortion correction to our fields for both instruments. We also transform the Keck and ShaneAO astrometric reference frames onto the ICRS using five-parameter parallax and proper motion solutions for background reference stars from Gaia DR2. Fitting for parallax and proper motion, we measure parallaxes of 73.5 ± 9.2 mas and 70.1 ± 6.7 mas for WISEJ19010703+47181688 (WISE1901) and WISEJ21543294+59421370 (WISE2154), respectively. We utilize Monte Carlo methods to estimate the error in our sparse field methods, taking into account overfitting and differential atmospheric refraction. Comparing to previous measurements in the literature, all of our parallax and proper motion values fall within 2σ of the published measurements, and 4 of 6 measurements are within 1σ. These data are among the first parallax measurements of these T dwarfs and serve as precise measurements for calibrating stellar formation models. These two objects are the first results of an ongoing survey of T dwarfs with Keck/NIRC2 and the Shane Adaptive Optics system at Lick Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Robust measurement of microbial reduction of graphene oxide nanoparticles using image analysis

ABSTRACT Shewanella oneidensis ( S. oneidensis ) has the capacity to reduce electron acceptors within a medium and is thus used frequently in microbial fuel generation, pollutant breakdown, and nanoparticle fabrication. Microbial fuel setups, however, often require costly or labor-intensive components, thus making optimization of their performance onerous. For rapid optimization of setup conditions, a model reduction assay can be employed to allow simultaneous, large-scale experiments at lower cost and effort. Since S. oneidensis uses different extracellular electron transfer pathways depending on the electron acceptor, it is essential to use a reduction assay that mirrors the pathways employed in the microbial fuel system. For microbial fuel setups that use nanoparticles to stimulate electron transfer, reduction of graphene oxide provides a more accurate model than other commonly used assays as it is a bulk material that forms flocculates in solutions with a large ionic component. However, graphene oxide flocculates can interfere with traditional absorbance-based measurement techniques. This study introduces a novel image analysis method for quantifying graphene oxide reduction, showing improved performance and statistical accuracy over traditional methods. A comparative analysis shows that the image analysis method produces smaller errors between replicates and reveals more statistically significant differences between samples than traditional plate reader measurements under conditions causing graphene oxide flocculation. Image analysis can also detect reduction activity at earlier time points due to its use of larger solution volumes, enhancing color detection. These improvements in accuracy make image analysis a promising method for optimizing microbial fuel cells that use nanoparticles or bulk substrates. IMPORTANCE Shewanella oneidensis ( S. oneidensis ) is widely used in reduction processes such as microbial fuel generation due to its capacity to reduce electron acceptors. Often, these setups are labor-intensive to operate and require days to produce results, so use of a model assay would reduce the time and expenses needed for optimization. Our research developed a novel digital analysis method for analysis of graphene oxide flocculates that may be utilized as a model assay for reduction platforms featuring nanoparticles. Use of this model reduction assay will enable rapid optimization and drive improvements in the microbial fuel generation sector.

Bennett, Danielle T. (ORCID:0009000188748827)↗

Applying Multi-Frequency AC LOCO for Finding Sextupole Errors

A fast and precise technique of multi-frequency AC LOCO has been developed and tested for finding the sextupole alignment and field-offset errors at NSLS-II. This technique is based on sine-wave beam excitation simultaneously at multiple frequencies via different fast correctors. The unique combination of the fast speed and high measurement accuracy opens the door for two different types of potential applications: finding the sextupole alignment and field-offset errors. Beam excitation via fast correctors results in the elimination of the systematic error caused by the hysteresis effect. Systematic errors of the sextupole alignment caused by orbit drift and power supply calibration are also eliminated because the measurement takes only two minutes and does not depend on the current-to-field conversion of sextupole magnets. Furthermore, the simulation studies indicate that multi-frequency AC LOCO together with an orbit bump bigger than 0.5 mm can be applied to measure the relative field offset of a sextupole magnet with a precision better than 10%. The measurement technique is described and the results of two proof-of-principle experiments carried out at NSLS-II are presented.

43 PARTICLE ACCELERATORS↗

Leveraging Qubit Loss Detection in Fault-Tolerant Quantum Algorithms

Qubit loss errors constitute a dominant source of noise in many quantum hardware systems, particularly in neutral-atom quantum computers. We develop a theoretical framework to effectively detect and correct loss errors in logical algorithms and leverage such loss information in decoding. Considering general quantum error correction codes and logical circuits, we introduce a delayed-erasure decoder for experimentally motivated error models which leverages information from delayed loss detection to accurately correct loss errors, even when the precise moment of the error is unknown. Using this decoder, we identify strategies for detecting and correcting loss errors based on the logical circuit structure. For deep circuits prior to logical measurement, we explore methods to integrate loss detection into syndrome extraction with minimal overhead, identifying optimal strategies depending on the qubit loss fraction in the noise and hardware capabilities. In contrast, we find that many key algorithmic subroutines involve frequent gate teleportation, shortening the circuit depth before logical measurement and naturally replacing qubits with no additional experimental overhead. We simulate this setting using a toy model algorithm for small-angle synthesis and find a significant performance improvement as the loss fraction increases. These results provide a path forward for advancing large-scale fault-tolerant quantum computation in systems with loss error detection.

