Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “limit loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Rudder/Fin Seals Investigated for the X-38 Re-Entry Vehicle

NASA is developing the X-38 vehicle that will demonstrate the technologies required for a potential crew return vehicle for the International Space Station. This vehicle would serve both as an ambulance for medical emergencies and as an evacuation vehicle for the space station. Control surfaces on the X-38 (body flaps and rudder/fin assemblies) require high temperature seals to limit hot gas ingestion and the transfer of heat to underlying low temperature structures. Working with the NASA Johnson Space Center, the Seals Team at the NASA Glenn Research Center completed a series of tests to further characterize baseline seal designs for the rudder/fin interfaces of the X-38. The structures of the rudder/fin assembly and its associated seals are shown in the the preceding illustration. Tests performed at Glenn indicated that exposure of the seals in a compressed state at simulated seal re-entry temperatures resulted in a large permanent set and loss of seal resiliency. This could be of concern because the seals are required to maintain contact with the sealing surfaces while the vehicle goes through the maximum re-entry heating cycle to prevent hot gases from leaking past the seals and damaging interior low-temperature structures. To simulate conditions in which the seals may become unloaded during use, such as when they take on a large permanent set, Glenn researchers performed room temperature flow and compression tests to determine seal flow rates, resiliency, and unit loads under minimal loads. Flow rates through an unloaded (i.e., 0-percent compression) double seal arrangement were twice those of a double seal compressed to the 20-percent design compression level. These flow rates are being used in thermal analyses to predict the effect of flow through the seals on over-all seal temperatures. Compression test results showed that seal unit loads and contact pressures were below the limits that Johnson had set as goals for the seals. In the rudder/fin seal location, the seals are in contact with shuttle thermal tiles and are moved across the tiles as the rudder is rotated during re-entry. Low seal unit loads and contact pressures are required to limit the loads on these tiles and minimize any damage that the seals could cause. A series of tests were performed on these seals in NASA Ames Research Center's arc jet facility. The arc jet facility approximates relevant thermal environments that a seal or other structure would be subjected to during extreme heating conditions such as those experienced during space vehicle re-entry. Eleven tests were completed, including one test in which no seal was installed in the gap to examine the flow of heat down into the gap. The seal was compressed between stationary insulation tiles and a movable elevon that was rotated during the test to deflect the arc jet exhaust into the seal gap. Peak seal temperatures as high as 2000 F were reached during the 5-min tests. Results of these tests indicate satisfactory performance of the seal for single-use (e.g., X-38) applications. The results of these tests were shared with the NASA Johnson Space Center and are being used to validate aerothermostructural analysis codes that predict seal temperatures under these conditions. The tests performed at Glenn have provided valuable information to Johnson about the performance of the seals that they are considering using in the rudder/fin location of the X-38 vehicle. Glenn and Johnson are currently defining what additional work needs to be done to develop the final rudder/fin seal design for the X-38 vehicle.

Dunlap, Patrick H., Jr.↗

Cold Crucible Induction Melter (CCIM) Demonstration Using a Representative Savannah River Site Sludge Simulant On the Large-Size Pilot Platform at the CEA-Marcoule

