Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Probing Millisecond Pulsar Emission Geometry Using Light Curves From the Fermi Large Area Telescope

An interesting new high-energy pulsar sub-population is emerging following early discoveries of gamma-ray millisecond pulsars (MSPs) by the Fermi Large Area Telescope (LAT). We present results from 3D emission modeling, including the Special Relativistic effects of aberration and time-of-flight delays and also rotational sweepback of 13-field lines, in the geometric context of polar cap (PC), slot gap (SG), outer gap (OG), and two-pole caustic (TPC) pulsar models. In contrast to the general belief that these very old, rapidly-rotating neutron stars (NSs) should have largely pair-starved magnetospheres due to the absence of significant pair production, we find that most of the light curves are best fit by SG and OG models, which indicates the presence of narrow accelerating gaps limited by robust pair production -- even in these pulsars with very low spin-down luminosities. The gamma-ray pulse shapes and relative phase lags with respect to the radio pulses point to high-altitude emission being dominant for all geometries. We also find exclusive differentiation of the current gamma-ray MSP population into two MSP sub-classes: light curve shapes and lags across wavebands impose either pair-starved PC (PSPC) or SG / OG-type geometries. In the first case, the radio pulse has a small lag with respect to the single gamma-ray pulse, while the (first) gamma-ray peak usually trails the radio by a large phase offset in the latter case. Finally, we find that the flux correction factor as a function of magnetic inclination and observer angles is typically of order unity for all models. Our calculation of light curves and flux correction factor f(_, _, P) for the case of MSPs is therefore complementary to the "ATLAS paper" of Watters et al. for younger pulsars.

Venter, Christo↗

Measuring Liquid Drops In Gas Flow

Nonintrusive optical technique enables measurement of drops of water ingested through aircraft-engine nacelle. Drops photographed by light of laser beam directed across nacelle inlet. Beam shaped by beam expander and slit into sheet 9 mm thick. Exposure time only 10 ns- length of laser pulse, and drop motion therefore frozen in each of series of photographs. Fluorescent dye added to water improves edge definition of photographic images of drops; scattered laser light and its interference effects filtered out and only light at fluorescence wavelength photographed. Technique used in research on ingestion of water from heavy rain or wheel spray, but adapts to any droplet-laden gas stream.

Parikh, Pradip G.↗

Self-absorption and Phonon Pulse Shape Discrimination in Scintillating Bolometers

In this work, we show that self-absorption of photons in scintillating bolometers can differentiate phonon pulse shapes between α (or nuclear recoil) and β/γ signals. This enables phonon pulse shape discrimination for particle identification. We establish a detector signal model that includes self-absorption and compare the simulated phonon pulse shapes with previously reported experimental results. The model predicts increase in pulse shape difference at higher self-absorption. Based on this result, we propose a new design of scintillating bolometers using 4π light reflectors for maximized self-absorption and only a single phonon readout, instead of light detectors that are typically employed for particle discrimination in scintillating bolometers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-Pulse Multi-Point Multi-Component Interferometric Rayleigh Scattering Velocimeter

A simultaneous multi-point, multi-component velocimeter using interferometric detection of the Doppler shift of Rayleigh, Mie, and Rayleigh-Brillouin scattered light in supersonic flow is described. The system uses up to three sets of collection optics and one beam combiner for the reference laser light to form a single collimated beam. The planar Fabry-Perot interferometer used in the imaging mode for frequency detection preserves the spatial distribution of the signal reasonably well. Single-pulse multi-points measurements of up to two orthogonal and one non-orthogonal components of velocity in a Mach 2 free jet were performed to demonstrate the technique. The average velocity measurements show a close agreement with the CFD calculations using the VULCAN code.

Bivolaru, Daniel↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deciphering Photoinduced Catalytic Reaction Mechanisms in Natural and Artificial Photosynthetic Systems on Multiple Temporal and Spatial Scales Using X-ray Probes

Utilization of renewable energies for catalytically generating value-added chemicals is highly desirable in this era of rising energy demands and climate change impacts. Artificial photosynthetic systems or photocatalysts utilize light to convert abundant CO 2 , H 2 O, and O 2 to fuels, such as carbohydrates and hydrogen, thus converting light energy to storable chemical resources. Here, the emergence of intense X-ray pulses from synchrotrons, ultrafast X-ray pulses from X-ray free electron lasers, and table-top laser-driven sources over the past decades opens new frontiers in deciphering photoinduced catalytic reaction mechanisms on the multiple temporal and spatial scales. Operando X-ray spectroscopic methods offer a new set of electronic transitions in probing the oxidation states, coordinating geometry, and spin states of the metal catalytic center and photosensitizers with unprecedented energy and time resolution. Operando X-ray scattering methods enable previously elusive reaction steps to be characterized on different length scales and time scales. The methodological progress and their application examples collected in this review will offer a glimpse into the accomplishments and current state in deciphering reaction mechanisms for both natural and synthetic systems. Looking forward, there are still many challenges and opportunities at the frontier of catalytic research that will require further advancement of the characterization techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Detection in Impulsive Low-Frequency Raman Imaging Using Shaped Probe Pulses