atoms↗

A Combined Computer Vision and Deep Learning Approach for Rapid Drone-Based Optical Characterization of Parabolic Troughs

Optical accuracy is a primary driver of parabolic trough concentrating solar power (CSP) plant performance, but can be damaged by wind loads, gravity, error during installation, and regular plant operation. Collecting and analyzing optical measurements over an entire operating parabolic trough plant is difficult, given the large scale of typical installations. Distant Observer, a software tool developed at the National Renewable Energy Laboratory, uses images of the absorber tube reflected in the collector mirror to measure both surface slope in the parabolic mirror and offset of the absorber tube from the ideal focal point. This technology has been adapted for fast data collection using low-cost commercial drones, but until recently still required substantial human labor to process large amounts of data. A new method leveraging advanced deep learning and computer vision tools can drastically reduce the time required to process images. This new method addresses the primary analysis bottleneck, identifying featureless, reflective mirror corner points to a high degree of accuracy. Recent work has shown promising results using computer vision methods. The combined deep learning and computer vision approach presented here proved highly effective and has the potential to further automate data collection and analysis, making the tool more robust. The method presented in this paper automatically identified 74.3% of mirror corners within 2 pixels of their manually marked counterparts and 91.9% within 3 pixels. This level of accuracy is sufficient for practical Distant Observer analysis within a target uncertainty. A commercial drone collected video of over 100 parabolic trough modules at an operating CSP plant to demonstrate the deep learning and computer vision method's usefulness in processing large amounts of data. These troughs were successfully analyzed using Distant Observer, paired with the new deep learning and computer vision algorithm, and can provide plant operators and trough designers with valuable insight about plant performance, operating strategies, and plant-wide optical error trends.

computer vision↗

Stratospheric temperature measurements from nanosatellite stellar occultation observations of refractive bending

Abstract. Stellar occultation observations from space can probe the stratosphere and mesosphere at a fine vertical scale around the globe. Unlike other measurement techniques like radiosondes and aircraft, stellar occultation has the potential to observe the atmosphere above 30 km, and unlike radio occultation, stellar occultation probes fine-scale phenomena with potential to observe atmospheric turbulence. We imaged the refractive bending angle of a star centroid for a series of occultations by the atmosphere. Atmospheric refractivity, density, and then temperature are retrieved from the bending observations with the Abel transformation and Edlén's law, the hydrostatic equation, and the ideal gas law. The retrieval technique is applied to data collected by two nanosatellites operated by Terran Orbital. Measurements were primarily taken by the GEOStare SV2 mission, with a dedicated imaging telescope, supplemented with images captured by spacecraft bus sensors, namely the star trackers on other Terran Orbital missions. The bending angle noise floor is 10 and 30 arcsec for the star tracker and GEOStare SV2 data, respectively. The most significant sources of uncertainty are due to centroiding errors due to the fairly low-resolution stellar images and telescope pointing knowledge derived from noisy satellite attitude sensors. The former mainly affects the star tracker data, while the latter limits the GEOStare SV2 accuracy, with both providing low vertical resolution. This translates to a temperature profile retrieval up to roughly 20 km for both star tracker and GEOStare SV2 datasets. In preparation of an upcoming 2023 mission designed to correct these deficiencies, SOHIP, we simulated bending angle measurements with varying magnitudes of error. The expected maximum altitude of retrieved temperature is 41 km on average for these simulated measurements with a noise floor of 0.39 arcsec. Our work highlights the capabilities of stellar occultation observations from nanosatellites for atmospheric sounding. Future work will investigate high-frequency observations of atmospheric gravity waves and turbulence, mitigating the major uncertainties observed in these datasets.

54 ENVIRONMENTAL SCIENCES↗

Development and cross‐validation of a circumference‐based predictive equation to estimate body fat in an active population

Abstract Objective The U.S. Army uses sex‐specific circumference‐based prediction equations to estimate percent body fat (%BF) to evaluate adherence to body composition standards. The equations are periodically evaluated to ensure that they continue to accurately assess %BF in a diverse population. The objective of this study was to develop and validate alternative field expedient equations that may improve upon the current Army Regulation (AR) body fat (%BF) equations. Methods Body size and composition were evaluated in a representatively sampled cohort of 1904 active‐duty Soldiers (1261 Males, 643 Females), using dual‐energy X‐ray absorptiometry (%BF DXA ), and circumferences obtained with 3D imaging and manual measurements. Sex stratified linear prediction equations for %BF were constructed using internal cross validation with %BF DXA as the criterion measure. Prediction equations were evaluated for accuracy and precision using root mean squared error, bias, and intraclass correlations. Equations were externally validated in a convenient sample of 1073 Soldiers. Results Three new equations were developed using one to three circumference sites. The predictive values of waist, abdomen, hip circumference, weight and height were evaluated. Changing from a 3‐site model to a 1‐site model had minimal impact on measurements of model accuracy and performance. Male‐specific equations demonstrated larger gains in accuracy, whereas female‐specific equations resulted in minor improvements in accuracy compared to existing AR equations. Equations performed similarly in the second external validation cohort. Conclusions The equations developed improved upon the current AR equation while demonstrating robust and consistent results within an external population. The 1‐site waist circumference‐based equation utilized the abdominal measurement, which aligns with associated obesity related health outcomes. This could be used to identify individuals at risk for negative health outcomes for earlier intervention.

Taylor, Kathryn M.↗