The cold-crucible induction melter technology (CCIM) is considered worldwide for industrial implementation to overcome the current limits of high level waste vitrification technologies and to answer future challenges such as: new or difficult sludge compositions, need for improving waste loading, need for high temperatures, and corrosive effluents. More particularly, this technology is being considered for implementation at the US DOE Savannah River site to increase the rate of waste processing while reducing the number of HLW canisters to be produced through increased waste loading and improved waste throughput. A collaborative program involving AREVA, CEA (French Atomic Energy Commission), SRNL (Savannah River National Laboratory) and WSRC (Washington Savannah River Company) has thus been initiated in 2007 to demonstrate vitrification with waste loadings on the order of 50% (versus the current DWPF waste loading of about 35%) with a PUREX-type waste composition (high Fe{sub 2}O{sub 3} composition), and to perform two pilot-scale runs on the large size platform equipped with a 650 mm diameter CCIM at the CEA Marcoule. The objectives of the demonstrations were 1) to show the feasibility of processing a representative SRS sludge surrogate using continuous slurry feeding, 2) to produce a glass that would meet the acceptance specifications with an increased waste loading when compared to what is presently achieved at the DWPF, and 3) achieve improved waste throughputs. This presentation describes the platform and the very encouraging results obtained from the demonstration performed at temperatures, specific throughputs and waste loadings that overcome current DWPF limits. Results from the initial exploratory run and second demonstration run include 1) production of a glass product that achieved the targeted glass composition that was more durable than the standard Environmental Assessment (EA) glass, 2) successful slurry feeding of the CCIM, and 3) promising waste processing rates (at 1250 deg. C and 1300 deg. C melt pool temperature) that could result in processing of the Savannah River HLW faster than could be currently achieved with the existing Joule Heated melter in DWPF. In conclusion, this joint effort conducted by CEA, AREVA, SRNL and WSRC led to very encouraging results, demonstrating waste throughputs 44 % that of the DWPF ceramic melter throughput in a 650 mm CCIM melter for the same waste type with a Sludge Batch 3 PUREX-type waste feed flux of 150 L/h/m{sup 2} demonstrated at 1250 deg. C. The very high waste loading (above 52%) allows reducing the amount of glass to be produced by about 27% to treat the same amount of waste when compared to previous DWPF operation for this specific type of feed, since 27 % less glass is needed to immobilize the same amount of waste. It was also demonstrated, for this type of feed, an unusual behavior with regard to nepheline formation, which would require further evaluation for future applications. The product from the baseline demonstration run, with a waste loading of at least 52%, displayed a very good quality. Stabilized operation close to the maximum throughput was demonstrated. Cesium volatility was apparently between 7 and 12 % (based on glass analysis); however this value is only preliminary. This demonstration also allowed the CEA to better understand the SRS slurry feed behavior and to propose adaptations to the platform for any future demonstrations using this type of feed. Finally, use of a large diameter CCIM ({approx}1 meter) may allow faster processing of the SRS HLW than can be achieved with the current DWPF melter. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vibration and local instability of thermally stressed plates

The vibration and buckling of a double wedge square cantilever plate has been investigated. It is shown that the free vibration modes, which occur at Delta T ref = 0, transition into the buckled modes which occur at Delta T ref = Delta T ref-cr for the respective mode. Delta T ref-cr for a particular mode is defined as the magnitude of thermal load at which the frequency of the particular mode vanishes. The analysis yields the same number of buckling eigenvalues and buckling modes as there are vibration eigenvalues and vibration modes. Gradual application of the load in the analysis permits the change in each vibration frequency of interest and its associated mode to be followed up to the load at which the frequency of the mode becomes zero. This constitutes the limit of linear theory. As the load is increased, the thin edges of the plate begin to deform during vibration. This local deformation, which begins in the vibration mode, is shown to transition into the phenomena of local edge buckling at Delta T ref-cr for the mode.

Bailey, C. D.↗

Shuttle car loading system

A system is described for loading newly mined material such as coal, into a shuttle car, at a location near the mine face where there is only a limited height available for a loading system. The system includes a storage bin having several telescoping bin sections and a shuttle car having a bottom wall that can move under the bin. With the bin in an extended position and filled with coal the bin sections can be telescoped to allow the coal to drop out of the bin sections and into the shuttle car, to quickly load the car. The bin sections can then be extended, so they can be slowly filled with more while waiting another shuttle car.

Collins, E. R., Jr.↗

Observation of Beam Loading in a Laser-Plasma Accelerator

Beam loading is the phenomenon which limits the charge and the beam quality in plasma based accelerators. An experimental study conducted with a laser-plasma accelerator is presented. Beam loading manifests itself through the decrease of the beam energy, the reduction of dark current, and the increase of the energy spread for large beam charge. 3D PIC simulations are compared to the experimental results and confirm the effects of beam loading. It is found that, in our experimental conditions, the trapped electron beams generate decelerating fields on the order of 1 (GV/m)/pC and that beam loading effects are optimized for trapped charges of about 20 pC.