Impulsive stimulated Raman scattering (ISRS) using a single short femtosecond pump pulse to excite molecular vibrations offers an elegant pump-probe approach to perform vibrational imaging below 200 cm –1 . One shortcoming of ISRS is its inability to offer vibrational selectivity as all the vibrational bonds whose frequencies lie within the short pump-pulse bandwidth are excited. To date, several coherent control techniques have been explored to address this issue and selectively excite a specific molecular vibration by shaping the pump pulse. There has not been any systematic work that reports an analogous shaping of the probe pulse to implement preferential detection. In this work, we focus on vibrational imaging and report vibrational selective detection by shaping the probe pulse in time. Here, we demonstrate numerically and experimentally two pulse-shaping strategies with one functioning as a vibrational notch filter and the other functioning as a vibrational low-pass filter. This enables fast (25 μs/pixel) and selective hyperspectral imaging in the low-frequency regime (< 200 cm –1 ).

74 ATOMIC AND MOLECULAR PHYSICS↗

Dephasingless Laser Wakefield Acceleration

Laser wakefield accelerators (LWFAs) produce significantly high gradients enabling compact accelerators and radiation sources, but face design limitations, such as dephasing, occurring when trapped electrons outrun the accelerating phase of the wakefield. In this report we combine spherical aberration with a novel cylindrically symmetric echelon optic to spatiotemporally structure an ultra-short, high-intensity laser pulse that can overcome dephasing by propagating at any velocity over any distance. The ponderomotive force of the spatiotemporally shaped pulse can drive a wakefield with a phase velocity equal to the speed of light in vacuum, preventing trapped electrons from outrunning the wake. Simulations in the linear regime and scaling laws in the bubble regime illustrate that this dephasingless LWFA can accelerate electrons to high energies in much shorter distances than a traditional LWFA—a single 4.5 m stage can accelerate electrons to TeV energies without the need for guiding structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonuniform Flow Dynamics Probed by Nanosecond X-Ray Speckle Visibility Spectroscopy

We report observations of nanosecond nonuniform colloidal dynamics in a free flowing liquid jet using ultrafast x-ray speckle visibility spectroscopy. Utilizing a nanosecond double-bunch mode, the Linac Coherent Light Source free electron laser produced pairs of femtosecond coherent hard x-ray pulses. By exploring anisotropy in the visibility of summed speckle patterns which relates to the correlation functions, we evaluate not only the average particle flow rate in a colloidal nanoparticle jet, but also the nonuniform flow field within. The methodology presented here establishes the foundation for the study of nano- and atomic-scale inhomogeneous fluctuations in complex matter using x-ray free electron laser sources.

47 OTHER INSTRUMENTATION↗

An optical sensor for the drag-free satellite

An optical sensor for drag-free satellites is described. It is based on using fluorescent re-emission from the proof mass excited by a pulsed ultraviolet source, a technique that separates the frequencies of the excited and excitant light fluxes. A theoretical analysis of the performance and linearity of the sensor was verified by the results on a laboratory prototype. The sensor provided a measure of the position of a 4 cm radius proof mass in a 10 cm cavity to an accuracy of 1 mm. Null drift and thermal gradients caused errors less than 0.05 mm.

De Hoff, R. L.↗

HEAO 1 observations of the X-ray pulsar 4U 1626-67

Results are reported for an observation of the 7-s pulsar 4U 1626-67 with the A-2 experiment on HEAO 1. The phase-averaged X-ray spectrum between 0.7 and 60 keV is complex, as are the constituent spectra, which change radically as a function of pulse phase. Included in this spectral change is the sudden appearance and subsequent decay of a continuum or emission feature with a mean energy of 19 keV, which contains about one-half the power in this spectral range. Pulse-timing results include a new determination of the pulse period and a factor of 8 reduction in the upper limit for the light travel time for orbital periods between 1 and 7 hours. These findings are discussed and compared with the general nature of pulsar spectra.

Pravdo, S. H.↗

The role of manipulator characteristics in selecting the ideal effective vehicle

A structural model of the human pilot is introduced and discussed. The model is used to provide a rationale for certain nonlinear pilot control behavior such as stick pulsing and serves as a framework for studying aspects of motor skill development. In light of the theoretical background provided by the model, some past empirical pilot response phenomena are analyzed and shown to be attributable to manipulator or control stick characteristics. In particular, some recent problems associated with pilot/vehicle performance in glideslope tracking in short takeoff and landing (STOL) aircraft are analyzed. The apparent contribution of the cockpit manipulator (throttle) characteristics to these problems are outlined and a solution proposed and evaluated in both simulation and flight test.

Hess, R. A.↗

Operation of a microchannel plate counting system in a mass spectrometer

A multiplier detector system has been developed as part of a mass spectrometer in an ion counting mode. During its operation ions striking a microchannel plate release pulses of electrons which are accelerated to a phosphor layer. The resulting flash of light is carried by a fiber-optic bundle to a photodiode array. The detector simultaneously counts ions throughout a mass spectrum covering more than 30 amu. It extends the mass spectrometer's operation toward low count rates for trace gas analysis. Each mass peak can be independently measured at count rates between 0.1 and 1000 counts/s. Higher rates on a few peaks do not blind the entire detector. The detector's capabilities have been demonstrated by measuring Kr and Xe isotopes in air at natural abundances. The mass spectrometer, detector, and readout electronics are sufficiently compact to permit use in a balloon-borne experiment.

Murphy, D. M.↗

Narrow circumstellar emission lines in SN 1987A

Low and high dispersion short wavelength prime (SWP) spectra of SN 1987A show that the supernova's progenitor was in a post red giant branch stage of evolution at the time of its demise in February 1987. The development of narrow high temperature emission lines of N 5, N 4, N 3, C 3, He 2 and O 3 were followed since May 1987. Observations through April 1990 are presented. The lines are interpreted as arising in a low density gas surrounding the supernova which was photoionized by the extreme UV pulse at shock breakout. In this picture, their temporal evolution is determined primarily by light travel time effects and recombination. Comparison of models of circumstellar environment with the International Ultraviolet Explorer (IUE) observations are discussed.

Sonneborn, George↗

Time-Resolved Measurements in Optoelectronic Microbioanalysis

A report presents discussion of time-resolved measurements in optoelectronic microbioanalysis. Proposed microbioanalytical laboratory-on-a-chip devices for detection of microbes and toxic chemicals would include optoelectronic sensors and associated electronic circuits that would look for fluorescence or phosphorescence signatures of multiple hazardous biomolecules in order to detect which ones were present in a given situation. The emphasis in the instant report is on gating an active-pixel sensor in the time domain, instead of filtering light in the wavelength domain, to prevent the sensor from responding to a laser pulse used to excite fluorescence or phosphorescence while enabling the sensor to respond to the decaying fluorescence or phosphorescence signal that follows the laser pulse. The active-pixel sensor would be turned on after the laser pulse and would be used to either integrate the fluorescence or phosphorescence signal over several lifetimes and many excitation pulses or else take time-resolved measurements of the fluorescence or phosphorescence. The report also discusses issues of multiplexing and of using time-resolved measurements of fluorophores with known different fluorescence lifetimes to distinguish among them.

Bearman, Gregory↗

Sources of Primary Electrons in Nanosecond Pulsed Breakdown in Water (Final Technical Report)

Electrical breakdown of liquid dielectrics under ns or sub-ns pulsed electric field has been studied extensively in the last decade. Summarized in [7], this relatively young research area makes significant contributions to the theories of liquid breakdown by introducing a new mechanism (electrostrictive cavitation) that is unique at the ns timescale. It is also fundamentally important to plasma sources for biomedical applications and insulation of pulsed power equipment. For water in particular, the understanding of the mechanisms and processes of ns/sub-ns breakdown also sheds new light on cavitation studies, one of the most exciting areas of modern fluid mechanics. The objective of this collaborative research with PCRF was to construct a complete picture of the physical mechanisms and processes at the initial phase of electrical breakdown in liquid dielectrics under nanosecond (ns) pulsed inhomogeneous fields. The research funded by the initial award DE‐ SC0021182 aimed to address the sources of primary electrons in ns breakdown in water, which led to one journal publication and multiple conference presentations. The PI also gave presentations to the PPPL/PCRF audience twice, one in October 2020 and the other during the 2021 PCRF Annual Meeting

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Holographic flow visualization within a rotating compressor blade row

Rapid double-pulsed holographic techniques were used to visualize the shock configurations in the tip region of a lightly loaded, high tip speed fan stage. The holograms showed the passage shock emanating from the blade leading edge, a moderately strong conical shock originating at the intersection of the part span shroud leading edge and the blade suction surface, and a second conical shock originating at the intersection of the part span shroud and the blade pressure surface. Due to a limited viewing angle, the bow waves upstream of the rotor could not be observed, and only limited details of the trailing edge shocks were obtained. Reasonable details of the shock patterns were obtained from holograms which were made without extensive rig modifications. Results indicate that larger viewing windows and and holographic plates would permit a wider viewing angle and give much more coverage of the regions of interest. Also, shorter time delay for double-pulsed holograms is also desirable, and would minimize blade movement and give clearer holograms.

Benser, W. A.↗

Laser Light Scattering Diagnostic for Measurement of Flow Velocity in Vicinity of Propagating Shock Waves

A laser light scattering diagnostic for measurement of dynamic flow velocity at a point is described. The instrument is being developed for use in the study of propagating shock waves and detonation waves in pulse detonation engines under development at the NASA Glenn Research Center (GRC). The approach uses a Fabry-Perot interferometer to measure the Doppler shift of laser light scattered from small (submicron) particles in the flow. The high-speed detection system required to resolve the transient response as a shock wave crosses the probe volume uses fast response photodetectors, and a PC based data acquisition system. Preliminary results of measurements made in the GRC Mach 4, 10 by 25 cm supersonic wind tunnel are presented. Spontaneous condensation of water vapor in the flow is used as seed. The tunnel is supplied with continuous air flow at up to 45 psia and the flow is exhausted into the GRC laboratory-wide altitude exhaust system at pressures down to 0.3 psia.

Seasholtz, Richard G.↗