43 PARTICLE ACCELERATORS↗

Microgrids for Service Restoration to Critical Load in a Resilient Distribution System

icrogrids can act as emergency sources to serve critical loads when utility power is unavailable. This paper proposes a resiliency-based methodology that uses microgrids to restore critical loads on distribution feeders after a major disaster. Due to limited capacity of distributed generators (DGs) within microgrids, dynamic performance of the DGs during the restoration process becomes essential. In this paper, the stability of microgrids, limits on frequency deviation, and limits on transient voltage and current of DGs are incorporated as constraints of the critical load restoration problem. The limits on the amount of generation resources within microgrids are also considered. By introducing the concepts of restoration tree and load group, restoration of critical loads is transformed into a maximum coverage problem, which is a linear integer program (LIP). The restoration paths and actions are determined for critical loads by solving the LIP. A 4-feeder, 1069-bus unbalanced test system with four microgrids is utilized to demonstrate the effectiveness of the proposed method. The method is applied to the distribution system in Pullman, WA, resulting in a strategy that uses generators on the Washington State University campus to restore service to the Hospital and City Hall in Pullman.

Xu, Yin (ORCID:0000000209459024)↗

Buckling analysis of curved composite sandwich panels subjected to inplane loadings

Composite sandwich structures are being considered for primary structure in aircraft such as subsonic and high speed civil transports. The response of sandwich structures must be understood and predictable to use such structures effectively. Buckling is one of the most important response mechanisms of sandwich structures. A simple buckling analysis is derived for sandwich structures. This analysis is limited to flat, rectangular sandwich panels loaded by uniaxial compression (N(sub x)) and having simply supported edges. In most aerospace applications, however, the structure's geometry, boundary conditions, and loading are usually very complex. Thus, a general capability for analyzing the buckling behavior of sandwich structures is needed. The present paper describes and evaluates an improved buckling analysis for cylindrically curved composite sandwich panels. This analysis includes orthotropic facesheets and first-order transverse shearing effects. Both simple support and clamped boundary conditions are also included in the analysis. The panels can be subjected to linearly varying normal loads N(sub x) and N(sub y) in addition to a constant shear load N(sub xy). The analysis is based on the modified Donnell's equations for shallow shells. The governing equations are solved by direct application of Galerkin's method. The accuracy of the present analysis is verified by comparing results with those obtained from finite element analysis for a variety of geometries, loads, and boundary conditions. The limitations of the present analysis are investigated, in particular those related to the shallow shell assumptions in the governing equations. Finally, the computational efficiency of the present analysis is considered.

Cruz, Juan R.↗

Examination of lead concentrations in new decorative enamel paints in four countries with different histories of activity in lead paint regulation

Paints with high lead concentrations (ppm) continue to be sold around the world in many developing countries and those with economies in transition representing a major preventable environmental health hazard that is being increased as the economies expand and paint consumption is increasing. Prior lead paint testing had been performed in Brazil and India and these countries were selected to examine the impact of a new regulatory limit in Brazil and the impact of efforts of non-governmental organizations and others to stop the use of lead compounds in manufacturing paints. Armenia and Kazakhstan, in Central Asia, were selected because no information on lead concentration in those regions was available, no regulatory activities were evident and non-governmental organizations in the IPEN network were available to participate. Another objective of this research was to evaluate the lead loading (µg/cm{sup 2}) limit determined by X-Ray Fluorescence (XRF) for areas on toys that are too small to obtain a sample of sufficient size for laboratory analysis. The lead concentrations in more than three-fourths of the paints from Armenia and Kazakhstan exceeded 90 ppm, the limit in the United States, and 600 ppm, the limit in Brazil. The percentages were about one-half as high in Brazil and India. The average concentration in paints purchased in Armenia, 25,000 ppm, is among the highest that has been previously reported, that in Kazakhstan, 15,700 ppm, and India, 16,600, about median. The average concentration in Brazil, 5600 ppm, is among the lowest observed. Paints in Brazil that contained an average of 36,000 ppm before the regulatory limit became effective were below detection (<9 ppm) in samples collected in the current study. The lack of any apparent public monitoring of paint lead content as part of regulatory enforcement makes it difficult to determine whether the regulation was a major factor contributing to the decline in lead use in these paints. Using data from the current study and those available from other studies 24 of 28 paints from major brands in India decreased from high concentrations to 90 ppm or lower. Since lead concentrations in golden yellow paints from these brands were found to decrease to ≤90 ppm, it is possible that all 28 of these paints now contain ≤90 ppm since yellow paints usually have the highest lead concentrations. Other brands in Brazil and India that have been analyzed only one time had lead concentrations up to 59,000 ppm and 134,000 ppm, respectively. Less than one-third of the paints had notations on their labels with information about lead content and these were sometimes inaccurate. The label from one brand indicating “no added lead” contained paint with 134,000 ppm lead, the highest found in this study. Three percent (3 of 98) of the paints with surface lead loading that did not exceed 2 µg/cm{sup 2}, the limit established by the Consumer Product Safety Improvement Act for small areas on toys, contained greater than 90 ppm lead and thus were false negatives. Of the new paint samples that contained ≤600 ppm, 88% contained ≤90 ppm. Of the samples that contained ≤90 ppm, 97% contained ≤45 ppm and 92% contained ≤15 ppm. Based on these data it appears to be technically feasible to manufacture paints containing ≤90 ppm and in many cases to produce paints that have lead concentrations that do not exceed 15 ppm. - Highlights: • Brazilian paints with high lead (avg. 36,000 ppm) contained <9 ppm after regulation. • Lead in major Indian paint brands decreased to low levels by efforts of NGOs/others. • Most paints with lead ≤600 ppm also are ≤90 ppm and many also ≤15 ppm. • At the CPSIA limit of 2 µg Pb/cm{sup 2} for small areas on toys, 3% exceeded 90 ppm lead. • Most paint brands in Armenia and Kazakhstan based/manufactured outside the country.

54 ENVIRONMENTAL SCIENCES↗

Neural Net Safety Monitor Design

The National Aeronautics and Space Administration (NASA) at the Dryden Flight Research Center (DFRC) has been conducting flight-test research using an F-15 aircraft (figure 1). This aircraft has been specially modified to interface a neural net (NN) controller as part of a single-string Airborne Research Test System (ARTS) computer with the existing quad-redundant flight control system (FCC) shown in figure 2. The NN commands are passed to FCC channels 2 and 4 and are cross channel data linked (CCDL) to the other computers as shown. Numerous types of fault-detection monitors exist in the FCC when the NN mode is engaged; these monitors would cause an automatic disengagement of the NN in the event of a triggering fault. Unfortunately, these monitors still may not prevent a possible NN hard-over command from coming through to the control laws. Therefore, an additional and unique safety monitor was designed for a single-string source that allows authority at maximum actuator rates but protects the pilot and structural loads against excessive g-limits in the case of a NN hard-over command input. This additional monitor resides in the FCCs and is executed before the control laws are computed. This presentation describes a floating limiter (FL) concept1 that was developed and successfully test-flown for this program (figure 3). The FL computes the rate of change of the NN commands that are input to the FCC from the ARTS. A window is created with upper and lower boundaries, which is constantly floating and trying to stay centered as the NN command rates are changing. The limiter works by only allowing the window to move at a much slower rate than those of the NN commands. Anywhere within the window, however, full rates are allowed. If a rate persists in one direction, it will eventually hit the boundary and be rate-limited to the floating limiter rate. When this happens, a persistent counter begins and after a limit is reached, a NN disengage command is generated. The tunable metrics for the FL are (1) window size, (2) drift rate, and (3) persistence counter. Ultimate range limits are also included in case the NN command should drift slowly to a limit value that would cause the FL to be defeated. The FL has proven to work as intended. Both high-g transients and excessive structural loads are controlled with NN hard-over commands. This presentation discusses the FL design features and presents test cases. Simulation runs are included to illustrate the dramatic improvement made to the control of NN hard-over effects. A mission control room display from a flight playback is presented to illustrate the neural net fault display representation. The FL is very adaptable to various requirements and is independent of flight condition. It should be considered as a cost-effective safety monitor to control single-string inputs in general.

Larson, Richard R.↗

Implementation of an Adaptive Controller System from Concept to Flight Test

The National Aeronautics and Space Administration (NASA) at the Dryden Flight Research Center (DFRC) has been conducting flight-test research using an F-15 aircraft (figure 1). This aircraft has been specially modified to interface a neural net (NN) controller as part of a single-string Airborne Research Test System (ARTS) computer with the existing quad-redundant flight control system (FCC) shown in figure 2. The NN commands are passed to FCC channels 2 and 4 and are cross channel data linked (CCDL) to the other computers as shown. Numerous types of fault-detection monitors exist in the FCC when the NN mode is engaged; these monitors would cause an automatic disengagement of the NN in the event of a triggering fault. Unfortunately, these monitors still may not prevent a possible NN hard-over command from coming through to the control laws. Therefore, an additional and unique safety monitor was designed for a single-string source that allows authority at maximum actuator rates but protects the pilot and structural loads against excessive g-limits in the case of a NN hard-over command input. This additional monitor resides in the FCCs and is executed before the control laws are computed. This presentation describes a "floating limiter" (FL) concept that was developed and successfully test-flown for this program (figure 3). The FL computes the rate of change of the NN commands that are input to the FCC from the ARTS. A window is created with upper and lower boundaries, which is constantly "floating" and trying to stay centered as the NN command rates are changing. The limiter works by only allowing the window to move at a much slower rate than those of the NN commands. Anywhere within the window, however, full rates are allowed. If a rate persists in one direction, it will eventually "hit" the boundary and be rate-limited to the floating limiter rate. When this happens, a persistent counter begins and after a limit is reached, a NN disengage command is generated. The tunable metrics for the FL are (1) window size, (2) drift rate, and (3) persistence counter. Ultimate range limits are also included in case the NN command should drift slowly to a limit value that would cause the FL to be defeated. The FL has proven to work as intended. Both high-g transients and excessive structural loads are controlled with NN hard-over commands. This presentation discusses the FL design features and presents test cases. Simulation runs are included to illustrate the dramatic improvement made to the control of NN hard-over effects. A mission control room display from a flight playback is presented to illustrate the neural net fault display representation. The FL is very adaptable to various requirements and is independent of flight condition. It should be considered as a cost-effective safety monitor to control single-string inputs in general.

Larson, Richard R.↗

Preliminary performance of a low loading high tip speed fan stage

Limited data indicates the feasibility of designing fan stages for operation with weak oblique shocks in the rotor blade tip region. A 1600 ft/sec rotor tip speed fan indicated an overall efficiency of 0.846 at a pressure ratio of 1.51 even though the rotor blades had incurred damage in the leading edge tip region prior to obtaining the design speed performance. After the test it was observed that a number of the rotor blade mid-span dampers had failed, subsequently damaging a number of rotor blades in the leading edge tip region.

Bailey, E. E.↗

Power Quality and Load Capacity Evaluations of an Electric Vehicle for Multi-Robot System Applications

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

Electric vehicle↗

IEEE SusTech 2025 Presentation

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6\% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

42 - ENGINEERING↗

A high resolution IR/visible imaging system for the W7-X limiter

A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator and was operated during Operational Period 1.1 to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344 × 784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024 × 1024 pixel Allied Vision Technologies Prosilica GX1050 color camera. Both achieve sub-millimeter resolution on the 161 mm wide, inertially cooled, segmented graphite tiles. The IR and visible cameras are controlled via optical fibers over full Camera Link and dual GigE Ethernet (2 Gbit/s data rates) interfaces, respectively. While they are mounted outside the cryostat at a distance of 3.2 m from the limiter, they are close to a large magnetic trim coil and require soft iron shielding. We have taken IR data at 125 Hz to 1.25 kHz frame rates and seen that surface temperature increases in excess of 350 °C, especially on leading edges or defect hot spots. The IR camera sees heat-load stripe patterns on the limiter and has been used to infer limiter power fluxes (∼1–4.5 MW/m{sup 2}), during the ECRH heating phase. IR images have also been used calorimetrically between shots to measure equilibrated bulk tile temperature, and hence tile energy inputs (in the range of 30 kJ/tile with 0.6 MW, 6 s heating pulses). Small UFO’s can be seen and tracked by the FLIR camera in some discharges. The calibrated visible color camera (100 Hz frame rate) has also been equipped with narrow band C-III and H-alpha filters, to compare with other diagnostics, and is used for absolute particle flux determination from the limiter surface. Sometimes, but not always, hot-spots in the IR are also seen to be bright in C-III light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Floating Wind Turbine Control Optimization

We present a framework for optimizing the control parameters of floating offshore wind turbines (FOWTs). The framework combines aeroelastic simulations with a systems engineering model and control software. In an example of the optimization framework, we minimize tower damage equivalent loading with generator speed constraints. We also study the effect of thrust-limiting control and quantify the trade off between fatigue loading and energy capture using a set of optimal controller designs. Finally, we optimize the controller of four different FOWT models and compare their dynamic responses. Additional details and other use cases for the framework are presented, which can optimize different control problems and evaluate FOWT designs.

controls↗

Microgrid Integration with High Performance Computing Systems for Microreactor Operation

Multiple nuclear microreactor concepts are currently being developed across several sizes and fuel types with high performance computing (HPC) systems anticipated to be end-users of the power. Nuclear microreactors are small in size, portable, produce less than 10 MW electric, operate autonomously, and have a refueling interval of as many as 10 years. However, their load-follow is also generally limited to 10%/minute or worse whereas the power variance in HPC systems easily exceeds this constraint under normal operations. This study explores an approach that requires no load-follow from the microreactor but integrates the HPC system with a microgrid built from commercial-off-the-shelf components. Three typical HPC architectures are explored in the context of microgrid operation in this study. Components of power quality and transient response are empirically measured for five different HPC load-follow response levels using a self-contained mobile datacenter connected to the microgrid capable of integration with a nuclear microreactor.

microgrids↗

Vehicle-to-Grid Automatic Load Sharing with Driver Preference in Micro-Grids

Integration of Electrical Vehicles (EVs) with power grid not only brings new challenges for load management, but also opportunities for distributed storage and generation. This paper comprehensively models and analyzes distributed Vehicle-to-Grid (V2G) for automatic load sharing with driver preference. In a micro-grid with limited communications, V2G EVs need to decide load sharing based on their own power and voltage profile. A droop based controller taking into account driver preference is proposed in this paper to address the distributed control of EVs. Simulations are designed for three fundamental V2G automatic load sharing scenarios that include all system dynamics of such applications. Simulation results demonstrate that active power sharing is achieved proportionally among V2G EVs with consideration of driver preference. In additional, the results also verify the system stability and reactive power sharing analysis in system modelling, which sheds light on large scale V2G automatic load sharing in more complicated cases.

Wang, Yubo↗

Space Launch System: SLS Real Time Rollout Monitoring for MPCV

The NASA Space Launch System (SLS) rocket, Orion spacecraft, and Mobile Launcher (ML) are transported to Pad 39B from the Vehicle Assembly Building on a large, tracked vehicle known as the Crawler Transporter (CT). The CT is a holdover from the Apollo and Space Shuttle programs but has been extensively upgraded to accommodate the SLS. The Dynamic Rollout Test (DRT) on March 17, 2022 marked the first full rollout of the SLS and ML. Analysis indicated that loads and vibrations would be well below design limits, but out of an abundance of caution it was decided to monitor the response in real time during the rollout to assure that loads remained within predicted limits. This first rollout was outfitted with extensive test instrumentation such as accelerometers, pressure sensors, and strain gauges. This instrumentation remained in place following the integrated vehicle modal test and was being used for additional Operational Modal Analysis (OMA) during the rollout in addition to the real-time monitoring. This presentation discusses the specific loads and accelerations monitored during the rollout, how and why those responses were chosen, and how the system was implemented. Finally, a post-rollout loads reconstruction is used to assess the process and the analysis tools used for the rollout analysis.

SLS↗